Installing Keypad and Backplate

Similar documents
Digital Keypad Introduction

EZ-TAG2 Manual_Layout 5 11/12/ :14 Page 1 U S E R M A N UAL

CM-110SK Standalone Keypad Installation Instructions

Single Door Standalone Access Control User Manual

User Manual. PCKeypad Wireless Keypad

TOUCHLOCK compact. Master code: Paxton Access Ltd. ins TOUCHLOCK compact kit. Document Contents. Instructions for the following:

INSTALLATION INSTRUCTIONS Model 930 EntryCheck

CV-110SPK Standalone Keypad/Prox Access Control Installation Instructions

INSTALLATION INSTRUCTIONS 920 EntryCheck TM

Instruction Manual. Vogue. Security. Technology. Innovation 2013-V01

GV-EL124S Electric Strike

TOUCHLOCK compact. Ins-182 Date code:

HSY-S209 EM Metal waterproof access control system User Manual

INSTALLATION INSTRUCTIONS 920P EntryCheck TM

AS Keypad User Manual

Installation and User Manual

Fingerprint Access Control F1. User Manual

BC Digital Keypad. User Manual

Waterproof. Keypad/Reader/Controller

212iL Rev. 1.1

Standalone Keypad Access Control. User Manual. SS-TS2000 Size:120*80*25 mm

INSTALLATION INSTRUCTIONS 921P EntryCheck TM

Standalone Keypad Access Control. User Manual. Please read the manual carefully before use this unit

Physical Specification Vending Machine Card Reader Module Model: CRM-170-xx

RD-SR2 ACCESS SECURITY PRODUCTS LTD. Proximity Card Reader with Remote Control. User Manual

MODEL KP-100 ACCESS CONTROL DIGITAL KEYPAD OPERATING INSTRUCTIONS

CV-550SPK V2 Waterproof Keypad/Reader/Controller Installation Instructions

DOOR FRAME DOOR LEAF. Potential-free contact for external: Intercom Switch. - Home automation system. = 110V AC, 60Hz

9212i INSTALLATION. Stand-Alone Keypad. Instructions

DOLXFD1000B. Waterproof Access Control/Reader

Installation manual CF8-W-Disp-AL

Indoor/Outdoor Proximity Reader and Keypad with 10cm (4in) Read Range

Stand-alone Proximity Access Control

Installation Instructions 4291 and 4292 Keypads

Keypad CT2000. Art. No.: , (black) Art. No.: , (white) Installation Manual

W3-H Waterproof Keypad/Reader/Controller

W3-M. Metal waterproof standalone access control/reader. User Manual

TOUCHLOCK compact keypad Stainless Steel

-DTZ001- Stand-Alone Proximity Access Control. User Manual

SECURITY DOOR CONTROLS 801 Avenida Acaso, Camarillo, Ca (805) Fax: (805)

AK-21. Digital Keyless Entry System. Installation and Programming Instructions

EL-ST100 KEYPAD CONTROLLER

Partizan PAB-FC2. Fingerprint scan time Fingerprint identification time. <0.5 s < % <0.0198% Ingress protection rating

EZTAG3 PROXIMITY AND KEYPAD DOOR ENTRY

7612 Programming Instructions

VIDI-AC-2CS Access Controller/ Reader

IBA-7612 Programming Instructions

DG-800 Stand-Alone Proximity Reader Instruction Manual

GUARD CENTURION OPERATING INSTRUCTIONS THE AUTOMATIC CHOICE

F6-Fingerprint. Access Control/Reader. User Manual. F6 - Simplified Instruction. (Master Code) # (Factory default:1234) Enter the Programming Mode

RBR-SB-KTZ001 LAR 2. User Manual

1 IF-810 or IF-811 Terminal (Slave) 2 Intended Use. 3 Assembly and Installation _V IF-810/IF-811

ADVANTAGE DKE QUICK START GUIDE. 2 Make sure you have everything shown here. 3. What s what? All important internal components labeled for you

TEC100 USER/INSTALLER MANUAL V2.0 REV. 03/2018

Compact Keypad. ins /02/2010. Exit button (push to make) 12V DC release current rating must be less than 1A.

SP1 MP1 WP2 WP1. 125kHz reader models with the following prefixes: 13.56MHz reader models with the following prefixes:

EZTAG3 PROXIMITY AND KEYPAD DOOR ENTRY

Technovision Inc. CD-ROM Audio Sampler. Repair Manual

SL2000E. Status Output. Electronic Code Lock. Features. Input. Exit Button Input. Introduction. Door Contact Input. Functional Description.

RFID/Digital Access Control Keypad

AGATA C200 UK A/200N TARGHA 200. Installation Manual AGATAKIT C 200 UK

BACK-LIT KEYS KEYPAD 100 USER CODES FLUSH MOUNT

e-ask electronic Access Security Keyless-entry RF Keyless-entry entry System TM-Multi Multi Installation Manual FCC ID: TV2EFOB1 (UM21 ~ )

Installing Sentor. Hardware Installation

232iLM Keypad Installation and Programming Instructions

1 IF-812 or IF-815 Terminal (Slave) 2 Intended Use. 3 Assembly and Installation _V IF-812/IF-815

AUDIO AND VIDEO DOOR ENTRY SYSTEM WITH NEXA CODED PANEL

232iLM Keypad Installation & Programming Instructions

VIS-3200 / VIS-3201 User Manual

e-ask electronic Access Security Keyless-entry OEM / Dealer / Installer Cargo Lock / Unlock Version Installation & Instructions (UM04 ~ )

Stand-Alone Data Chip System

3001D Smart Safe Manual

Connecting the EN-4000 to DC Power

PCR43304R, PCR43304RE 4-Channel, 433MHz Penta Receiver with Frequency Hopping

WELCOME. For customer support or any inquiries, please visit our web site at or contact us at

CP150B Vandal & Weather Resistant Keypad Security Systems

Installation Manual. Contents

CM-500 SK 500 USER CODES KEYPAD

IEI emerge MicroNode Install and Setup Guide. Contents

Welcome Contents Diagram

Topic: TB No.: Date: Aug/2017. Model UC4, UC10 & UC45 twin pump variants Regulated 24V Pump Power supply upgrade OVERVIEW

FTK5 PROXIMITY KEYPAD

DIGITAL DISPLAY. for Industry Applications. Series WAY-SSI. Key-Features:

User Manual. Split access control with intelligent secured power supply.

508 SERIES MICROPHONE STATIONS

Panorama rudder indicator TRI-2 Analogue or CAN input Approved according to MED Three extra large scales Long-life LED illumination Built-in dimmer

Specifications: Features:

Owner s Manual. Models 1503 and 1504 Basic Stand Alone Digital Keypad Entry Devices

SC500/SC500P. Installation Note

Installation Instructions Installation Guidelines. Product Summary. For the maximum number of bus devices and touchpads per panel see Table 1.

installation quick guide integrated access control & environmental monitoring

DC Outdoor Power Supply/Chargers

180 Series Keypad. Handbook. Revision 2.1

Switches 6/1. 6/4 Introduction. 6/5 5TE8 control switches. 6/7 5TE4 8 pushbuttons. 6/9 5TE8 On/Off switches. 6/11 5TE1 switch disconnectors

Model: TM-1 / TM1-N. 1 Time Clock Series

PXL-250 Tiger Controller

3.3: Setting momentary / latching switches Page Warning Regarding Operation Page 8

QUICK START GUIDE. 2.4 Inch TFT Terminal Time Attendance & Access Control

2000 Series e/em Style Keypad Installation and Programming Manual

AMERICAN ACCESS SYSTEMS, INC.

Transcription:

Installing Keypad and Backplate Fig.1 Positioning of Fixing Holes and Cable Outlet Cable Outlet, Drill Diameter 10mm for Cable Access Remove the back plate, which is fitted to rear of the keypad, using a 2mm Allen key provided and put the screw in a safe place until required. Fixing Holes Fig.2 Preparation and Installation of Back Plate 1. Select a suitable location to fit the keypad and mark the position to two fixing screws and the cable access hole as per fig.1 2. If fitting to brickwork use the rawl plugs provided and drill two 6mm diameter holes to suit. Otherwise, drill the two fixing holes 3mm in diameter to allow a 4mm button head screw to cut its own thread. The cable access hole should be 10mm in diameter to give sufficient clearance. Vert. CL 1

3. Once the back plate is securely fastened to the application the cable run should be installed from the power supply to the keypad. Cut the 3 metre length supplied with the keypad if necessary in order to joint the keypad cable with the run at a convenient location. Fig. 3 Inserting Keypad Cable into Back Plate 4. Having connected the keypad to the cable run, hook the keypad onto the back plate slot in the rear of the keypad located at the top of the aperture as per fig. 4. Pivot the keypad so that it sits flat against the back plate and is in line with the tap hole located in the underside of the flange of the back plate. Tighten the Allen screw and complete the remaining tasks as described. 5. Ensure the diameter of the cable is sufficient for the length of the run and the amperage draw of the lock so as to minimise line drop. 6. Ensure the MOV supplied is fitted to the lock either to its supply cables or on its supply connections on its terminal block. Fig.4 Fitting Keypad to Back Plate 2

Wiring Diagram For RiteKey 30-02 (12VDC Shown) Specification Operating Voltage: 12 to 18 Volts AC or DC Current Consumption: standby mode approx. 15ma Maximum Draw: 130ma (not including door lock) Door Relay: maximum rating 2 amps at the operating voltage Service Temperature: +70 to 20 degrees C. V +V Black Red 12VDC PSU Negative, Connect to Negative Supply from Lock for both Fail Safe and Fail Secure 12VDC PSU Positive, Link to Door Relay Common COM Brown Lock Relay, Link to PSU Positive N/O Orange Lock Relay, Connect Positive Supply from Lock Only if Fail Secure N/C Green Lock Relay, Connect Positive Suply from Lock Only if Fail safe Either/Or PSU Return Feed Blue Yellow Exit Button Pair MOV LOCK Note: 1) The lock must also be fitted with the MOV supplied. 2) The RiteKey must be earthed. 3

User Manual for RiteKey 30-01/02 Glossary of Terms Master Code The code used for programming the user codes and any changes to the default settings of the keypad. User Code The access code given to an individual user that will allow entry to the building but does not allow the user to change any of the codes or default settings. Duration of Door Unlocked Mode The period of time that can be set between 01 and 99 seconds for which the electrical locking hardware can be unlocked to allow entry to the building. Duration of Door Latched Mode The period of time that can be set between 01 and 99 minutes for which the electrical locking hardware can be held in the unlocked position. This feature is activated by entering the user code followed by 0 and is useful on occasions such as deliveries. Operating Mode Once the user code has been entered the unit will switch for the duration of the Door Unlocked Setting to allow entry to the building and the green LED will flash at a rate of one per second. An incorrect code will result in the red LED flashing once and the unit will return to standby. Standby Mode The Mode in which the keypad is not in use and the function to which it returns after it has completed an operation. Or if an operation is not concluded a period of time that can be adjusted from 01 to 99 seconds will lapse before the keypad reverts to standby mode. This will also occur in programming. The period of time taken to revert back to the standby mode, this can be adjusted from 1 to 99 seconds. This will also occur in programming. Duration of the Exit Button Override Mode The period of time that can be set between 01 and 99 seconds for which the electrical locking hardware can be unlocked to allow exit from the building. Setting Up 1. Factory Default Settings The Master Default Code is a 5 digit number and is factory set at 12345. The Duration of Door Unlocked Mode to unlock the electrical locking hardware is factory set at 10 seconds. The Duration of Door Latched Mode to unlock the electrical locking hardware is factory set at 10 minutes. The Exit Button Time Delay to unlock the electrical locking hardware is factory set at 10 seconds. The Duration the Exit Button Override Mode is factory set at 10 seconds. 2. Resetting the Master Code to Either 4 or 5 Digits This function only needs to be carried out if the master code is to be changed to a 4 digit code or having set a 4 digit code a change back to a 5 digit code is required. Note that using this function will erase the memory of the keypad and will therefore delete all of the User Codes from 01-50. If this function is to be carried out after initial programming, the existing User Codes should be recorded before hand. Disconnect the power to the keypad. Press either button 4 or 5 (depending on whether a 4 or 5 digit code is required and keep it pressed. Apply power to the keypad and wait until the green LED is lit before releasing the button. The red LED should now be lit. Enter the first digit of the new master code and keep it pressed until the red LED is not lit and then release. Enter the remaining digits of the new master code, the red LED should not be lit when each digit is pressed until the full code had been entered where it will light for approximately three seconds followed by the green LED flashing in standby. Write down the master code. 4

3. To Change the Master Code Enter the default or old master code and wait for the LED to come on. Enter the default or old master code for a second time and wait for the green to come on. Press keys 00 and wait for the red LED Enter the new master code and the green LED will flash in standby. Write down the new master code and keep it in a safe place. Do not use the master code as a user code. The green LED will flash in standby. 4. To Create/Change the User Code Enter the 4 or 5 digit master code and wait for the red LED to come on. Enter the master code for a second time and wait for the green LED to come on. Press any two keys i.e. 01 to 50 to store the User Code Position Number and wait for the red LED to come on. Enter the new User Code, which must consist of 4 digits for a 4 digit master code and 5 digits for a 5 digit master code. Regardless of the number of digits, do not use the master code as a user code. Do not use the same User Code for other User Code Position Numbers. Write down the new 2 digit User Code Position Number and the new 4 or 5 digit User Code number. 5. Changing the Delay for the Back to Standby Mode Enter the Master Code and wait for the red LED to come on. Enter the Master Code for a second time and wait for the green LED to come on. Enter the code 66 and the green LED should be lit. Press any two keys from 01 to 99 for the new time delay (01 being 1 second and 99 being 99 seconds). 6. To Change the Duration of Door Latched Mode Press keys 71, and the green LED will light. Press any two keys from 01 to 99 for the new time delay in minutes (01 being 1 minute and 99 being 99 minutes). 7. To Change the Duration of Door Unlocked Mode Press keys 77, and the green LED will light. Press any two keys from 01 to 99 for the new time delay in seconds (01 being 1 second and 99 being 99 seconds). 8. To Delete all User Codes from Positions 01 to 50 Press keys 88, and the red LED will light for approximately 3 seconds. 9. To Change the Duration the Exit Button Override Mode Press keys 99, and the green LED will light. Press any two keys from 01 to 99 for the new time delay in seconds (01 being 1 second and 99 being 99 seconds). 5