Topologie Connection Concepts Samples of networking and topology options for INTUS readers and terminals and video components Issue: August 2018
reader / subterminals control level supervision level Configuration of a system for access control, time management and production data collection. Three levels 1. Supervision level Standard PC with as line supervisor, may be connected with an ERP system 2. Control level Local intelligent control units for access control and terminals for time & attendance or production data collection / machine data collection, working autonomic when fails ERP system access T&A PDC/MDC 3. Reader level Input units with RFID (barcode, chip card ), keypad or biometric sensor LBus Aug 2018 Topology INTUS 2
reader control level supervision level Networks and protocols. І Network supervisor control level Network with TCP/IP protocol access access Network Protocol TCP/IP І Network control level reader Network RS485 with LBus protocol RS485 LBus 3
PC connection: INTUS and. Connection of INTUS Terminals to an Star topology between switch and controllers / terminals INTUS 5200/5200 Compact terminal for T&A. Can control one door INTUS 5300 Compact T&A terminal. Can control one door INTUS 5500/5540/5600 T&A terminal with connection of max. 2x8 readers INTUS ACM40 Access control manager for up to 4 doors INTUS ACM80e Access control manager for up to 8 or 16 doors 10/100BaseT Switch 1 10/100BaseT cabling max. 100m 4 1 8 9 16 4
INTUS 5200 connections. Standard 1 x (10/100 BaseT) Option: Interface module 1 x LBus (not opto-decoupled) connection for 1 reader 1 x Digital Out (for 1 door strike) 2 x Digital In (for 2 contacts) DO DI DI LBus, 2 wire standard option 5
INTUS 5300 connections. Standard 1 x (10/100 BaseT) 1 x Digital Out 1 (for 1 door strike) 2 x Digital In 1 (for 2 contacts) Option: serial module 1 1 x RS485 (opto-decoupled) for host connection or 1 x V.24 (not opto-decoupled) for host connection or 1 x RS485 reader module for connection of 1 reader (depending on host interface) RS485, 2 wire V.24, 4 wire LBus, 2 wire DO DI DI 1 serial module standard option 1 not for INTUS 5300-PoE and INTUS 5300FP 6
INTUS 3460plus connections. Standard 1 x (10/100 BaseT) 2 x Digital Out (for 2 door strikes) 2 x Digital In (for 2 contacts) 2 x DO 2 x DI Option: serial module 1 1 x RS485 (opto-decoupled) for host connection or 1 x V.24 (not opto-decoupled) for host connection and/or 2 x RS485 reader module for connection of 1 reader (depending on host interface) RS485, 2 wire V.24, 4 wire LBus, 2 wire 2 x serial modules standard option 7
INTUS 5500 connections. Standard 1 x (10/100 BaseT) 2 x DO Option Interface Module 2 x Digital Out (for 2 door strikes) 2 x Digital In (for 2 contacts) Option: serial module 2 x RS485-LBus (opto-decoupled) for connection of 1-16 readers (depending on host interface) LBus, 2 wire 2 x DI 2 x serial module standard option 8
INTUS 5540 connections. Standard 1 x (10/100 BaseT) 2 x DO Option Interface Module 2 x Digital Out (for 2 door strikes) 2 x Digital In (for 2 contacts) Option: serial module 2 x RS485-LBus (opto-decoupled) for connection of 1 16 readers (depending on host interface) LBus, 2 wire 2 x DI 2 x serial module standard option 9
INTUS 5600 connections. Standard 1 x (10/100 BaseT) 2 x DO Option Interface Module 2 x Digital Out (for 2 door strikes) 2 x Digital In (for 2 contacts) Option: serial module 2 x RS485-LBus (opto-decoupled) for connection of 1 16 readers (depending on host interface LBus, 2 wire 2 x DI 2 x serial module standard option 10
INTUS ACM40 connections. Standard 1 x 10/100 BaseT 4 x Digital Out 8 x Digital In 2 x RS485 / LBus protocol 4 x Digital In, 2 x Digital Out just for system jobs 1 x switching relays (for door strike, alarm, ) Option for host connection 1 x RS485 (opto-decoupled) or 1 x V.24 (not opto-decoupled) Option for reader 2 x RS485 LBus (opto-decoupled) for one reader 4 x DO 8 x DI 2 x RS485 (LBus) 1 x ser. module (host) 2 x RS485 (LBus) 1 x bistab. relays 4 x DI/2xDO (system) standard option 11
INTUS ACM80e Rack connections. Standard 1 x 10/100 BaseT 16 x Digital Out 16 x Digital In 8 x RS485 / LBus protocol 4 x digital in, 4 x digital out only for system tasks (activating, alarm, ) Option for host connection 1 x RS485 (opto-decoupled) or 1 x V.24 (not opto-decoupled) Option for readers 1 x RS485 LBus (opto-decoupled) for connection of further 1 8 readers 16 x DO 16 x DI 8 x RS485 (LBus) 1 x ser. module (host) 1 x RS485 (LBus) 4 x DI/ 4xDO (System) standard option 12
INTUS ACM80e Wand connections. Standard 1 x 10/100 BaseT 16 x Digital Out 16 x Digital In 8 x RS485 / LBus protocol, unlocked for 4 readers 4 x digital in, 4 x digital out only for system tasks (activating, alarm, ) Option for host connection 1 x RS485 (opto-decoupled) or 1 x V.24 (not opto-decoupled) Option for readers Unlock reader 5-8 1 x RS485 LBus (opto-decoupled) for connection of further 1 8 readers 16 x DO 16 x DI 4(+4) x RS485 (LBus) 1 x ser. module (host) 1 x RS485 (LBus) 4 x DI/ 4xDO (system) standard option 13
Combined access control and time & attendance with one door. Connection of one door to the INTUS 5200 Line length: max. 10m Reader module: connection reader. If mounting the INTUS 5200 directly beside the door also the integrated reader can be used Digital Output: Connection of door strike Digital Inputs: Connection of door contact and/or frame contact Power Supply: Local power supply separately for reader and door opener RS485 (2 wire) DO: door strike DI: door contact DI: frame contact 10m PS PS 14
Access control for one door with I/O module. Connection of one door to the INTUS 5300 Line length: terminal reader: max. 10 m reader I/O module: max. 5 m I/O module: connection to reader via I 2 C bus. Digital Output: Connection of door strike Digital Inputs: Connection of door contact and/or frame contact Power Supply: Local power supply for reader, I/O Module and door strike I 2 C DI: door contact I/O-M RS485 (2 wire) LBus DI: frame contact DO: door strike PS 5m 10m 15
Access control for one door with I/O module. Connection of one door to the INTUS ACM80e Line length: ACM80e reader: max. 1.200 m reader I/O module: max. 5 m I/O Module: connection to reader via I 2 C bus. Digital Output: Connection of door strike Digital Inputs: Connection of door contact and/or frame contact Local Power Supplies: for INTUS 620/420/520IP reader 1-4 (supply also for I/O modules) and door strike I 2 C DI: door contact I/O-M RS485 (2 wire) LBus reader + I/O Module 1 4 (door 1 and 2) DI: frame contact reader + I/O Module 5 8 (door 3 and 4) DO: door strike PS 5m PS 1.200m 16
200m Combined access control and time & attendance with 8 up to 16 doors. Connection of 8 / 16 RFID readers to the INTUS 5600 Line length: max. 200m (depending on cable cross-section) LBus: Connection of 1 8 readers per LBus (max. 2 LBus) I/O Module: Connection of door strike and door contact Local Power Supplies: separately for reader (also for I/O module) and door strike 1 2... LBus 1 LBus 2 9 10... 8 I/O-M 16 PS PS 17
Two doors with enhanced safety requirements. Connection of two doors to INTUS ACM40 Enhanced safety requirement by control of the door contact and frame contact as well as additionally scanning of the fingerprints with INTUS 600FP Line length: max. 200m (depending on cable cross-section) Power Supply : INTUS 600FP and door strike by the INTUS ACM40 Control of door contacts and door opener via Digital-In / Digital-Out interfaces 200m RS485 (2 wire) LBus + supply DO: door strike + supply DI: door contact DI: frame contact 18
Two doors with very high safety requirements. Connection of two doors to the INTUS 1600PS Very high safety requirement by control of the door contact and frame contact as well as additionally authentication of the palm veins with INTUS 1600PS Line length: max. 200m 100m door INTUS PS controller 100m INTUS PS controller ACM40 Power Supply : INTUS 1600PS by the INTUS PS Controller, door opener by INTUS ACM40 Control of door contacts and door opener via Digital-In / Digital-Out interfaces 100m Cat 5 cable + supply PS- Controller DO: door opener + supply DI: door contact DI: frame contact 100m LBus INTUS ACM40 19
16 doors on several floors. Connection of four doors to four INTUS ACM40 with direct control Enhanced safety requirement by control of the door contact and frame contact as well as additionally requesting the PIN on the readers Line length: max. 200m using non-opto-decoupled readers (depending on cable cross-section) Reader: INTUS 600 with PIN keypad Power Supply: Readers and door strikes via INTUS ACM40 Control of door contacts and door opener via Digital-In / Digital-Out interfaces LBus+ supply DO+ supply DI ground 1. floor 2. floor 3. floor 20
Connection of 16 doors on two floors. Connection of eight doors each via INTUS ACM80e Wall with direct control Line length: max. 200m using non-optodecoupled readers (depending on cable crosssection) Power Supply: Readers and door strikes via INTUS ACM80e LBus+supply DO+supply DI 1. floor 2. floor 21
200m Connection of 16 doors via second LBus. Connection of additional eight doors via LBus2 of the INTUS ACM80e Point-to-point connection of the reader 1 8 via eight standard LBus interfaces Multipoint connection of reader 9 16 via the optional LBus2 interface Control of 16 door strikes and the 16 door contacts by the 16 standard Digital-In/Digital-Out interfaces Line length: max. 200m (depending on cable cross-section) Power Supply: - reader 1 8 and door strikes via INTUS ACM80e - reader 9 16 and door strikes with separately local power supply LBus+supply DO+supply DI LBus2 9 10 11 12 13 14 1 2 3 4 15 5 6 7 8 PS PS 16 22
200m Connection of 16 doors via eight LBus interfaces. Connection of 16 doors via LBus of the INTUS ACM80e Combined Point-to-point and multipoint connection of the reader 1 16 via eight standard LBus interfaces Multipoint connection: max. 8 readers on 4 LBus interfaces Control of 16 door strikes and the 16 door contacts by the 16 standard Digital- In/Digital-Out interfaces Line length: max. 200m (depending on cable cross-section) Power Supply: - reader 1 8 and door strikes via INTUS ACM80e - reader 9 16 and door strikes with local power supply 1 LBus 1 DO DI LBus 4 LBus 3 LBus 2 9 2 3 8 16 23
Access control center in a 19 rack for 32 doors. Four INTUS ACM80e in a 19 rack with PC Panel PC Patchpanels Four INTUS ACM80e access control managers USV (Uninterruptible power supply) 8 8 LBus LBus Patch Panel ACM80e Patch Panel ACM80e Patch Panel ACM80e Patch Panel LBus LBus 8 8 ACM80e UPS 24
Access control center in a 19 rack for 64 doors. Four INTUS ACM80e in a 19 rack and use of LBus2 interfaces Using the second LBus interface up to 64 readers can be connected. LBus1: with point-to-point LBus2: with multipoint 1 8 8 LBus1 9 16 LBus2 33 40 8 LBus1 41 48 LBus2 PC Patch Panel ACM80e Patch Panel ACM80e Patch Panel ACM80e Patch Panel ACM80e LBus1 LBus2 LBus1 LBus2 8 8 17 24 25 32 49 56 57 64 UPS 25
100% galvanic isolation. Potential difference in industrial environment 100% secure with large potential difference between access control manager and remote building / gate Line length: more than 1 km; depending on used technology also several kilometers possible Digital In / Digital Out for gate control by local I/O module in secure area Power Supply: local power supply of I/O module and reader P I/O >1km fiber optic PS 26
Remote gate control. Large distance reader access card Line length INTUS ACM40 gate: 150m (depending on cable cross-section) Reader: TagMaster long-distance reader Distance reader card: 2-3 m typically Power Supply: local power supply of the readers LBus DO LBus DO P PS P PS 3m 27
LBus Video documentation of critical access points. Video documentation Automatic video recording of unauthorized access attempts Control of two doors with INTUS ACM40 Pick up of the pictures from the video server starting with INTUS COM version 3.2 INTUS ACM40 Videoserver Convision NVS basic DO DI 28
Video surveillance with network cameras. CONVISION NVS 19-8 with SeeTec server CONVISION CC-7634 network camera SeeTec client CONVISION CC-7433 network camera CONVISION CC-7333 network camera 29
Reader / subterminals Control level Supervision level Video surveillance with status information. SeeTec Client SeeTec Server ADAM-6050 module 12 input / 6 output ADAM-6060 module 6 input/ 6 output DI DO DI CONVISION CC-7433 30
Video surveillance with analog and network cameras. CONVISION NVS 19-8 with SeeTec Server CONVISION CC-7634 network camera AXIS P7216 16-channel video encoder AXIS M7011 1 channel video encoder coax or 2 wire SeeTec Client analog camera analog camera Integration of existing analog cameras CONVISION CC-7433 network camera CONVISION CC-7333 network camera 31
Recommended wiring of analog cameras. AXIS M7011 video encoder 2-wire transmitter receiver 2-wire transmitter sender A.C. power supply 24V voltage adapter (for 12V cameras) ~230V RS485 control lines (for controllable cameras) outdoor installation box Cat 5 or Cat 6 cable 4 pairs of wire 32
License Plate Recognition (LPR). ARH ParkIT License plate camera SeeTec Cayuga S100/Infinity (X) SeeTec License Plate Recognition DO 33
Vehicle Access Control based on LPR. SeeTec Cayuga S100/Infinity (X) SeeTec License Plate Recognition DI ARH ParkIT license plate camera DO Access reader INTUS 620 Access control software DO DI DO Access Control Manager INTUS ACM80e 34
Attachment. Color definitions of the connection R G B light brown 255 204 102 LBus / RS485 2 wire / V.24 4 wire light green 99 198 0 DI orange 255 102 0 DO blue-grey 132 151 176 Cat5 + power (INTUS PS) blue 0 102 255 DI or DO black 0 0 0 Coax / 2 wire (analog video) purple 204 0 204 35