CoolMasterNet Technical Data CoolMasterNet Universal Interface Adapter for HVAC Systems

Similar documents
CoolMasterNet Technical Data CoolMasterNet Universal Interface Adapter for HVAC Systems

Failure to follow WARNING is very likely to result in such grave consequences as death or serious injury

PRELIMINARY. CoolMasterNet PRM. CoolMasterNet Universal Interface Adapter for HVAC Systems. Document Revision /11/2014

IntesisBox Modbus Server - LON

IntesisBox. Making Building Automation go further. LON Products

IntesisBox Modbus Server - BACnet/IP Client

CoolPlug CooLinkHub HVAC Bridge. Quick Installation Guide

KNX Module User Guidelines KNX Module Universal Interface Adapter for HVAC Systems

CoolPlug CooLinkHub HVAC Bridge. Quick Installation Guide

RST ROOM TEMPERATURE TRANSMITTER. Mounting and operating instructions

KNX Module User Guidelines KNX Module Universal Interface Adapter for HVAC Systems

Message Runner KP3H. Text Display. Small messages on your machine. Compact DIN 36 x 72 profile. Green and orange character display.

MODEL: GR8-EM. Communication Adaptor GR8 Series

RXTH DUAL ROOM SENSOR / SWITCH

RTD-NET Installation Instructions

RXTP ROOM TEMPERATURE

CNVT-USB-RS485 MODBUS TO USB CONVERTER. Operating instructions

Lantech. IPES /100TX with 4 PoE Injectors 24~48VDC Industrial Switch. User Manual

IntesisBox KNX - BACnet/IP Client

Features. Intel 45nm Atom Processor N270: 1.6 GHz

Features and Benefits. Certifications

Communication over Modbus protocol Connection with multiple controllers Application upgrade by using an SD 1) card or a USB stick

MVS RAIL ELECTRONIC FAN SPEED CONTROLLER. Mounting and operating instructions

USER MANUAL. VA-1USB-T USB Transmitter. VA-1USB-R USB Receiver MODELS: P/N: Rev 3

ASCII Server - BACnet/IP Client. Gateway for integration of BACnet IP devices into ASCII enabled control systems.

Submittal Data Sheet WAGO Node for itm

HMIGTO6315 advanced touchscreen panel stainless 800 x 600 pixels SVGA- 12.1" TFT - 96 MB

Submittal Data Sheet intelligent Touch Manager DCM601A71

DEEP SEA ELECTRONICS PLC

Strain Gauge Converter

isma-b-mg-ip User Manual Global Control 5 Sp. z o.o. Poland, Warsaw

Installation Guide V1.2

RTD-RA. realtime. Installation Instructions. English A B. Installation Instructions Control Systems LEDS ALL DIMENSIONS IN MM

IntesisBox. v.0.1. User Manual Issue Date: 12/2017 r1.3 EN

User Manual EzLogger WiFi Ver 02

HMIGTO2310 advanced touchscreen panel 320 x 240 pixels QVGA- 5.7" TFT - 96 MB

HMIGTO2300. Main. External source. Chinese (simplified Chinese) Japanese (ANK, Kanji) Korean Taiwanese (traditional Chinese)

ECLYPSE Communication Modules

KNX is a European Standard Protocol used for household and industrial Buliding Management System (BMS).

See instructions to download and install the latest version of LinkBoxLON and the user's manual at

Modbus Server SIEMENS Algorex (printer port)

Buffered Power Supply PS-30DR v1.0

Industrial 2-port RS422/485 Modbus Gateway

ECLYPSE Communication Modules

MPI-DN, MPI-D MULTICHANNEL ELECTRONIC RECORDER for HART or RS-485/ MODBUS RTU SENSORS

Pen Drive USB Datalogger!

USER MANUAL. SL-10 Master Room Controller MODEL: P/N: Rev 4

BMEP processor module M580 - Level 1 - Distributed

UNIVERSAL CURRENT CONVERTER

HMIGTO5310 advanced touchscreen panel 640 x 480 pixels VGA- 10.4" TFT - 96 MB

HMISTO " wide screen touch panel, Ethernet

HMIGTO5310 advanced touchscreen panel 640 x 480 pixels VGA- 10.4" TFT - 96 MB

Industrial 1-port RS422/485 Modbus Gateway IMG-110T

Dupline Fieldbus Components

HMIGTO6310 advanced touchscreen panel 800 x 600 pixels SVGA- 12.1" TFT - 96 MB

IPM-S500 Series MID SINGLE PHASE AND THREE-PHASE ENERGY COUNTERS

DTM Distributed Transmitter Monitor

Webdom Datalogger 1.5

HMIGTO6310 advanced touchscreen panel 800 x 600 pixels SVGA- 12.1" TFT - 96 MB

PG AB Omron FINS to Modbus RTU Protocol Converter

HMIGTO1300 advanced touchscreen panel 320 x 240 pixels QVGA- 3.5" TFT - 64 MB

TEMPERATURE AND HUMIDITY TRANSDUCER P18 TYPE USER S MANUAL

Introduction Video Camera Support Option TREQ Platform Datasheet. January Rev. 2 A-317 Video Getting Started Guide 1 / 6

PG AB Notifier NFS 3030 to Modbus RTU Protocol Converter

DPM-3221 Digital DC Power Meter with data logging capability.

10/100Base-TX Industrial Ethernet Extender

iologik E2200 Series Smart Ethernet remote I/O with Click&GO Logic Introduction Remote I/O PC-Free Alarm and Control Intelligence

HMIGTO1310 advanced touchscreen panel 320 x 240 pixels QVGA- 3.5" TFT - 96 MB

A-307. Mobile Data Terminal. Android OS Platform Datasheet

PG AA Modbus RTU to SNMP Protocol Converter

OPERATION AND MAINTENANCE MANUAL

IntesisBox KNX - BACnet/IP Client

String Inverter (SUN2000-8/12KTL)

HMIGTO2300 advanced touchscreen panel 320 x 240 pixels QVGA- 5.7" TFT - 64 MB

User Manual. cmt-svr Startup Guide

RS 485 Mini Modbus 1AO

RTD-W Installation Instructions

F1000 User's Manual. (Version: V1.01)

PG AB Fike Cheetah to Modbus TCP Protocol Converter

USER MANUAL. RC-43SL 6-Button Room Controller MODEL: P/N: Rev 3.

HMIGTO1310 advanced touchscreen panel 320 x 240 pixels QVGA- 3.5" TFT - 96 MB

Modbus Server - Mitsubishi Electric G50

RS485 MODBUS Module 8AO

THM501 PT100 MODBUS TEMPERATURE TRANSMITTER

Installation & Operation and Maintenance

IntesisBox. Making Building Automation go further. BACnet Products

EX KVIS RS232/422/485 3-in-1 Serial to USB Adapter (w/ 4KV Isolation, 15KV ESD Surge Protection)

DL-10. User Manual. RS-485 Remote Temperature and Humidity. English Ver. 1.0, Jul. 2017

Industrial 2-port RS422/485 Modbus Gateway IMG-120T

Features and Benefits. Certifications

Allows detailed and easy monitoring and operation of VRV systems (maximum 2 x 64 groups / indoor units)

PM174 PM174 IEEE1159 ADVANCED POWER QUALITY ANALYZER. Features

HMIGTO2300 advanced touchscreen panel 320 x 240 pixels QVGA- 5.7" TFT - 64 MB

DPM Digital DC Power Meter with Data logging capability. User Manual

General Specifications

RTT2 ROOM TEMPERATURE SWITCH. Mounting and operating instructions

MCX402DR-BRD I/O expander. Operating Manual

IntesisBox Modbus Server - Honeywell XLS 80

RAD-DO8-IFS. I/O extension module, eight digital transistor outputs. Data sheet. 1 Description

IntesisBox Modbus Server KILSEN KSA-7xx. User s Manual 08/2013 r1.2 eng

Transcription:

CoolMasterNet Technical Data CoolMasterNet Universal Interface Adapter for HVAC Systems Document Revision 0.3 3/23/2015

Attention 1. During the HVAC system automatic operations the CoolMasterNet must be disconnected from the system. Examples of the automatic operations are: Test Reset Automatic charge 2. Do not change the original positions of the quadruple dip switch S inside CoolMasterNet when usingit with VRV/VRF systems. WEEE Directive & Product Disposal At the end of its serviceable life, this product should not be treated as household or general waste. It should be handed over to the applicable collection point for the recycling of electrical and electronic equipment, or returned to the supplier for disposal.

CoolMasterNet Technical Data Contents 3 Table of Contents 1 Features 4 2 Layout 5 3 Physical data 6 4 Specifications 7 5 LCD data 8 6 HVAC Interfaces 9 7 GPIO 10 8 Options 11

CoolMasterNet Technical Data Rev 0.3 Features 4 1 Features Seamless integration of HVAC systems with all Home Automation/BMS controllers Compatibility with all VRV/VRF HVAC brands e.g. Daikin, Mitsubishi Electric, etc Multi-brand simultaneous support Interfaces via RS232 (ASCII), RS485 (MODBUS RTU according to EIA/TIA-485 standard), Ethernet (ASCII & MODBUS IP) for all HVAC brands Full control & monitoring of HVAC indoor units operation Color LCD with Touch Screen for control and system management "All On" / "All Off" capability using external signal (e.g. for fire alarm systems) Configurable GPIO Remote access by Smart Phone, Tablet and PC (www.coolremote.net). Supported by operating systems: Windows, IOS, Android Cloud integration HVAC systems diagnostics (optional) Direct KNX interface (optional extension board)

CoolMasterNet Technical Data Rev 0.3 Layout 5 2 Layout 1. USB Host 2. Power 3. Power Plug 4. RS232 Port 5. HVAC Line L1 6. HVAC Line L2 7. HVAC Line L3 or RS485 Port 8. Ethernet Port 9. GPIOs 10. HVAC Line L7 11. HVAC Line L6 12. HVAC Line L5 13. HVAC Line L4 14. USB Device Port 15. DIP Switches P,Q, R,S 16. LCD with Touch Screen

CoolMasterNet Technical Data Rev 0.3 Physical data 6 3 Physical data Front view Rear view Bottom view Side view Product dimensions and weight: Dimensions ( HxWxD ) 90 x 156 x 35 [mm] 3.54 x 6.14 x 1.33 ["] Weight 266 [Gram] 0.58 [lbs] Transportation packing dimensions and weight: Dimensions ( HxWxD ) 70x140x280 [mm] 2.75x5.51x11.02 ["] Weight 800 [Gram] 1.76 [lbs]

CoolMasterNet Technical Data Rev 0.3 Specifications 7 4 Specifications Power supply Mounting Parameter Min load* Max load** Data 5V/175mA (via mini USB); 12V/120mA; 24V/70mA 5V/300mA (via mini USB); 12V/200mA; 24V/120mA DIN rail / wall Operating conditions Ambient temperature -10 C ~ 60 C / 14 F ~ 140 F Humidity 0% ~ 96% non-condensing Storage conditions Ambient temperature -20 C ~ 70 C / -4 F ~ 158 F Humidity 0 % ~ 98 % non-condensing Dimensions HxWxD 156 x 109.8 x 35.32 [mm] / 6.14 x 4.32 x 1.39 ["] LCD Size / # of dots / # of colors 2.8" / 240 x 320 / 262K Input Touch panel 8 bit encoded analog input Direct HVAC conenction Connection to the 2 wired HVAC bus MODBUS (A / B) RS-485 communication line Communication functions Ethernet 100Mbps RS-232 DB9, 9600Bps, ASCII USB Host 12Mbps USB mini 12Mbps Maximal allowable wiring length (to BMS) over RS232 25 [m] / 82 [ft] Maximal allowable wiring length (to BMS) over RS485 1000 [m] / 3300 [ft] Maximal allowable wiring length (to router) over Ethernet 137 [m] / 450 [ft] Certification FCC, CE (EN 60335-1, EN 60335-2-40) *One HVAC line and Ethernet are connected. **USB host, Ethernet, HVAC lines 1-7 are connected.

CoolMasterNet Technical Data Rev 0.3 LCD data 8 5 LCD data Technical data: Display Type TFT NEGATIVE TRANSMISSIVE Display Color 262K Display Format 240x320 (RGB) Operation Temperature -10 C ~ 60 C / 14 F ~ 140 F Storage Temperature -20 C ~ 70 C / -4 F ~ 158 F Back light Color WHITE Dimension ( H x W ) 57.6 x 43.2 [mm] / 2.26 x 1.70 ["] Touch panel Resistive Dimensions:

CoolMasterNet Technical Data Rev 0.3 HVAC Interfaces 9 6 HVAC Interfaces CoolMasterNet supports various HVAC systems, that have to be connected to designated lines L1-L7. These lines support single or multi brand HVAC, based on limitations, specified below. HVAC connectivity table (for single HVAC line use) Line # Manufacturer Interface Terminals Polarity Maximum Indoor Units (Manufacturers limitation) L1/L2 L4/L5 L6/L7* Maximum Outdoor Units (Manufacturers Limitation) Daikin DIII-NET F1 F2 none 64 10 Sanyo S-NET U1 U2 none 64 16 Panasonic U1 U2 none 64 16 Toshiba TCC LINK U1 U2 none 64 16 Mitsubishi M-NET M1 M2 none 50 10 Electric Hitachi H Link, H Link 2 1 2 none 64 10 LG Inter A Inter B + - 128 - Gree A B + - 16 4 Mitsubishi Heavy Industries SuperLink / New SuperLink A B + - 128 10 Samsung F1 F2 / R1 R2 + - 64 10 LG Inter A Inter B + - 128 - Gree A B + - 16 4 Mitsubishi SuperLink / New A B + - 128 10 Heavy SuperLink Industries Samsung F1 F2 / R1 R2 + - 64 10 USB device Fujitsu (external Port LON USB adapter required) LON (ANSI/CEA- 709.1-B) X1 X2 none 128 10 Possible Multi HVAC Brand connectivity options L1 L2 L4 L5 L6 L7 L1** ü ü ü ü L2** ü ü ü ü L4 ü ü ü ü ü L5** ü ü ü ü L6* ** ü ü ü ü L7* ü ü ü ü ü Limitations: Total number of supported indoors (for all HVAC ports) cannot exceed 256 units *When DIP switches P1 and P2 are "ON", line L6 and L7 cannot be used as separated lines (either L6 or L7), but the polarity on the HVAC won't be required. **In any case L2 cannot be connected simultaneously with L6 and L1 cannot be connected simultaneously with L5.

CoolMasterNet Technical Data Rev 0.3 GPIO 10 7 GPIO Parameter GPIO A GPIO B GPIO C GPIO D V IL <1V <1V <1V ADC V IH >2.4V >2.4V >2.4V ADC V OUT HI 3.3V 3.3V 3.3V 3.3V I OUT 20mA 20mA 20mA 20mA Pull Up 5.6K 5.6K 5.6K N.A.

CoolMasterNet Technical Data Rev 0.3 Options 11 8 Options PRO This option is available for Daikin, Mitsubishi Electric and Hitachi, and allows to perform analysis on the HVAC data for service purposes and energy management. It can be enabled on any existing device by activation string. KNX Optional PCB board, that can be mounted inside the CoolMasterNet providing direct connection to the KNX bus. Multiple HVAC Port connection. This option allows to activate several HVAC limes simultaneously for increasing the number of supported indoors or supporting different HVAC brands on the same site. It can be enabled on any existing device by activation string. GPIO Functions CoolMasterNet has 4 digital GPIO, that can be configured for customized applications/functions. By default, GPIO A and B are configured for "All Off" and "All On" functions correspondingly, triggered by external signal.