SERIES SIX PROGRAMMABLE CONTROLLERS

Similar documents
Catalog Number Identification with Elements Explained V V V V X 347 V Hz

IC693PWR331 High Capacity Power Supply, 24 VDC Input

ADDENDUM FOR 20, 27, & 28 OPTIONS

This Datasheet for the IC660BSM120. BUS Switching Module 115Vac/125Vdc.

This Datasheet for the IC670MDL /24VDC 0.5A Output Pos. Logic 16 Pt. Grouped.

Replacing the Power Supply

Chassis Power Supplies

MAINTENANCE MANUAL. EDACS REDUNDANT POWER SUPPLY SYSTEM 350A1441P1 and P2 POWER MODULE CHASSIS 350A1441P3, P4, AND P5 POWER MODULES TABLE OF CONTENTS

BOP QUICK START GUIDE 100W, 200W, 400W. KEPCO An ISO 9001 Company. BIPOLAR OPERATIONAL POWER SUPPLY WARNINGS I INTRODUCTION II SAFETY.

Discrete Input Modules IC697MDL653

Power Supply and Fan Module Installation

Power Supply (48Vdc, 2.5A)

TraceTek Leak Detection Master Module Installation Instructions TOOLS REQUIRED STORAGE

Installing Power Modules

Single Phase Systems-North American PC125/PC420 Series

Discrete Output Modules IC697MDL750 24/48 Volt DC, 0.5 Amp, 32 Point Output Module

OPERATING INSTRUCTION

V E1B Snap-in I/O Module

PS/IO Circuit Board Retrofit

Innovative Circuit Technology Ltd.

PACSystems* RX3i IC695PSA040

Infinity 1U 19 Converter Shelf Models: J L217 - Individual +24V Inputs Bulk -48V Output L218 - Individual -48V Input Bulk+24V Output

Junos WebApp Secure 5.0 Hardware Guide

This Datasheet for the IC697BEM721. I/O Link Interface Module for the Series

PV Rapid Shutdown device

Four opto-isolated signal channels: SD, RD, RTS, and CTS. Electrical compatibility with RS-485. A 5V DC/DC converter for power isolation

Installation Instructions

IST ULTRASTAB Power Supply for IT/ITN ULTRASTAB transducers

ICS Regent. Relay Output Modules. Low Power and High Power (T3446L and T3446H) PD-6017

Series AME5-CJZ 5 Watt AC-DC / DC-DC Converter

BOP QUICK START GUIDE 100W, 200W, 400W. KEPCO An ISO 9001 Company. BIPOLAR OPERATIONAL POWER SUPPLY I INTRODUCTION

Series AME25-JZ 25 Watt AC-DC / DC-DC Converter

SECURITY DOOR CONTROLS 801 Avenida Acaso, Camarillo, Ca (805) Fax: (805)

IC693 PLC IC693ACC350, IC693ACC340/341

Instruction Manual. Multilin TM 8 Series Retrofit Kit * A1* GE Grid Solutions LISTED

IST ULTRASTAB Power Supply for high precision transducers

User s Manual. ACS550-PD 3R Irrigation Packaged Drive Supplement to ACS550-U1 User s Manual

PS5R Series Switching Power Supplies. The PS5R offers a sleek, compact, ergonomic design, worldwide approvals, and broad range of output capacities.

S-14 S-14. Compact Digital Multimeter. Compact Digital Multimeter

V E2B Snap-in I/O Module

Intelligent Channel Bank Shelf

This Datasheet is for the IC693PWR332. High Capacity Power Supply, 12 VDC Input.

Discrete Output Modules IC697MDL740

BIPOLAR OPERATIONAL POWER SUPPLY

Installation Job Aid for VSP 4850GTS

Energy Management System. Operation and Installation Manual

PACSystems* RX3i IC695PSA140

Discrete Output Modules IC697MDL750

SLI 15 INVERTER SERIES, 1500 W

Battery Chmgers. Farnell POWER

Installation Job Aid for VSP 4450GTX-HT- PWR+

File E Project 90ME March 12, 1991 REPORT

Mini Digital Multimeter

MAJOR VA Power Inverter

Installation Note for the Cisco ME 3800X and ME 3600X Switch Power Supply and Fan Modules

PLATINUM SERIES R PART NUMBER SELECTION. High performance SPDT up to 40 GHz. Our Most Important Connection is with You. SMA - SMA 2.

HP UPS R/T3000 G2. Overview. Precautions. Kit contents. Installation Instructions

JUPITER-MM. DC/DC Power Supply PC/104 Module. User Manual V1.3

V2 LED SOFTLIGHT USER GUIDE

OPERATING MANUAL LOW-VOLTAGE DISCONNECT PANELS LVD400 & LVD600 SERIES

DM-918 OPERATIONS MANUAL AUTORANGING MULTIMETER

407B 1/16 DIN Multi-Mode Timer

User's Guide. MiniTec TM Series Model MN25 MultiMeter

MODEL SW6000 & SM6100 CENELEC INSTRUCTIONS

This Datasheet is for the IC693CBL300. I/O Bus Expansion Cables.

HID. GE Consumer & Industrial Multilin. High Impedance Differential Module Instruction manual GEK Copyright 2005 GE Multilin

INSTRUCTION MANUAL RA 55 RACK ADAPTER RACK ADAPTER FOR MST SERIES POWER MODULES

Liebert AccuVar (ACV Series) Surge Protective Device (SPD) (With Noise Filtering) GUIDE SPECIFICATIONS for a Parallel Surge Suppression System

MODEL 8000MP LEVEL SENSOR

H3C S12500 Routing Switch Series

Surge Protective Devices. STV25K Series. Instruction Manual

ISO 9001 CERTIFIED. 607 NW 27th Ave Ocala, FL Phone: (352) or Fax: (352) SUITABLE FOR EXTERNAL DISTRIBUTION

PowerFlex 40 Sample Specification

Installing and Removing SDRAM and DRAM

ASCO 920 Remote Control (RC) Switches

Quantum III. Compact DC Drive Package. Slitter DC Drive Package. Quantum III

Installation RA5112-C-16A-C20. Basic Rack Power Distribution Unit

Chapter 5 Review. Power Supplies

Installation and Wiring

HCS-3600 / 3602 / 3604 Laboratory Grade & High RFI Immunity Switching Mode Power Supply with Rotary Encoder Control

Allen-Bradley PLCs. 100 Programmable Controller Processor Unit -Catalog Nos LPI01, -LP102, -LP103, -LP104 SLC TM. The Unit

This Datasheet for the IC697CHS790. Rack, 9 Slots, Rear Mount.

Expansion Unit Catalog Nos , - 152, - 153, - 154, - 156, -E157

EXPRESS SETUP. PanelMate 1700 Series PanelMate Power Pro. Cutler-Hammer

Model HM-535 Power Supply Installation and Service Instructions

Software... pg3 File Maintenance Training

Sorensen SG Series kw V A. Programmable Precision High Power DC Power Supply

Mini Digital Multimeter

1.2 Intel Server Chassis SC5400BASE Summary

PGR-4700 MANUAL SENSITIVE GROUND-FAULT RELAY

INSTALLATION INSTRUCTIONS Model 930 EntryCheck

Series AMEL20-AZ 20 Watt AC-DC / DC-DC Converter

.2 Section General Commissioning (Cx) Requirements. .3 Section Common Work Requirements - Electrical

Typical Input current at 1.15A 0.65A 60 Watt 24VDC / 2.5A. 1.84A 1.0A 120 Watt 24VDC / 5.0A

AutoRanging Digital MultiMeter

Model 500 Series Laser Diode Driver User's Manual

Installing the Cisco NCS 2006 Door and Other Modules

PowerFlex DC Drive Frame B Pulse Transformer Circuit Board

EATON Transformer Module

SLI 15 Inverter Series Data Sheet 1500 Watt, 1U Compact Inverters

Transcription:

SERIES SIX PROGRAMMABLE CONTROLLERS 125 V DC INPUT CPU POWER SUPPLY MODULE GFK-0065 Source Voltage 100 to 150 V dc Output Voltage +5, +12, -12 V dc GENERAL DESCRIPTION The 125 V dc Input CPU Power Supply Module, used in the Central Processor Unit (CPU), is available to be used with a power source from 100 to 150 V dc. The features and benefits of this module are summarized in Table 1. The 125 V dc Input CPU Power Supply Module provides regulated +12, -12 and +5 dc voltages to the rack backplane. The input (or source voltage) is applied to terminals on the front panel, then routed through a switch and fuse to a switching power supply. For a given load the input power drain remains essentially constant The power supply is protected against polarity reversal of the dc Input. The module provides electromechanical relay contacts for connection to user indicators, or any device to be activated during an alarm condition. The module also provides a voltage regulator for an opt ional, auxiliary battery that provides battery back-up of Complementary Metal-Oxide Semiconductor (CMOS) memory contained in the processor rack. A Keyswitch mounted on the front panel is used to select either the RUN or the STOP mode for the processor; a second Keyswitch allows the user to protect the contents of the processor memories by placing them in a READ ONLY mode. The same key operates both Keyswitches. Refer to Table 2 for the CPU Power Supply module specifications. The 125 V dc input CPU Power Supply Module may be used in place of a 115/230 V ac or a 24 V dc Input CPU Power Supply Module in an existing rack if 125 V dc input is desired. TABLE 1. FEATURES AND BENEFITS FEATURES Uses dc input power source. Can be used in any CPU rack. BENEFITS Extends power source compatibility to 125 V dc systems. Reduced spare-parts inventory. Provides electromechanical-relay con- Activates user-supplied power inditacts for alarm indications. cators. Contains voltage regulator for auxiliary battery. External battery back-up of CMOS memory.

GFK-0065 125 V dc Input CPU/DPU Power Supply Module 2 Table 2. SPEClFlCATlONS Input: 100 to 50 V dc, 2 A max. Altitude: Up to 10,000 feet (3,000 meters) above output: Total power sea level. 1. +5 V dc, 16.5 A max. 2. +I2 V dc, 1.5 A max. from all outputs Auxiliary Battery Input: 3. -12 V dc, 1.0 A max. must be 8-28 V dc 4. +I2 V dc, 2.0 A max. 1 less than 90 watts. Dimensions: 12.46 x 9.00 x 2.75 Output number 4 rated at 12.0 V dc (inches) 317 x 229 nominal when output supply currents are: x 70 (mm) (I) +5 V dc @ 8.0 A (2) +12 V dc @ 1.0 A Operating Temperature: (3) -12 V dc @ 0.5 A 0 C to 60 C (4) +12 V dc @ 1.0 A (outside of the rack) Allowable Power Interruptions: 4ms minimum at 100 V dc line. Storage Temperature: -20 C to +8O C Noise lmmunity: Meets requirements of Humidity: 5% to 95% NEMA KS 2-230 and (non-condensing) ANSI C37.90A. INSTALLATION These steps define the procedures to be followed when a power supply is to be replaced on a Series Six or Six Plus CPU rack. The tools needed are a regular screwdriver, Phillips screwdriver, and a 5/16 wrench or nut driver. 1. Stop the system by switching the top key on the CPU to STOP. 2. Switch off all units in the system, including the user s power supplies. 3. Remove all power from the system, preferably at the source (i.e. throw the main circuit breaker for the system). 4. Locate the power supply to be changed. The power supply is in the far right side of the CPU rack. 5. Remove the plastic cover on the lower portion of the power supply to be replaced and using a volt-meter, make sure there is no dc power present. 6. Take note of the location and color of the dc wires and then remove them. Also, remove Auxiliary battery and/or Alarm connection(s) noting location, color, and polarity for correct replacement.

GFK-0065 125 V dc Input CPU/DPU Power Supply Module 4 lnstallatlon (Continued) 7. At the top and bottom of the power supply, there are l/4-turn thumbscrews. To loosen, turn the thumbscrews approximately l/4 turn counterclockwise. 11. Slide the power supply into the rack, being careful not to damage the wires. When the power supply is all the way in, turn the thumbscrews clockwise until they lock in. 8. 9. Grasp the thumbscrews and gently pull outward. Be careful not to damage the internal wiring while pul I ing the supply out. Locate the wires that extend from the back of the rack to the terminal on the power supply. These wires should be labeled or stamped with their location; the circuit boards have wire locations stamped on them. Remove these wires. There is also a plastic wire clamp holding these wires in place. Detach this from the frame if there is not a similar item on the replacement power supply, or cut the clamp if there is one on the new supply. 12. 13. Remove the plastic cover on the lower portion of the power supply and attach the DC wires, as well as the battery and alarm wires, as they were on the original supply (Refer to Step 6 and Figure 3). Replace the plastic cover. Verify that the DC input lines are of the correct polarity before applying power. An inadvertant reversal of input polarity will cause the supply to draw excessive currents and may blow the internal fuse (2A slo-blow) which must then be replaced before proper operation can be resumed. Remove the 18-pin (P1) molex connector that is on the narrow board in the front part of the power supply. The power supply should now be completely detached from the rack. 14. Restore system power. Turn on the CPU unit. Check to see if the POWER light is on. If it is, turn on the rest of the system and resume normal operation. 10. Take the replacement power supply and attach the wires as shown in Figure 2. Be sure to connect the 18-pin molex connector (P1) to the power supply. Attach the wire clamp on the upper stud of the power supply frame, or if there is a clamp already there, wrap the wires in it. 15. If the POWER light does not come on, the power supply may be bad, source voltage may not be turned on, or there may be other problems within the rack. Please call your local authorized GE Fanuc Automation Distributor or Sales off ice for assistance.

GFK-0065 125 V dc Input CPU/DPU Power Supply Module 5 WIRES FROM THE BACK PLANE WILL BE MARKED TPK.A.41589,STB-9 OR 5V 9) (PSTB-7 OR OV 8) (PSTB-6 OR + 12Vi6) (PSTB-5 OR - 12V/5) (PSTB-4 OR + 12V 4) + TO BACKPLANE MOLEX CONNECTOR - Pl FIGURE 2. POWER SUPPLY EXTERNAL WIRING DIAGRAM If a memory auxiliary battery is used, the circuit connecting it to this module should be isolated from the rest of the system. If this CAUTION is not observed, the battery could be shortcircuited. The alarm contacts consist of two sets of normally-opened and normal iy-closed contacts. The terminals marked 1 NO and 1 NC are associated with Alarm Type No. 1; the terminals marked 2 NO and 2 NC with Alarm type No. 2. (Refer to Series Six Plus User s Manual, GEK-96602, for further information on Alarm Nos. 1 and 2.) The user devices connected to each set of Alarm terminals on this module should present a resistive load drawing no more than one amp of current at no greater than 115 V ac/28 V dc. Failure to observe this CAUTION may result in damage to the circuit board. NOTE During normal operation the alarm relays are energized. During an alarm condition the contacts marked IN0 and 2NO, open, and those marked 1NC and 2NC, close.

GFK-0065 125 V dc Input CPWDPU Power Supply Module 6 Ref. PC-S6-84-0246 AUXILIARY BATTERY ALARM RELAY CONTACTS (ISOLATED) 2N0 0 2NC - tl 0 PCS NEG GROUND (G) CONTACT RATING FOR DC INPUT TERMINALS IS 125V DC, 300 MA RESISTIVE DC INPUT looto150vdc FIGURE 3. FRONT-PANEL TERMINAL BLOCK ORDERING INFORMATION Module 125 V dc Input CPU Power Supply Module Part Number I C600PM546 The UL symbol on the nameplate means the product is listed by Underwriters Laboratories Inc. (UL Standard No. 508, Industrial Control Equipment, subsection Electronic Power Conversion Equipment.) For further information, contact your local GE Fanuc Automation Sales office. GE FANUC AUTOMATION NORTH AMERICA, INC., CHARLOTTESVILLE, VIRGINIA MARCH, 1987