Integrated Headend Unit (IHU) Quick Installation Sheet

Similar documents
Headend Unit (HEU) Quick Installation Sheet

Corning Optical Network Evolution (ONE ) Solutions Mid-Power Remote Expansion Unit (MxU)

HX WCS Indoor DAS Remote Unit Quick Installation Sheet

GX Higher Power 40 W Dual-Band WCS/2.5 GHz TDD DAS Remote Quick Installation Sheet


High-Power 40 W Dual-Band SISO/MIMO DAS Remote Unit (GX)

Five-Band Remote Access Unit (RAU5x) Quick Installation Sheet

Installing Power Modules

Corning Distance and Link-Loss Budgets for the Cisco 40GbE BiDi Transceiver

Rack Installation Instructions

Closet Connector Housings (CCH)

Introduction. Overview

Closet Connector Housings (CCH)

IBM. Rack Installation Instructions

1. Unpacking the System

Replacing the Power Supply

Installing the PSU for the S50 and S50N

Quick Start. This document describes how to install the Juniper Networks PTX5000 Packet Transport

H3C S12500 Routing Switch Series

Prisma II Platform. Optoelectronics

Wall-Mountable Connector Housings (WCH)

Power Supply and Fan Module Installation

10/100BASE-TX to 100BASE-FX Media Converter. User s Guide. Rev. 01 (JUN. 2002) 1907M110MM16003 RECYCLABLE

INSTRUCTION MANUAL RA 59 RACK ADAPTER. 1) This manual is valid for the following Model and associated serial numbers: MODEL SERIAL NO. REV. NO.

and Network Interface Modules Installation Instructions

Centrix Platform. Features and Benefits

Closet Connector Housings (CCH)

PIX 515/515E. PIX 515/515E Product Overview CHAPTER

PACSystems* RX3i IC695ACC650

Install the Shelf and Backplane Cable

2U STORAGE ENCLOSURE QUICK INSTALL GUIDE FS4100, FS4500, SC4100, AND FC4100

CLOSET CONNECTOR HOUSING

Installation Note for the Cisco ME 3800X and ME 3600X Switch Power Supply and Fan Modules

OptiSheath Aerial Terminal, SCA-9T Series

M40e and M160 CIP Installation Instructions

E1135C PDU and Pod Upgrade Procedure

PIX 535. PIX 535 Product Overview CHAPTER

Installation Job Aid for Ethernet Routing Switch 5900 Series

9. NTP-C11 Remove and Replace an Ethernet Card, page 1-13 As needed, complete this procedure to remove and replace an ONS CL Ethernet card.

PT-7728/7828 Quick Installation Guide

Cisco Prisma II Platform

Power Supply Installation

Pretium EDGE HD Solutions A LANscape Pretium Solutions Product

Installation Job Aid for Avaya Virtual Services Platform 7200 Series

EXN4000 Storage Expansion Unit Installation and Setup Instructions

Closet Connector Housing (CCH) Splitter Module

Dell Networking C9010 Getting Started Guide

This Datasheet for the IC697CHS790. Rack, 9 Slots, Rear Mount.

Connecting Power and Ground

Vertiv Local Rack Access 18.5" LED LCD Console

Cisco ONS MA Shelf Assembly Hardware

OptiTect Indoor Local Convergence Cabinet, Gen III Series

RACK-220 CHASSIS USER S MANUAL

EDGE Solutions Trunk Cable, SMF-28 Ultra OS2, MTP to MTP, 12 fibres

HP UPS R/T3000 G2. Overview. Precautions. Kit contents. Installation Instructions

Cisco ONS CL Shelf Assembly Hardware

Codian MSE 8000 Media Services Engine

N3240 Installation and Setup Instructions

INSTALLATION INSTRUCTIONS FOR THE BV10-100/1000

Install the Cisco ONS CL

Installing the Interface Line Card in the Cisco cbr Chassis 6

Plug & Play Universal Low-Loss Systems A LANscape Pretium Solutions Product

Junos WebApp Secure 5.0 Hardware Guide

PoE/FPR Kit for Auto-Sync Time Clock. The Auto-Sync Time Clock is a validated time system with a Web interface and auto discovery.

Installing the Cisco XR Router

PIX 520. PIX 520 Product Overview CHAPTER

FreeNAS Mini and Mini XL Network Upgrade Kit

Installing the Cisco AS5400XM Universal Gateway

Product names mentioned in this manual may be trademarks or registered trademarks of those products.

TRC-190 User s Manual

Pretium Rack-mountable 1U Housing Hardware

MONITORING INTELLIRACK USER MANUAL

Installing the Cisco MDS 9020 Fabric Switch

HC900 Controller. Controller CPU and Scanner Module Installation and Replacement

Installing the Cisco ADE 2130 and 2140 Series Appliance Hardware Options

Coarse Wavelength Division Multiplexing (CWDM) Solutions

EATON Transformer Module

Corning Optical Network Evolution (ONE ) SD-LAN Ordering Guide

TRC-190 User s Manual

MPP200 User s Manual

Rack Installation Instructions

OptiSheath MultiPort Terminal

IES User Manual. 8 FE + 1 MM SC Unmanaged Switch -40 to 75, DIN-rail. v

AutoScan to MultiScan Replacement Kit

MPP1700 User s Manual

NI PXIe-1062Q Power Supply Shuttle

N3220 Installation and Setup Instructions

ClearCube F6151 Media Converter Chassis System with 10/100BaseTX to 100BaseFX Converter

Removing and Replacing Chassis Components

ChromaFlex Chassis. Hardware Interface Manual

RMB Peripheral Units Installation Guide

System Storage DS3950 Quick Start Guide

SFP GIGABIT MANAGED SWITCH ECO

TDM To MiniMech conversion ProceDure

Installing the Server into a Rack

Installation and Configuration Guide

16Hi HARDWARE INSTALLATION GUIDE

Installation of the POTS splitter card requires the following steps: Determining the cables you need. Installing the POTS splitter chassis

Fast Ethernet Converter. User Guide MICROSENS

User s Guide. Mobile Rack Device Mounting Kit for Echo Express III-R and xmac Pro Server. Quick Start Guide Video Available Online!

Transcription:

Integrated Headend Unit (IHU) Quick Installation Sheet CMA-350-AEN GENERAL INFORMATION. The IHU chassis includes the S-FAM (fan module) and preassembled cable management tray routed with a 34-in, 9-pin cable ready for the expanders (i.e., RIX and OIX) connectivity. 2. Each IHU includes 4 slots supporting the following modules: RIX slot (Slot ) OIM slots (Slots 0-3; marked in blue) RIM slots (Slots 2-5; marked in red) One OIX slot (Slot 4) Dual slots (Slots 6-9; marked in white) each slot supports RIMs or OIMs 3. IHU supports the following expansion connection options: To a single IHU or, To one HEU and one OIU This document describes the installation procedure for the Corning optical network evolution (ONE ) solutions integrated headend unit (IHU) and relevant modules.. ITEMS REQUIRED FOR IHU INSTALLATION The following items are required for installing the IHU. If any of the listed items are missing, contact your Corning representative. IHU Kit Quantity Item Integrated Headend Unit Chassis Fan Module (S-FAM) single unit hosting four fans (installed in the chassis rear) RJ45/RJ45 Communication Cable L = 2 m - 2.5 m (P/N 705900003) HCM management cable Cable Management Tray includes management tray with routed ERFC cable ERFC (Expander Cable) RF interface cable between RIX and OIX modules; 9-pin SMP to SMP connector; L = 34 in Kits Required for IHU Installation Table Quick Installation Sheet CMA-350-AEN Page

RIM Kit (up to 8 according to order) Quantity Item Radio Interface Module (service specific) OIM Kit (up to 8 according to order) Quantity Item Optical Interface Module (OIM) MTP -LC APC Harness Cable (P/N 37HP90062-006F) connector for splitting fibers (6) leading from OIM to FMU Edge module RIX Kit Quantity Item RF Expander Module expands the RF sources to the OIM modules via the OIX Pilot Transport Cable (P/N: PCKC47*) Single QMAto-QMA cable; L = 47 in; used for passing reference clock signal connections between RIX modules. *Additional various lengths are available: PCKC20: L = 20 in PCKC63: L = 63 in PCKC79: L = 79 in (per item) OIX Kit Quantity Item OIU Expander Module connects to the RIX expander module; provides RF interface between RIM and OIMs PSM Kit (AC or DC modules or 2 kits according to order) PSM-AC: 00-240 VAC Power Supply Module including standard IEC 60320- C3 cable PSM-DC: 48 V DC Power Supply Module; 9 A max.; Includes 6-pin terminal block connector Quantity Item Controller Module Kit (HCM or ACM according to order) HCM Kit (Headend Control Module) installed in Main IHU; enables remote/local management of all hosted units ACM Kit (Auxiliary Control Module) installed in Auxiliary IHUs; provides management connections for the Auxiliary IHU. Kits Required for IHU Installation Table (continued) Quantity Item Quick Installation Sheet CMA-350-AEN Page 2

2. ASSEMBLE CABLE MANAGEMENT TRAY ONTO IHU AND CONNECT ERFC CABLE TO RIX AND OIX MODULES Refer to Appendix A of this document for instructions on how to assemble the provided Cable Management Tray and connect ERFC Cable (routed through tray). 3. MOUNT CHASSIS IN 9-IN RACK Notes: IHU chassis requires 4U rack height availability Rack nuts and screws not provided Step : Step 2: Determine the location of the IHU in the rack while considering additional units (i.e., IHU, HEU, OIU) and the lengths of the available ERFC cable. Referring to Figure, secure the units rack ears to the rack frame as follows: Insert two screws halfway into the rack frame (one on each side). Position the bottom half slots of the chassis rack ears onto the screws. Secure the unit in the rack via all applicable bracket holes using the appropriate rack nuts and screws. Figure : Installing Chassis in Rack Quick Installation Sheet CMA-350-AEN Page 3

4. INSTALL ALL MODULES Note: Step : Step 2: For modules with ejectors (i.e., RIM, RIX, OIM, OIX, and HCM/ACM) verify that the ejectors are completely open when inserting in dedicated slot and then push in until the module clicks in to the backplane. Figure 3 shows example of module type captive screws and ejectors. Refer to Figure 2 for module locations. Remove blank panel and slide in the relevant module (chassis slots are 00 percent mistake proof): (One) HCM (for Standalone/Master IHUs)/ (One) ACM (for Auxiliary IHU) (One to two) PSM for single-power-supply installations, install the PSM in either (PSM) slot. (One) RIX module (One to eight) RIM no need to terminate unoccupied RIM slot. (One to eight) OIM (One) OIX module Referring to Figure 3, secure the modules to backplane by: Closing the ejectors (for relevant modules) Tightening the captive screws Figure 2: Example of Occupied IHU (Without Cable Management Tray) Figure 3: Examples of Module Captive Screws and Ejectors 5. GROUND HEU CHASSIS The grounding connection is performed via a twohole, standard-barrel grounding lug located on the HEU rear panel (see Figure 4). - For use with stranded copper wire conductors - 0-4 AWG - Holes /4 in Figure 4: Grounding Lug (Chassis Rear) Quick Installation Sheet CMA-350-AEN Page 4

6. IHU EXPANSION CONNECTIONS TO IHU, HEU, AND OIU UNITS Notes: A single IHU supports expansion connections as follows: To one additional IHU To one HEU and one OIU For connections to additional IHUs or HEUs, and OIUs: Using the appropriate length ERFC cable (according to distance of available OIX/RIX port) connect remaining IHU RIX and OIX module connectors as follows: Connections to additional IHU (see Figure 5): - IHU # RIX 9-Pin connector to the corresponding IHU #2 OIX module - IHU # OIX 9-Pin connector to the corresponding IHU #2 RIX module Figure 5: RIX to OIX Connections - Two IHUs Connections to additional HEUs and OIUs (see Figure 6): - IHU RIX 9-Pin connector to the corresponding connector on the OIX module of the additional OIU. - IHU OIX 9-Pin connector to the corresponding connector on the RIX module of the additional HEU. Note: The RIX and OIX modules of the additional HEU and OIU units must also be connected. Figure 6: RIX to OIX Connections between IHU, HEU, and OIU Quick Installation Sheet CMA-350-AEN Page 5

7. CONNECT RIMS TO RF SOURCE(S) Step : Step 2: Step 3: For each RIM connect the RF coax cable to the RIM s simplex or duplex QMA connectors. See Figure 7. Route the connected cables through the cable management tray towards the right or left of the tray (depending on the module location in the chassis). Connect the RF coax cable from the RIM to the corresponding external RF source. 8. RIX 0 MHz PILOT CLOCK CONNECTIONS Figure 7: RIM RF Source Simplex/Duplex Interfaces Notes: This section is only relevant for configurations with additional IHU or HEU and OIU units. The REF IN and REF OUT pilot clock ports must be connected in a closed loop as shown in Figure 8. Both RIX modules of each chassis must be connected. The jumper cables are routed through the sides of the cable management tray and door. Referring to Figure 9, use the QMA/QMA jumper cable (PCKC47 provided with each RIX) to connect the REF OUT and REF IN ports of each of the RIX modules in the HEU chassis. Figure 8: Example of Pilot Clock Connections Between Two IHUs 9. FIBER CONNECTIONS Using the provided Corning MTP -LC APC Harness Cable: Connect the cable MTP connector to the OIM MTP connector. Remove the protective plastic covers and connect the (3) LC APC connection fibers to the FMU Edge module LC APC connections. See Figure 9. Figure 9: OIM Fiber Connections Quick Installation Sheet CMA-350-AEN Page 6

0. MANAGEMENT CONNECTIONS Notes: One RJ45/RJ45 management cable is provided with each IHU. Refer to control nodule quick installation sheet (CMA-348-AEN) provided with each module for instructions on how to perform the management connections. The management connections are routed to the right via the cable management tray. ATTENTION! Make sure there are no loop back connections to the HCM or ACM modules! An HCM connected to an ACM cannot have another cable connecting it back to the HCM doing so may cause alarm flooding resulting in a system freeze! Figure 0: HCM LOCAL Port to ACM Port LOCAL Management Connection. POWER ON Note: Step : Step 2: Max power consumption for fully loaded chassis: 300 W For PSM-AC modules connect supplied power cable (00-240 VAC) connector to the PSM input connector and to the AC outlet and switch on. See Figure. For PSM-DC modules refer to Quick Start Guide provided with module for wiring pinout. Verify that the Power Status LED on each PSM shows green. See Figure for PSM-AC LED. Figure : AC Power Supply Module LEDs Quick Installation Sheet CMA-350-AEN Page 7

2. VERIFY NORMAL OPERATION Referring to Table 2 and Figure 2, Figure 3, and Figure 4 respectfully verify that the RIM (if RF source is operational), OIM and HCM/ACM LEDs indicate normal operation: Module LED Description RIM RIM N/A DL High DL Low RUN PWR Off DL RF input level in threshold range Steady Red DL RF input level is 3 db above max expected power Off DL RF input level in threshold range Steady Red DL RF input level is 5 db below max expected power Blinking Green RIM module software has initialized and is up and running Off Power off Steady green Input power is within required range Figure 2: RIM LEDs OIM Link /2/3 Steady Green Optical link power to/ from the connected remote is normal Off No optical power from remote detected Run PWR Blinking Green OIM module software has initialized and is up and running Off Power off Steady Green Power input detected in OIM Figure 3: OIM LEDs HCM/ACM PWR Steady Green Power input detected by HCM/ACM RUN SYS FAN Blinking Green HCM software up and running Steady Green Overall status of the managed system is ok Steady Green Normal operation status for all fans Figure 4: HCM/ACM LEDs RIM, OIM, and HCM/ACM LED Descriptions Table 2 Quick Installation Sheet CMA-350-AEN Page 8

APPENDIX: ASSEMBLING IHU CABLE MANAGEMENT TRAY Notes: The IHU cable management tray is used for managing the unit connection cables. The IHU cable management tray includes a routed ERFC34 cable; Expander Cable RF interface cable between RIX and OIX modules; 9-pin SMP to SMP connector; L = 34 in. The tray can be assembled either before or after the IHU module cables are connected. A Phillips screwdriver is required. Step. Attach Cable Management Tray to IHU Chassis Step 2. Connect ERFC cable to RIX (Slot ) and OIX (Slot 4) 9-Pin Connector Connectors ATTENTION! Make sure that ERFC cable is manipulated in such a way that the 9-pin connectors properly connect to the RIX and OIX modules and so that the cable does obstruct the module slots. Do not remove the cable ties holding the cable in place! Figure A: Assembling Cable Management Tray to IHU Chassis Figure A2: Overview of ERFC Cable Connection to RIX and OIX Modules Step 3. Route Connected Cables and Lock Tray Step 4. Example of Routed Cables and Locked Tray Figure A3: Routing Connection Cables and Locking Tray Figure A4: Example of Routed Cables Quick Installation Sheet CMA-350-AEN Page 9

NOTES: Quick Installation Sheet CMA-350-AEN Page 0

NOTES: Quick Installation Sheet CMA-350-AEN Page

NOTES: LLC PO Box 489 Hickory, NC 28603-0489 USA 800-743-2675 FAX: 828-325-5060 International: +-828-90-5000 www.corning.com/opcomm reserves the right to improve, enhance, and modify the features and specifications of products without prior notification. A complete listing of the trademarks of is available at www.corning.com/opcomm/trademarks. All other trademarks are the properties of their respective owners. is ISO 900 certified. 205, 208. All rights reserved. CMA-350-AEN / January 208 P/N 709C05704 Rev. A00