MXM-50. Modbus Interface for Mitsubishi Air-Conditioning. Installation and User Guide.

Similar documents
MM-A20 BMS Interface for Mitsubishi Electric Split Air-Conditioning

MXB-50 BACnet Interface for Mitsubishi Air-Conditioning

Installation Instructions. Procon IP-32M wir-1_ MITSUBISHI ELECTRIC

BMS Interface for Panasonic Air-Conditioning

Procon BAC-A/50. Installation Instructions MITSUBISHI ELECTRIC

Modbus Server - Mitsubishi Electric G50

Modbus Server - Mitsubishi Electric G50

Modbus Server - Mitsubishi Electric G50

IntesisBox Modbus Server Mitsubishi Electric Centralized Controller TCP/IP XML. User Manual Issue Date: 01/2018 r1.0 EN

IntesisBox. KNX - Mitsubishi Electric G50. Gateway for integration of Mitsubishi Electric City Multi air conditioners into KNX control systems.

IntesisBox KNX - Mitsubishi Electric G50

RTD-NET Installation Instructions

IntesisBox Modbus Server LG Air Conditioning. User s Manual Issue Date: 06/2016 r1 eng

Canlan INSTALLATION MANUAL

DUCM Hardware. Niobrara Research & Development Corporation P.O. Box 3418 Joplin, MO USA

INTERFACE SPECIFICATION

RTD-RA. realtime. Installation Instructions. English A B. Installation Instructions Control Systems LEDS ALL DIMENSIONS IN MM

IntesisBox. v.0.1. User Manual Issue Date: 12/2017 r1.3 EN

tsh-700 Series User Manual

Communicative controller for VAV systems

IntesisBox Modbus Server Panasonic

IntesisBox Modbus Server - BACnet/IP Client

IntesisBox Modbus Server - LON

Motortronics VirtualSCADA VS2-MT Communication Gateway VS2-MT User Manual Revision

IPM-01 / IPM-01H MODBUS TCP/RTU Bridge User Guide

Modbus Server - M-Bus (EN ) Gateway for the integration of M-BUS meters with Modbus RTU and TCP based control systems.

RTD-W Installation Instructions

MAXDTC-BT Family User Manual

IntesisBox PA-AC-MBS-1

Installation and Programming Manual. Niobrara Research & Development Corporation P.O. Box 3418 Joplin, MO USA

INTRINSICALLY SAFE DUPLEXER PROTECTION. ELECTRONICS, INC Vulcan Road Apopka, Florida MOTOR INSTRUCTION MANUAL

BAS Router BACnet Multi-Network Router

Installation Manual. DZK BACnet

MODEL: GR8-EM. Communication Adaptor GR8 Series

GW1000 User s Guide. Revision 1.04 Mar 30, 2008

IntesisBox KNX - AIRZONE

Centralized Controller Model: AG-150A

EtherSeries. EtherSeries CR-2. CR-2-Opto. User s Guide. Revised October 7, 2013 Firmware Version 1.X

SHEET. BASgatewayLX Modbus to BACnet Gateway. BASgatewayLX

IntesisBox SMS - Mitsubishi Electric air conditioners

IntesisBox Modbus Server - Honeywell XLS 80

Air-conditioner Network System Centralized Controller AG-150A AG-150A-A GB-50ADA-J

IntesisBox PA-AW-MBS-1 v.2.0

USER MANUAL FOR GS100/GS1003G

Description of options. user s manual. DEIF A/S Frisenborgvej 33 DK-7800 Skive Tel.: Fax:

QUCM Limitorque Controller

IO-INTERFACE. Procon. INSTALLATION MANUAL Version 1.01 MITSUBISHI ELECTRIC FOR INSTALLERS

MODEL CIO-EN MODBUS/TCP, MODBUS/RTU I/O MODULE

Procon A1M. INSTALLATION MANUAL Version MITSUBISHI ELECTRIC FOR INSTALLERS

OPERATION INSTRUCTIONS

EtherSeries Modbus Gateway EMB-2 User s Guide

DESCRIPTION OF MODBUS CONNECTION

Uponor Smatrix Move PRO Controller X-159 Modbus RTU interface

Document Name: User Manual for SC10MK, Modbus RTU to Modbus TCP Converter

Ethernet Interface Module

Embedded Modbus TCP Module GS11-MT. User Manual REV 1.1. SST Automation.

ECAN-240. (Modbus TCP to 2-port CAN Bus Gateway User manual) ECAN-240 Modbus TCP to 2-port CAN Bus Gateway User Manual, Version 1.0.

KNX is a European Standard Protocol used for household and industrial Buliding Management System (BMS).

Dip Switch settings.

DKG-210 UNIVERSAL INTERNET GATEWAY UNIT

MODEL: WL40EW2F. Wireless I/O WL40F Series

Hardened Web-Smart PoE & High Power PoE Ethernet Switch

R3-GE1 BEFORE USE... INSTALLATION POINTS OF CAUTION INSTRUCTION MANUAL ETHERNET INTERFACE MODULE MODEL. (Modbus/TCP)

PMEUCM Hardware. Niobrara Research & Development Corporation P.O. Box 3418 Joplin, MO USA

FCU-4 FAN COIL CONTROLLER

FCU-4 FAN COIL CONTROLLER

MB40 & MB45 MODBUS TCP/IP Gateway Handbook

IntesisBox Modbus Server Fidelio IP

Industrial 1-port RS422/485 Modbus Gateway IMG-110T

For more detailed instruction, see the KTA-282 user manual. This document is a condensed version; intended as a reference.

RGX COMMUNICATIONS GATEWAY

See instructions to download and install the latest version of LinkBoxMB and the user's manual at

REMOTE CONTROL MYSYSTEM

API GUIDE. MODBUS TCP/IP Commands Version 1.3

Panasonic/Sanyo A/C Interface Modbus TCP Installation Instructions

See instructions to download and install the latest version of LinkBoxMB and the user's manual at

CONTROLS.COM. Bacnet and Modbus Modules. T3-22i. T3000 Building Automation System Overview. T3-8o. Ethernet MAIN NET1 RS485 SUBNET2 RS485.

Air-conditioner Network System Centralized Controller AG-150A AG-150A-A GB-50ADA-J

UNIT CONTROLLER 8 (UC8) Modbus RTU communications

See instructions to download and install the latest version of LinkBoxEIB and the user's manual at

Alternative B Type Mid-Span Power Sourcing Equipment. User s Guide

UNIT CONTROLLER 7 (UC7) Operation & Installation. Hydronic Units

IntesisBox ModBus RTU Fujitsu Air Conditioning

ROCKETLINX ES8508 ES8508 ES8508F ES8508-XT ES8508F-XT QUICK INSTALLATION GUIDE

See instructions to download and install the latest version of LinkBoxMB and the user's manual at

EGW1-IA3-MB User s Manual

CAS SEC (Serial) Protocol for Mitsubishi UPS. Gateway

mbc082 Bus Converter

RXTP ROOM TEMPERATURE

FULL DC INVERTER SYSTEMS

IntesisBox. v.2.5. User Manual Issue Date: 12/2017 r1.9 EN. Modbus RTU (EIA-485) Interface for Fujitsu air conditioners.

Industrial Serial Device Server

VPGate Manual PROFIBUS to serial

Gateway 1400 Reference Manual

Software Installation Guide. Version 1.1

GE Fanuc IC695ETM001. Rx3i PacSystem

Intech Micro 2300-A8VI analogue input station MODBUS RTU slave application supplementary manual.

IntesisBox Modbus Server KILSEN KSA-7xx. User s Manual 08/2013 r1.2 eng

BACnet/IP to BACnet MS/TP Router

EQ-DCM User Manual Revision 1.02 Sep 10, 2013

Transcription:

MXM-50 Modbus Interface for Mitsubishi Air-Conditioning Installation and User Guide www.innon.co.uk

1. Product Overview The Black Pear MXM-50 unit allows a Modbus building management system (BMS) to monitor and control air-conditioning units attached to a Mitsubishi G-50A, GB-50A or AG-150 central controller (referred to as G-50 from now on). The Modbus registers can be accessed via the serial comms interface using Modbus RTU on RS232 or RS485, or via the network interface using Modbus/TCP. Depending on the air-conditioning configuration within the G-50, up to 50 groups can be monitored / controlled. The error state of up to 50 OC/BC units can also be monitored. RS232/RS485 Modbus BMS System Serial Comms cable (Not supplied) Outdoor Units Indoor Units Black Pear MXM-50 Cat-5 crossover cable G-50A GB-50A AG-150 Fig.1a System Configuration Example Using RS232/RS485 1

Modbus BMS System Modbus / TCP Ethernet Hub / Switch Outdoor Units Indoor Units Black Pear MXM-50 G-50A GB-50A AG-150 Fig.1b System Configuration Example Using Modbus/TCP 1.1 Supplied Parts No. Part Name Quantity 1 Black Pear MXM-50 1 2 Cat-5 Straight Through Patch Lead 1 3 Cat-5 Crossover Patch Lead 1 4 Din-Rail Clips 2 5 Self-Tapping Screws for Din-Rail Clips 4 6 Installation Manual 1 2

2. Connection Details All electrical work should be carried out by a competent person and wiring must be in accordance with the national electrical installation regulations. 10Base-T Ethernet Serial Comms Port Enable Link Reset Button Power Supply To Ethernet RS485-B RS485-A 24v AC RS232 Tx RS232 Rx Common N/C Can also be used to upgrade the firmware. Fig.2 Connection Details 2.1 Ethernet The Black Pear MXM-50 is a 10Base-T half duplex device and needs to be connected to the G-50 and the local network (if Modbus/TCP is being used). Fig.1b shows the use of a hub / switch ( not supplied ) to make the connections, but the MXM-50 unit and the G-50 could just as easily be connected directly to the network. See Appendix C for port configuration. Note: a) The Black Pear MXM-50 and the G-50 require separate IP addresses which must be on the same subnet. b) The MXM-50 does not support Auto-Negotiation. 3

2.2 Serial Comms Port This connector provides access to the modbus registers using RS232 or 2-wire RS485. The RS232 port can also be used for upgrading the firmware. See Appendix C for port configuration. Serial Comms Port 9 PIN D-SUB FEMALE Pin 2 Pin 3 Pin 5 To PC Comm Port Fig.3a RS232 Comms Lead Wiring Diagram The RS485 interface can be used on a compatible serial communications network shared by multiple RS485 devices. The Slave Address Offset parameter must be set to prevent multiple units using the same slave numbers. It is recommended that screened twisted-pair cable is used. RS485-A is the non-inverting signal and is also named RS485+ RS485-B is the inverting signal and is also named RS485- Common should be connected to the cable screen. Serial Comms Port RS485 network A B Common RS485-A RS485-B Fig.3b RS485 Comms Wiring Diagram 4

2.3 Enable Link Allows a normally-closed volt-free contact to set or reset the Forced- Off feature in the G-50. While the Forced-Off feature is enabled, all air-conditioning units are switched off and all remotecontrollers are disabled. Upon detection of the open contact, the MXM-50 unit sends the Forced-Off Set command to the G-50, and resends at 5 seconds intervals while the contact is open. As soon as the contact closes, the MXM-50 unit sends the Forced- Off Reset command to the G-50 once only. This ensures that any subsequent Forced-Off commands sent via the Modbus BMS system are not overridden. Note: The Black Pear MXM-50 comes supplied with a wire link across the Enable Link terminals. 2.4 Power Supply The Black Pear MXM-50 will accept 24v AC and has a consumption of 8VA. The internal fuse is rated T500mA. THIS EQUIPMENT MUST BE EARTHED 5

3. Air-Conditioning Group Configuration G-50 M-NET IC 01 * IC 02 IC 03 * IC 04 IC 05 IC 06 * IC 07 IC 08 * Group 01 Group 03 Group 06 Group 08 Fig.4 Grouping Example The groupings set up in the G-50 determine which unit addresses can accept commands from the Modbus BMS system. The group number is defined as the lowest indoor unit address within the group. This then becomes the master address for the group, and is the only address within that group that can accept commands. The other units within a group can be classed as slave units and contain the same status parameter values as the master, apart from the Error Code, which is unique to each unit. In the example above, addresses 01, 03, 06 and 08 are the master units, and 02, 04, 05 and 07 are the slave units. Note: Attempting to write a command to a slave unit will have no effect. 6

4. Unit Operation At startup and provided a network cable is attached (the Ethernet Link led should be lit), the MXM-50 unit attempts to establish a connection with the G-50 using the appropriate IP address. Should the G-50 not be found, then a watchdog feature will periodically reset the MXM-50 unit, indicated by the Device Reset led lighting up for 2 seconds. The Global parameter G50 Comms Status can be read via Modbus to determine if the MXM-50 unit is communicating with the G-50. Once established, the G-50 is interrogated to determine the number of active groups. At this point the MXM-50 unit begins its polling sequence, requesting the Mnet status, the status of all active groups, and the list of all current alarms. This sequence is continually repeated, with new control settings from the BMS transmitted to the G-50 by interleaving into the poll sequence. The time required to complete the polling sequence will depend on the number of active groups programmed in the G-50 and the frequency of new control settings sent via Modbus. If the BMS is using RS232 or RS485 and provided a valid modbus message is received, then the Serial Tx led will light to indicate that a Modbus reply has been sent. If Modbus/TCP is being used then there will be increased activity from the Ethernet Tx led. 7

5. Modbus Registers The Black Pear MXM-50 behaves as 20 modbus slaves, each with 60 registers (Offset = 0 to 59). By default the slave addresses are 1 20 but an address offset can be applied to provide ranges 21-40, 41-60, 61-80, 81-100, up to 201-220. This is useful to prevent address clashing when the MXM-50 unit is attached to a communications network containing multiple Modbus devices. The MXM-50 maps the data from the air conditioner units into Modbus registers accessed by two Modbus parameters Slave No. and Offset. All slave numbers referred to in this document assume the default addresses - Add the offset value where applicable. Slaves 1 to 16 each represent 3 units, and slave 17 represents 2 units, with Unit C of slave 17 used for various system settings. See Section 5.4 for details. Each slave is organised as follows: General Information Extended Information Unit A Unit B Unit C Unit A Unit B Unit C Offset 0 Offset 10 Offset 20 Offset 30 Offset 40 Offset 50 General Information for a single unit Register Offset Stored Value 0 Return Air Temp 1 Error Code 2 Setpoint (Read) 3 Mode (Read) 4 Fan Speed (Read) 5 Setpoint (Write) 6 Mode (Write) 7 Fan Speed (Write) 8 On/Off (Read) 9 On/Off (Write) Extended Information for a single unit Register Offset Stored Value 0 Air Direction (Read) 1 Air Direction (Write) 2 Inhibit (Read) 3 Inhibit (Write) 4 Ventilation (Read) 5 Ventilation (Write) 6 Filter Reset (Read) 7 Filter Reset (Write) 8 Unused 9 Unused Examples : 1) To read the current fan speed of unit 8, the required modbus message would contain Slave 3, Function 3, Offset 14. 2) To read the current mode of unit 48, the required modbus message would contain Slave 16, Function 3, Offset 23. 8

On/Off, Inhibit & Filter Reset can also be accessed via Coils. Each slave contains 18 coils, organised as follows: Coil Offset Definition 0 Unit A On/Off (R) 1 Unit A On/Off (W) 2 Unit B On/Off (R) 3 Unit B On/Off (W) 4 Unit C On/Off (R) 5 Unit C On/Off (W) 6 Unit A Inhibit (R) 7 Unit A Inhibit (W) 8 Unit B Inhibit (R) 9 Unit B Inhibit (W) 10 Unit C Inhibit (R) 11 Unit C Inhibit (W) 12 Unit A Filter Reset (R) 13 Unit A Filter Reset (W) 14 Unit B Filter Reset (R) 15 Unit B Filter Reset (W) 16 Unit C Filter Reset (R) 17 Unit C Filter Reset (W) 5.1 OC/BC Error Codes Slave 18 contains the error codes for units 51 to 80. Slave 19 contains the error codes for units 81 to 100. 5.2 Additional Register Usage Slave Offset Setting 17 20 Mnet Status 17 21 G-50 Status 17 22 Global Forced-Off (Write) 17 23 Global Forced-Off (Read) 17 24 New Setting Comparison 19 20 Firmware Number 19 21 Firmware Version 19 22-27 MAC Address 20 7-10 IP Address 20 11-14 Gateway Address 20 15-18 Subnet Mask 20 20 Slave Address Offset 20 21-24 G-50 IP Address 9

5.3 Parameter Settings Parameter Settings Notes Return Air Temperature 0 o C to 99 o C Error Code 4 digit error code where 8000 = No Error Setpoint Temperature Air Conditioner : Cool/Dry : 19 o C to 30 o C Heat : 17 o C to 28 o C Auto : 19 o C to 28 o C Boiler : Heating : 30 o C to 45 o C Heating ECO : 30 o C to 45 o C Hot Water : 30 o C to 70 o C Anti-Freeze : 10 o C to 45 o C Cooling : 10 o C to 30 o C Operation Mode 00: Fan (Draft) 01: Cool 02: Heat 03: Dry 04: Auto 05: (Not Used) 06: AutoCool Not settable 07: AutoHeat 08: Heat Recovery Lossnay Only 09: LC_Auto 10: Bypass 11: Heating Heat-pump boiler only 12: Eco-Heating 13: Hot-Water 14: Anti-Freeze 15: Cooling Fan Speed 00: Low 01: Mid2 (Low Medium) 02: Mid1 (High Medium) 03: High On/Off 00: Off 01: On Air Direction 00: Horizontal 01: Mid1 02: Mid2 03: Vertical 04: Swing Local Inhibit 00: Not inhibited 01: Inhibited Ventilation 00: Off Lossnay / OA units only 01: Low 02: High Filter Sign 00: Filter Sign Off 01: Filter Sign On Cleared by writing 00 to the Filter Sign register or coil. 10

Parameter Settings Notes OC / BC Error Code 4 digit error code where 8000 = No Error Mnet Status 00: Initialising See Appendix D 01: OK G50 Comms State 00: Not found See Appendix D 01: OK Global Forced-Off 00: Disabled 01: Enabled See Appendix D New Setting Comparison 00: Disabled 01: Enabled See Appendix D v1.08 and later 11

5.4 Modbus Table Overview Unit Address Slave General Info Extended Info Coil Base Offsets Base Offset Base Offset On/Off Inhibit Filter Sign 1 1 0 30 0 6 12 2 1 10 40 2 8 14 3 1 20 50 4 10 16 4 2 0 30 0 6 12 5 2 10 40 2 8 14 6 2 20 50 4 10 16 7 3 0 30 0 6 12 8 3 10 40 2 8 14 9 3 20 50 4 10 16 10 4 0 30 0 6 12 11 4 10 40 2 8 14 12 4 20 50 4 10 16 13 5 0 30 0 6 12 14 5 10 40 2 8 14 15 5 20 50 4 10 16 16 6 0 30 0 6 12 17 6 10 40 2 8 14 18 6 20 50 4 10 16 19 7 0 30 0 6 12 20 7 10 40 2 8 14 21 7 20 50 4 10 16 22 8 0 30 0 6 12 23 8 10 40 2 8 14 24 8 20 50 4 10 16 25 9 0 30 0 6 12 26 9 10 40 2 8 14 27 9 20 50 4 10 16 28 10 0 30 0 6 12 29 10 10 40 2 8 14 30 10 20 50 4 10 16 31 11 0 30 0 6 12 32 11 10 40 2 8 14 33 11 20 50 4 10 16 34 12 0 30 0 6 12 35 12 10 40 2 8 14 36 12 20 50 4 10 16 37 13 0 30 0 6 12 38 13 10 40 2 8 14 39 13 20 50 4 10 16 40 14 0 30 0 6 12 41 14 10 40 2 8 14 42 14 20 50 4 10 16 43 15 0 30 0 6 12 44 15 10 40 2 8 14 45 15 20 50 4 10 16 46 16 0 30 0 6 12 47 16 10 40 2 8 14 48 16 20 50 4 10 16 49 17 0 30 0 6 12 50 17 10 40 2 8 14 12

6. Special Functions This section describes functions which can only be enabled via switches on the MXM-50 circuit board. Disconnect the supply before removing the top cover A On 1 2 Off Bank A 1: Auto-Detail 2: Unused. Fig.5 Special Function Switches 6.1 Function Descriptions Bank A-1: Bank A-2: Auto-Detail Off: Mode status reported as Auto, regardless of which Auto mode is active. On: AutoHeat or AutoCool are reported, if active. ( This is the factory default setting ). Not used at present. 13

Appendix A : Physical Dimensions 144mm A A B B B 104mm B A A 34mm 10Base-T Ethernet Serial Comms Port Enable Link Reset Button Power Supply Fig.6 Dimensions The holes marked A should be used when mounting the enclosure on a back panel. The holes marked B can be used to attach the supplied din-rail clips. 14

Appendix B : Reset Button The Reset button has 2 functions : 1) To restore various internal settings to their factory defaults, 2) To force the unit into bootloader mode ready for a firmware update. Function 1 Restore Factory Defaults There are 2 levels to this function. Level 1 : With the unit already ON, press and hold in the reset button. After approximately 5 seconds the Device Reset light will start to flash slowly. Releasing the reset button while the light is flashing slowly will activate Level 1, and then reset the unit. Settings Restored: New Setting Comparison Disabled Level 2 : With the unit already ON, press and hold in the reset button. After approximately 5 seconds the Device Reset light will start to flash slowly. Continue to hold in the reset button until the light starts to flash rapidly. Releasing the reset button while the light is flashing rapidly will activate Level 2, and then reset the unit. Settings Restored: IP Address 192.168.1.11 Gateway Address 192.168.1.11 Subnet Mask 255.255.255.0 G50 IP Address 192.168.1.1 Slave Address Offset 0 15

Function 2 Enable Bootloader Mode Bootloader mode allows the firmware to be updated from a PC. Press and hold in the reset button while powering up the unit. Continue to hold in the reset button for approx. 5 seconds, until the Device Reset light begins to flash ( Long ON, Short OFF ). The unit is now in bootloader mode. Note: Enabling the bootloader in this way is only necessary if the firmware update software fails to automatically put the unit into bootloader mode. 16

Appendix C : Port Configurations RS232/RS485 interface - Modbus RTU - 9600 baud, 8 data bits, no parity, 1 stop bit Network interface - Modbus/TCP - TCP port 502-10base-T half-duplex - Auto-negotiation not supported Modbus Functions accepted - Fn 1 Read Coils - Fn 3 Read Holding Registers - Fn 5 Write Single Coil - Fn 6 Write Single Register - Fn 16 Write Multiple Registers 17

Appendix D : Global Parameters Global Parameter Mnet Comms Status Description Provides an indication of the communication status between the G-50 and the Mitsubishi M-Net network. 00 : M-Net Initialising 01 : M-Net OK Note: While M-Net is initialising, the air-conditioning is effectively offline to control and monitoring requests. G50 Comms Status Provides an indication of the communication status between the MXM-50 and the G-50. 00 : G-50 not responding 01 : G-50 comms OK Note: G-50 not responding either means the G-50 is switched off or is not connected to the network. Global Forced Off New Setting Comparison Enables and disables the Global Forced-Off command. This setting allows the BMS to provide functionality equivalent to the Enable Link described in section 2.3 When enabled, compares new setting commands against current readings and only sends the command on to the G50 if the new setting is different. Prevents the G50 from being continually updated with the same command. This feature is only available in firmware v1.08 and later, and can be set using either the configuration software or any modbus master. 18

Document Revision History Date Document Ver Firmware Ver By Comments 02/04/2012 v1.00 v1.00 mcb First complete version. 12/03/2013 v1.01 v1.09 mcb Corrected various typing errors 19

20

21

Innon Energy Ltd 2 Sheen Road, Richmond, Surrey, TW9 1AE, UK Tel: +44 (0)20 8973 2364 Email: office@innon.co.uk