ControlLogix Redundant Power Supply Chassis Adapter Module

Similar documents
FlexArmor 24V dc Sinking Input Modules

FLEX I/O EtherNet/IP Adapter Module

ControlLogix DC ( V) Electronically Fused Output Module

ControlLogix DC (10-30V) Isolated Output Module

Allen-Bradley PL. ControlLogix Drive Module. Installation Instructions. (Catalog Numbers: 1756-DMD30 and 1756-DMF30)

ArmorBlock MaXum Robot I/O Cable Base and Kempf Box Plate

ControlNet PCI Communication Interface Card

ArmorBlock MaXum 4 Output Module Series B

ControlLogix Ethernet Communication Interface Module

ControlLogix Isolated Analog Voltage/Current Input Module

ControlLogix RTD Input Module

ControlLogix Thermocouple Input Module

ArmorBlock MaXum 8 Input / 8 Output Module Series B

POINT I/O Source Input Module

POINT I/O Protected Output Module

ControlLogix DeviceNet Scanner Module

EtherNet/IP Modules. Installation Instructions

Barrel Temperature Control Module

POINT I/O 120/220V ac Output Module

ControlLogix DH-485 Communications Module

dc (10 60V) Output Module

POINT I/O 2 Voltage Input Analog Module

XM-124 Standard Dynamic Measurement Module

ControlLogix-XT EtherNet/IP Bridge Module

ControlLogix Controller and Memory Board

MicroLogix 1762-IQ16 DC Input Module

POINT I/O RTD Input Module

DeviceNet CompactPCI Communication Interface Card

MicroLogix 1762-IQ32T DC Input Module

CompactBlock I/O for DeviceNet Modules Series D

FLEX Integra 4 Input Module

Digital Expansion Terminal Block CompactBlock LDX I/O

InView Marquee Message Display

MicroLogix 1762-OB32T Solid State 24V DC Source Output Module

FLEX Integra 2 Input/2 Protected Output Module

CompactLogix EtherNet/IP Web Server Module

ControlLogix EtherNet/IP Bridge Module

FLEX I/O 240V AC Digital Input and Output Modules

POINT I/O 24V DC 4-channel Discrete Input Module with Diagnostics

POINT I/O 2 Current and 2 Voltage Input Analog Modules

Analog Output Module

DeviceNet Analog Base Terminal Block CompactBlock LDX I/O

POINT I/O 120V AC Input Module

User Manual. XM ControlNet Adapter Catalog Number 1440-ACNR

POINT I/O 2 and 4 Relay Output Modules

AB PLC. CompactBlock Distributed I/O on PROFIBUS DP Series D. Installation Instructions. (Cat. No. 1791P-16B0, -0B16P, -8B8P, -4B4P, -8V8P)

POINT I/O Output Module

Ethernet Network Appliance (with Network Address Translation)

POINT I/O Synchronous Serial Interface Absolute Encoder Module

FLEX I/O Digital Input/Output Modules

Stratix 6000 Ethernet Managed Switches

FLEX I/O AC Digital Output Modules

POINT I/O 4 Channel Analog Current Output Module

POINT I/O Synchronous Serial Interface Absolute Encoder Module

POINT I/O 8 Channel High Density Current Input Module

Ethernet PLC-5 Programmable Controllers

Installation Instructions

User Manual. EtherNet/IP and ControlNet to FOUNDATION Fieldbus Linking Devices

ControlLogix ControlNet Bridge Module

1769 Compact I/O Communication Bus Expansion Cables

1769-L31 CompactLogix Controller

DeviceNet Base RTD and Thermocouple CompactBlock LDX I/O

MicroLogix 1200 Isolated Relay Output Module

FLEX I/O Digital DC Output Modules

POINT I/O 2 Current Output and 2 Voltage Output Analog Modules

Micro800 Digital Relay Output Plug-in Module

CompactLogix 5370 Controllers

ControlNet Universal PCI Communication Interface Card

PROFIBUS DP Analog, RTD and Thermocouple Base Terminal Block CompactBlock LDX I/O

Solid-State Output Module

POINT I/O EtherNet/IP Adapter

1734 POINT I/O Dual Port EtherNet/IP Adapter

ControlLogix ControlNet Interface Module

Installation Instructions

Compact I/O ASCII Module

1719 Ex I/O. Installation Instructions

POINT I/O 5V DC and 24V DC Very High Speed Counter Module

Installation Instructions

Micro820 Programmable Controllers

Remote I/O Scanner. Installation Instructions. (Catalog Number 1747-SN)

Micro820 Programmable Controllers

Micro800 8-Point Input and 8-Point Output AC Modules

Installation Instructions

Installation Instructions

MicroLogix 1762-OV32T Solid State 24V DC Sink Output Module

MicroLogix 1762-IQ32T DC Input Module

Installation Instructions

Compact 1769-OF4VI Isolated Analog Output Module

Micro830 and Micro850 Programmable Controllers

Installation Instructions

Compact 1769-OF4CI Isolated Analog Output Module

1719 Ex I/O. Installation Instructions. Original Instructions

MicroLogix 1200 Isolated Relay Output Module

PanelView Component HMI Terminals

Compact GuardLogix Controllers

Installation Instructions

Micro800 4-channel and 8-channel Analog Voltage/Current Input and Output Modules

Micro Point Programmable Controllers

POINT I/O 24V DC Expansion Power Supply

XM-440 Master Relay Module

Transcription:

Installation Instructions ControlLogix Redundant Power Supply Chassis Adapter Module Catalog Number 1756-PSCA Use this publication as a guide when installing the ControlLogix 1756-PSCA chassis adapter module. To: See page: See an Overview of the Installation Process 2 See the European Communities (EC) Directive Compliance 3 Identify the Components of a Redundant Power Supply System 4 Recognize Chassis Adapter Module Physical Features 5 Determine the Chassis Widths 6 Install the Chassis Adapter Module 8 Connect the Chassis Adapter Module to the Redundant Power Supplies 9 Replace the Chassis Adapter Module 11 See the 1756-PSCA Specifications 12 See Additional Information and Notes 12 See the Hazardous Location Information 13 The 1756-PSCA power supply chassis adapter module is a passive device designed to funnel power from one or two ControlLogix redundant power supplies to the single power connector on the ControlLogix Series B chassis (Series B only) backplane. The redundant power supply system provides additional uptime protection for chassis used in critical applications. The two remotely-mounted supplies are designed to share the current required by the chassis and are available in AC and DC versions that can be mixed or matched when used in tandem.

2 ControlLogix Redundant Power Supply Chassis Adapter Module In the event of a failure by one power supply, the remaining supply will accommodate the entire load of the chassis without disruption to chassis activity. For more information on the 1756-PA75R/A or 1756-PB75R/A redundant power supplies, see publication 1756-IN573. Overview of the Installation Process Follow these steps when installing and powering your redundant power supply chassis adapter module. 1. Install the Chassis Adapter Module 2. Connect the Chassis Adapter Module to the Redundant Power Supplies The steps are described in detail, along with other important information, throughout this installation instructions. ATTENTION! Electrostatic discharge can damage integrated circuits or semiconductors if you touch backplane connector pins. Follow these guidelines when you handle the 1756-PSCA. Touch a grounded object to discharge static potential. Do not touch the backplane connector or connector pins. If available, use a static-safe work station. When not in use, keep the power supply in its static-shield packaging.

ControlLogix Redundant Power Supply Chassis Adapter Module 3 European Communities (EC) Directive Compliance If this product has the CE mark it is approved for installation within the European Union and EEA regions. It has been designed and tested to meet the following directives. EMC Directive This product is tested to meet the Council Directive 89/336/EC Electromagnetic Compatibility (EMC) by applying the following standards, in whole or in part, documented in a technical construction file: EN 50081-2 EMC Generic Emission Standard, Part 2 Industrial Environment EN 50082-2 EMC Generic Immunity Standard, Part 2 Industrial Environment This product is intended for use in an industrial environment. Low Voltage Directive This product is tested to meet Council Directive 73/23/EEC Low Voltage, by applying the safety requirements of EN 61131-2 Programmable Controllers, Part 2 - Equipment Requirements and Tests. For specific information required by EN 61131-2, see the appropriate sections in this publication, as well as the Allen-Bradley publication Industrial Automation Wiring and Grounding Guidelines, publication 1770-4.1. Open style devices must be provided with environmental and safety protection by proper mounting in enclosures designed for specific application conditions. See NEMA Standards publication 250 and IEC publication 529, as applicable, for explanations of the degrees of protection provided by different types of enclosure.

4 ControlLogix Redundant Power Supply Chassis Adapter Module Identify the Components of a Redundant Power Supply System Catalog Number Description Quantity 1756-PA75R and/or 1756-PB75R Redundant power supply 2 1756-CPR 1756-PSCA User-supplied 1 Redundant power supply cables (Length = 0.91m [3ft]) Redundant power supply chassis adapter module Annunciator wiring (Maximum length = 10m [32.8ft]) 2 1 2 1 Optional user-provided annunciator wiring can be connected to the solid state relay on the supplies for status and troubleshooting purposes. For more information, see the Redundant Power Supply installation instructions, publication 1756-IN573. The components are shown below in a typical system configuration: 1756-PA75R/A 1756-PA75R/A 1756-CPR Annunciator wiring 1756-PSCA 42655

ControlLogix Redundant Power Supply Chassis Adapter Module 5 Recognize Chassis Adapter Module Physical Features Your power supply chassis adapter module has multiple physical features as shown below. Diagnostic status indicator Cable connectors 42683 Physical Feature Diagnostic status indicators Cable connector Description There is a power indicator. For more information on the status indicators, see page 10. The cable connectors accommodates the female end of the 1756-CPR cable. For more information, see page 9.

6 ControlLogix Redundant Power Supply Chassis Adapter Module Determine the Chassis Widths The graphics below list the width of each ControlLogix chassis type with a redundant power supply chassis adapter module installed. For more mounting information, see the ControlLogix Chassis installation instructions, publication 1756-IN080 1756-A4 7.0cm (2.76in) 15.8cm (6.22in) 18.54cm (7.3in) 42835 1756-A7 17.5cm (6.89in) 15.8cm (6.22in) 29.04cm (11.44in) 42836

ControlLogix Redundant Power Supply Chassis Adapter Module 7 14.0cm (5.51in) 1756-A10 14.0cm (5.51in) 15.8cm (6.22in) 40.54cm (15.96in) 42837 14.0cm (5.51in) 1756-A13 10.5cm (4.13in) 14.0cm (5.51in) 15.8cm (6.22in) 51.04cm (20.1in) 42838 1756-A17 14.0cm (5.51in) 13.3cm (5.24in) 14.0cm (5.51in) 13.3cm (5.24in) 15.8cm (6.22in) 66.04cm (26.0in) 42839

8 ControlLogix Redundant Power Supply Chassis Adapter Module Install the Chassis Adapter Module The chassis adapter module must be inserted on the leftmost side of a ControlLogix chassis. Follow the steps below to install the module. 1. Align the right side of the chassis adapter module with the left edge of the chassis. 42669 2. Push the module on to the chassis until the locking tabs click. 42670

ControlLogix Redundant Power Supply Chassis Adapter Module 9 Connect the Chassis Adapter Module to the Redundant Power Supplies Use the 1756-CPR cables to connect your chassis adapter module to your redundant power supplies. ATTENTION! Make sure the redundant power supply is turned off before connecting the 1756-CPR cables to the chassis adapter module or the power supply. 1. Leave a minimum of 4 in (10.2 cm) space between the left side of the chassis adapter module and the cabinet housing your control system. The 1756-CPR cable will not connect to the module in less than 4 in (10.2 cm) of space. 2. Connect the cable to the chassis adapter module. 31176-M

10 ControlLogix Redundant Power Supply Chassis Adapter Module 3. Connect the cable to the redundant power supply. 31174-M 4. Tighten the screws to hold the cables in place. Make sure you completely tighten the cable screws to hold the cable in place for the life of the product. WARNING! EXPLOSION HAZARD When used in hazardous area, do not attempt to connect or disconnect cables unless power has been removed, or the area is known to be nonhazardous. Troubleshoot the Chassis Adapter Module Your chassis uses a green status indicator (LED) to display when power is applied to the chassis. If the indicator is lit up, the chassis is receiving power from one or both of the redundant power supplies. If the indicator is OFF, the chassis is not receiving power from the redundant power supplies. In this case, check the power supplies for a reason. For troubleshooting information on the Redundant Power Supply, see the Redundant Power Supply installation instructions, publication 1756-IN573.

ControlLogix Redundant Power Supply Chassis Adapter Module 11 Replace the Chassis Adapter Module If you must replace a chassis adapter module, follow the steps below. 1. Turn power off at the redundant power supplies. 2. Disconnect the redundant power supply cables from the chassis adapter module. 3. Push the top and bottom locking tabs on the chassis adapter module to the side. 42671 4. Pull the module off the chassis. 42672 5. Install a new chassis adapter module. For more information, return to page 8 of this document and follow the directions.

12 ControlLogix Redundant Power Supply Chassis Adapter Module 1756-PSCA Specifications Location Maximum Electrical Ratings Cable Assembly Dimensions (W x H x D) Weight - approximate Environmental Conditions Operating Temperature Storage Temperature Relative Humidity Agency Certification (when product or packaging is marked) ControlLogix chassis 1.5A @ 1.2 V 4A @ 3.3 V 15A @ 5.1 V 2.8A @ 24 V 1756-CPR (Length = 0.91m [3ft]) 3.4 x 15.1 x 14.4cm (1.34 x 5.95 x 5.67in) 0.45 kg (16 oz) 0 to 60 C (32 to 140 F) -40 to 85 C (-40 to 185 F) 5 to 95% noncondensing UL Listed Industrial Control Equipment UL Listed Industrial Control Equipment for use in Class I, Div 2 Hazardous Locations UL Listed Industrial Control Equipment For Use In Hazardous Locations, Certified For Canada Certified Process Control Equipment Certified Class I, Division 2, Group A, B, C, D Approved Class I, Division 2, Group A, B, C, D Marked for all applicable directives N223 Marked for all applicable acts Additional Information and Notes The ControlLogix system must be mounted within a suitable enclosure to prevent personal injury resulting from accessibility to live parts. The interior of this enclosure must be accessible only by the use of a tool. This industrial control equipment is intended to operate in a Pollution Degree 2 environment, in overvoltage category II applications, as

ControlLogix Redundant Power Supply Chassis Adapter Module 13 defined in IEC publication 664A, at altitudes up to 2000 meters without derating. Hazardous Location Information The following information applies when operating this equipment in hazardous locations: Products marked CL I, DIV 2, GP A, B, C, D are suitable for use in Class I Division 2 Groups A, B, C, D, Hazardous Locations and nonhazardous locations only. Each product is supplied with markings on the rating nameplate indicating the hazardous location temperature code. When combining products within a system, the most adverse temperature code (lowest T number) may be used to help determine the overall temperature code of the system. Combinations of equipment in your system are subject to investigation by the local Authority Having Jurisdiction at the time of installation. WARNING! EXPLOSION HAZARD Do not disconnect equipment unless power has been removed or the area is known to be nonhazardous. Do not disconnect connections to this equipment unless power has been removed or the area is known to be nonhazardous. Secure any external connections that mate to this equipment by using screws, sliding latches, threaded connectors, or other means provided with this product. Substitution of components may impair suitability for Class I, Division 2. If this product contains batteries, they must only be changed in an area known to be nonhazardous.

14 ControlLogix Redundant Power Supply Chassis Adapter Module Informations sur l utilisation de cet équipement en environnements dangereux : Les produits marqués «CL I, DIV 2, GP A, B, C, D» ne conviennent qu à une utilisation en environnements de Classe I Division 2 Groupes A, B, C, D dangereux et non dangereux. Chaque produit est livré avec des marquages sur sa plaque d identification qui indiquent le code de température pour les environnements dangereux. Lorsque plusieurs produits sont combinés dans un système, le code de température le plus défavorable (code de température le plus faible) peut être utilisé pour déterminer le code de température global du système. Les combinaisons d équipements dans le système sont sujettes à inspection par les autorités locales qualifiées au moment de l installation. AVERTISSEMENT! RISQUE D EXPLOSION Couper le courant ou s assurer que l environnement est classé non dangereux avant de débrancher l équipement. Couper le courant ou s assurer que l environnement est classé non dangereux avant de débrancher les connecteurs. Fixer tous les connecteurs externes reliés à cet équipement à l aide de vis, loquets coulissants, connecteurs filetés ou autres moyens fournis avec ce produit. La substitution de composants peut rendre cet équipement inadapté à une utilisation en environnement de Classe 1, Division 2. S assurer que l environnement est classé non dangereux avant de changer les piles.

ControlLogix Redundant Power Supply Chassis Adapter Module 15

PN 957555-23 Supersedes Publication 1756-IN574A-EN-P - April 2001 2001 Rockwell International Corporation. Printed in USA