Topologie Connection Concepts. Samples of networking and topology options for INTUS readers and terminals and video components Issue: August 2018

Similar documents
Topologie Connection Concepts. Samples of networking and topology options for INTUS readers and terminals and video components Issue: Jan 2016

PCS and INTUS. Time and attendance recording Access control Biometrics Production data collection

Connecting a Cisco Reader Module

INTUS 1600PS Palm Vein Authentication

Technical Data sheet

SF200. Installation Guide & Quick Start Guide. 2 TFT AC Terminal Version: 1.0 Date: June 2014

F6-Fingerprint. Access Control/Reader. User Manual. F6 - Simplified Instruction. (Master Code) # (Factory default:1234) Enter the Programming Mode

INSTALLATION GUIDE 2.4 Inch TFT Terminal Time Attendance & Access Control

Quick Start Guide. GV-CS1320 Camera Access Controller

Installation Instructions (KF-2000)

Safety Precautions How to place the finger Product Contents Product PIN Diagram Product Dimensions Cables and Connectors Installation of Back Plate

Convision Systems GmbH Network Cameras

W Series. Color Screen Fingerprint & Card Time Attendance and Access Control W 1 W 2

IEI emerge MicroNode Install and Setup Guide. Contents

QUICK START GUIDE. 2.4 Inch TFT Terminal Time Attendance & Access Control

iloq S10 Online Configuration Guide

Agenda. August 23, 2017 Slide 2

PoE Professional Fingerprint and RFID Access Control

Single Door Standalone Access Control User Manual

Quick Installation Guide MAC1000/MAC1000SR STANDALONE BIOMETRIC CONTROLLER

Product Design Assessment (PDA) Certificate for Component Details

CM-110SK Standalone Keypad Installation Instructions

Standalone Keypad Access Control. User Manual. Please read the manual carefully before use this unit

Standalone Keypad Access Control. User Manual. SS-TS2000 Size:120*80*25 mm

Connecting a Cisco Output Module

ACCESS. A simple, versatile, easy-to-install access control solution. Do not knock on the heaven s door!

ACCESS CONTROL QUICK INSTALL GUIDE. tel: +44 (0) fax: +44 (0) web:

QUICK START GUIDE. 2.4 Inch Finger Vein Terminal Time Attendance & Access Control

Installation Instructions. i-net Access Control Units. Part Code: IA-PCB IA-ACB IA-ACU IA-KIT

T9 Fingerprint Machine Hardware User Manual. Date: Version: 1.1

CV-945 Stand-Alone Biometric Reader. Installation Instructions

Professional Access Control

GV-AS Controller. Installation Guide

Fast operation of IP Villa System V 1.0

128MB non-volatile flash memory; unlimited storage via remote network device.

Wiring Inside the card reader you will see a circuit board. The connections are as follows:

CV-110SPK Standalone Keypad/Prox Access Control Installation Instructions

QUICK START GUIDE FOR SC 403

Partizan PAB-FC2. Fingerprint scan time Fingerprint identification time. <0.5 s < % <0.0198% Ingress protection rating

DOOR FRAME DOOR LEAF. Potential-free contact for external: Intercom Switch. - Home automation system. = 110V AC, 60Hz

Digital Keypad Introduction

FVT/FVR20D2I1C4E INSTALLATION AND OPERATION MANUAL

INNOMETRIKS INC. Rhino Quick Start Guide

GENERAL QUICK START GUIDE

Knowledge Base Article. Integrating ISONAS Access Control System with TagMaster LR-series RFID Readers

SmartLogger1000 Quick Guide. Issue: 10 Part Number: Date: HUAWEI TECHNOLOGIES CO., LTD.

CRC220 and CRC221 INSTALLATION GUIDE. REF No.: DOC0014 ISSUE: 09

Connecting a Cisco Input Module

ZONE WING ZONE DOOR. Zone Door is an innovative, low-cost point-of-access device for controlling door hardware and door-related peripherals.

Portals 14 What is a portal? 14 Hardware 15 RS232 to RS USB to RS TCP/IP to RS Add a Serial Portal 16 Add a Network portal 16

NetGen Hardware Installation Guide. for NetGen Ethernet Door Controllers

GV-AS/EV Controller. User s Manual

Finger Vein Access Control device Quick Start Guide Version: 1.0 Date: June USB slot. USB slot

MorphoWave Tower. Quick User Guide V

RD-SR2 ACCESS SECURITY PRODUCTS LTD. Proximity Card Reader with Remote Control. User Manual

GV-EL124S Electric Strike

EZTAG3 PROXIMITY AND KEYPAD DOOR ENTRY

lumentouch SPECIFICATION SHEET Client: Project name: Order #: Type: Qty: FEATURES AND BENEFITS PACKAGE CONTENT HOW TO ORDER LTO

Quick Start Installation Guide

Contact Information WARRANTY AND SUPPORT

BIOC3 V1 USER S MANUAL. Biometric Reader v. b1

Waterproof. Keypad/Reader/Controller

PC Vision Wiring Guide

IP Intercom Systems for Homes and Apartments

Quick Start Guide. GV-Video Server

In-Sight 7010C/7200C/7400C

Installation Guide for PR311SE and PR311SE-BK v1.0 Access Controllers Rev. B

Lantech IPGC-0101DSFP. User Manual. 10/100/1000T (PoE at) to 100/1000M SFP Industrial Switch Converter

IF-80x Outdoor Terminal

GV-RK1352 and GV-R1352 Card Reader

INTRINSICALLY SAFE INSTRUMENTATION FOR HAZARDOUS AREAS

Product Overview. Revision 1.3

Encoder Firmware V User s Manual. Outdoor PTZ Camera Hardware Manual KCM /05/09.

OSM Features: Field Configurable Reader,I/O to OSDP OSDP to Panel

S-Vision. The Digital Video Surveillance System of Shuttle for Home and Office Applications

Fingerprint Access Control F1. User Manual

Professional IP Intercoms Product Reference Guide

GAFFCO UNDER VEHICLE BOMB DECTECTOR ( UVBD ) SYSTEM

Quick Start Guide. ProBio & ProFAC + ZKBioSecurity 3.0

IT monitoring. CMC III Monitoring system CMC III system representation CMC III system overview CMC III Processing Unit/Compact...

Fingerprint Door Lock OPERATOR S MANUAL

EZTAG3 PROXIMITY AND KEYPAD DOOR ENTRY

Wiring Instructions v4

P4 P5 P6. Security trigger signal 2 Purple Security trigger signal Output 6 Thin Blue Wiegand DAT: 1 Input

C5S120 Installation and Connection Guide

Section A5. Standard Telephone Entry Systems. This Price Schedule is effective April 1, Date Page Comment

EPGG001. Fieldbus Gateway RS-232 to PROFINET. Industrial Communication. Technical Data. Part Number

HVG400. Installation Guide

GKH-3011 Vault Automatic Under Vehicle Inspection System

Product comparison tables Network video

GateKeeperXpress Standalone or Networked Proximity Card Controller

ACCESS CONTROL. infinias Access Control and Integrated Video Installer s Guide

Face RFID Fingerprint Recognition Reader Sensor Fanless Touch 24/7 VESA

Product comparison tables Network video

Metra NET Network Installation Manual

Instruction Manual. Vogue. Security. Technology. Innovation 2013-V01

Parrot MULTICAN for Mini cars (part 2)

CYPRESS " " EXP SPX Expansion interface! modules EXP-2000_MAN_0314

4K DisplayPort Single Display KVM over IP Extender

Operation manual For NG BIOSINGLE Version 1.1

Transcription:

Topologie Connection Concepts Samples of networking and topology options for INTUS readers and terminals and video components Issue: August 2018

reader / subterminals control level supervision level Configuration of a system for access control, time management and production data collection. Three levels 1. Supervision level Standard PC with as line supervisor, may be connected with an ERP system 2. Control level Local intelligent control units for access control and terminals for time & attendance or production data collection / machine data collection, working autonomic when fails ERP system access T&A PDC/MDC 3. Reader level Input units with RFID (barcode, chip card ), keypad or biometric sensor LBus Aug 2018 Topology INTUS 2

reader control level supervision level Networks and protocols. І Network supervisor control level Network with TCP/IP protocol access access Network Protocol TCP/IP І Network control level reader Network RS485 with LBus protocol RS485 LBus 3

PC connection: INTUS and. Connection of INTUS Terminals to an Star topology between switch and controllers / terminals INTUS 5200/5200 Compact terminal for T&A. Can control one door INTUS 5300 Compact T&A terminal. Can control one door INTUS 5500/5540/5600 T&A terminal with connection of max. 2x8 readers INTUS ACM40 Access control manager for up to 4 doors INTUS ACM80e Access control manager for up to 8 or 16 doors 10/100BaseT Switch 1 10/100BaseT cabling max. 100m 4 1 8 9 16 4

INTUS 5200 connections. Standard 1 x (10/100 BaseT) Option: Interface module 1 x LBus (not opto-decoupled) connection for 1 reader 1 x Digital Out (for 1 door strike) 2 x Digital In (for 2 contacts) DO DI DI LBus, 2 wire standard option 5

INTUS 5300 connections. Standard 1 x (10/100 BaseT) 1 x Digital Out 1 (for 1 door strike) 2 x Digital In 1 (for 2 contacts) Option: serial module 1 1 x RS485 (opto-decoupled) for host connection or 1 x V.24 (not opto-decoupled) for host connection or 1 x RS485 reader module for connection of 1 reader (depending on host interface) RS485, 2 wire V.24, 4 wire LBus, 2 wire DO DI DI 1 serial module standard option 1 not for INTUS 5300-PoE and INTUS 5300FP 6

INTUS 3460plus connections. Standard 1 x (10/100 BaseT) 2 x Digital Out (for 2 door strikes) 2 x Digital In (for 2 contacts) 2 x DO 2 x DI Option: serial module 1 1 x RS485 (opto-decoupled) for host connection or 1 x V.24 (not opto-decoupled) for host connection and/or 2 x RS485 reader module for connection of 1 reader (depending on host interface) RS485, 2 wire V.24, 4 wire LBus, 2 wire 2 x serial modules standard option 7

INTUS 5500 connections. Standard 1 x (10/100 BaseT) 2 x DO Option Interface Module 2 x Digital Out (for 2 door strikes) 2 x Digital In (for 2 contacts) Option: serial module 2 x RS485-LBus (opto-decoupled) for connection of 1-16 readers (depending on host interface) LBus, 2 wire 2 x DI 2 x serial module standard option 8

INTUS 5540 connections. Standard 1 x (10/100 BaseT) 2 x DO Option Interface Module 2 x Digital Out (for 2 door strikes) 2 x Digital In (for 2 contacts) Option: serial module 2 x RS485-LBus (opto-decoupled) for connection of 1 16 readers (depending on host interface) LBus, 2 wire 2 x DI 2 x serial module standard option 9

INTUS 5600 connections. Standard 1 x (10/100 BaseT) 2 x DO Option Interface Module 2 x Digital Out (for 2 door strikes) 2 x Digital In (for 2 contacts) Option: serial module 2 x RS485-LBus (opto-decoupled) for connection of 1 16 readers (depending on host interface LBus, 2 wire 2 x DI 2 x serial module standard option 10

INTUS ACM40 connections. Standard 1 x 10/100 BaseT 4 x Digital Out 8 x Digital In 2 x RS485 / LBus protocol 4 x Digital In, 2 x Digital Out just for system jobs 1 x switching relays (for door strike, alarm, ) Option for host connection 1 x RS485 (opto-decoupled) or 1 x V.24 (not opto-decoupled) Option for reader 2 x RS485 LBus (opto-decoupled) for one reader 4 x DO 8 x DI 2 x RS485 (LBus) 1 x ser. module (host) 2 x RS485 (LBus) 1 x bistab. relays 4 x DI/2xDO (system) standard option 11

INTUS ACM80e Rack connections. Standard 1 x 10/100 BaseT 16 x Digital Out 16 x Digital In 8 x RS485 / LBus protocol 4 x digital in, 4 x digital out only for system tasks (activating, alarm, ) Option for host connection 1 x RS485 (opto-decoupled) or 1 x V.24 (not opto-decoupled) Option for readers 1 x RS485 LBus (opto-decoupled) for connection of further 1 8 readers 16 x DO 16 x DI 8 x RS485 (LBus) 1 x ser. module (host) 1 x RS485 (LBus) 4 x DI/ 4xDO (System) standard option 12

INTUS ACM80e Wand connections. Standard 1 x 10/100 BaseT 16 x Digital Out 16 x Digital In 8 x RS485 / LBus protocol, unlocked for 4 readers 4 x digital in, 4 x digital out only for system tasks (activating, alarm, ) Option for host connection 1 x RS485 (opto-decoupled) or 1 x V.24 (not opto-decoupled) Option for readers Unlock reader 5-8 1 x RS485 LBus (opto-decoupled) for connection of further 1 8 readers 16 x DO 16 x DI 4(+4) x RS485 (LBus) 1 x ser. module (host) 1 x RS485 (LBus) 4 x DI/ 4xDO (system) standard option 13

Combined access control and time & attendance with one door. Connection of one door to the INTUS 5200 Line length: max. 10m Reader module: connection reader. If mounting the INTUS 5200 directly beside the door also the integrated reader can be used Digital Output: Connection of door strike Digital Inputs: Connection of door contact and/or frame contact Power Supply: Local power supply separately for reader and door opener RS485 (2 wire) DO: door strike DI: door contact DI: frame contact 10m PS PS 14

Access control for one door with I/O module. Connection of one door to the INTUS 5300 Line length: terminal reader: max. 10 m reader I/O module: max. 5 m I/O module: connection to reader via I 2 C bus. Digital Output: Connection of door strike Digital Inputs: Connection of door contact and/or frame contact Power Supply: Local power supply for reader, I/O Module and door strike I 2 C DI: door contact I/O-M RS485 (2 wire) LBus DI: frame contact DO: door strike PS 5m 10m 15

Access control for one door with I/O module. Connection of one door to the INTUS ACM80e Line length: ACM80e reader: max. 1.200 m reader I/O module: max. 5 m I/O Module: connection to reader via I 2 C bus. Digital Output: Connection of door strike Digital Inputs: Connection of door contact and/or frame contact Local Power Supplies: for INTUS 620/420/520IP reader 1-4 (supply also for I/O modules) and door strike I 2 C DI: door contact I/O-M RS485 (2 wire) LBus reader + I/O Module 1 4 (door 1 and 2) DI: frame contact reader + I/O Module 5 8 (door 3 and 4) DO: door strike PS 5m PS 1.200m 16

200m Combined access control and time & attendance with 8 up to 16 doors. Connection of 8 / 16 RFID readers to the INTUS 5600 Line length: max. 200m (depending on cable cross-section) LBus: Connection of 1 8 readers per LBus (max. 2 LBus) I/O Module: Connection of door strike and door contact Local Power Supplies: separately for reader (also for I/O module) and door strike 1 2... LBus 1 LBus 2 9 10... 8 I/O-M 16 PS PS 17

Two doors with enhanced safety requirements. Connection of two doors to INTUS ACM40 Enhanced safety requirement by control of the door contact and frame contact as well as additionally scanning of the fingerprints with INTUS 600FP Line length: max. 200m (depending on cable cross-section) Power Supply : INTUS 600FP and door strike by the INTUS ACM40 Control of door contacts and door opener via Digital-In / Digital-Out interfaces 200m RS485 (2 wire) LBus + supply DO: door strike + supply DI: door contact DI: frame contact 18

Two doors with very high safety requirements. Connection of two doors to the INTUS 1600PS Very high safety requirement by control of the door contact and frame contact as well as additionally authentication of the palm veins with INTUS 1600PS Line length: max. 200m 100m door INTUS PS controller 100m INTUS PS controller ACM40 Power Supply : INTUS 1600PS by the INTUS PS Controller, door opener by INTUS ACM40 Control of door contacts and door opener via Digital-In / Digital-Out interfaces 100m Cat 5 cable + supply PS- Controller DO: door opener + supply DI: door contact DI: frame contact 100m LBus INTUS ACM40 19

16 doors on several floors. Connection of four doors to four INTUS ACM40 with direct control Enhanced safety requirement by control of the door contact and frame contact as well as additionally requesting the PIN on the readers Line length: max. 200m using non-opto-decoupled readers (depending on cable cross-section) Reader: INTUS 600 with PIN keypad Power Supply: Readers and door strikes via INTUS ACM40 Control of door contacts and door opener via Digital-In / Digital-Out interfaces LBus+ supply DO+ supply DI ground 1. floor 2. floor 3. floor 20

Connection of 16 doors on two floors. Connection of eight doors each via INTUS ACM80e Wall with direct control Line length: max. 200m using non-optodecoupled readers (depending on cable crosssection) Power Supply: Readers and door strikes via INTUS ACM80e LBus+supply DO+supply DI 1. floor 2. floor 21

200m Connection of 16 doors via second LBus. Connection of additional eight doors via LBus2 of the INTUS ACM80e Point-to-point connection of the reader 1 8 via eight standard LBus interfaces Multipoint connection of reader 9 16 via the optional LBus2 interface Control of 16 door strikes and the 16 door contacts by the 16 standard Digital-In/Digital-Out interfaces Line length: max. 200m (depending on cable cross-section) Power Supply: - reader 1 8 and door strikes via INTUS ACM80e - reader 9 16 and door strikes with separately local power supply LBus+supply DO+supply DI LBus2 9 10 11 12 13 14 1 2 3 4 15 5 6 7 8 PS PS 16 22

200m Connection of 16 doors via eight LBus interfaces. Connection of 16 doors via LBus of the INTUS ACM80e Combined Point-to-point and multipoint connection of the reader 1 16 via eight standard LBus interfaces Multipoint connection: max. 8 readers on 4 LBus interfaces Control of 16 door strikes and the 16 door contacts by the 16 standard Digital- In/Digital-Out interfaces Line length: max. 200m (depending on cable cross-section) Power Supply: - reader 1 8 and door strikes via INTUS ACM80e - reader 9 16 and door strikes with local power supply 1 LBus 1 DO DI LBus 4 LBus 3 LBus 2 9 2 3 8 16 23

Access control center in a 19 rack for 32 doors. Four INTUS ACM80e in a 19 rack with PC Panel PC Patchpanels Four INTUS ACM80e access control managers USV (Uninterruptible power supply) 8 8 LBus LBus Patch Panel ACM80e Patch Panel ACM80e Patch Panel ACM80e Patch Panel LBus LBus 8 8 ACM80e UPS 24

Access control center in a 19 rack for 64 doors. Four INTUS ACM80e in a 19 rack and use of LBus2 interfaces Using the second LBus interface up to 64 readers can be connected. LBus1: with point-to-point LBus2: with multipoint 1 8 8 LBus1 9 16 LBus2 33 40 8 LBus1 41 48 LBus2 PC Patch Panel ACM80e Patch Panel ACM80e Patch Panel ACM80e Patch Panel ACM80e LBus1 LBus2 LBus1 LBus2 8 8 17 24 25 32 49 56 57 64 UPS 25

100% galvanic isolation. Potential difference in industrial environment 100% secure with large potential difference between access control manager and remote building / gate Line length: more than 1 km; depending on used technology also several kilometers possible Digital In / Digital Out for gate control by local I/O module in secure area Power Supply: local power supply of I/O module and reader P I/O >1km fiber optic PS 26

Remote gate control. Large distance reader access card Line length INTUS ACM40 gate: 150m (depending on cable cross-section) Reader: TagMaster long-distance reader Distance reader card: 2-3 m typically Power Supply: local power supply of the readers LBus DO LBus DO P PS P PS 3m 27

LBus Video documentation of critical access points. Video documentation Automatic video recording of unauthorized access attempts Control of two doors with INTUS ACM40 Pick up of the pictures from the video server starting with INTUS COM version 3.2 INTUS ACM40 Videoserver Convision NVS basic DO DI 28

Video surveillance with network cameras. CONVISION NVS 19-8 with SeeTec server CONVISION CC-7634 network camera SeeTec client CONVISION CC-7433 network camera CONVISION CC-7333 network camera 29

Reader / subterminals Control level Supervision level Video surveillance with status information. SeeTec Client SeeTec Server ADAM-6050 module 12 input / 6 output ADAM-6060 module 6 input/ 6 output DI DO DI CONVISION CC-7433 30

Video surveillance with analog and network cameras. CONVISION NVS 19-8 with SeeTec Server CONVISION CC-7634 network camera AXIS P7216 16-channel video encoder AXIS M7011 1 channel video encoder coax or 2 wire SeeTec Client analog camera analog camera Integration of existing analog cameras CONVISION CC-7433 network camera CONVISION CC-7333 network camera 31

Recommended wiring of analog cameras. AXIS M7011 video encoder 2-wire transmitter receiver 2-wire transmitter sender A.C. power supply 24V voltage adapter (for 12V cameras) ~230V RS485 control lines (for controllable cameras) outdoor installation box Cat 5 or Cat 6 cable 4 pairs of wire 32

License Plate Recognition (LPR). ARH ParkIT License plate camera SeeTec Cayuga S100/Infinity (X) SeeTec License Plate Recognition DO 33

Vehicle Access Control based on LPR. SeeTec Cayuga S100/Infinity (X) SeeTec License Plate Recognition DI ARH ParkIT license plate camera DO Access reader INTUS 620 Access control software DO DI DO Access Control Manager INTUS ACM80e 34

Attachment. Color definitions of the connection R G B light brown 255 204 102 LBus / RS485 2 wire / V.24 4 wire light green 99 198 0 DI orange 255 102 0 DO blue-grey 132 151 176 Cat5 + power (INTUS PS) blue 0 102 255 DI or DO black 0 0 0 Coax / 2 wire (analog video) purple 204 0 204 35