PDU Utility. User Manual

PDU Utility User Manual Version 3.1

Smart PDU Utility. User Manual

RPM Utility Software. User s Manual

Table of Contents. 1. Introduction Package Contents Function Installation Web Interface... 5

OPERATING MANUAL AC POWER DISTRIBUTION UNITS VIGILANT SERIES

Table Of Contents. 1. Introduction... 1

Switched XPDU. 15A Model. User & Installation Manual Xtreme Power Conversion Corporation. All rights reserved.

User Manual. Per Port Monitoring Models

Model# ANI SWH. Ver. 1.1

User Manual PDUTracker

Oct 2007 Version 1.01

Table of Contents. 1. Introduction Package Contents Function Installation Web Interface... 4

When an event such as a power failure or a low battery condition occurs,.netpower will notify users via the following ways:

User s Manual PowerPanel Shutdown Service Graceful Shutdown and Notification service to ensure power protection of your computer

Network Management Card. User Manual

User s Manual PowerPanel Shutdown Service Graceful Shutdown and Notification service to ensure power protection of your computer

Application. Contents of Package. Inspect the CyberSwitch upon receipt. The package should contain the following items:

SNMP Web Management. User s Manual

Network Management Card. User Manual

ECO PDU Power Distribution Unit

NETpower Network Interface Card Default Settings, Useful Parameters, and Operational Notes

Integrate APC Smart UPS

RPM30241EV6 RPM30242EV6 (Remote Power Manager) User s Manual

KRAMER ELECTRONICS LTD. USER GUIDE

User s Manual. Management Software for Uninterruptible Power Supply Systems

ViewPower Pro. Software. User & Installation Manual Xtreme Power Conversion Corporation. All rights reserved.


my energy. my usage. mymeter. Take control of your energy use with tools made just for you.

Super USB. User Manual. 2007, March

Version /20/2012. User Manual. AP Manager II Lite Business Class Networking

PE A/16A 8-Outlet 1U Outlet-Metered & Switched eco PDU

Remote Power Manager RPM1521E. User s Manual

PE A/16A 8-Outlet 1U Outlet-Metered & Switched eco PDU. 8 outlets. 20A (UL derated 16A) / 16A. Outlet Power Measurement

Operation Manual. SNMP/Web Card SC20G2. Detailed setting. OMRON Corporation All Rights Reserved.

D-Link Wireless Aware Smart Switching System Configuration Guide. Wireless Aware Smart Switching System

IPMI View User Guide

PN5212/PN5320/PN7212/PN7320

1 Introduction to the software

SEI DC-UPS Power Management Package Users Manual

KYOCERA Net Admin User Guide

Online Help StruxureWare Data Center Expert

ELNetWeb. Billing and Power Quality software. General Information

25.2kW 3-Phase Switched PDU, LX Platform Interface, 240V Outlets (24 C13/6 C19), Touchscreen LCD, IEC A Red 415V, 0U, TAA

Smart Install in LMS CHAPTER

User Manual. Recorder of environmental conditions THBR. Version: 2.0.2

ViewPower Pro. User s Manual. Management Software for Uninterruptible Power Supply Systems

Features and Benefits: Power IQ DCIM Monitoring Solutions

Power IQ DCIM Monitoring Version 6.2.1

Ethernet Environmental Monitoring Unit USER MANUAL

Dell Network Management Card. User's Guide. w w w. d e l l. c o m s u p p o r t. d e l l. c o m

CYBER POWER SYSTEMS, INC. INTELLIGENT PDU FIRMWARE RELEASE NOTES V1.1.4 Page 1/7

This guide details the deployment and initial configuration necessary to maximize the value of JetAdvantage Insights.

CELLTRAQ Battery Monitoring Software

Power IQ Version from Version


FLOWgate500. Software Manual. Software Manual FLOWgate500 Release 2.2. Revision number: V2.2. Manufacturer: SICK AG. Erwin-Sick-Str.

Integration with Network Management Systems. Network Management System (NMS) Integration

Web-Mon Guide. View E-Mon Web-Mon Product Page

PMAC770 LAN Module User Manual V1.0

Working with Reports. User Roles Required to Manage Reports CHAPTER

Configuring with the CMM Administration Tool

IP-based 4-/8-port Switched Power Manager IPM-4220/IPM-8220

D-View 7 Configuration Guide (Part I) D-Link Academy


EL-USB-RT INSTALLATION AND OPERATION GUIDE. electronics

CREE SMARTCAST PoE TECHNOLOGY. 68% Current Savings $ SMARTCAST MANAGER USER MANUAL VERSION: Health ADVANCED. 30 Days 30 Hours 30 Min.

Intelligent PDUs. Best in Class Outlet Density Optimal Form Factors Superior Reliability

User Manual WatchPower

Industrial Ethernet Products Management Utility

SP2+ Swing Handle Lock Manual

I. Operating System and Interface Specifications: a. O/S: Windows XP, Vista, 7, /2003/2008 Server and Linux.

Inventory Reports. Detailed Device Report CHAPTER

HWg-STE HWg-STE PoE MANUAL

LevelOne FNS-7000A. 4-bay Tower NAS w/2 Gigabit Ethernet. User`s Manual

Guide Specification for 3G Wireless Battery Monitoring System

THREE PHASE ELECTRONIC WATT-HOUR METER VSE3T

5.8kW Single-Phase Switched PDU, 208/240V Outlets (8 C13 & 6 C19), L6-30P, 15ft Cord, 2U Rack-Mount, TAA

Frequently Asked Questions

InfraSuite Device Master

SmartZone G5 Firmware Release Notes 2.2.2

User s Guide SNMPWEBCARD. Firmware Version

How to assign an IP address and access your device

Copyright 2016 IPT PDUUM Revision

User s Manual. Management Converter Chassis. Model No.: SP1386 / SP1387. World Wide Web: ;

Dominion PX Overview: Dominion PX refers to Raritan s family of intelligent power distribution units.

F. RELEASE NOTES for AP88xx Metered Rack PDU AP89xx Switched Rack PDU AP86xx Metered-by-Outlet with Switching Rack PDU

New Product Release. Integrated Intelligent Power Distribution.

Qbox User Manual. Version 7.1

Installing the Kurzweil 3000 Web License From the WEBSITE

Longshine Technologie Europe GmbH

Current Firmware Release Notes

Epson Device Admin User s Guide NPD EN

Initial configuration requirements 7. Overview 7 InfraStruXure Manager Setup Wizard 8

Expert Power Control NET 4x DIN

- 1 - Dominion PX Overview: Dominion PX refers to Raritan s family of intelligent power distribution units.

GIGABYTE Remote Management Console User s Guide. Version: 1.0

KYOCERA Net Viewer User Guide

Administrator s Guide

File Management Utility User Guide

Transcription:

PDU Utility User Manual

Table of Contents 1. Introduction... 1 2. Installation... 2 3. PDU Utility Interface... 4

1. Introduction General PDU Utility is PDU monitoring, management software. It has been designed to provide information about power conditions and status of PDU and power environment. Its functions have 1. Monitor a large amount of PDU power consumption simultaneously. 2. Group Management of a large amount of the PDU. 3. Provide power consumption chart for daily monthly or the user-defined period report. 4. Send the email and trap to the specific account when the power event occurs. 5. Forward the trap to the user-defined account. 6. Events can be logged and exported to the Syslog server. 1

2. Installation Install procedure: CD Auto play screen. Please install the software step by step. Note: 1. It will take several minutes if your operation system had not been installed Microsoft.NET Framework yet. 2. Recommend that install the PDU Utility to the server level of Windows operation system. 3. If install utility under Windows Vista OS, you must first go to the folder of PDU and select the Properties of PDU.exe, shown as below to check the Run this program as an administrator. Then the utility will work normally. 2

First time to use PDU software, you must select what kind of database that you want to record the PDU information. The default database is set to Microsoft Access. If you want to use MySQL database, you may download it from http://www.mysql.org 3

3. PDU Utility Interface Start The Login Screen. The default User Name is admin, Password is 1234. 4

Easy Mode: Display all power information by graphic interface. Note: If it is the first time to use the PDU utility, please enter Expert Mode to setup the utility in advance. 1 5 2 3 4 6 System Information: 1. User can choose the PDU that want to monitor by Selection. It will display PDU name, Model Number and this PDU IP address. Power Information: 2. Graphic display for the PDU information. 3. Selection area, use can monitor PDU by selecting Current, Temperature, Humidity, Watt and Voltage when the button light with green color. Energy Information: 4. Provide quick look by selecting Today, This Month and Total for the following information. a. Main Energy that unit is kwh. b. Carbon Emission Data that unit is kg. c. Rate unit is $ for Reference. Data Log and Report: 5. Provide Data and Event log. Data log provide 3 different charts- Current, kwh and Voltage. 5

PDU Status: 6. Provide all PDU status that monitored by PDU utility, included Normal, Warning, Overload, Out of Reach. Expert Mode: Click to enter Expert Mode. 6

Expert Mode: Display all power information by table and txt interface. Provide more detail information. Function Menu PDU List PDU Information PDU Status Summary 1. Function Menu: PDU Utility functions bar. 2. PDU List: List all the PDU in the network; user can define the group to easily manage a large amount of the PDU. 3. PDU Information: This area provides all detail information about the PDU. 4. Device Summary: Indicate the status of the monitored PDU in the network. 7

Function Menu Device Add Device Administrator can add the PDU by manually if the IP address of PDU had been setup before. Device Group: SNMP Community: Select the PDU belongs to which group Set the community, it must the same with the PDU in order to communicate with it. Default setting is private Note1: This community is set for the authority of WRITE. Note2: The READ community is set to public, and user can not change. Trap forward IP: Syslog server IP: When event occurs, it can forward the event trap to the certain NMS. Forward the log to the certain Syslog server. Edit Device Administrator can redefine the PDU information here, including 8

Device Group: SNMP Community: Change the PDU belongs to which group Set the community, it must the same with the PDU. Note: This community is set for the authority of WRITE. Trap forward IP: Syslog server IP: SNMP Settings: Network Settings: Total Current Threshold Setting Change the trap receiver IP. Change the Syslog server IP. Modify the SNMP information for the PDU. Re-defined the IP address of PDU. It is only available when there is not only one PDU under this IP address. User can input the current threshold to prevent total PDUs power consumption exceed the facility capacity. ENV Threshold Setting When the temperature or humidity exceeds the pre-setting, utility will send mail to notify manager. Manager can change the method that PDU Utility to get the IP. 9

Remove Selected Device Edit PDU Config Delete the selected the IP address of PDU Modify PDU configuration. PDU Name: User defines the PDU name. Voltage: Threshold: Outlet Name: User defines the voltage.. PDU Threshold. User defines the outlet name. (Option) Remove Selected PDU Delete the selected PDU Update Device Information Update the PDU information manually. Add Device Group Create a new group. 10

The default group is named Lab. Edit Group Rename the group Remove Device Group Delete an existing group. All PDU listed under this group must be removed first. Data Management Export kw*hr Account to CSV Export power data with CSV format. Export Data Log to CSV Export current data log with CSV format. Export Events to CSV Export events data with CSV format.. Remove kw*hr Account Records Delete power consumption data. Remove Data Log Records Delete current data log. Remove Event Records Delete event log. System Management Scan Subnet Search all IP addresses of PDU that are connected under the same subnet. Procedure: 1. Select the way to scan the PDU in the network. 11

Scan network interface subnet Scan the specify subnet 2. Press the Scan Button to search all PDU devices under this subnet. 3. Checked the box of ADD that you want to add to PDU Utility. 4. Select one of the groups in the Device Group to category the PDU. 5. Select OK to finish the procedure. General Setting This setting contains two functions. 12

Mail: When the event occurs, PDU Utility can send out the email message to the pre-defined account. Rate: User can input the electricity rate to calculate the bill for reference. Temperature Unit: Switch the temperature unit between Celsius and Fahrenheit. User List Administrator can add, delete and manager all the user privilege here. User can only change the password for the Admin account. Add user User can be assigned to the authority of Read only or Read/Write. 13

Edit User: Change the password, authority for the user. Database Setting Modify the database setting. Service Control Service control. 14

Note: If the service can not start, it could be the SNMP port had been used by the other program in the Windows OS. Please close the program and then restart PDU. Easy Mode Shift to Graphic interface to monitor PDU. 15

PDU Information Group Information: List all PDU in this table and provide some important information. Device Summary Critical: Warning: Unreachable: Normal: Service Status Indicate output power of the PDU exceeds the setting of overload. Indicate output power of the PDU exceeds the setting of warning. Indicate that PDU Utility can not reach the PDU. Indicate the PDU is working normally. PDU Utility service status. When indicates Stopped, please go to System Management> Service Control to Start the service. Icon: Name: IP: Status: Indicate the PDU status by different icon. The name of PDU. The IP address of PDU Indicate the communication status with PDU Utility. 16

Update Time: Normal: The PDU Utility communicates with PDU normally. Querying: The PDU Utility is requesting data from the PDU. Communication Lost: The PDU Utility can not get data from the PDU. Warning: The power consumption of PDU exceeds the threshold of warning. Overload: The power consumption of PDU exceeds the threshold of overload. The last time of update PDU information. Device Information: Network Information: Indicate the network and system information, Including IP Address MAC Address System Name System Contact System Location Trap Forward IP: Utility can forward the trap coming from the PDU to the given IP. Syslog Forward IP: Utility can send the log to the given IP which is syslog server. General Information: Indicate the detected information from total PDU device and attached device, Including Firmware Version Temperature Humidity Total Current: If this IP lists more than one PDU, utility can provide the function to accumulate all the current consumption under this IP. Device Warning: The warning threshold for all the current consumption under this IP. Device Critical: The critical threshold for all the current consumption under this IP. 17

The connected PDU information included: Icon: ID: Name: Status: Current: Time: Warning Current Overload Current Indicate the PDU status by different icon. The identification of PDU. The name of PDU Indicate the communication status with PDU Utility. Normal: The PDU Utility communicates with PDU normally. Querying: The PDU Utility is requesting data from the PDU. Communication Lost: The PDU Utility can not get data from the PDU. Warning: The power consumption of PDU exceeds the threshold of warning. Overload: The power consumption of PDU exceeds the threshold of overload. The PDU power consumption. The current time. Display the setting of PDU for warning threshold. Display the setting of PDU for overload threshold. PDU Information: 18

PDU System Information: Provide the PDU information and status. PDU Power Information: Provide PDU power information; if the PDU support outlet control, you can click the hyperlink and enter to the PDU web page to control the outlet. Power Consumption Chart: Provide the chart for the PDU power consumption record. Administrator can check the record by Daily, Monthly, Customdefined time period. Data Log: Provide PDU current data and power record. 19

20

Events: Provide events log. 21

Report: Provide data analysis. 1. Accumulated Power 2. Average Current 3. Average Temperature 4. Average Humidity 22