CoolMasterNet Technical Data CoolMasterNet Universal Interface Adapter for HVAC Systems

Similar documents
CoolMasterNet Technical Data CoolMasterNet Universal Interface Adapter for HVAC Systems

Failure to follow WARNING is very likely to result in such grave consequences as death or serious injury

PRELIMINARY. CoolMasterNet PRM. CoolMasterNet Universal Interface Adapter for HVAC Systems. Document Revision /11/2014

IntesisBox Modbus Server - LON

CoolPlug CooLinkHub HVAC Bridge. Quick Installation Guide

IntesisBox. Making Building Automation go further. LON Products

CoolPlug CooLinkHub HVAC Bridge. Quick Installation Guide

KNX Module User Guidelines KNX Module Universal Interface Adapter for HVAC Systems

IntesisBox Modbus Server - BACnet/IP Client

RST ROOM TEMPERATURE TRANSMITTER. Mounting and operating instructions

KNX Module User Guidelines KNX Module Universal Interface Adapter for HVAC Systems

RXTH DUAL ROOM SENSOR / SWITCH

CNVT-USB-RS485 MODBUS TO USB CONVERTER. Operating instructions

RXTP ROOM TEMPERATURE

Message Runner KP3H. Text Display. Small messages on your machine. Compact DIN 36 x 72 profile. Green and orange character display.

RTD-NET Installation Instructions

Installation Guide V1.2

Communication over Modbus protocol Connection with multiple controllers Application upgrade by using an SD 1) card or a USB stick

MVS RAIL ELECTRONIC FAN SPEED CONTROLLER. Mounting and operating instructions

Lantech. IPES /100TX with 4 PoE Injectors 24~48VDC Industrial Switch. User Manual

Features and Benefits. Certifications

Features. Intel 45nm Atom Processor N270: 1.6 GHz

User Manual EzLogger WiFi Ver 02

ASCII Server - BACnet/IP Client. Gateway for integration of BACnet IP devices into ASCII enabled control systems.

DTM Distributed Transmitter Monitor

Strain Gauge Converter

Submittal Data Sheet WAGO Node for itm

HMIGTO6315 advanced touchscreen panel stainless 800 x 600 pixels SVGA- 12.1" TFT - 96 MB

Submittal Data Sheet intelligent Touch Manager DCM601A71

DEEP SEA ELECTRONICS PLC

RTD-RA. realtime. Installation Instructions. English A B. Installation Instructions Control Systems LEDS ALL DIMENSIONS IN MM

USER MANUAL. SL-10 Master Room Controller MODEL: P/N: Rev 4

MODEL: GR8-EM. Communication Adaptor GR8 Series

DL-10. User Manual. RS-485 Remote Temperature and Humidity. English Ver. 1.0, Jul. 2017

IntesisBox. v.0.1. User Manual Issue Date: 12/2017 r1.3 EN

IntesisBox KNX - BACnet/IP Client

HMIGTO2310 advanced touchscreen panel 320 x 240 pixels QVGA- 5.7" TFT - 96 MB

A-307. Mobile Data Terminal. Android OS Platform Datasheet

USER MANUAL. VA-1USB-T USB Transmitter. VA-1USB-R USB Receiver MODELS: P/N: Rev 3

User Manual. cmt-svr Startup Guide

HMIGTO2300. Main. External source. Chinese (simplified Chinese) Japanese (ANK, Kanji) Korean Taiwanese (traditional Chinese)

ECLYPSE Communication Modules

IntesisBox KNX - BACnet/IP Client

UNIVERSAL CURRENT CONVERTER

Modbus Server SIEMENS Algorex (printer port)

Industrial 1-port RS422/485 Modbus Gateway IMG-110T

Pen Drive USB Datalogger!

F1000 User's Manual. (Version: V1.01)

Buffered Power Supply PS-30DR v1.0

MPI-DN, MPI-D MULTICHANNEL ELECTRONIC RECORDER for HART or RS-485/ MODBUS RTU SENSORS

RTT2 ROOM TEMPERATURE SWITCH. Mounting and operating instructions

ECLYPSE Communication Modules

BMEP processor module M580 - Level 1 - Distributed

HMIGTO5310 advanced touchscreen panel 640 x 480 pixels VGA- 10.4" TFT - 96 MB

IntesisBox Modbus Server KILSEN KSA-7xx. User s Manual 08/2013 r1.2 eng

HMISTO " wide screen touch panel, Ethernet

HMIGTO5310 advanced touchscreen panel 640 x 480 pixels VGA- 10.4" TFT - 96 MB

User Manual. cmt-svr Startup Guide

DPOM8-24/20 DIN RAIL POWER OVER MODBUS MODULE. Mounting and operating instructions

Extension module for BACnet over Ethernet / IP and graphic Web functions

METERSUK. SmartLink D Y N A M i T E. 3 MOD CT Series. User Manual KEY FEATURES INDEX 3. TECHNICAL DESCRIPTION.

Dupline Fieldbus Components

S SENECA. Installation Manual Z-TWS4. Z-PC Line. Web Multifunction Controller Straton / Linux

HMIGTO6310 advanced touchscreen panel 800 x 600 pixels SVGA- 12.1" TFT - 96 MB

EE360. High-End Moisture in Oil Transmitter. Typical applications. Features EE360 EE360. (+34)

RAD-DO8-IFS. I/O extension module, eight digital transistor outputs. Data sheet. 1 Description

The TRSUN is the complete solution for the remote monitoring of photovoltaic plants.

HMIGTO6310 advanced touchscreen panel 800 x 600 pixels SVGA- 12.1" TFT - 96 MB

JUMO mtron T Measuring, Control, and Automation System

POWERWISE INDAC SETUP MANUAL

The most advanced communication gateway solutions for the integration of systems

DPM-3221 Digital DC Power Meter with data logging capability.

Introduction Video Camera Support Option TREQ Platform Datasheet. January Rev. 2 A-317 Video Getting Started Guide 1 / 6

PT2060 Monitor. PT2060/91 SIM System Interface Module. Specifications. Electrical. Messtechnik

All models shown smaller than actual size (probes sold separately except on RH model). UWBT-RH Relative humidity (includes probe).

OPERATION AND MAINTENANCE MANUAL

USER MANUAL. RC-76R/RC-78R Room Controllers MODEL: P/N: Rev 2

HMIGTO1300 advanced touchscreen panel 320 x 240 pixels QVGA- 3.5" TFT - 64 MB

iologik E2200 Series Smart Ethernet remote I/O with Click&GO Logic Introduction Remote I/O PC-Free Alarm and Control Intelligence

RТTH DUAL ROOM SWITCH

RTD-W Installation Instructions

EX KVIS RS232/422/485 3-in-1 Serial to USB Adapter (w/ 4KV Isolation, 15KV ESD Surge Protection)

10/100Base-TX Industrial Ethernet Extender

HMIGTO1310 advanced touchscreen panel 320 x 240 pixels QVGA- 3.5" TFT - 96 MB

String Inverter (SUN2000-8/12KTL)

HMIGTO2300 advanced touchscreen panel 320 x 240 pixels QVGA- 5.7" TFT - 64 MB

Features and Benefits. Certifications

USER MANUAL. RC-43SL 6-Button Room Controller MODEL: P/N: Rev 3.

General Specifications

KRAMER ELECTRONICS LTD. USER MANUAL MODEL: RC-76R/RC-78R Room Controllers. P/N: Rev 5

Modbus Server - Mitsubishi Electric G50

Industrial 2-port RS422/485 Modbus Gateway

HMIGTO1310 advanced touchscreen panel 320 x 240 pixels QVGA- 3.5" TFT - 96 MB

DXTH DUCT SENSOR / SWITCH FOR TEMPERATURE AND HUMIDITY. Mounting and operating instructions

DPM Digital DC Power Meter with Data logging capability. User Manual

IntesisBox Modbus Server - Honeywell XLS 80

OHIO SEMITRONICS, INC. AC MULTIFUNCTION PROGRAMMABLE TRANSDUCERS & -1000L

HPS-M -2 DIFFERENTIAL PRESSURE TRANSMITTER. Mounting and operating instructions

Energy-efficient heating, ventilation and air-conditioning Technologies for certified buildings

isma-b-mg-ip User Manual Global Control 5 Sp. z o.o. Poland, Warsaw

Transcription:

CoolMasterNet Universal Interface Adapter for HVAC Systems Document Revision 0.6 4/25/20 20 CoolAutomation LTD.

Attention 1. During the HVAC system automatic operations the CoolMasterNet must be disconnected from the system. Examples of the automatic operations are: Test Reset Automatic charge 2. Do not change the original positions of the quadruple dip switch S inside CoolMasterNet when using it with VRV/VRF systems. WEEE Directive & Product Disposal At the end of its serviceable life, this product should not be treated as household or general waste. It should be handed over to the applicable collection point for the recycling of electrical and electronic equipment, or returned to the supplier for disposal.

Contents 3 Table of Contents 1 Features 4 2 Layout 5 3 Physical data 6 4 Specifications 7 5 LCD data 8 6 HVAC Interfaces 9 7 GPIO 11 8 Options 12 20 CoolAutomation LTD.

1 Features 4 Features Seamless integration of HVAC systems with all Home Automation/BMS controllers Compatibility with all VRV/VRF HVAC brands e.g. Daikin, Mitsubishi Electric, etc Multi-brand simultaneous support Interfaces via RS232 (ASCII), RS485 (MODBUS RTU according to EIA/TIA-485 standard), Ethernet (ASCII & MODBUS IP) for all HVAC brands Full control & monitoring of HVAC indoor units operation Color LCD with Touch Screen for control and system management "All On" / "All Off" capability using external signal (e.g. for fire alarm systems) Configurable GPIO Remote access by Smart Phone, Tablet and PC (www.coolremote.net). Supported by operating systems: Windows, IOS, Android Cloud integration HVAC systems diagnostics (optional) Direct KN interface (via extension board) 20 CoolAutomation LTD.

2 Layout 5 Layout 1. USB Host 2. Power 3. Power Plug 4. RS232 Port 5. HVAC Line L1 6. HVAC Line L2 7. HVAC Line L3 or RS485 Port 8. Ethernet Port 9. GPIOs. HVAC Line L7 11. HVAC Line L6 12. HVAC Line L5 13. HVAC Line L4 14. USB Device Port 15. DIP Switches P,Q, R,S. LCD with Touch Screen 20 CoolAutomation LTD.

3 Physical data 6 Physical data Front view Rear view Bottom view Side view Product dimensions and weight: Dimensions ( HxWxD ) Weight 90 x 156 x 35 [mm] 3.54 x 6.14 x 1.33 ["] 266 [Gram] 0.58 [lbs] Transportation packing dimensions and weight: Dimensions ( HxWxD ) Weight 70x140x280 [mm] 800 [Gram] 2.75x5.51x11.02 1.76 [lbs] ["] 20 CoolAutomation LTD.

4 Specifications 7 Specifications Parameter Min load* Power supply Max load** Mounting Ambient temperature Humidity Ambient temperature Storage conditions Humidity Dimensions HxWxD LCD Size / # of dots / # of colors Input Touch panel Direct HVAC conenction MODBUS (A / B) Ethernet Communication functions RS-232 USB Host USB Device Maximal allowable wiring length (to BMS) over RS232 Maximal allowable wiring length (to BMS) over RS485 Maximal allowable wiring length (to router) over Ethernet Certification Operating conditions Data 5V/175mA (via mini USB); 12V/120mA; 24V/70mA 5V/300mA (via mini USB); 12V/200mA; 24V/120mA DIN rail / wall - C ~ 60 C / 14 F ~ 140 F 0% ~ 96% non-condensing -20 C ~ 70 C / -4 F ~ 158 F 0 % ~ 98 % non-condensing 156 x 9.8 x 35.32 [mm] / 6.14 x 4.32 x 1.39 ["] 2.8" / 240 x 320 / 262K 8 bit encoded analog input Connection to the 2 wired HVAC bus RS-485 communication line 0Mbps DB9, 9600Bps, ASCII 12Mbps 12Mbps 25 [m] / 82 [ft] 00 [m] / 3300 [ft] 137 [m] / 450 [ft] FCC, CE (EN 60335-1, EN 60335-2-40) *One HVAC line and Ethernet are connected. **USB host, Ethernet, HVAC lines 1-7 are connected. 20 CoolAutomation LTD.

5 LCD data 8 LCD data Technical data: Display Type Display Color Display Format Operation Temperature Storage Temperature Back light Color Dimension ( H x W ) Touch panel TFT NEGATIVE TRANSMISSIVE 262K 240x320 (RGB) - C ~ 60 C / 14 F ~ 140 F -20 C ~ 70 C / -4 F ~ 158 F WHITE 57.6 x 43.2 [mm] / 2.26 x 1.70 ["] Resistive Dimensions: 20 CoolAutomation LTD.

6 HVAC Interfaces 9 HVAC Interfaces CoolMasterNet supports various HVAC systems, that have to be connected to designated lines L1-L8. These lines support single or multi brand HVAC, based on limitations, specified below. HVAC connectivity table (for single HVAC line use) Line # Manufacturer Interface Terminals L1/L2 L4/L5 L6/L7* Daikin Sanyo Panasonic Toshiba Mitsubishi Electric Hitachi LG Gree Mitsubishi Heavy Industries Samsung Midea Kentatsu Trane Chigo LG Gree Mitsubishi Heavy Industries Samsung Midea Kentatsu Trane Chigo Fujitsu (external DIII-NET S-NET TCC LINK M-NET H Link, H Link 2 SuperLink / New SuperLink Maximum Outdoor Units (Manufacturers (Manufacturers limitation) Limitation) 50 F2 U2 U2 U2 M2 1 Inter A A 2 Inter B B - 128 4 A B - 128 GND GND GND GND - 128 128 4 - GND - GND - GND - GND 128 F1 F2 1 Possible Multi HVAC Brand connectivity options L1 L2 L4 L5 L6 L1** L2** L4 L5** L6* ** L7* L8 Maximum Indoor Units F1 U1 U1 U1 M1 F1 F2 Inter A A SuperLink / New A SuperLink LON (ANSI/CEAL8 via USB Host LON USB adapter 709.1-B) required) Port Polarity / R1 R2 Inter B B B / R1 R2 2 L7 L8 20 CoolAutomation LTD.

HVAC Interfaces Limitations: Total number of supported indoors (for all HVAC ports) cannot exceed 256 units *When DIP switches P1 and P2 are "ON", lines L6 and L7 cannot be used as separated lines (L6 or L7). In this case the polarity on the HVAC connected to L7 won't be required. **In any case L2 cannot be connected simultaneously with L6 and L1 cannot be connected simultaneously with L5. 20 CoolAutomation LTD.

7 GPIO 11 GPIO Parameter V IL V IH V OUT HI I OUT Pull Up GPIO A <1V >2.4V 3.3V 20mA 5.6K GPIO B <1V >2.4V 3.3V 20mA 5.6K GPIO C <1V >2.4V 3.3V 20mA 5.6K GPIO D ADC ADC 3.3V 20mA N.A. 20 CoolAutomation LTD.

8 Options 12 Options PRO This option is available for Daikin, Mitsubishi Electric and Hitachi, and allows to perform analysis on the HVAC data for service purposes and energy management. It can be enabled on any existing device by activation string. KN Extension PCB board, that can be mounted inside the CoolMasterNet providing direct connection to the KN bus. Multiple HVAC Port connection. This option allows to activate several HVAC lines simultaneously for increasing the number of supported indoors or supporting different HVAC brands on the same site. It can be enabled on any existing device by activation string. GPIO Functions CoolMasterNet has 4 digital GPIO, that can be configured for customized applications/functions. By default, GPIO A and B are configured for "All Off" and "All On" functions correspondingly, triggered by external signal. 20 CoolAutomation LTD.