Polymer Coated Fiber Cable (PCF)

Similar documents
Panduit Certified Installer. Fiber Certification Review

Plug & Play Universal Harness, SMF-28 Ultra Single-mode (OS2)

Advances in Robust, Easy to Install Fiber Cabling Systems to Support EtherNet/IP

CORNING OPTICAL COMMUNICATIONS GENERIC SPECIFICATION FOR SIMPLEX OPTICAL FIBER (MULTIMODE) NO-EPOXY, NO-POLISH CONNECTORS

Fiber Optical Cabling Infrastructure Offer

Pretium EDGE Solutions Trunk Cable, OM3, Low-Loss, MTP to MTP, 24 fibres

Data Center & Cloud Computing Infrastruture Solutions DATASHEET. MTP/MPO-LC Breakout Cable Aseemblies High Density Cabling System

Optical Fiber Assemblies

Pretium EDGE Solutions Trunk Cable, OM4, Low-Loss, MTP to MTP, 24 fibres

Application Note AN114

Indoor Cable Application Note

SC/APC Connector. CATV Active device Telecommunication. Metro Local Area Data processing

EDGE Solutions Trunk Cable, OM4, Low- Loss, MTP to MTP, 12 fibres

Volition. Multimode VF-45 Socket and Patch Cords. 3Innovation

Pre-polished Connector Insertion Loss and Termination Yield. Achieving High Termination Yields And Low Insertion Loss Values

Basic Fiber Optic Concepts

Volition. Multimode VF-45 Socket and Patch Cords. 3Innovation

Data sheet PM PCC OpDAT patch cord LC-D/LC-D OM3 aqua, 20.0 m

OPTICAL FIBER INTRODUCTION

OPTICAL CABLE & CABLE ASSEMBLY

Pretium EDGE Solutions Harness, 12 fibres,

EDGE Solutions Hybrid Trunk, OM4, Low- Loss, MTP to LC Duplex Uniboot, 24 fibres

Volition. VF-45 Singlemode Socket and Patch Cords. 3Innovation IT'S AS EASY AS PLUGGING IN AN RJ-45.

Fiber Optical Cabling Infrastructure Offer

VOLITION INTERCONNECT VF-45 STYLE

EDGE8 MTP Trunk Cable

Structured (premises) wiring systems: building backbone (riser) and/or horizontal cabling.

SUMITOMO SPECIFICATION. FutureFLEX. Multimode 62.5 µm Core Optical Fiber (OM1) Gigabit Grade

Pretium EDGE Solutions Trunk Cable, 50 µm multimode (OM3)

LC Connector. A High Density Fiber Optic Network Solution. Paul Kolesar Lucent Technologies, Bell Laboratories

Alternative Energy Solutions

Opt-X Enterprise Fiber Trunk Cables

HIGH DENSITY DATA CENTER CABLING GUIDE. Optics DACs Cables Cable Management Fiber TAPs Media Converters

LEAD Fiber Optics PRODUCT CATALOGUE

Our Most Important Connection is with You. OSIS SECTION 7. OSIS Series

Plug & Play Universal Low-Loss Systems A LANscape Pretium Solutions Product

SPEC SHEET. Multimode Patch Cords and Pigtails. Cable types. Description. Features. Fiber types

MTP Outdoor Cabling System

A COMPARISON OF PRE-POLISHED CONNECTORS VS. FUSION-SPLICED PIGTAILS AS FIELD TERMINABLE SOLUTIONS

Pre-terminated Multi Fibre Cable Assemblies

Pretium EDGE HD Solutions A LANscape Pretium Solutions Product

Data Center & Cloud Computing Infrastructure Solutions DATASHEET. MTP/MPO-LC/SC Cassette High-density Pre-terminated Modular Cassette System

Plug & Play Universal Systems

CELL SITE INFRASTRUCTURE SOLUTIONS. Creative Solutions for the Mobile Evolution

1 of 5 12/31/2008 8:41 AM

Fiber Optical Cabling Infrastructure Offer

Disadvantages of Fiber-Optic Cabling

3 No Polish LC 50um Multimode Connector Environmental and Mechanical Test Report

13-SDMS-01 REV SDMS-01, REV.00 SEC DISTRIBUTION MATERIALS SPECIFICATION DATE: G

Pretium EDGE FX Solutions

Leaders in the Advancement of Multimode Fiber. Fiber Future and Beyond

FMT4S. High Density Connectivity Solution

INDUSTRIAL TRAY CABLE PRODUCTS

Introduction to optical fibers and their applications

QuickSpecs. HPE OfficeConnect 1420 Switch Series. Overview. Models. Key features

FiberSolutions. Fiber Optic Cable & Assembly Solutions

MTP Multi Lite Trunk Assemblies

UniCam High-Performance Connectors, Multimode and Single-Mode

Datasheet. SFP/SFP+ Modules and Cabling. Single-Mode, Multi-Mode, or Copper Compatibility. 1 Gbps Using SFP or 10G Speeds Using SFP+

March 2018 OM1 MULTIMODE DUPLEX FIBRE OPTIC CABLE 500M OM4 MULTIMODE DUPLEX FIBRE OPTIC CABLE 500M OS2 SINGLEMODE DUPLEX FIBRE OPTIC CABLE 500M

AMP ACT 1 INSTALLING PREMISES CABLING SYSTEM. Welcome!!! Instructor : Nicholas Yeo

Fiber Optic and CAT 5-6 Installer Premise Cabling

CONNECTOR SOLUTIONS. FASTConnect FUSEConnect Field Master

Pre-Terminated. FiberExpress

Factory assembled FO cabling system with LC-Duplex adapter-interfaces in PURE quality, GHMT channel certified

Data Center & Cloud Computing Infrastruture Solutions DATASHEET. Standard Fiber Patch Cable. Make high-speed Ethernet network equipment connections

OLS Series Light Sources, OPM Series Optical Power Meters, and Related Test Kits User s Guide

Rear Pivot Latch LC Connector. A Robust SFF Fiber Optic Connector for High-Density Network Applications

QuickSpecs. Models. Features and Benefits Connectivity. HP V2124 Switch. HP V2124 Switch. Overview

A wide range of connectors are available to fit very specific needs.

Fiber Optic Technician - Outside Plant (FOT-OSP) Course Description. Certification(s) Students Will Learn. Splicing Overview & Testing Outside Plant

Pretium EDGE Tap Module Installation and Testing

Plug & Play Universal Systems

LEAVE THE TECH TO US

EDGE Solutions Trunk Cable, SMF-28 Ultra OS2, MTP to MTP, 12 fibres

A Closer Look at Plug and Play MPO/MTP Assemblies

EC Series LC Connectors

Cable Certification. General Testing Criteria (Applies to all cable certification testing) Attachment F Cable Certification

Sumitomo Fiber Specification SE-7** Non-Zero Dispersion Shifted Single-Mode Fiber. PureMetro SM Optical Fiber, TIA Type Ivd, ITU-T G.

Clearview Cassette. Clearview Blue

Ultra Low Loss (ULL) LazrSPEED 550 OM4 LC to LC, Fiber Patch Cord, 1.6 mm Duplex, LSZH

How to Decide on Optical Fibre Termination Options. Thomas Ko, RCDD Product Manager Tyco Electronics / AMP NetConnect

DATA CENTER SOLUTIONS TM. Fiber Flex

PreCONNECT PURE: Reliable planning of data center cabling OPTICAL SOLUTIONS & INFRASTRUCTURE

Cisco 100GBASE QSFP-100G Modules

Product information 19" 1U UniRack 24xLC-Duplex OM4, PC, ceramic, Bm/3 R816749

FEATURED PRODUCTS SC & LC MINI BOOTS LC-HD TOP ADAPTER XP-SERIES LC SWITCHABLE UNIBOOT IP-SERIES LC-KEYED FLEX BOOTS PLC-WDM

Construction Materials. Dimensions. Environmental Specifications. General Specifications. Mechanical Specifications

DIAMOND Fiber Optic Components

HP G Switch HP G-2SFP Switch HP G-2SFP+ 10G Uplink Switch HP G-PoE+ (124W) Switch

ProCliCk Pre-Polished ConneCtors

A Quick Start Guide to Fiber-to-theAntenna (FTTA) Installation and Maintenance Testing. Vol. 1 Certifying Next-Generation FTTA Cabling and Components

MTP/MPO Cable Assemblies

QuickSpecs. Models HP G Switch

Test Equipment Depot Washington Street Melrose, MA TestEquipmentDepot.com. FiberTEK III

Fiber Optic Technology 101. Principles and Advantages. When is fiber the ideal choice For your network? I n s c a p e D a t a C o r p o r a t i o n

3M Fibrlok Optical Splice System

PCS PATCH CORD SOLUTIONS PATCH CORD SOLUTIONS

Product Classification. General Specifications. Construction Materials. Dimensions. Environmental Specifications. General Specifications

LC Adapters and Cable Assemblies

Transcription:

Polymer Coated Fiber Cable (PCF) Panduit has introduced a Polymer Coated Fiber (PCF) to their fiber cable offering available in 50µm and 62.5µm core diameters. Along with this cable having a stronger durability than standard fiber cable, it is quick to deploy and easy to terminate in the field. These two characteristics make this cable a preferred fiber solution when mechanical integrity and reliability is a necessity in the fiber deployment. What are the general characteristics of PCF? Panduit offers PCF cable that has a graded-index (GI) core composed of pure silica (50µm or 62.5µm), a silica cladding layer (200µm), a silica hard coating layer (230µm), and a HDPE (high density polyethylene) primary coating (500µm). The profiles of the two different offerings are shown below: OM2 Multimode Graded Index (GI) Polymer Coated Fiber (PCF) 50/200/230 µm 50µm ± 3µm GI Core 200µm ± 4µm Silica Cladding Diameter 230µm ± 10µm Silica Hard Coating Diameter 50/200/230µm 500µm ± 30µm Primary Coating (Buffer) Diameter OM1 Multimode Graded Index (GI) Polymer Coated Fiber (PCF) 62.5/200/230 µm 62.5µm ± 3µm GI Core 200µm ± 4µm Silica Cladding Diameter 230µm ± 10µm Silica Hard Coating Diameter 500µm ± 30µm Primary Coating (Buffer) Diameter 62.5/200/230µm web: www.panduit.com e-mail: cs@panduit.com phone: 800-777-3300 page 1

What types of PCF are offered? The 50µm and 62.5µm PCF are offered in three types of cable construction and two colors; 2-fiber zip cord (orange outer jacket) and 2-fiber or 4-fiber breakout cable (black outer jacket). All of these have a riser/low smoke zero halogen rated high density polyethylene (HDPE) outer jacket. While the zip cords are rated for use indoors, the breakout cables can be used indoors and outdoors, water blocked per EIA/TIA-455-828, FOTP-82. The breakout cables include a fiberglass central strength member and ripcord to access the fiber buffer tubes contained within the outer jacket. Where can I use PCF? PCF is primarily used in applications that demand high mechanical integrity and reliability such as in utility control rooms, factory automation environments and indoor industrial manufacturing deployments. All these cables meet the appropriate environmental requirements outlined in Telecordia GR-409-Core and/or ICEA-S-83-596. The 2-fiber zip cord can be used internal to the control panel or zone enclosure where specific custom lengths are needed to help control cable management or where specific lengths of pre-made cords are not immediately available. If the zip cord is to be used external to the panel or enclosure an enclosed protection path (conduit or cable tray) is necessary to safeguard against damage to the cable. The zip cord has a short-term (installation) bend radius of 10mm and a long-term (installed) bend radius of 16mm with an operating temperature range from -65 to +125 C. The 2-fiber and 4-fiber breakout cable can be used external to the control panel or zone enclosure and does not need to be installed in a conduit system or closed pathway. Due to the robustness of this cable, it can be installed on J hooks or run on cable ladder but to ensure cable integrity, best case cable installation practices should be followed. The breakout cable has a short-term (installation) bend radius of 10mm and a long-term (installed) bend radius of 16mm with an operating temperature range from -65 to +125 C. How do I terminate the PCF? PCF is terminated using a cleave & leave no polish solution. This allows for quick termination without a procedure that is dependent upon technician experience. The special cleaving tool produces a high-quality end face while utilizing a totally mechanical process that minimizes the potential for termination error. web: www.panduit.com e-mail: cs@panduit.com phone: 800-777-3300 page 2

It is best to use a piece of adhesive based tape and just dab the tip of the connector ferrule to remove any contaminants on the fiber after termination. What are the Optical Characteristics of the PCF? The PCF cable has a higher loss characteristic than that of the standard multi-mode fiber cable, and is mostly utilized in point to point connections. This is due to the high insertion loss of a mated pair resulting from the non-polished cleave and leave termination. In general, a mated pair of PCF connectors averages from 1.5dB to 1.7dB. The table below shows the difference in the bandwidth and attenuation values associated with the different core sized PCF cable at the 850nm and 1300nm wavelengths. PCF is reliable for transmission speed deployments of 10/100/1000 MB from 10 s to 100 s of meters dependent upon the transceiver being utilized in the fiber link. How do I test the PCF link? Testing the PCF link is performed utilizing the standard testing procedures outlined in TIA-568-C (TIA-526-14A and TIA-526-7), test Method B (one jumper method). Although this connector and cabling solution has high loss, it still can be used in a horizontal cabling infrastructure with the insertion loss per mated pair specified at a maximum of 1.7dB. The PCF cabling and connector solution can be used in a 100BASE-FX application as horizontal cabling (two connector max) without having any effect on the signal being transmitted due to the high total link budget associated with the 100BASE-FX transmission solution. However, this PCF cabling and connector system was designed for point to point or switch to switch type applications and was not designed to be utilized in a horizontal cabling infrastructure. When testing the PCF Link utilizing a Fluke DTX-1800 with MFM2 Modules, please follow the following procedure: Setting up the Fluke DTX 1. On the Main unit, rotate the switch to Setup, and select Test Limit a. Select F1 (more) b. Scroll down and select Custom c. Select F1 (create) d. Create a name for the test limit. (PCF Connector Test) web: www.panduit.com e-mail: cs@panduit.com phone: 800-777-3300 page 3

2. After creating a name, use right arrow key to move over to Tab 2 a. Scroll down to Maximum Connector Loss and hit Enter b. Input the value 1.7dB (This is the IL spec for the PCF connector) c. Hit the Save button 3. Hit the Exit Button and proceed to Setting Reference Setting Reference Using Method B (One Jumper) On the Main unit, rotate the switch to SPECIAL FUNCTIONS, and select Set Reference. Prepare the reference cables by applying a 17mm mandrel wrap for 62.5um cabling and a 22mm mandrel wrap for 50um cabling approx. 12 from the SC Standard Grade connector to both cords. Inspect the connectors on the reference cords and clean if necessary. 1. Connect the Standard Grade SC connectors to the TX ports and the Reference Grade LC connectors (identified with reference grade label on the cord and labeled in the figure below as and ) to the RX ports on the tester as per the figure below. 2. When connectivity between the Main and Remote is established, the DTX will emit an audible chirp. 3. Press the test key on the Main Unit and a reference measurement will be taken. 4. When the test is complete press Save to ensure the reference value is saved to memory. a. 50um reference reading will be between -22.0dB and -24.0dB b. 62.5um reference readings will be between -18.0dB and -20.0dB web: www.panduit.com e-mail: cs@panduit.com phone: 800-777-3300 page 4

Testing PCF Connectors 1. Remove the LC connectors from the RX ports on the Main and Remote units. DO NOT REMOVE THE SC CONNECTORS FROM THE TX PORT. 2. On the Main unit, rotate the switch to AUTO TEST. 3. Add a second Standard Grade LC to Reference Grade LC patch cord to both the Main and Remote Connections. The standard grade LC connector plugs into the RX port on the Main and Remote and the Reference Grade LC will connect into the LC adapter. 4. Connect the PCF fiber cable and connectors as shown in the figure above. 5. When connectivity between the Main and Remote is established, the DTX will emit an audible chirp. 6. Press the test key on the Main Unit and the DTX will test both of the cables. It will give a Main to Remote result and a Remote to Main result. The Main to Remote result will be the result for the connector attached to LC adapter closest to the Main and the Remote to Main result will be the result for the connector attached to the LC adapter closest to the Remote. 7. Results should be under 3.4dB. (Total of 1.7dB for each PCF connector) web: www.panduit.com e-mail: cs@panduit.com phone: 800-777-3300 page 5