Original operating instructions Fail-safe inductive sensor GI712S

Similar documents
Original operating instructions Fail-safe inductive sensor GG711S

Original operating instructions Fail-safe inductive sensor GF711S / / 2013

Original operating instructions Fail-safe inductive sensor GI711S / / 2010

User's Manual. english

Original operating instructions Safety relay with relay outputs with and without delay G1502S / / 2016

Original operating instructions Safety relay with relay outputs G1501S / / 2016

Original operating instructions Photoelectric safety sensors (safety light grid) with active / passive system OY90xS

Operating instructions. Speed monitor D / / 2014

Operating instructions. Switching amplifier DN0210 DN / / 2015

Operating instructions. Standstill monitor A / / 2011

Original operating instructions. Fail-safe SmartPLC with Profinet slave interface AC402S /00 06/2016

Operating instructions AS-i SmartLine module AC3200 AC /00 06/2016

SM9000. Made in Germany

PSR-MS60. Safety relay for emergency stop, safety door and light grid monitoring. Data sheet. 1 Description

Installation instructions Ethernet switch EC / / 2011

Thread length (overall length) material

Operating instructions Optical distance sensor. OID20x / / 2014

Thread length. 27 (40) mm. 27 (44) mm. 27 (40) mm. 34 (50) mm. 34 (49) mm. 39 (60) mm. 39 (54) mm. 44 (65) mm. 44 (59) mm

Operating instructions RFID evaluation unit DTE / / 2016

System manual AS-i safety monitor AC041S /00 05/2013

Operating instructions Programming and display unit PP / / 2010

SAFETY RELAY YRB-4EML-31S MAIN FEATURES

Datasheet - CSS 11-30S-D-M-ST

E2A. Ordering Information. Cylindrical Proximity Sensor. Safe Mounting with Greater Sensing Distance. E2A Cylindrical Proximity Sensor 1

Polymer Electric. Operating Instructions. Control Unit SG-EFS 1X4 ZK2/1 8k2. Version 3

Online data sheet. IN30-E0407K IN3000 Direct NON-CONTACT SAFETY SWITCHES

Operating instructions Optical distance sensor. OID20x / / 2015

Installation Sensing distance Connection Output configuration Operation mode NO Operation mode NC

Operating instructions Electronic pressure sensor. PM205x /01 09/2011

Installation Instructions Temperature transmitter TAA /00 06/2011

Datasheet - MZM 100 B ST2-1P2PW2RE-A

Operating instructions Pressure sensor. PN50xx / / 2010

Operating instructions Electronic temperature sensor TN /00 04/2011

Inductive sensor with analog output BI15-M30-LI-EXI

Datasheet - MZM 100 B ST-1P2PW2REM-A

Operating instructions Safe AS-i input module ASIM-C-M About this document. Content

Operating instructions Memory plug E /02 11/2011

Control unit SG-EFS 104/2W. EN Operating instructions. Innovative by tradition. Version SG-EFS 104/2W 24 V=/~

Operating instructions IO-Link master CabinetLine AL19xx

Operating Instructions

PSR UC/ESAM4/3X1/1X2/B

Operating instructions Optical distance sensor. OID25x / / 2015

Operating instructions Optical distance sensor. OID25x / / 2014

Operating instructions. Monitor FD / / 2013

PSR DC/ESP4/2X1/1X2

Ferrous metal (The sensing distance decreases with non-ferrous metal.) Power supply voltage (operating voltage range)

Operating instructions Control monitor for temperature sensors TR /00 04/2011

Safety Switches CES-AR/CET-AR

VM series. features. web contents. code description. available models. inductive sensors. Cylindrical M12 in AC B H

Control unit SG-EFS 104/4L. EN Operating instructions. Innovative by tradition. Version SG-EFS 104/4L AC/DC 24 V

E2Q4 Square Proximity Sensor

Operating instructions Evaluation system for flow sensors VS / / 2013

standard, short, preferential, top

Content. Sontheim Industrie Elektronik GmbH Page 2 of 15 07/2016 Installation instructions Version 1.2

Inductive angle sensor with analog output Ri360P1-DSU35TC-ELi-Exi

Operating instructions Optical distance sensor O1D / / 2012

Magnetic Field Sensor Magnetic-inductive Proximity Sensor BIM-M12E-Y1X-H1141

Operating Instructions

Technical data. Dimensions: see page 116. ): 4 kv Rated insulation voltage (U i Over-voltage category: Power supply. Rated operating voltage (Un):

Datasheet - SRB 402EM-24V

Datasheet - SRB 301LC/B-24V

Datasheet - AZM300Z-ST-1P2P-A

Diffuse reflection light scanner with background suppression. Dimensioned drawing

Thread length (overall length)

Quick reference guide 3D sensor O3D3xx

Safety System CES-FD. Non-contact safety system CES-FD- Direct connection to decentralized peripheral systems (e.g. ET200pro) PLC

GX-5SU(B) is just 5.4 mm 0.213in in diameter, the smallest in existing DC two-wire sensors. It saves you space.

Coded Non-Contact Safety Sensor Eden OSSD

Installation instructions Inclination sensor EC2019 EC / / 2013

Installation instructions Diagnostic electronics for vibration sensors VSE / / 2007

Multifunctional time delay relay MFT U31S, MFT U41SE

Safety. Detection. Control. MAGNUS RFID ENG - REV

Datasheet - RSS 36-D-R-ST

Installation instructions RF-identification system with integrated AS-i slave DTSLF / / 2010

PSR-PC50. SIL 3 coupling relay for safety-related switch on. Data sheet. 1 Description

Datasheet AZM 161 Z ST1 AS RA

XUSL4E14F046N XUSL type 4 - Finger protection - Std sensing range - Hp = 460 mm, R=14mm

AS-i Safety Relay Output Module with Diagnostic Slave

Safety coded magnetic sensor SR A series

Technical Data. General specifications. Rated operating distance s n 3 mm

SALES NUMBER NUMBER OF BEAMS PROTECTIVE HEIGHT

E2EZ-X2D1-N 2M E2EZ-X2D2-N 2M

Operating instructions Safety-monitoring module AES 1235 AES About this document. Content

XUSL4E14F121N XUSL type 4 - Finger protection - Std sensing range - Hp = 1210mm, R=14mm

Operating instructions AC010S Compact AS-i E-STOP safety module

Rhino Buffer Module PSM24-BFM600S. Operating Instructions

Safety modules. 8/4 inputs PROFIsafe S20-PSDI8/4

Online data sheet. C4C-EB10530A10000 detec SAFETY LIGHT CURTAINS

Operating instructions Optical distance sensor. O5D15x / / 2014

Modular pressure transmitters for harsh environments DST P500, DST P507 and DST P550

Electrical connection

Your Global Automation Partner. Teachable Capacitive Sensors. Operating Instructions

Monitoring technique. VARIMETER Voltage relay MK 9064N, MH 9064

Proximity Sensor Ideal for High Temperatures and Cleaning Processes. Applicable to 120 C

ILBPB24DO32. Inline Block IO Module for PROFIBUS With 32 Digital Outputs. AUTOMATIONWORX Data Sheet 6889_en_04. Description

Inductive sensor BI1.5-EG08-Y1-H1341

E-STOP relays, safety gate monitors

QUINT-BUFFER/24DC/24DC/40

Inductive sensor For rotary actuators NI4-DSU35TC-2Y1X2/S933

PSR-SCP- 24DC/SSM/2X1 PSR-SPP- 24DC/SSM/2X1

Transcription:

Original operating instructions Fail-safe inductive sensor GI712S 80236527 / 00 12 / 2016

Contents 1 Preliminary note...3 1.1 Symbols used...3 1.2 Warning signs used...3 2 Safety instructions...4 2.1 Safety-related requirements regarding the application...4 3 Items supplied...5 4 Functions and features...5 5 Function...6 5.1 Enable zone...6 6 Installation...7 6.1 Protection against simple defeating...7 7 Electrical connection...8 8 Operation...8 8.1 Switching state of the outputs...8 8.1.1 The safe state...8 8.1.2 The switched state...8 8.1.3 Output characteristics...8 8.1.4 Cross fault / short circuit...9 8.2 Response times...10 8.3 LED display... 11 9 Technical data...12 10 Troubleshooting...14 11 Maintenance, repair and disposal...14 12 Terms and abbreviations...15 2

1 Preliminary note The instructions are part of the unit. They are intended for authorised persons according to the EMC, Low Voltage and Machinery Directives and safety regulations. The instructions contain information about the correct handling of the product. Read the instructions before use to familiarise yourself with operating conditions, installation and operation. Follow the safety instructions. 1.1 Symbols used Instructions Cross-reference Important note Non-compliance can result in malfunction or interference. Information Supplementary note. LED on LED off LED flashes (2 Hz) LED flashes quickly (5 Hz) 1.2 Warning signs used WARNING Warning of serious personal injury. Death or serious irreversible injuries may result. 3

2 Safety instructions Follow the operating instructions. Improper use may result in malfunctions of the unit. This can lead to personal injury and/or damage to property during operation of the machine. For this reason note all remarks on installation and handling given in this document. Also adhere to the safety instructions for the operation of the whole installation. In case of non-observance of notes or standards, especially when tampering with and/or modifying the unit, any liability and warranty is excluded. If the sensor is damaged, the safety function cannot be guaranteed. Errors caused by damage cannot be detected by the sensor. The unit must be installed, connected and put into operation by a qualified electrician trained in safety technology. The applicable technical standards for the corresponding application must be complied with. For installation the requirements according to EN 60204 must be observed. In case of malfunction of the unit please contact the manufacturer. Tampering with the unit is not allowed. Disconnect the unit externally before handling it. Also disconnect any independently supplied relay load circuits. After installation, maintenance or repair of the system perform a complete function check. Use the unit only in specified environmental conditions ( 9 Technical data). In case of special operating conditions please contact the manufacturer. Use only as described below ( 4). 2.1 Safety-related requirements regarding the application It must be ensured that the safety requirements of the respective application correspond to the requirements stated in these instructions. 4

WARNING Failure of the safety function When used outside of the defined environmental conditions, the safety-related function of the sensor cannot be guaranteed. Use only in accordance with the defined environmental conditions ( 9 Technical data). Use of the sensor in the vicinity of chemical and biological media (solid, liquid, gaseous) as well as ionising radiation is not permitted. Observe the following requirements: Take measures to avoid metallic objects being placed on the sensing face unintentionally. Adhere to EN 14119 for interlocking devices associated with guards. Adhere to the principle of normally closed operation for all external safety circuits connected to the system. In case of faults within the fail-safe sensor which result in the defined safe state: take measures to maintain the safe state when the complete control system continues to be operated. Replace damaged units. 3 Items supplied 1 fail-safe sensor GI712S with 2 M30 fixing nuts, 1 original operating instructions GI712S, ident no. 80236527. If one of the above-mentioned components is missing or damaged, please contact one of the ifm branch offices. 4 Functions and features The fail-safe inductive sensor GI712S detects metal without contact. Safety function SF: the safe state (output stage switched off; logic "0") is achieved when undamping greater than or equal to the safe switch-off distance s ar ( 9 Technical data). Also observe the notes on installation of the sensor ( 6 Installation). The fail-safe inductive sensor is a proximity device with defined behaviour under fault conditions (PDDB) to IEC 60947-5-3. 5

The fail-safe sensor conforms to Performance Level d according to EN ISO 13849-1 as well as to the requirements SIL 2 to IEC 61508 and meets SILcl 2 to IEC 62061. The unit corresponds to the classification I1A30SP2 to IEC 60947-5-2 for nonflush installation ( 6 Installation). The fail-safe inductive sensor has been certified by TÜVNord. 5 Function "1" "0" 1: dual LED: signal (yellow); power (green) 2: close zone 3: enable zone 4: safe switch-off distance s ar 5: target 5.1 Enable zone The outputs (OSSD) are only enabled when a damping target is present in the enable zone. Outside this enable zone the outputs remain switched off. The safe switch-off distance s ar is > 15 mm. The enable zone is different if damping elements which deviate from the standard target plate in terms of material, form and size are used. Enable zone for selected materials*: Material FE360 (= mild steel) Stainless steel AIMg3G22 CuZn37 Enable zone 1...10 mm 0...7.4 mm 0...4.3 mm 0...4.6 mm 6

Material Copper Enable zone 0...3.3 mm * Typical values for damping with a reference target of 30 x 30 x 1 mm and non-flush installation to IEC 60947-5-2 at an ambient temperature of 20 C. Depending on the characteristics of the damping element there may be no close zone. 6 Installation The unit can be flush mounted according to IEC 60947-5-2, type I1A30SP2. Ensure the unit cannot work loose (tightening torque 50 Nm). Adhere to the installation conditions in accordance with the figures 1 to 3: 1 2 3 30 80 20 Tighten the socket according to the manufacturer's indications. Observe the tightening torque for the ifm socket (e.g. EVxxxx: 0.6...1.5 Nm). 6.1 Protection against simple defeating The fail-safe sensor reacts to metal objects, e.g. the frame of a safety door. Other metal objects that are not intended to enable the sensor must not be allowed to enable the fail-safe sensor unintentionally. Take measures to prevent metal objects, except the designated target, from being placed on the sensing face or in the enable zone unintentionally. 7

7 Electrical connection Disconnect power. Also disconnect any independently supplied relay load circuits. Supply voltage: connect L+ to pin 1 and L- to pin 3 of the connector. The nominal voltage is 24 V DC. This voltage may vary between 19.2 V and 30 V incl. 5 % residual ripple to EN 61131-2. In case of a single fault the supply voltage must not exceed a maximum of 40 V DC. (This requires the safe separation between power supply and transformer.) 1 L+ +24 V 2 3 A1 L IN1 GND 1 4 A2 IN2 1: safety-related logic unit * * When there is no current flow on the output stage, back feeding > 3.5 V will lead to malfunction. 8 Operation 8.1 Switching state of the outputs 8.1.1 The safe state The safe state is when at least one of the outputs A1 or A2 (OSSDs) is switched off (zero-current state: logic "0"). If one of the outputs A1 or A2 is switched off, the subsequent safety-related logic unit must bring the complete system into the state defined as safe. 8.1.2 The switched state If the damping element is in the enable zone and if there is no sensor error, both outputs A1 and A2 (OSSDs) are enabled (logic "1"). 8.1.3 Output characteristics The output characteristics are compatible with the input characteristics to EN 61131-2 type 1 or 2: 8

Logic "1" 15 V 2...15 ma 11 V 15...30 ma Logic "0" 5 V leakage current 0.2 ma The interface corresponds to interface type C class 1 according to the ZVEI position paper "Klassifizierung binärer 24-V-Schnittstellen mit Testung im Bereich der Funktionalen Sicherheit" (Classification of binary 24V interfaces tested with regard to functional safety). 8.1.4 Cross fault / short circuit A cross fault between both outputs (A1 and A2) is detected by the fail-safe sensor and results in the outputs (OSSD) being switched off at the next safety request. The outputs A1 and A2 remain switched off until the error has been removed or a voltage reset has been carried out. A cross fault (short circuit) between output A2 and the supply voltage results in the other output A1 being switched off in case of a safety request. When there is no current flow on the output stage, back feeding > 3.5 V will lead to malfunction. The device carries out self-tests for the switch-off capability on A2. 9

8.2 Response times Response time on safety request (removal from the enable zone) Response time when approaching the enable zone (enable time) Risk time / response time for safety-related faults Simultaneity of switching on and off of the outputs in case of a safety request Test pulse duration t i_max on A2 (1) Test pulse interval T on A2 (2) T typ T max T min. 10 ms 1 ms 30 ms 1 ms 1 ms 180 ms 300 ms 100 ms 1 0 t 1: Test pulse duration 2: Test pulse interval T 10

8.3 LED display LED Operating status Outputs A1 (OSSD) Signal Power A2 (OSSD) No voltage supply Both outputs switched off 0 0 Signal *1 Signal *2 Power Undervoltage 0 1 0 0 Signal Power Overvoltage Both outputs switched off 0 0 Sensor fault ( 10 Troubleshooting) Both outputs switched off 0 0 Signal Power Signal Power Damping element at safe switch-off distance from the sensor Damping element in the enable zone Damping element in the close zone or sensor fault ( 10 Troubleshooting) Both outputs switched off 0 0 Both outputs enabled 1 1 Output A2 is switched off 1 0 *1 sensor undamped, *2 sensor damped 11

9 Technical data GIIA4010-2PS/SIL2/U Inductive sensors Product characteristics Fail-safe inductive sensor Metal thread M30 x 1.5 M12 connector Enable zone 1...10 mm; [f] flush mountable Complies with the requirements: EN ISO 13849-1: 2015 category 2 PL d (can be used in applications up to cat. 3) IEC 61508: SIL 2 IEC 62061: SILcl 2 Application Type of operation Electrical data Electrical design continuous operation (maintenance-free) DC PNP Operating voltage [V] 24 DC (19.2...30 DC) Rated insulation voltage [V] 30 Current consumption [ma] < 30 Protection class Reverse polarity protection Outputs Output function 2 x OSSD (A1 and A2) Output data Interface type C class 1 Output voltage at 24 V compatible with EN 61131-2 inputs type 1, 2 Voltage drop Current rating Short-circuit protection [V] [ma] < 2.5; (30 ma) 100 yes Max. capacitive load CL_max [nf] 20 Range Enable zone [mm] 1...10 Safe switching off distance s(ar) [mm] 15 Reaction times Power-on delay time [s] 1 Response time to safety request [ms] 10 ifm electronic gmbh Friedrichstraße 1 45128 Essen GB GI712S-03 19.05.2016 III yes 12

Inductive sensors Response time when approaching [ms] the enable zone (enable time) 1 Risk time (response time for safety [ms] -related faults) 30 Environment Applications Class C to EN 60654-1 weatherproof application Ambient temperature [ C] -25...70, for service life 87600 h 10...40, for service life 175200 h Rate of temperature change [K/min] 0.5 Max. relative air humidity [%] 5...95, briefly 5...70, permanently Air pressure [kpa] 80...106 Height above sea level [m] 2000 Ionising radiation not permissible Salt spray no Protection IP 65 / IP 67 Tests / approvals EMC IEC 60947-5-2 IEC 60947-5-3 EN 60947-5-2 EN 61000-4-2 ESD: 6 kv CD / 8 kv AD EN 61000-4-3 HF radiated: 20 V/m EN 61000-4-4 Burst: 2 kv EN 61000-4-6 HF conducted: 10 V EN 61000-4-8: 30 A/m EN 55011: class B Shock resistance IEC 60947-5-2 Vibration resistance IEC 60947-5-2 Safety classification Mission time TM [h] 175200, (20 years) Safety-related reliability PFHd [1/h] 1.0E-07 Mechanical data Mounting flush mountable Housing materials Brass white bronze coated; PBT Weight [kg] 0.22 Displays / operating elements Display LED yellow (signal), LED green (power) Electrical connection Connection Wiring M12 connector; Gold-plated contacts 1: Safety-related logic unit 13

Accessories Accessories (included) Remarks Remarks 2 lock nuts Unless stated otherwise, all data refer to the 30x30x1 mm reference target plate to IEC 60947-5-2 (FE360 = mild steel) over the whole temperature range. Pack quantity [piece] 1 ifm electronic gmbh Friedrichstraße 1 45128 Essen GB GI712S-03 19.05.2016 10 Troubleshooting LED display 8.3 Problem Possible cause Troubleshooting No LED display No voltage supply Apply voltage Power LED flashes and sensor does not switch Sensor does not switch, not even after undamping and redamping No close zone Undervoltage Overvoltage Sensor was brought into the safe state (logic "0"). Cause: cross fault between both outputs A1 and A2 cross fault between output A2 and the supply voltage error in the sensor detected Due to its characteristics (material, form, size), the damping element displaces the enable zone until directly in front of the sensing face Correct the voltage ( 9 Technical data) Remove the cross fault Replace the unit If possible, change the material, form or size of the damping element ( 5.1 Enable zone) 11 Maintenance, repair and disposal If used correctly, no maintenance and repair measures are necessary. Only the manufacturer is allowed to repair the unit. After use dispose of the unit in an environmentally friendly way in accordance with the applicable national regulations. 14

12 Terms and abbreviations OSSD Output Signal Switch Device PDDB PFH (PFH D ) Proximity devices with defined behaviour under fault conditions Probability of (dangerous) Failure per Hour PL Performance Level PL to EN ISO 13849-1 SIL Safety Integrity Level SIL 1-4 to IEC 61508. The higher the SIL, the lower the probability that a safety function will fail. SIL cl Safety Integrity Level claim limit According to IEC 62061 T M Mission time Lifetime to EN 60947-5-3 (= max. service life) 15