Page 1 of 6 FXLD1218FRP5I LED FIXTURE Version 0.1 OWNERS MANUAL 08/01/2016

Similar documents
Page 1 of 6 FXLD157FRP6I2 LED FIXTURE Version 0.2 OWNERS MANUAL 3/31/2017

A double yoke enables it to be operated in several positions. receiving device and then to others in a continuous "daisy chain" fashion.

A double yoke enables the fixture to be operated in several positions.

RE-82 RACK MOUNT DIMMER OWNERS MANUAL. 8 X 2400Watts. Revision /29/2007

XC-42 OWNERS MANUAL COMPACT PORTABLE DIMMER. Revision /12/2007. Lightronics Inc. 509 Central Drive Virginia Beach, VA

AB0602D ARCHITECTURAL BALLAST DRIVER. Version Date 06/25/2012

RGBW Mini Moving Head Stage Spot Light Model: SSL1. User Manual.

w w w. p r o l i g h t. c o. u k Quad Par 64 (Order code: LEDJ46 - Black) (Order code: LEDJ47 - Polished) USER MANUAL

4. How to Connect the Fixture 3-Pin and 5-Pin XLR DMX Connectors:

StagePar COB TRI 4 CKU

Party Par. User Manual. Order codes: EQLED015 - Black housing EQLED015B - Polished housing

Performer 18 RGBWA MKII

w w w. p r o l i g h t. c o. u k TRI PAR 64 Order code: LEDJ48 - Black Order code: LEDJ49 - Polished USER MANUAL

VBAR 270. User Manual. Version 1.2

w w w. p r o l i g h t. c o. u k STAGE PAR 64

NSI DIGITAL DIMMING SYSTEM DDS 5300 / 5600 DIMMER PACK

Blitzer Strobe. User Manual. Order code: EQLED366

Performer 18 HEX. 18 x 12W 6-in-1 colour LEDs (RGBWAUV) User Manual. Order code: LEDJ252B

N-E Color Par 64 USER MANUAL

TABLE OF CONTENTS 1. Safety Instructions 2. Technical Specifications 3. Installation 4. How to Connect the Fixture 5. DMX512 Connections 6.

Blitzer RGB Strobe. User Manual. Order code: EQLED365

LED PAR56 Order Code: P56-151

UV Power Flood. User Manual. Order code: EQLED029

User Manual INTRODUCTION SAFETY INFORMATION BACK PANEL DIAGRAM. Please read the instructions carefully and before use.

LED Stage Par Light DMX wireless&battery 10-watt x 4 LEDs (R/G/B/A/W 5IN1) User s Manual

User Manual Equinox 2m Flight Cased DMX LED Flame Machine Order code: FLAM12

Microbar COB System. User Manual. Order code: EQLED137

LIGHT BRICK - 12 X 3W TRI-COLOUR

KasBar COB Tri 5. 5x15w 3in1 COB LEDs (RGB) USER MANUAL

Vector Beam White. User Manual. Order code: LEDJ265

Crossfire. User Manual. Order code: EQLED061

User Instructions. American DJ

Order code: EQLED60 USER MANUAL

Vortex. User Manual. Order code: EQLED073

SAFETY WARNINGS AND GUIDELINES

Alu HEX Par 64. (12 x 12W six-colour LEDs RGBWAUV) User Manual. Order code: ELUM114

LED PANEL. User Manual Please read the instructions carefully before use LED-7TC. Innovation, Quality, Performance 15-

User Guide. Control Box. RoscoLED TM.

Power LED Beam 56 Narrow

order code: EQLED40 user manual

Slimline CW & WW Series

10W LED PIN SPOT. User Manual LED-PS10D W. Innovation, Quality, Performance. Professional Entertainment Technology 11-

RGB Power Batten. User Manual. Order code: EQLED032

Fusion Razor Beam. 3 x 12W Moving Head User Manual. Order code: EQLED006

LED Accu Penta 9x12W RGBWAU

USER S MANUAL

Robot Light V2. User Manual

Flat Par 9 LEDs. battery power, Wirelss, Remote Control, RGBWA-UV 6-in-1 USER MANUAL. Please read over this manual before operating the light

Springtree Spatial Wash COB RGBW

LED PANEL. User Manual Please read the instructions carefully before use LED-212RGB TABLE OF CONTENTS. 1. Safety Instructions

Order code: EQLED53 User manual

HEX Par 9 MKII. Exterior Fixture User Manual. Order code: LEDJ226

Beam Stage Light (RGBW)

Colour Burst Order code: LEDJ01 USER MANUAL

K9 Lights USER MANUAL

Gobo Projector XP 80W

Fusion Saber. User Manual. Order code: EQLED070

LED Slimline PAR RGBW 7x8W

LED BEAM MOVING HEAD 12x12W Cree, 4in1, beam 8 degree

Check that the unit has not been damaged during transport

LED DANCING FLOOR User Manual

MONOPRICE. ShowPony 12-Watt LED Derby FX Light (RGBW) User's Manual P/N

LEDJ Tri LED DJ Skirt Matrix Cloth - STAR17 USER MANUAL

TourPro RGBAW Stagebar USER MANUAL

DMX LED Starcloth Systems

UV Spectra Batten 12 x 5W UV LEDs

LED W RGBA User Manual

ALO Duo Roll DMX LED barrel scanner with dual light source

DarkFX Spot 670 User Manual English

LED MOVING HEAD FLEX BEAM K8 RGBW. User Manual. Please read the instruction carefully before use

CW-WW LEDWash USER MANUAL

Spectrum Laser. User manual UK. Version 1.0

PF LED Profile. User Manual

7x15W 4IN1 Infinity Rotation LED Pixel Bar. This product manual contains important information about the safe

Blue Weapon Laser. User manual UK. Version 1.0

DMX PRO 4CH DMX DIMMER PACK USER S MANUAL

36LEDs Par Light. User Manual

Mover MicroBeam QUAD-W

ZF LED Zoom Fresnel. User Manual

Professional Entertainment Technology. imove 50SR. Innovation, Quality, Performance 21-

FOS PAR Innovative 1

MICRON DJ Booth Tri-colour Starcloth

Cobra Dimmer Master DMX Controller User Manual

Endura 1Q120 RGBW COB Exterior Fixture

SP-1500 DMX MK II Strobe

CDP 405 Digital Dimmer Pack

American DJ AVIATOR-SP8. Introduction. User Instructions

LEDMH100 USER MANUAL

BW-108. Building Wash BW-108. User Guide. Advanced LED Technology

PROFESSIONAL SHOW LIGHT

WDMX Wireless DMX Transmitter & Receiver. User s instruction manual

AL Dot User guide

DP-DMX20L 4 CHANNEL DMX DIMMER PACK. User Instructions

MATRIX LED LED User Manual Please read the instructions carefully before use

Chroma-Q Color Web PSU 10-DMX. User Manual

Professional DMX Stage Backdrop

LEDBAR1812 Outdoor 1m LED Bar 18 x 12W 6-in-1 RGB LEDs User s instruction manual

Safety. Features 1 ID: Make all the connections before you plug in the main power. DMX512 Controllable and RDM Configurable

User Instructions. American DJ Charter Street Los Angeles Ca

CS2 DMX Distribution Splitter

Transcription:

Page 1 of 6 FEATURES AND SPECIFICATIONS LEDS: 18, 12W each (RGBWA, 5 in 1) White LED Color Temperature: 8000-8500K Beam angle: 30 º Control system: DMX-512 + Stand Alone Modes DMX channels: 5/9 DMX connectors: 3 pin XLR and 5 pin XLR Refresh Rate: >3000 Hz) Voltage: 100-240 VAC 50/60Hz Max power consumption: 216 Watts Cooling: Internal Fan Body material: Die Cast Aluminum Body color: Black (White Optional) Size: 13.3"L x 11.81"W x 4.56"H (With Yoke) Weight: 16.5 lbs. (7.5 kg) DESCRIPTION The FXLD1218FRP5I is a RGBWA LED lighting fixture. It is suitable for stage, disco, night club, and other artistic applications. It has several stand-alone control modes and can operate via a DMX-512 external signal. A double yoke enables the fixture to be operated in several positions. INSTALLATION LOCATION The FXLD1218FRP5I is rated IP20 and is intended for INDOOR USE ONLY. Locate the unit in a well ventilated area away from moisture and heat. Keep the vent holes clear. Holes are provided on the yokes to install a lighting bar pipe clamp. Use a safety cable when hanging the fixture. POWER CONNECTIONS CAUTION RISK OF ELECTRIC SHOCK The FXLD1218FRP5I has a blue turn and lock connector for power input. A compatible power cable is provided for connection to a 120 VAC, 15 Amp, 60Hz, grounded service. Push the blue connector on the cable straight into the blue connector on the unit and twist approx. 1/8 turn clockwise to latch it. The white turn and lock connector on the unit is used to pass power on to another FXLD1218FRP5I unit. A mating white connector is also provided. Caution is advised since the line cord is rated for approx. 7 Amps maximum. THE SAFETY GROUND TERMINAL ON THE POWER CABLE MUST BE USED. DMX CONNECTIONS A system using DMX control should be connected as a chain of devices. In other words the control signal cable should proceed from the controller to the first receiving device and then to others in a continuous "daisy chain" fashion. The fixture has a DMX IN and a DMX OUT connector to be used to connect the chain. The control cable should NOT be split into a multiple run star arrangement with a cable running from the controller directly to each receiving device pack.

Page 2 of 6 DMX CONNECTOR PIN ASSIGNMENTS There are two different connectors generally used for DMX control. They are both XLR type connectors. Some units use 3 pin connectors. Others use 5 pin. The FXLD1218FRP5I has both. DMX can be received on either the 3 pin or 5 pin MALE connector on the back of the unit. The 3 and 5 pin FEMALE connectors are used to connect to the next DMX device on the control chain. The table below shows the pin assignments for BOTH the 3 pin and 5 pin connectors. DMX TERMINATION A DMX chain should be terminated at the last receiving device on the chain. This is done by installing a commonly available 1/4 Watt, 120 Ohm resistor across the DATA - and DATA + wires at the last device. If you have only a few fixtures very close together and a very short run to the controller then you may be able to operate without the terminator. OPERATION PIN # SIGNAL NAME 1 DMX COMMON 2 DMX DATA - 3 DMX DATA + 4 NOT USED 5 NOT USED A control panel on the back of the unit is used to set the operating options. It consists of an LED display and four buttons (MENU, UP, DOWN, and ENTER) CONTROL PANEL There are 7 operation modes: DMX 5 channel, DMX 9 channel, Color Fade, Color Change, Color Select, Manual Level (5 selections), and Demo. DMX OPERATION For DMX operation the FXLD1218FRP5I fixture can be configured as a 5 channel, or 9 channel unit. Use the dxxx (5 ch) or A.xxx (9 ch) menu to set the starting address of the unit. You can select the starting address of the unit with the UP and DOWN buttons. Detailed information on DMX channel operation is given in the tables DMX VALUES AND FUNCTIONS. MANUAL OPERATION Color Select (CS01) For additional manual operations you can use the Color Select menu (CS01) to select a color and level. Color Change (CC01) The color change mode cycles through a variety of colors at a user defined speed. Use the CC01 menu to set the rate of speed at which the colors change. The range is from 01 to 99. 99 is fastest and 01 is the slowest. COLOR FADE (CF01) The Color Fade mode cycles smoothly through a sequence of colors. Use the CS01 menu to set the speed and activate the option. The range is from 1 to 99. 99 is fastest. R, G, B, W, A MANUAL LEVEL CONTROL MENU UP DOWN ENTER Push MENU to access the operating options. When you reach the option you want to set or change - use UP or DOWN to set a value. Push ENTER to save your changes and activate the option. See the "MENU NAVIGATION" diagram for additional details. You can operate the individual color levels manually using the r000, g000, b000, E000, and Y000 menus. Use the UP and DOWN buttons to change the level, Push ENTER when done. The range is 000-255 (255 is maximum). DEMO MODE (deno) This option is currently not operable with this unit.

Page 3 of 6 MAINTENANCE AND REPAIR CAUTION DO NOT OPEN UNIT RISK OF ELECTRIC SHOCK RISK OF FIRE TROUBLESHOOTING Check that you have power applied to the unit. Check the DMX control cable. Check the address settings of the unit and the controller. CLEANING Do not use harsh chemicals or solvents when cleaning the fixture. A mild detergent can be used sparingly if needed. Ensure that the unit is completely dry before re-use. REPAIR The fixture contains a 2 Amp 250VAC, fast acting, 5mm x 20mm externally accessible fuse. Replace the fuse ONLY with the same size and type. The FXLD1218FRP5I does not contain any other user serviceable parts. Internal service on the unit by other than Lightronics authorized agents will void the warranty. If service is required, contact the dealer from whom you purchased the item, or contact the Lightronics, Service Department, 509 Central Drive, Virginia Beach, VA 23454. Tel: 757 486 3588.

Page 4 of 6 MENU NAVIGATION

Page 5 of 6 DMX VALUES AND FUNCTIONS 5 CHANNEL MODE (MODE dxxx) CHANNEL NO. FUNCTION 1 0-255 Red Level 2 0-255 Green Level 3 0-255 Blue Level 4 0-255 White Level 5 0-255 Amber Level 9 CHANNEL MODE (MODE A.XXX) CHANNEL NO. FUNCTION 1 Master Dimmer 2 Strobe Control 3 0-255 Red Level 4 0-255 Green Level 5 0-255 Blue Level 6 0-255 White Level 7 0-255 Amber Level 8 0-32 Red 33-65 Red/Green 66-96 Green/Blue 97-129 Blue/White 130-160 White/Blackout 161-191 Blackout/Amber 192-224 Amber/Red 225-255 Red/White 9 0-9 No Function 10-63 B + R Auto 64-127 R + G Auto 128-191 G + B Auto 192-239 G+R+A+B+W Auto 240-255 Random Colors

WARRANTY This product is warranted for a period of TWO YEARS from the date of purchase against defects in materials and workmanship. This warranty is subject to the following restrictions and conditions: A) If service is required, you may be asked to provide proof of purchase from an authorized Lightronics dealer. B) This warranty is valid only for the original purchaser of the unit. C) This warranty does not apply to damage resulting from abuse, misuse, accidents, shipping, and repairs or modifications by anyone other than an authorized Lightronics service representative. D) This warranty is void if the serial number is removed, altered or defaced. E) This warranty does not cover loss or damage, direct or indirect arising from the use or inability to use this product. F) Lightronics reserves the right to make any changes, modifications, or updates as deemed appropriate by Lightronics to products returned for service. Such changes may be made without prior notification to the user and without incurring any responsibility or liability for modifications or changes to equipment previously supplied. Lightronics is not responsible for supplying new equipment in accordance with any earlier specifications. G) This warranty is the only warranty either expressed, implied, or statutory, upon which the equipment is purchased. No representatives, dealers or any of their agents are authorized to make any warranties, guarantees, or representations other than expressly stated herein. H) This warranty does not cover the cost of shipping products to or from Lightronics for service. I) Lightronics Inc. reserves the right to make changes as deemed necessary to this warranty without prior notification. Lightronics Inc. 509 Central Drive Virginia Beach, VA 23454 20100211