icp 1000 Wireless GSM Based Remote Monitoring Unit for Transformer Rectifier Unit

Similar documents
Millenium 3. General Characteristics. General environment characteristics for CB, CD, XD, XR and XE product types

GS828. GPRS Data Logger

GS828-H. GPRS Data Logger

1.6. Counters, Panel Meters, Tachometers and Timers. Contents Description Fusion Integrated Machine Control Standards and Certifications...

IP68. Autarkic Data Loggers - MT-051 / MT-713 / MT-723

NX21 USER MANUAL. Telemetry Unit. Version 1.5

ALMEMO 202 ALMEMO professional measuring instrument, latest V7 generation with data logger function. ALMEMO V7 Measuring Instrument

Temperature / Humidity Controller for Stability Chamber

Testing Instruments Manufactured by

RCW-400A USER GUIDE. Version 1.1

1. Chapter 1 24/48/110/220VDC Power Supply System

IDM DATA ACQUISITION SYSTEM

Vaisala Veriteq VL 2000 Temperature Humidity Loggers

NI2400/NI816/NI4866 DATALOGGER NI2400/NI816/NI /16/24 CHANNEL ETHERNET DATA LOGGER with Embedded Web Server

Type VRLTC tap changer

MINER-S Station Controller. Substation Automation

Dupline. Data Logger. Types G , G Product Description. Ordering Key G Type Selection. Input/Output Specifications

Technical specifications

MINER-S Station Controller

International Journal of Scientific & Engineering Research, Volume 8, Issue 4, April ISSN

MW/MVAR Transducer Specifications

Andover ContinuumTM Infinet II

EM133 EM133 TOU SMART ENERGY METER. Main Features. Multifunctional 3-Phase Smart Meter. Billing/TOU Energy Meter

User Manual. GSM Fixed Wireless Phone (Model: GSM-938) Introduction

Mehta Tech, Inc. TRANSCAN IED For Multi-Function, Multi-Speed Recording

HYBRID PV INVERTERS HySpirit Series. 4kW-10kW. Hybrid Inverter with Battery Backup Smart Energy for Smart Home

FCU (FREE COOLING UNIT)

Communi-Cell Communicator Nokia Version

Andover ContinuumTM Infinet II

6220 Ethernet-Based Voltage Measurement Module

AUTOMATIC AND AUTONOMOUS REMOTE WATER LEVEL AND WATER QUALITY MONITORING STATION

Data logger systems from ROTRONIC

EM132 EM132. Main Features. Multi-functional 3-Phase Transducer. Energy Meter

WLS-TC Specifications

TU531, TU532 Terminal Unit

Elecsys ISM-4. Remote Monitoring System

Blackbox Controllers:

RIC PROGRAMMABLE INTELLIGENT CONTROLLER

UCM 94/1 3G/GPRS Modem for RTU32 Series

USB-500/600 Series Low-Cost Data Loggers and Accessories

Really Performs! Here is a Hand-Held Data Logger that Royalton Rd. Cleveland, OH USA Tel: (440) Fax: (440)

KDG27. GPS Tracker. Vehicle or Personal Position Tracking Vehicle Status and Speed Tracking. Auto Accident Report Global Position System (GPS)

GSM HOME SECURITY SYSTEM

Millenium II +: general characteristics

BACnet. b3810 Series Local Controllers

KTC. Preset Counter/ Timer. Programmable Type. Model Number Legend SALIENT FEATURES. Sensing. Digital Panel Meters

DS BAS 08/99 UNC 532

Smart Metering Monitoring and Control

Unitary Controller. Features. Description. Technical Specification Sheet Rev. 6, March, 2000

RT4F-110V/25A RECTIFIER

RTU32S RTU32S Series Small Compact Utility RTU

TECHNICAL SPECIFICATION OF GPRS based MODEM (Part 1)

General information Engineering with Programming package. Display with display

KAUGJUHTIMISSÜSTEEMID TELECONTROL SYSTEMS MODEM TELEM-GSM/GPRS 3G. User manual

RTU32S RTU32S Series Small Compact Utility RTU

General information Engineering with Programming package. Display with display. Supply voltage 24 V DC Yes. Input current

TF501, TF521 Terminal Bases

The IQ300 wall mount load cell indicator is a precision digital indicator for load cell and strain gauge applications.

BACnet. b3867 Terminal Controllers

The IQ240 panel mount load cell indicator is a precision digital indicator for load cell and strain gauge applications.

User s Guide. OM-EL-WiFi-TH. Shop online at omega.com. OM-EL-WiFi-T-PLUS. Data Logging Sensor

Part No. Description Product Life Cycle Phase *) unit, 24 VDC, spring terminals. unit, 24 VDC, spring terminals, XC version

Millenium 3 logic controllers

FEATURES DESCRIPTION SPECIFICATIONS

SOFREL LT/LT-US Data loggers Wastewater network solutions

Stand-Alone, Low-Cost Data Loggers and Accessories. USB-500/600 Series Comparison Chart

Jazz-J. Jazz. Features:

CM589 PROFINET Communication Module

Eltek TU GenII AQ110A comprehensive portable air quality monitor transmitter

User s Guide. OM-EL-WiFi-TH. Shop online at omega.com. OM-EL-WiFi-TP-PLUS. Probe Data Logging Sensor

CM579-PNIO PROFINET Communication Module

SEL-734B Data Sheet. Advanced Monitoring and Control System. Major Features and Benefits

MSR 2400R. Rugged Power System for Military and Heavy Duty Applications

Low Power Modbus GPRS Data Logger

Jazz-J. Jazz. Features:

SCADAPack 50. Wireless Remote Data Logger

VIBRATION MONITOR CX-RLY

Display. Supply voltage. Input current. Encoder supply. Output current. Power losses. Memory

DM650TM SENSOR / WALL MOUNTED TEMPERATURE DISPLAY

RT4F-48V/50A-WAC RECTIFIER

SM100. On-Line Switchgear Condition Monitoring

VOICE and/or DATA CELLULAR SYSTEM

Andover Continuum Infinet II i2865/866 VAV Controllers with Built-in Actuator

DMT340 Series Dewpoint and Temperature Transmitters for Very Dry Conditions

Specifications FEATURES

General information Engineering with Programming package. Display with display. Supply voltage 24 V DC Yes. Input current

24/48V Battery Bank Ah High Cycling Long Life

BVR Series Battery Voltage Recorders

5 to100 Amperes Linear Power Supply/Charger (120 Volt 60Hz) (220 Volt 50Hz)

x x 60 mm, 700 gm. Wall mounted enclosure, 1 Kg. Weatherproof, high impact GF ABS. Remote control and monitoring with debug features

ALL PSU Ltd ROTATION+ 6kVA - 10kVA PARALLEL ON LINE DOUBLE CONVERSION

IRM-5000P. insulation resistance meter. Vanguard Instruments Company, Inc.

xlogic xlogic is a latest generation Micro-plcs, compact and expandable CPU, replacing mini PLCs, multiple timers, relays and counters etc.

General information. Display. Supply voltage. Input current. Encoder supply. Output current

UWE-1707 SERIES CONTENTS OPERATION MANUAL ELECTRONIC WEIGHING INDICATOR 1. SPECIFICATIONS 2. INSTALLATION

REQUIREMENTS FOR WIRELESS, WEB-BASED MONITORING EQUIPMENT AND SERVICES FOR PUMP STATION APPLICAITONS

Display. Supply voltage. Input current. Encoder supply. Output current. Power losses. Memory

General information. Display. Supply voltage. Input current

MIRRIN. Multi-Channel Load Logger MODEL: LL400 User Manual 1 GETTING STARTED INTRODUCTION CONNECTIONS

Multi-instrument Communication, MIC-2 MKII DIN Quick Start Guide

Transcription:

icp 1000 Wireless GSM Based Remote Monitoring Unit for Transformer Rectifier Unit

The GSM based remote monitoring unit icp 1000, for Transformer Rectifier (TR) monitoring, is a highly accurate, compact, low power, low cost, micro controller based unit with built in GSM Modem which enables continuous Centralized Monitoring of TR parameters and at the same time notification for any alarm occurrence at central station as well on the configured cell numbers. This system enables easy & wireless centralized monitoring of all TR parameters like TR Voltage, TR Current, and Reference Potential and A.C Interference voltage (optional). The icp 1000 can be installed in the existing TR Unit and can directly accept TR parameters without the need of any transducers. The icp 1000 acquires all analog and digital parameters and transmits it to the central station at the programmed periodic interval. The icp 1000 notifies the user for the occurrence of any alarm signal and gives the data to the central station irrespective of the periodic interval. At the remote end, the Data could be received using a GSM interface module connected to the PC installed with the CP Software REMOTE DATA. Remote Data displays the data in the Analytical and graphical format and stores this data in the standard database, which is used for generating, reports for further analysis of the structure under protection. The data broadcast schedule is fully programmable from 1 broadcast per Minute to one broadcast per day.

Apart from sending the TR data to the remote stations, this unit also Logs data in its Non Volatile memory at the programmed logging interval, thus it also is a data logger. It can store about 7000 readings which can be downloaded on the Laptop computer using a RS232 port provided on the unit. The data stored in the internal memory can retain for 10 years without any external power. The detailed technical specifications of the unit are as under: Unit : icp 1000i / icp 1000iAC : Micro controller based intelligent TR Monitoring Unit with built in GSM Modem. SPECIFICATIONS Analog Inputs Computed Inputs : High accuracy, High Input Impedance > 10Mohms, 16 bit resolution, Differential Input with high common mode rejection ratio CMRR. CH 1: 0 100 VDC (for TR output DC Voltage) CH 2: 0 100 mv (for TR Output Current) CH 3: 4V to +4 V DC (for Reference potential) CH 4: 0 300VAC ( Through power supply inputs) : Apart from the acquiring the physical Analog signal, the icp 1000 also Computes for TR Run hours. It samples and logs the TR Input AC power every minute and computes for the TR Run hours. This Reading is used by Remote Data Software to generate the Up Time Report of the TR Unit. The icp 1000 also continuously scans and checks for Alarm conditions listed below on the basis of Reference potential Over Protection Under Protection Reference Fail The Set parameters for the above alarm conditions can be feed through the local keypad available on the front panel of the icp 1000. Status Inputs : Pre Programmed Alarms Indication for the below conditions DI 1: Over Protection. DI 2: Under Protection. DI 3: Reference Fail DI 4: Door Open Alarm GSM Interface Built In GSM Modem for broadcasting data to the Central Station at the programmed periodic interval. The Data are transmitted in the form of SMS.

Alarm Notification The icp 1000 will notify to all the configured cell numbers on their cell phone along with sending the notification to the central stations. Over Protection. Under Protection. Reference Fail Door Open Alarm AC Input Power Fail Centralised Monitoring The icp 1000 has built in GSM modem to communicate with the central station over the GSM network. The icp 1000, send the TR Data with exact time stamp to the central station at the programmed Periodic Interval. At the central end the PC is installed with the GSM module and centralized monitoring software Remote Data. The icp 1000 sends alarm information with exact time stamp to the central station and the configured cell numbers, irrespective of the Periodic Interval. Remote Data accepts the data received from the icp 1000, displays them in graphical and analytical formats and stores them in database to generate Reports and Graphs. It is also possible to send configuration details like Setting Data/Time, Setting/ changing Periodic Interval and Setting of cell phone numbers for getting Alarm notifications. Local Keypad & Display The icp 1000 consists of a 3 x 6 matrix membrane keypad and a 16 x 2 LCD with back lit for entering local settings and viewing TR parameters locally. Local settings such as Setting Data/ Time Setting Start Time for Periodic sending of data to the Central station. Setting Periodic Interval Scaling Entering cell numbers for alarm notifications. Setting ID of the icp 1000. Can be done using local keypad and LCD. The LCD will normally display TR Voltage TR Current Reference Potential TR Run Hours GSM Signal Strength GSM SIM registrations. The icp 1000 can also be remotely configured for some of the above parameters from the central station.

Programmable Periodic Interval Data Storage Time Stamping Protection Enclosure Ingress Protection Power Supply Battery Back UP Temperature Environment Test The Periodic interval can be programmable from 1 broadcast /Hour to broadcast / 24 hours. Data can be stored in the non volatile Memory. About 7000 readings can be stored without downloading. Local Data retention up to 10 years without any external power. The Logged Data in the icp 1000 can be downloaded on the Notebook computer using the serial communication port provided on the front panel of the icp 1000. The icp 1000 is supplied with Data downloading software LogData. LogData downloaded the Data and generates Reports and Graphs. The Unit has precise, accurate Real Time Clock (RTC) for exact time stamping of data. The Input channels have full protection against high voltage surges and continuous over voltages. The Enclosure is of ABS material and has an ingress protections level of IP54. The power supply of the icp 1000 can accept below both voltage ranges 120 VAC to 320 VAC For 4 Hours on AC Power failure. With Battery recharging and Deep discharge protection circuit. 20 degree C to 55 degree C and humidity of 95% (RH) 1> IEC 60068 2 2 Dry Heat (1994 05) 2> IEC 60068 2 78 Damp Heat Steady State (2001 08) 3> IEC 60068 2 30 Damp Heat Cyclic (1985 08) 4> IEC 60068 2 1 Cold Test (1994 05) Size Serial Port Cable Entry Compact size. Can be easily installed in the standard TR Units 200 x 120 x 100 (mm) The Unit has a RS232 port through which the logged data can be downloaded onto the laptop. Bottom