Installing the Focus Motor

Similar documents
Installing the Focus Motor

IRF90 - Rotating Focuser

TCF-Lynx 2-inch Focuser Installation

Pegasus Astro Dual Motor Focus Controller v2.0

Pegasus Astro Dual Motor Focus Controller v3.0. Thank you for choosing our Dual Motor Focus Controller v3.0 (DMFCv3)

Installation and Setup Instructions. FeatherTouch ASCOM Driver

Pegasus Astro Stepper Motor Focus Controller v1.x

Seletek. Tarsier. User's manual

Artemis Focuser User Guide. S Chambers

TOC F1 Operations Manual

HitecDC Focus User Manual

Press the PEN HOME key to move the pen(s) to the outside of the chart. The pen(s) is automatically raised off the chart.

Software Setup Instructions for the Foster Control System used in the Explora Dome Observatories

For more details on CCD imaging, visit and see the Guide to CCD Imaging.

Studuino Block Programming Environment Guide

Baader SteelDrive Instruction Manual

For more details on CCD imaging, visit and see the Guide to CCD Imaging.

Mount Hub Pro v1.31 User Manual

Product User Guide PR2000. PR2000 Pressure Data Logger with LCD

REMOVE COVERS. 1. Remove three screws from the Side Panel (L). 2. Slide the Side Panel (L) backward, and raise it to remove from the printer.

PC Focus Control Operator's Guide

PD1 & PD1-HT QUICKSTART GUIDE. Remote Air Follow Focus System / High Torque System. What s Included

HOBO Motor On/Off Data Logger (UX90-004x) Manual

Smart Focus. Operator's Guide. Copyright 2013 JMI Telescopes Jim's Mobile, Inc W 14th Ave Lakewood, CO U.S.A.

Robotics 2c. The Programming Interface

WHAT YOU LL NEED TABLE OF CONTENTS. Second Shooter Plus Slider Motor Mount Camera Control Cable (or external intervalometer)

Quick Start Guide MC-III TM Flow Analyzer

CNC Controller Quick Start Guide

TCF-S Commander Help

VEX ARM Cortex -based Microcontroller and VEXnet Joystick User Guide

Heightronic 235D Assembly & Operation

HOBO Occupancy/Light Data Logger (UX90-005x/-006x) Manual

Table of Contents. Part I USB Communication. Part II User Interface. Part III User Settings (Tab Control) DFS-1000 Dataview. 2 File Menu.

For more details on CCD imaging, visit and see the Guide to CCD Imaging.

SERIES 5 TABLES/BENCH

700TSU INSTALLATION MANUAL

2x2 Video Wall - NEC P Series Displays - Installation Guide

User s Manual Computerized Focus-Smart Controller Pro (Model CFS-Pro, CFS-R)

DESIGNED & MANUFACTURED by FLOATCAM

TOC DX1-K Operations Manual

HOBO Light On/Off Data Logger (UX90-002x) Manual

APPLICATION NOTE /20/02 Getting started using IPM240-5E with a brushless motor

ProScale LCD Readout Quick Start Guide

SUM-40 OPERATING MANUAL. Ma0 DYNAMIC STRUCTURES AND MATERIALS, LLC REV

PC Spa Dashboard Control User Guide

Quick Installation Guide. English Français Español Deutsch Português Italiano Türkçe Polski Русский Česky Svenska

Upchurch Scientific Nano Flow Sensor User s Guide

TSMIU Wireless Bridge Installation and Configuration

Dynamic Perception Stage Zero Dolly Owners Manual

Modern Robotics Inc. Sensor Documentation

User Guide. Model Temperature Datalogger Kit Model Temperature and Humidity Datalogger Kit Model SW276 Datalogging Software SW276

Quick Installation Guide Direct and Transfer Thermal Printer

Parts List. The HyperStar Lens Assembly includes three pieces: HyperStar Lens Secondary Mirror Holder Counterweight

For more details on CCD imaging, visit and see the Guide to CCD Imaging.

The Radio Control Temperature Logger (RCTL) Manual For hardware version 1.0 Manual version 1.0b

LED Maintenance Instructions

HOBO Occupancy/Light Data Logger (UX90-005x/-006x) Manual

INTERFACE & SOFTWARE GUIDE

TL2-A Instructions for Use

Xi4 Quick Reference Guide

Product Overview... 3 Items Included... 3 Precautions... 4 Minimum System Requirements... 4 Software Installation... 5 Software Registration

E102 - Advanced Strain Gauge Transducer Display Interface. Contents

HIGH TEMPERATURE AIR FLOW DATA MONITORING SYSTEM OPERATING MANUAL

X-CAM A10-3H 3 Axis Gimbal for GOPRO. User Manual ( V2.00 )

For more details on CCD imaging, visit and see the Guide to CCD Imaging.

ZLog Z6R Altitude Data Recording and Monitoring System

Cut-True 29A & 29H Guillotine Cutters

Power Cable. Low-Voltage Cable

CARD PRINTER PRINTHEAD REPLACEMENT INSTRUCTIONS

25 Sport Scope Instruction Manual

ABM International, Inc. Lightning Stitch Checklist 9/13/2013

DOWNLOADING THE APP FOR APPLE PHONES: DOWNLOADING THE APP FOR ANDROID PHONES: For Android Phones go to Google Play or the Android Store.

This page outlines some of the alternate pieces that can be used for building.

The following simple procedures should be performed prior to testing the 289H M relay card:

PIECAL 322 Automated Thermocouple Calibrator Operating Instructions. Product Description. Practical Instrument Electronics

Optec Pyxis Help 1 / 56

ASTRO-PHYSICS GTO CONTROL BOX FOR SERVO DRIVE Model GTOCP1

ME 365 EXPERIMENT 3 INTRODUCTION TO LABVIEW

Connecting Your Rudder Potentiometers to The BU0836 Controller Card.

Paramount Robotic Telescope Mount Specifications

Sidewinder Pumps Inc. AC Timer/Controller

X35 Apollo System Upgrading Monitor Software & ECU Firmware Version

TEC APO 200 OWNER S MANUAL

X35 Apollo System Upgrading Monitor Software & ECU Firmware Version

Lightning Stitch Assembly

Orion Deluxe Off-Axis Guider

MassaSonic PulStar and FlatPack Series Ultrasonic Level Sensors. Serial Communications Guide

QUICK START GUIDE. Android or Windows Tablet. 1 Tower PC. Mount the RazorGage to your Own Table. Assembling the RazorGage ST with RazorGage Table

Alt-Az 'GoTo' Telescope drive and tracking system

VER Tunturi F30, E40, E45, E60, E80 & E85

Cutter Option Installation Instructions

In Chapters 4 and 6 I discussed the many options

USB-FC-110 LYNX USB FOCUS CONTROLLER USER MANUAL

Using an Astrodon MonsterMOAG with a Takahashi FSQ-106N Frank Barnes III December 15, 2007

Setup Information Panosaurus May 3, 2011

Delta T Dew Heater for CDK

The Paramount MYT Robotic Telescope Mount

Paoloni Rip Kit Installation Instructions

The Nureva Span ideation system. Installation guide. Single panoramic system

K10 Intrinsically Safe Electro-Pneumatic Positioner Operating Manual

Transcription:

The MicroTouch Wireless Autofocuser is designed to work with Feathertouch Focusers from Starlight Instruments. It allows automatic focusing with CCD and DSLR cameras. Included is FocusMax software to automatically focus the telescope for imaging. Manual focus is also possible using the hand controller. The hand control features an LCD screen for displaying a digital readout of focus position as well as information used for programming the temperature compensation feature. The MicroTouch Autofocuser is compatible with Feathertouch Crayford focusers, Feathertouch SCT MicroFocusers, and Feathertouch MicroFocusers for Takahashi and TeleVue refractors. An optional larger focus motor allows use with the Starlight Instruments 3.5 focuser. Included Parts Hand Control Wireless Receiver Focus Motor Focuser Gear Motor Connector Cable USB Cable 2 12-Volt Power Cords (AC or DC, user selected) 3 Hex-Head Wrenches MicroTouch & FocusMax Software Hand control, receiver, motor, cables

Installing the Focus Motor The following directions are illustrated using a Feathertouch SCT MicroFocuser, but the instructions are identical for any Feathertouch focuser. 1) Begin by removing both the brass fine focus and black standard focus knobs from the focuser. Use the included medium size hex-head wrench to remove the knobs. 2) Install the small brass gear onto the focus shaft. The gear goes toward the telescope, with the smaller gear hub away from the scope, as shown below. The gear should NOT quite touch the brass bearing hub on the focuser. Insert the gear all the way onto the shaft then back it off slightly. Use the small hex-head wrench to lock the gear in place. Note: The gear has a small insert to allow installation on different size focus shafts. The insert can only be removed from one side. Using one of the hex-head wrenches to push the insert out can be helpful.

3) Slide the focus motor onto the focuser. You may need to rotate the motor slightly to allow the motor gear and focuser gear to mesh. The motor can be rotated to the desired position after the gears have meshed. When installed properly, the motor will completely cover the silver portion of the focuser. Use the large hex-head wrench to lock the motor in place. Connect Wireless Receiver 4) Use the included RJ11 cable to connect the motor to the wireless receiver. The receiver stays near the telescope. Some users find it convenient to Velcro the receiver to the telescope mount. 5) The wireless receiver runs off 12-volt power. Included with the MicroTouch is a power supply, either AC or DC as selected by the user when ordering. Plug the power connector into the receiver first, then into the power source.

Using the MicroTouch Autofocuser Manually You can use the MicroTouch focuser to focus the telescope visually by using the IN and OUT buttons. This is also how you will approximately focus the telescope when using a camera, before using the autofocus routine. MicroTouch Hand Control Menus The LCD screen light turns on when the hand control is powered up. If desired, press the LIGHT button to turn the light off. Pressing MODE once displays the current ambient temperature. The default display is F. To change to C, press the SET button while the temperature is displayed. The following menus are accessed sequentially by pressing the MODE button: Temp Comp, Learning, Wireless, Motor Rev, and Reset Position. Each is described in detail below. Temp Comp This activates the Temperature Compensation feature of the MicroTouch Autofocuser. Press SET to turn this feature on. In order for the Temperature Compensation feature to work, it must learn how to compensate for changes based on the optical system being used. This is done using the Learning menu (below). There are temperature sensors in both the hand control and the wireless receiver. The correct sensor is selected automatically. In wireless mode, the temperature sensor in the receiver is used. If the MicroTouch is used in wired mode, the hand control sensor is selected. Learning The Temperature Compensation feature works by learning how much focus change is necessary to compensate for a given temperature change. For example, on a certain system, a temperature drop of 1 F might require a focus position shift of 25 counts. Therefore, if the temperature drops by 2 degrees, the focuser would move 50 counts to keep the telescope in focus. The focuser must learn the exact focus shift required for a given telescope and configuration (so adding a focal reducer, for example, would require the focuser to be recalibrated).

To activate the Learning mode, press and hold the SET button for a few seconds until the display shows Mode: Learning. The word Learning will blink while the focuser is being calibrated. The current position of the focuser is displayed. Press MODE once to view the current temperature. Wait until the temperature has changed. A temperature change of 5 F is recommended for the most accurate calibration. Once the temperature has changed, refocus the telescope (either manually or using the autofocus routine described in the next section). Return to the Learning menu and hold SET again until the display shows Mode: Idle. The temperature compensation is now set. Go to the Temp Comp menu and press SET to turn the temperature compensation on. More advanced temperature compensation control is available through the MicroTouch software. Wireless This turns the wireless communications on or off. The default for the MicroTouch Wireless Autofocuser is ON. If the hand control is connected directly to the motor, bypassing the wireless receiver for wired operation, the mode must be changed to OFF. Motor Rev This reverses the direction of the motor. Reset Position The default position of the digital readout is 30000. The range of focus is 0-60000. If the focuser is moved to either end of this range, press MODE until Reset Position? appears. Press and hold the SET button until the display blinks and resets. The position has now been reset to 30000. If a different default position is desired, it is possible to program this using the MicroTouch software (described below).

Installing the MicroTouch and FocusMax Software Load the included CD. On the CD will be two installation files, one for the MicroTouch software and one for FocusMax. The MicroTouch software installation file is called Setup. Open this file and follow the directions given to install the MicroTouch software. The program will be located in the Windows Start Menu under All Programs > Starizona > MicroTouch > MicroTouch. Open the FocusMax installer and follow the directions given to install the FocusMax software. The program will be located in the Windows Start Menu under All Programs > FocusMax. Installing the MicroTouch Hardware Drivers Connect the included USB cable to the hand control then to the computer. The Found New Hardware Wizard should appear. Select the automatic install routine. The wizard should find the included drivers and successfully install the hardware. If, for some reason, Windows cannot automatically install the hardware, you can run the hardware installer again and manually select the driver. The driver is located in the Program Files > Starizona > USB2Driver folder and is called SiUSBXp.sys.

MicroTouch Software Launch the MicroTouch software. The Setup menu is displayed. The default connection is USB2. The MicroTouch Autofocuser is backward compatible to USB1.1. If your computer only has USB1.1 ports, select USB from the drop down menu. Press Connect to connect to the MicroTouch Autofocuser. Setup Menu Actual Temp F The temperature read by the MicroTouch temperature sensor may not be exactly the same as the actual ambient temperature, due to heat given off by the electronics in the autofocuser. Note that for the temperature compensation feature, only the difference in temperature not the actual temperature is the only factor. However, if you wish the displayed temperature to be correct, you can enter the known ambient temperature in this box and the software will calculate the offset between the actual and displayed temperatures and show the actual temperature in the Temperature Compensation window.

Set Speed Delay This sets the time delay before the motor ramps up to full speed. The default is 1.0 second. This means the focus motor will begin moving slowly then accelerate to full speed after 1 second. This allows more precise manual focusing. Changing the value to 0 would eliminate any delay and the motor would turn full speed immediately upon a move command. Set Steps This sets the number of steps of the motor per count of the digital display. The default is 1 step per count. For each count on the digital display the motor will move one step, i.e., pressing the IN or OUT button once will move the motor one step. There are 300 counts per revolution of the motor (and since the motor drives the 10:1 fine focus of the Feathertouch Focuser, this equals 3000 counts per revolution of the focuser). Increasing the steps per count reduces the resolution but increases the range of the focuser. For example, setting the steps per revolution to 2 cuts the resolution in half, but doubles the focus range. The count range is still 0-60000, but the equivalent range is 0-120000. It may be desirable to change the steps per count if greater focus range is needed for focusing eyepieces visually or for a focuser with a greater range of travel. Any value from 1-10 can be selected. Set Motor Speed There are two choices for motor speed, Normal and High. Normal speed turns the motor gear about once every 1 second. High speed doubles the rate of revolution. High speed allows large focus changes in less time, but it produces less torque, so heavier loads, such as a large-format CCD camera on a Crayford focuser, should always be moved at Normal speed to avoid slippage. Upgrading Firmware If new versions of the MicroTouch firmware for either the hand control or the motor control become available they can be downloaded and installed into the MicroTouch Autofocuser. To upgrade the hand control firmware, select the Hand Controller button under Upgrading Firmware. A window will display allowing you to select the firmware file. Press and hold both the IN and OUT buttons on the hand control then select the file on the computer while holding the buttons down. Release the buttons after selecting file. The LCD will display PROG MODE and the firmware will be downloaded to the hand control. To upgrade the motor controller firmware, simply click on the Motor Controller button under Upgrading Firmware and select the appropriate file in the window that appears. The upload will begin automatically.

Movement Menu The Movement menu is the main window for controlling the MicroTouch Autofocuser in manual mode. The current position of the focuser is displayed. The up and down arrows correspond to the OUT and IN buttons on the hand control, respectively. (IN decreases the count, OUT increases the count.) Target Position allows the user to select a given position and send the focuser to that position. The default position is 30000. Select the desired position and press GOTO to move the focuser to that position. Any value from 0-60000 can be selected. Pressing Reset to Target Position changes the displayed count to the Target Position. For example: The default focus position when the MicroTouch is turned on is 30000. If, after manually focusing the telescope using the IN/OUT buttons, the position reads 15000, you can enter 30000 into the Target Position, select Reset to Target Position, and the counter will be set to 30000 without moving the focuser. This sets the current position to the middle of the focus range. Any value from 0-60000 may be selected.

Stored Positions can be saved. For example, if you use a narrowband filter for imaging which significantly changes the focus position, you can find the correct focus position and save that position. For example: The telescope is focused then the counter reset to 30000. The telescope is then refocused for the filtered camera. Say the new value is 31500. This position can be saved by selecting Store under Stored Positions. In the future, after the telescope is properly focused without the filter and the counter reset to 30000, the stored position can be selected from the drop down menu and the focus position of the filtered camera selected. (Note that offset positions such as this will only be approximate as temperature changes may affect actual focus differences. Offset focus positions are still helpful for getting the telescope close to focus before running the autofocus routine.) The Halt button can be used to stop the MicroTouch focuser in the process of moving to a new position. Temperature Compensation This menu gives you control over the temperature compensation feature of the MicroTouch Autofocuser. It includes the same basic controls as the hand control, as described above, as well as additional features for more advanced control.

The current temperature is displayed in C. Turn On Learning works the same as the Learning feature in the hand control, described above. Once calibrated, the temperature coefficient (the number of counts per degree of temperature change) is displayed. This number can be manually changed by typing in a new number and selecting the New Coefficient button. This is helpful if you change between multiple systems which have previously been calibrated so that the temperature coefficients are known. Turn On Compensation activates the temperature compensation function. In this mode, temperature compensation is continuous and no manual position commands will be accepted by the focuser. Press the Turn Off Compensation button to exit this mode. A useful feature for users taking sequences of images is to only adjust focus between exposures. To do this, select Snapshot to store the current temperature and position information. After an exposure has finished, select Compensate Immediate and the focuser will move to the correct new position based on the new temperature. At the bottom of the Movement screen is a strip chart showing temperature trend. The arrow buttons at the upper left of this chart can be used to change the sample rate. The default is 5 seconds, meaning the chart will plot the temperature every five seconds. This gives a range of 6 minutes 15 seconds. Any sample rate value can be selected from 1-250 seconds. This gives a time span of 1 minute 15 seconds up to 5 hours 12 minutes 30 seconds. The chart can display a range of +/- 3 degrees. If the temperature changes by more that +/- 1 degree, the chart shifts to move the current temperature curve to the center of the graph.

Diagnostics Menu The Diagnostics window shows the current status of the MicroTouch Autofocuser and its connection to the computer. When properly connected, the Hand Controller, Motor Controller and Temperature Sensor status windows will display OK. The windows for Number of Corrupted Packets and Number of Comm. Timeouts displays the history of the communication status between the hand control and wireless receiver. Version numbers of the hand controller and motor controller firmware are displayed. See above for details on upgrading firmware.