DIMENSIONS D3200 SETUP SOFTWARE INSTRUCTION MANUAL

Similar documents
Quantum 3.2 Software. User Manual

RITIS Training Module 10 Script. To return to the Florida Analytics main page, select Florida Analytics Tools in the upper left corner of the page.

Layout and display. STILOG IST, all rights reserved

Windows Me Navigating

TMW Asset Maintenance. TMW AMS - SQL Road Calls Guide

Chat Activity. Moodle: Collaborative Activities & Blocks. Creating Chats

quick guide 1 ON OFF OFF OFF OFF

Modifying Preferences in Microsoft Outlook 2016 for the PC

Digital Display Wall Application Management Software

Tasks. User Guide 4.12

XTS36 Touch Screen X10 Lighting Control System Operating Manual

McGhee Productivity Solutions

DOWNLOAD KIT CYCLOCOMPUTER INTRODUCTION. Download unit & Download Software [e-train Data Ver.3] for Windows 98/ME/2000/XP

Welcome to Playlist, the world s easiest to use digital signage software

BRIEFCASES & TASKS ZIMBRA. Briefcase can be used to share and manage documents. Documents can be shared, edited, and created using Briefcases.

Propel PRO User Guide

RZCPG USER GUIDE 1 ON OFF 2 ON OFF 3 ON OFF 4 ON OFF

Fixed problem with InfoRecall crashing when Export Merged Documents & Print Merged Documents are chosen when files are closed.

My Site. Introduction

WinPak 2 & 2005 Quick Reference

User Guide. K V1 7/05 Rev A

Scheduling. End-User Guide 2018 Practice Engine Systems, Inc.

Windows 2000 Safe Mode

BASIC INFORMATION AND SETUP PROGRAMMING FOR THE D3208

Keynote Basics Website:

User Guide. Version

Airtime Streaming Server Programming Handbook

MultiSite Suite: General Ledger

QC-PRO Gage Management

Web Dashboard. User Manual. October Revision

ASTRA 7.5 Quick Reference Guide

User Guide Part 11. Tools and Utilities

Microsoft Outlook 2003 Microsoft screen shots used in accordance with Microsoft rules to be viewed at URL

Service Minder Plus Features/Helpful Hints

Build

DataMaster for Windows

Operating Manual. Version 7.3.4

User Guide. General Navigation

[Type text] Windows Quick Start Guide Version 3.5

Unit III: Working with Windows and Applications. Chapters 5, 7, & 8

Roxen Content Provider

NEW CEIBO DEBUGGER. Menus and Commands

New Features Overview for My Memories Suite 9

Envision Access Setup Guide

InfoSAP HC1. User s Manual

Chapter 20 Troubleshooter

PilotEdit User Manual. Author: Date: Version:

Table of Contents. Contents. 1 Introduction. 2 The Main Menu Step #2 - PM Schedule. 8 Notification Popups. 9 Service Calendar

OPUSeries Build 19 Revenue Management Operations Manual

STUDENT PORTAL VIEW LEARNING GUIDE

DAMION DISCOVERY REFERENCE GUIDE

ATS Scheduling. To schedule or edit an existing appointment, you can choose the menu option or the calendar 15 icon in the toolbar.

A quick look at the basic functions of the Hercules Programmable Controller by

User Guide Product Design Version 1.7

RITIS Training Module 9 Script

SwatCal. Swarthmore College s integrated mail and calendar system

Grievance and Arbitration System Opt Out User Guide

Copyright 2018 MakeUseOf. All Rights Reserved.

Table of Contents. Contents. 1 Introduction. 2 The Main Menu Notification Popups. 9 Service Calendar. 12 Generating Reports ...

Conditional Formatting

TA Instrument Explorer. Getting Started Guide

Public-Private Dialogue

Extranet User Instructions

[Type text] Quick Start Guide Version 3

OpenForms360 Validation User Guide Notable Solutions Inc.

Getting started with Ms Access Getting Started. Primary Key Composite Key Foreign Key

MCDOUGAL LITTELL EASYPLANNER USER S GUIDE

Houghton Mifflin Harcourt and its logo are trademarks of Houghton Mifflin Harcourt Publishing Company.

User Documentation. Administrator Manual.

My Time Off. Associates Quick-Reference Card. View Leave Balance. Request Time Off. My Time Off. Access My Time Off

RTC-Bridge User Manual

CMISGo Web v16.1 User Guide

My CLUB Navigation Tab

Nexsure Training Manual - Accounting. Chapter 15

RITIS Training Module 4 Script

Traffic Logix Radar Sign Software User Manual. *For SafePace Pro Version Manual Version 1.1

ISF Getting Started. Table of Contents

3465 Diablo Avenue, Hayward, CA U.S.A Fax:

iprism Reports Glossary Index

W-E

DATA ARCHIVING SOFTWARE V.

V-CUBE Meeting 5. User Manual V-CUBE, INC. 2015/09/01

WinDSX New Installations

Company. Business Online Banking Admin - Company. Company - Profile. Company - BAI Settings

FERGUSON BEAUREGARD. RTU-5000 Configurator User Manual

FREEDOM-Pad Installation and Operation

INTRODUCTION. InetSoft Mobile App

ATEK Intelligence Platform

Employee Guide. Page 1 of 12

Getting Started. Introduction

CPR III Manual TABLE OF CONTENTS

Business Online Banking User Guide

TS MANAGER OPERATIONS MANUAL

Contents. Getting Started...1. Managing Your Drives...9. Backing Up & Restoring Folders Synchronizing Folders...52

The following steps will allow you to install and quickly begin using DevCom2000:

Developing Interactive Lectures with PowerPoint 2007

WebEx Meeting Center User Guide

Wise Technologies Ltd.,

Chapter 10 Linking Calc Data

Pathways SM Admin. Introduction to Pathways SM Administration. Overview

Transcription:

DIMENSIONS D3200 SETUP SOFTWARE INSTRUCTION MANUAL March 10, 2003 Paul Soccoli Michael Grinshpoon

Dimensions D3200 Software Instructions Page 2 of 29 TABLE OF CONTENTS Data Manager...3 Startup Screen...3 Open Existing System: The following screen appears. Pick one of the existing files....4 New System...5 Config Device Screen...8 Config Names Tab...8 Setup Tab...9 Zone Properties window...10 Time Events Tab...10 Holiday Window...15 Scene Names Tab...16 Location Setup Screen...17 Time Zone and Location Tabs...17 Data Manager Menus...18 System menu...18 Window Menu...18 Report Menu...19 Utils Menu...19 D3200 Preferences...20 HELP Menu...20 About D3200 DM...21 Export Screen...22 Download Manager...23 Download Manager Menus...23 Download Manager Menus...24 File Menu...24 Config Window...24 Utils Menu...24 Help Menu...25 Dimmer Setup Screen...26 Advanced Functions...27 D3200 Memory Map...28

Dimensions D3200 Software Instructions Page 3 of 29 Dimensions Software Leviton provided software can be used to assist in setting up an individual Dimensions D3206 or D3208, as well as configuring a system of many D3206/8 units networked together. A device or system can be configured before or after the devices are installed. The process of setting up a device involves 3 stages. First the information must be entered into the D3200 Data Manager. The Data Manager is a database with a graphical user interface to assist the user in entering the proper information. Next, the user chooses to export certain information for downloading to the devices. Exporting is a process in which the selected information in the database is translated into a simple text format. The third step is to download the information into the D320x. The Download Manager, a separate program (included with the Data Manager) translates the simple text format into bytes the D3200 can understand. The Download Manager uses the Leviton HTTP Server to facilitate the transfer data from the Download Manger to the D3200. When using the Download Manager, the user must be sure that the Leviton HTTP Server is running. Data Manager Double-clicking on the Data Manager Icon opens up the following window: Startup Screen There are three options: Create New System, Open Existing system and Exit. Create New System: This is for starting a new system. Open Existing System: Open a system that has already been created Exit Data Manager: Exits the program

Dimensions D3200 Software Instructions Page 4 of 29 Create New System: The following screen appears, requesting a system name. All system files are saved in the c:\ \Program Files\Leviton\D3200\DB directory. The screen shows any existing systems. The user must click on the existing system, or enter the desired system name. Open Existing System: The following screen appears. Pick one of the existing files.

Dimensions D3200 Software Instructions Page 5 of 29 New System When creating a new file, the D3200 Setup screen appears. This screen is used to enter basic system information. When a new system is created, the D3200 Setup window will appear. This screen can also be accessed through the Panel Setup button. When opening an existing system, the D3200 Configuration window will appear. This window can be accessed using the Config Device button.

Dimensions D3200 Software Instructions Page 6 of 29 Panel Setup Screen

Dimensions D3200 Software Instructions Page 7 of 29 Pull down menu to choose the panel number, from Panels 1-31. Select the type of device, either a D3206 or a D3208 Enter the panel name for the Panel number chosen. Enter the name for each zone. If a D3208 is selected under panel type, the boxed area shows: The SAVE button stores all of the information into the database. The SAVE button must be used after making changes. The DEFAULT button restores the current panel s zone names to the default names. The CLOSE button closed the panel setup window without saving the data. Notes: Zone names are different for every panel. If you have multiple panels, and you want to have customized names, you must enter the zone names for each panel. Whichever zones you do not enter custom names for will retain their default name. Choosing the Panel number from the pull down list tells the software which panel you are currently working with. However, before downloading the information to the actual devices, they must have their panel numbers programmed. Programming a device s panel number must be done through the menu screen on the device. Only 16 characters are allowed for all names.

Dimensions D3200 Software Instructions Page 8 of 29 Config Device Screen The Config Device screen had four different tabs. The tabs are: Config Names, Setup, Time Events, and Scene Names. Config Names Tab This screen is used add/remove and customize the configuration names. For example, Wedding, Conference, etc This screen should not be used unless there is a D3208 in the system. The NUM column indicates the configuration number The arrow indicates which row is the active row for entering text The SAVE button stores all of the information into the database. The SAVE button must be used after making changes. Notes: After entering a name, press the up, or down arrow to navigate to adjacent rows. There are 255 possible configurations. Only provide names for the configurations you are using. Download time increases with each additional configuration used.

Dimensions D3200 Software Instructions Page 9 of 29 Setup Tab The Setup Tab is used to make zone settings, including zone names, channel mapping, group, zone type, load type, minimum level, and enable or disable the auxiliary channels. When this screen is first opened, everything is grayed out. You must choose the panel from the Panel Name box. Once the panel is chosen, the zone names will appear. If the panel chosen is a D3206, then the Configuration name box will remain grayed out. If the panel chosen is a D3208, then you must choose for which configuration you want to make settings. Once the configuration is chosen, the rest of the screen will become active. The Zone names that are entered and saved in the Panel setup window appear here. You can also edit the names here. The Panel Name pull down list shows all 31 panels, displaying any custom names that were entered in the Panel Setup screen. The active panel is displayed in the window. The Configuration Name pull down list shows only the configurations that were named in the Config Names tab. The active configuration is displayed in the window. The Save Configuration button stores all of the information into the database. The SAVE button must be used to apply the changes. The last two rows are active for D3208 panels. Otherwise, they are grayed out. These icons show the channel mapping. See direction below to change a channel mapping. The dimmers represent channel controls, and the light bulbs represent the load terminal. These buttons are used to make zone (dimmer) settings. Pressing this button will open a new window. These check boxes enable or disable the auxiliary zones for a D3208. Channel Mapping: To change a channel mapping, follow these steps: a. Click on the channel control (dimmer icon) to change. Notice it turns Yellow.

Dimensions D3200 Software Instructions Page 10 of 29 b. Now click on the load terminal (light bulb icon) that should be controlled by the channel control chosen. c. A new line will form between the two. Notes: In the case of duplicate links, the previous connection is removed. The Disconnect Zone button can also be used to remove a connection between a channel and a zone. Zone Properties window This button parameters can be set. will access the Zone Properties window in which a zone s individual Pull down list to choose which group this zone is part of. Pull down list to select Load Type. If the Zone is set as a dimmer, select either an incandescent or Fluorescent Mark X dimmer. Pull down list to select Zone Type. Set this zone to act as either a dimmer or a switched load Set the minimum level for the zone. Notes: When the Load Type is set to Fluorescent, the minimum level will be adjusted to 29%, which corresponds to 56V on the output, as per the spec for the Mark X ballast. Press the OK button to close the window. The OK button will not save the information entered. When complete, press the Save Configuration button on the Setup tab to save these settings. Time Events Tab This window is for Time Events, or Timers. Timers can be created, sorted, edited removed and printed. This window is also used to access the holiday setup window. When the Time Events Tab is selected, the panel selection for Timers screen shown below comes up. Timers must be entered for a specific panel. All Timers should only be created for a single panel. Timers should NOT be duplicated among multiple panels.

Dimensions D3200 Software Instructions Page 11 of 29 Choose from the pull down list which panel to create Timers for. Once the panel to work with is chosen, the Timer entry screen will appear. Notes: Start by choosing which panel to create the Timers for. Next, enter the Timer name, status, action timer type, Time setup and time. When this information is entered, press the Add button. Press the Save button to save the Timer. A Timer cannot be added to the list until all of the informatio is entered. To edit a Timer already in the Time Events list, select the Timer by clicking on the row the Time event occupies in the list. This Timer s information will appear in the Timer entry area. Make the mecessary changes, and press the Edit button. The changes will show in the Time Event list. Press the Save button to save the changes.

Dimensions D3200 Software Instructions Page 12 of 29 To print The list of Time Events in the Time Event list can be printed for reference. With the D3200 Configuration window open, go to the Report menu and click on Print Events. Time Events List. Scroll down to see all Timers Pull down list of panels. Choose which panel to enter the Timers for. Change the size of the columns, or sort the list by column. Press this button to open the Holiday window Timer entry area

Dimensions D3200 Software Instructions Page 13 of 29 Enter the Timer name here Pull down list to select Timer type. Choose from: One Time, Daily, Weekdays, Weekends, Weekly or Holidays. Pull down list to select Time of Day, Dawn or Dusk. After all data has been entered in the Timer Entry Area, press Add to add the Timer to the list. Click on a Timer in the Time Event list, make changes in the Timer entry area, and press Edit. Click on a Timer in the Time Event List, and press Remove. Pull down list to select the action desired. Choose from Scenes 1-32, Max and Off. For Time of Day, enter Time. For Dawn or Dusk, enter offset. Saves all Timers. Removes all Timers from the Time Event List Pull down list of status options. Choose from enable, disable and delete. Example of Timer Type: One Time Timer: One Time Shows the chosen date Clicking on the down arrow in the Date area opens a calendar window for date selection.

Dimensions D3200 Software Instructions Page 14 of 29 Example of Time Setup: Dawn Time Setup: Dawn Offset settings: Pull down list for choosing + or Scrolling arrow buttons for selecting hours (h) and minutes (m)

Dimensions D3200 Software Instructions Page 15 of 29 Holiday Window Holidays can be created through this window. The holiday window can be opened either through the Utils menu, or the Holidays button in the Time Events tab. Holidays can be printed in the same manner as Time Events. After entering the Holiday information, press Add to add the Holiday to the list. Holiday List. Scroll down to see all Holidays. Click on a Holiday in the list, make changes in the Holiday entry area, and press Edit. Click on a Holiday in the List, and press Remove. Enter the Holiday name here Removes all Holidays from the List Enter the Date. Scroll through the months or days. Pull down list of status options. Choose from enable, disable and delete. Holiday entry area Saves all Holidays.

Dimensions D3200 Software Instructions Page 16 of 29 Scene Names Tab Scene names can be entered for the first 16 scenes of each group. Only 16 characters are allowed per name. Pull down list to select group. Choose the group to enter scene names for. The NUM column indicates the Scene number The pencil indicates which row is the active row for entering text The Save button stores all of the information into the database. The Save button must be used after making changes.

Dimensions D3200 Software Instructions Page 17 of 29 Location Setup Screen The location setup screen is used to program the time zone, latitude and longitude. It contains the Time Zone and Location Tabs. Time Zone and Location Tabs The Save button saves all settings. Pull down list for selecting the Time Zone. Choose the appropriate Time zone from the list. Check the box to program the device to automatically adjust for daylight savings. Note: Daylight savings auto adjust is automatically checked for locations that comply. Uncheck the box to NOT automatically adjust. The Save button saves all settings. Pull down list for selecting the State. Choose the appropriate State from the list. The latitude and longitude of the chosen city will appear here. Pull down list for selecting the City. Choose the appropriate city from the list. Only cities in the selected state will appear.

Dimensions D3200 Software Instructions Page 18 of 29 Data Manager Menus The menu bar contains the following menus: System, Window, Utils, Reports and Help. System menu The system menu offers the options of New, Open, Save As and Exit. These are general system manipulation functions similar to any other windows based program. The New menu is the same function as the New button in the toolbar. New will close an existing system file, if open, and create a new one. The Save As screen will appear for entering the name of the new system file. The Open menu is the same function as the Open button in the toolbar. Open will close an existing system file, if open, and open a new one. The Open screen will appear. The Save As menu is the same function as the Save As button in the toolbar. The Save As screen will appear. This will be used when making a copy of an existing system. The Save buttons on each screen save the information entered, so there is no need for a Save menu. Exit will exit the program. Window Menu The window menu offers options to arrange the open windows. This function is similar to any standard Window based program.

Dimensions D3200 Software Instructions Page 19 of 29 Report Menu The repot menu offers options to print a list of the existing Timers or holidays. This menu will only be visible when the Config Device window is open. The report is generated as plain text. Utils Menu The Utils menu contains the options of: Setup Holidays, Download manager and D3200 Preferences. Setup Holidays opens the Holiday Setup window. Holidays can be entered as discussed in the Timers Tab. The Download Manager item will open the Download Manager. See the section on the Download Manager. D3200 Preferences will open a window to change some program settings.

Dimensions D3200 Software Instructions Page 20 of 29 D3200 Preferences This screen is for advanced use of the Download manger. Displays the current location of the download manager Opens a file navigation window to point to the Download Manager location. Displays the location of the HTTP Server (LPDS) OK closes the window, saving the changes Check this box to automatically start the Download manager after export. Cancel closes the window without saving changes It is not recommended to change the location of the Download Manager. If necessary, first move the Download Manager executable file to the desired location, then using the file navigation button, point to the new location. If the HTTP Server (LPDS) must be run on a different computer, the name must be entered here. The HTTP Server Location line may look like this: HTTP://server_computer_name:Port number/leviton Where server_computer_name is the network name of the computer running the HTTP Server software, and Port number is the HTTP port used if different than default (80) Un-checking the Automatically start Download Manager after export check box will force the user to manually run the Download Manager and load the INI file created after the Export function. HELP Menu The help menu offers the about screen, which provides revision information.

Dimensions D3200 Software Instructions Page 21 of 29 About D3200 DM Hyperlink points to the D3200 website to look for updates to the software or instructions. Version number. See release notes for changes by version. Database identifier

Dimensions D3200 Software Instructions Page 22 of 29 Export Screen Once all of the information about the system has been entered into the database, it must be compiled into language that can be sent to the devices. This is performed through the export screen. When an export is started, the software compiles the database into the proper format, and creates a file that is used by the download manager. This file has a.ini extension, and is saved in the: \Program Files\Leviton\D3200\INI directory Export List, includes check boxes to select which information to download to the devices. Export starts the compilation process loaded. File name for the created.ini file. The default file name is the same name as the database file. A custom name can be entered. The Cancel button closes the export window. Downloading an entire system can take a long time, which will depend on a number of factors including the speed of the PC, how much memory is installed, the number of configurations created, and if the HTTP Server is on the same computer or not. To only download specific information, the check boxes in the Export List are used. The check boxes with a + sign next to them have sub sections. a) Configuration includes configuration information (all zone settings). Configuration has a subsection called Setup. This subsection allows you to include configuration information about specific panels. Choosing a limited set of panels will speed up the download time. b) Events includes all Time Events. c) Holidays includes all Holidays. d) Panels includes panel names. Panels has a subsection to include all zone names. e) Scene names - includes all scene names. f) Time Zone & Location includes time zone, daylight savings selection, latitude and longitude. Notes: While the compilation process is happening, a window will open containing a progress bar. If the Automatically start Download Manager after export check box is checked, a window will appear when the export is complete, stating INI File load complete, and the Download Manager will open with the file already loaded.

Dimensions D3200 Software Instructions Page 23 of 29 Download Manager The Download Manager program is responsible for transferring information contained in the *.ini file to the device. The information transfer happens as follows: The Download Manager loads the *.ini file, then formats and transfers that information in pieces to the HTTP Server. The HTTP Server resends that information through the serial port to the NE100 SmartJack. The SmartJack then sends the information out on the LCnet. Whenever the Download Manager is used, the HTTP Server (LPDS) must be running. The Download Manager also contains a window from which semi-real time control of the system can be achieved. This screen, the Dimmer Setup Screen, allows programming of the date, time and scenes. Enter the panel number to download to. Start Downloading Stop Downloading Animated graphic when downloading is in process. Download progress bar. Shows the current data being downloaded, percent complete and the elapsed time (on the right) The Advanced button opens a larger window to perform more advanced functions.

Dimensions D3200 Software Instructions Page 24 of 29 Download Manager Menus The Download Manager contains the following menus., File, Utils and Help. File Menu The File menu contains the Config and Exit options. The Config option opens the Config window, and is used to modify the HTTP Server location, or the HTTP port number. The Exit selection closes the Download Manager. Config Window OK closes the window, saving the changes The Default button sets the Server URL to the default value shown. Cancel closes the window without saving changes Utils Menu The Utils window contains the options of Dimmer Setup, Load D3200 File, Download data, Upload Data, Save Image, and Load Image. Dimmer Setup opens the Dimmer Setup window, providing partial real time control of a system. Download data is the same function as the Download Data button on the screen.

Dimensions D3200 Software Instructions Page 25 of 29 The Load D3200 File opens a file open window showing the available ini files to load into the Download Manager. See the picture below. The other menu options are covered in the Advanced Functions section. Help Menu The Help menu contains the about option. Download Manager Version number OK button closes this window. Release Date and Tim. Indicates the configured Server URL

Dimensions D3200 Software Instructions Page 26 of 29 Dimmer Setup Screen The Dimmer setup screen provides patrtial real time control of a system. By choosing the panel and group, individual zones can be controlled, and scenes can be called. As with all functions of the download manager, the HTTP Server must be running. This screen can also be used to set scene levels. Pull down list of Panel numbers. Select the panel to control. Pull down list of group numbers. Select the group to control. OK button closes the Dimmer Setup Screen On button turns on the zone Sliders indicate the current level for each zone. Drag the slider to change the zone level. Off button turns off the zone Max button calls the MAX scene for the selected group Off button calls the Off scene for the selected group Set Time button programs the time and date to the panel chosen. The computer s time and date are shown in the box below. Zone information rows Set Scene check box, used to program scenes. Scene button, calls a scene for the selected group. Scene scroll. Scrolls through scene banks, 1-8,9-16, 17-24, 25-32 To operate an installed device Set the panel number and group number of the device to be controlled from panel and group pull down list. Note if the panel has zones set to different groups, only the zones belonging to the group selected from the pull down list will be controlled. Once the panel and group are set, the sliders and zone information rows will show the

Dimensions D3200 Software Instructions Page 27 of 29 current information about the device selected. If those areas remain grayed out, then check that the panel number selected match the installed device, the server is running and the SmartJack is connected to the serial port of the computer. To program the Date and Time Click on the Set Time button. All connected devices will be programmed with the date and time. The panel chosen from the pull down list will be the Time Master. For the Time Master to take effect, the device must be restarted. To program a Scene 1) Select the panel and group desired. 2) Set the levels for each individual zone. If there is more than 1 device connected on the LCnet, repeat Steps 1and 2 for all panels. 3) Click the Set Scene check box. 4) Click on the scene button corresponding to the scene number to be programmed. The check mark in the box will disappear. 5) Scene programming complete. Advanced Functions The Advanced Screen can be used to make backups of the data stored in the device memory, through the Upload Data, Load Image and Save Image selections under the Utils menu. Enter the start address from the memory map Start Uploading Enter the End Address from the memory map Memory Dump area, contains Hex data.

Dimensions D3200 Software Instructions Page 28 of 29 D3200 Memory Map Memory Area Description Start Address Length End Address Scene Fade 0x8040 0x0800 0x8840 Scene Controller 0x8840 0x0100 0x8940 Zone Page List 0x8940 0x400 0x8D40 Panel Name 0x8D40 0x200 0x8F40 Zone Name 0x8F40 0x1000 0x9F40 Auxiliary 0x9F40 0x0008 0x9F48 Configuration Names 0x9F48 0x1000 0xAF48 Holidays 0xAF48 0x0800 0xB748 Events 0xB748 0x0800 0xBF48 IR 0xBF48 0x0048 0xBF90 Scene Names 0xC000 0x4000 0x10000

Dimensions D3200 Software Instructions Page 29 of 29 When creating a new system: Start by giving a name to each panel in the system. For every panel: Set whether it is a D3206 or a D3208 Enter zone names for all Zones used If the system requires partitioning, enter names for all of the configurations needed. Displays the current location of the download manager Displays the location of the HTTP Server (LPDS) OK closes the window, saving the changes