Type VRLTC tap changer

Similar documents
MINER-S Station Controller

Scout-S Station Controller

Relion 611 series. 611 series Type Test Certificate

This annex is valid from: to Replaces annex dated: Location(s) where activities are performed under accreditation

MINER-S Station Controller. Substation Automation

TU531, TU532 Terminal Unit

Autodaptive Capacitor Control M 2501B

RE17LAMW on-delay timing relay - 1 s..100 h V AC/ DC - solid state output

TF501, TF521 Terminal Bases

Type MVTT 14 and MVTT 15: Static Digital Time delay relays

INSTRUCTION MANUAL TRIP CIRCUIT SUPERVISION RELAY GKAD1

Part No. Description Product Life Cycle Phase *) unit, 24 VDC, spring terminals. unit, 24 VDC, spring terminals, XC version

QUALITROL QTMS Transformer Monitoring System

Technical specifications

RE17LCBM off-delay timing relay - control - 1 s..100 h V - solid state output

RE17LAMW on-delay timing relay - 1 s..100 h V AC/DC - solid state output

Arc protection relay. Features Three-phase overcurrent function. Application

SPA-ZC 302. Profibus-DPV1/SPA Gateway. Product Guide. spa-zc302_rightco300

Providing the missing piece in your Condition Based Monitoring platform

RE22R1QMQ star-delta timing relay - 230VAC/440VAC - 1 C/O

AO523 Analog Input Module

Communication Gateway COM 610. Product Guide

CD522 Encoder, Counter and PWM Module

CompactBlock Guard I/O EtherNet/IP Safety Modules

RuggedMC RMC RUGGEDCOM ISO 9001 REGISTERED. Features and Benefits. Ethernet Media Converter (Copper to Fiber) Universal Power Supply Options

Switching Control Sentinel (SCS) TM For all ABB independent pole operated circuit breakers

EM132 EM132. Main Features. Multi-functional 3-Phase Transducer. Energy Meter

INGEPAC DA-CU. Control Unit. Data Sheet ZY8932IMA01E 31/03/2016

Output Voltage* (nom.)(adjustable)

CM592 PROFIBUS Communication Module

TM3AI4 module TM3-4 analog inputs

Stratix 5700 Ethernet Managed Switches

For Transmission, Distribution and Machinery protection.

RE Product data sheet Characteristics. universal plug-in timing relay - flashing s..60 mn V AC - 2 OC. Main.

RE22R2AMR On-delay Timing Relay s 300h V AC/DC - 2C/O

RE22R2CMR Off-delay Timing Relay s 300h V AC/DC - 2C/O

iswitch imotor Compact QR

RE22R2KMR Off-delay Timing Relay s 10min V AC/DC - 2C/O

RE22R2QGMR Star-Delta Timing Relay s 300h V AC/DC - 2C/O

Thermistor motor protection relays CM-MSS.12 and CM-MSS.13

TM3TI8T module TM3-8 inputs temperature

RE22R1QMQ star-delta timing relay - 230VAC/440VAC - 1 C/ O

RT12-240V/2.4kW Rectifier Specification

Constant Voltage Mode

RE Product data sheet Characteristics. time delay relay for star-delta starter ms - 230/380 V AC - 1 contact. Main.

CM589 PROFINET Communication Module

CM579-PNIO PROFINET Communication Module

TM3TI4 module TM3-4 inputs temperature

RT4B-110V/12A RECTIFIER

RT4F-110V/25A RECTIFIER

RE11RAMU on-delay timing relay - 1 s..100 h V AC - 1 OC

AX521 Analog Input/Output Module

MULTILINK ML2400 Guideform Specification

Relion 605 series. Self-powered feeder protection REJ603 Product Guide

Thermistor motor protection relays CM-MSS.22 and CM-MSS.23

RE48ATM12MW on-delay timing relay s..300 h V AC - 2 OC

TM3SAC5RG SAFETY MODULE FOR PLC TM2xx, 1 FUNCTION, CAT3, SPRING TERMINALS

GEN series G070A. Data sheet. Torque/RPM adapter. Special features

FEATURES DESCRIPTION FEATURES

FL MC 2000E (SM40) LC

RuggedMC RMC40 RUGGEDCOM ISO 9001 REGISTERED. Features and Benefits. 4-Port Ethernet Media and Speed Converter

CM597 Ethernet Communication Module

PROTECTION RELAYS THE ULTRA LINE NUMERICAL MULTIFUNCTION INTELLIGENT DEVICE FOR PROTECTION, SUPERVISION, METERING AND CONTROL

Arc protection relay. Features Three-phase overcurrent function. Application

Thermistor motor protection relays CM-MSS.12 and CM-MSS.13

Universal Power Supplies

CI504 PROFINET Communication Interface Module

Thermistor motor protection relays CM-MSS.22 and CM-MSS.23

Safety Standards. Model Number:

Output Voltage* (nom.)(adjustable)

ControlNet-to-DeviceNet Linking Device

TM3TM3 module TM3-2 temperature inputs and 1 analog output

PDD-300 pulsed diode driver

CI542 PROFIBUS Communication Interface Module

RT4F-48V/50A-WAC RECTIFIER

Published by and copyright 2015 Siemens AG Energy Management Freyeslebenstr Erlangen, Germany

RE22R2AMR On-delay Timing Relay s 300h V AC/DC - 2C/O

TM3DI16 module TM3-16 inputs

Model Number Structure

RM22TG. Product data sheet Characteristics. three-phase control relay Vac, 2 C/O. Main. Complementary. Network number of phases

Single-phase ( V) voltage monitoring: Undervoltage Overvoltage Window mode (overvoltage + undervoltage) Voltage fault memory selectable

RT4F-120V/20A-WAC RECTIFIER

RTU500 series Data Sheet Power Supply CP-E 24/2.5

HMISBC Rear Module controller panel - Dig 8 inputs/8 outputs +Ana 4 In/2 Out

G3PC. Model Number Structure. Solid State Relays with Failure Detection Function. Model Number Legend

CM589 PROFINET Communication Module

Electronic timer CT-ERD.12

ArmorPoint I/O Field Potential Distributor, Series A

DC541 Digital Input/Output Module

EH-RIO IP67 Profibus-DP I/O modules

EM133 EM133 TOU SMART ENERGY METER. Main Features. Multifunctional 3-Phase Smart Meter. Billing/TOU Energy Meter

Test and Measurements Automated Systems Component Device Testing Semiconductor Processing & Burn-in Aerospace & Satellite Testing

RE22R2QTMR Star-Delta Timing Relay s 300h V AC/DC - 2C/O

Thermistor motor protection relay CM-MSS.11

TM3SAF. Main. Device short name

Electronic timer CT-ERS.12 ON-delayed with 1 c/o contact Data sheet

CI541 PROFIBUS Communication Interface Module

DC532-XC, digital input/output module,

RE48ATM12MW on-delay timing relay s..300 h V AC - 2 OC

Features. Applications and Benefits TRC ELECTRONICS, INC

Transcription:

Report No. 1ZUA938502-AGC 2, Rev 0 Date: 6 November 2012 Type VRLTC tap changer Ruggedized electronics systems specification & type test data Product Style No Rating By Type VRLTC, on-tank, vacuum reactance load tap changer All versions 25 kv, 1500 A Bill Teising and Jon Brasher 1 Introduction The type VRLTC tap changer contains sub systems which monitor and control the entire tap changing functions. The heart of these controlling sub systems is Tap Logic Monitoring System (TLMS). The TLMS is a solid state device which monitors and collects data from the various sensors within the tap changer. The TLMS detects any abnormality, it is programed to issue an alarm or an alert depending on the severity of the abnormality. The TLMS is also on constant alert monitoring and selfchecking for any sign of a problem. We have designed the TLMS to perform correctly in the harsh electromagnetic environment of an electric substation. The circuit boards are hardened against electromagnetic radiation by design and by selection of individual components. We put the TLMS through a series of severe environmental and electromagnetic radiation tests according to ANSI and IEC standards to ensure that the design would operate properly in its intended environment. All results can be found on test report R-14101. 2 Type test summary ABB applied both ANSI and IEC standards to proscribe the testing necessary to demonstrate immunity from radiated electromagnetic disturbances. The following standards measure the ability of the servo motor drive to withstand electromagnetic radiation.

2.1 EMC immunity test IEEE standard ANSI C37.90.1:2002, fast transient and 1MHz oscillatory wave ANSI C37.90.0, dielectric withstand and voltage impulse IEC standard IEC 61000-4-2, Electrostatic Discharge IEC 61000-4-3, Rad. Immunity, 80 MHz - 1 GHz, 1.4 GHz - 2.7 GHz IEC 61000-4-4, Electrical Fast Transient / Burst, Power Ports IEC 61000-4-4, Electrical Fast Transient / Burst, I/O Ports IEC 61000-4-5, Surge, Power Ports IEC 61000-4-5, Surge, Power, IO Ports IEC 61000-4-6, Conducted Immunity, Power Ports, 0.15 to 80 MHz IEC 61000-4-11, Voltage Dips and Interrupts IEC 61000-4-12, Damped Oscillatory Wave, Power Leads IEC 61000-4-12, Damped Oscillatory Wave, I/O Ports 2.1.1 ABB report number R-14101 2.1.2 Description Test the ability of the motor-drive system (motor, digital drive, TLMS, etc.) to withstand electromagnetic radiation according to the standards cited above. 2.1.3 Results Immunity Radiated RF fields Conducted RF voltage Fast transient / burst Electrostatic discharge Surge pulse Power frequency magnetic field Power voltage variation Damped oscillatory wave Enclosure Process Mains ports Earth ports Results / port I/O ports Criteria 15 V / m Passed / A 10 V 10 V 10 V Passed / A 4 kv 4 kv 4 kv Passed / A 8 kv contact, Passed / A 15 kv air 4 kv 4 kv (CM) Passed / A (CM) 2 kv (NM) 1000 A / m Passed / A ±10%, 15 s Passed / A 2.5 kv 2.5 kv Passed / A

2.2 Type test, EMC emission IEEE standard C37.90 IEC standard CISPR 11, G 1, Class A, conducted emissions, 150 khz to 30 MHz CISPR 11, G 1, Class A, radiated emissions, 30 MHz to 1 GHz 2.2.1 ABB report number R-14101 2.2.2 Description Measure the amount of electro-magnetic radiation emitted by the motor-drive system (motor, digital drive, TLMS, etc.). 2.2.3 Results Emission Port Class Limits Results Radiated emissions Enclosure A Limits of EN 55011, Measure distance according to EN 50081-2 Passed Conducted emissions AC Mains A Limits of EN 55011 Passed 2.3 Type test, environmental Description Standard Test Requirement Results Dry heat IEC 60068-2-2 Test Bd during operation Test Bd during storage + 60 C for 96 h +85 C for 24 h Passed Cold IEC 60068-2-1 Test Ad during operation Test Ab during storage -30 C for 96 h -50 C for 24 h Passed Change of temperature IEC 60068-2-14 Test Nb -30 C to +60 C 5 cycles x 3h Passed Damp heat cycle IEC 60068-2-30 Test Db +25 C to +55 C 6 cycles x 24 h Passed Damp head steady state IEC 60068-2-78 Test Cab +40 C, 93% RH for 240 h Passed 2.4 Type test, shock/vibration Description Standard Requirement Results IEC 60069-2-6 Vibration IEC 60255-21-1 Frequency: 10-150 Hz, 2 g Passed Shock IEC 60255-21-2 30 g, 11 ms Passed Bump IEC 60255-21-2 10 g, 16 ms Passed Seismic IEC 60068-2-6 IEC 60255-21-3 1-35 Hz, 7.5 mm / 2 g Passed

3 Sub component ruggedization In order to ensure the immunities noted previously, the entire system must be designed to be immune from any radiated energy. This includes using circuit designs which contain error cancelling details and which are inherently stable. The sub components which make up these solid state circuits must also be ruggedized to withstand the radiated energy. The following table describes the major components (see figure 1) found inside the servo motor drive. 3.1 Component selection and design for electromagnetic ruggedness All components on TLMS motherboard are rated -40 F to +185 F (-40 C to +85 C) Operating temperature range is -40 F to +185 F (-40 C to +85 C) Humidity is 95% non-condensing Conformal coating on: TLMS motherboard VFD display 3.1.2 TLMS Motherboard The TLMS motherboard incorporates the following design principles for reliable operation in harsh EMC environments. 32-bit microprocessor with proprietary firmware Capacitive decoupling (minimize loop currents) Optimized PWB zoning layout (isolate digital circuits from analog circuits). Note in figure at right the light colored areas these are isolation zones. Impedance matching of traces on PWB MOV protection: 275 Vac / 350 Vdc / 43 J PWB level isolation between all major subsystems on TLMS motherboard o microprocessor o optoisolated digital inputs o relay outputs o 4-20 ma tap position outputs o CT inputs o CAN master port o Servo drive I/O interface o Differential signaling on CT inputs o Relay output contact ratings 6 A / 250 Vac

3.1.3 Multi-turn absolute position encoder = Heidenhain EnDat 2.2 (serial data interface) Benefits of EnDat 2.2 encoder interface: 100% serial data transmission Automatic self-configuration: All information required by the TLMS is stored in the encoder. High system security: Encoder generates alarms and messages for monitoring and diagnosis. High transmission reliability: Cyclic redundancy checks (CRC) of transmitted data between TLMS and Heidenhain en-coder. 3.1.4 Operational burn-in testing performed on every TLMS unit 60 C ambient temperature for 20 hours 3.1.5 Multi-turn absolute encoder specifications Operating temperature range: -40 C to +100 C (-40 F to +212 F) Protection: IP 67 at housing, IP 64 at shaft inlet Resolution: 33,554,432 (25 bits) = 0.0000107 degrees / 0.038 arc seconds Accuracy = ± 0.0055 degrees / ± 20 arc seconds Passed all EMC type tests