3M Indoor Building Entrance Terminal (IBET) 4790V and 4790VL Series

Similar documents
3M Indoor Protected Building Entrance Terminal (IBET) 4688V Series

3M Indoor Protected Building Entrance Terminal 4588V-QCS Series

3M Indoor Protected Building Entrance Terminal 4788V-QCS Series

Indoor Protected Entrance Terminal 4588 Series

4188, 4288, 4288-S and 4688 Protected Entrance Terminals

4888 and 4988 Outdoor Protected Entrance Terminals

3M Add-On Terminals 4220P (100, 200, 300 & 400 pairs)

3M Cross-Connect Cabinet Riser Installation Guide

3M Quick Connect System (QCS) 2814

3M DSLAM Mounting Bracket Kit J0746

3M Quick Connect System (QCS) 2811

A Full Range for Different Applications The STG2000 modules offer three different types of IDC circuits. The Network of Networks

3M I/O Connector Mounting Options and Hardware

3M Serial Advanced Technology Attachment (SATA) Connector Signal Plug, Boardmount, Surface Mount Right Angle and PTH Vertical

3M I/O Connector Mounting Options and Hardware

3M Constant Monitors WSMONITOR1, WSMONITOR 2, WSMONITOR3

3M Pak 100 Wiremount Plug Series

A significantly increased capacity compared to other techniques is achieved with the compact SID-C module.

Model 1100B CHG Terminator. Operating Instructions

3 Angled Connector Housing (MC) Installation

3M SLiC Fiber Splicing Workstation with Cleaver Arm

3M Mini-Clamp Socket 2 mm Boardmount, Straight Solder Tails 372 Series

3M Fiber Distribution Units 8400 Series

Mounting Bracket for 8 in. Charles Industries Pedestal for use with 3M Fiber Dome Terminal Closure FDT 08

3M Passive Optical Splitter Shelves and Modules

3M Boardmount Socket 2 mm x 2 mm Straight Surface Mount, Straight and Right Angle Plated Through-Hole 1502 Series

3M Cross-Connect Cabinets for Midspan Applications

C5C Cross-Connect System

3M Cold Shrink QS-III Inline Splice Kits 15 kv 5415A, 5416A, 5417A, 5417A-WG, 5418A and 5418A-WG

3M 4-Wall, Tripolarized Header.050".100" Latch/Ejector, PTH & SMT Straight, PTH Right Angle 810 Series

3M Fiber Dome Terminal Closures FDTC 08M and FDTC 08S External Drop Termination

For more information, visit: 3M Cold Shrink QS-III Splice a one-piece joint with wide range and geometric stress control

3M Cold Shrink QS-III Inline Splice Kits 25/28 kv 5456A, 5456A-WG, 5457A, 5457A-WG, 5458A and 5458A-WG

3 710 Splicing System 1

3M Fiber Dome Closure FDC 08S-A. 3M Fiber Dome Closure FDC 08S-B. Constructed of highly chemicalresistant

3M Cold Shrink QS-III Inline Splice Kits 35 kv 5535A and 5536A

Conductive Pressure Sensitive Cover Tape 2666

3M Duplex Polishing Machine 6851-E with Universal Dual Holder Instructions

3M Compact Coarse Wave Division Multiplexer (CCWDM) Module Installation

3M SLiC Fiber Aerial Terminal Closure 530 Internal for Direct Spliced Drop Terminations. 3M External Cable Assembly Module (ECAM) 12mm Drop Entry Kit

3M Textool BGA Test & Burn-In Sockets 1.00 mm, Types 0, I, II and III Open Top

PICO PROTECTOR PG-25 & PK-25 Series

Volition. VF-45 Singlemode Socket and Patch Cords. 3Innovation IT'S AS EASY AS PLUGGING IN AN RJ-45.

3M AEROSPACE & COMMERCIAL TRANSPORTATION DIVISION St. Paul, MN USA or or Made in USA

Start Here. All-in-One Printer. Print Copy Scan

3M Connectors for CFast Cards The Next Generation of Removable CompactFlash Storage

3M Fiber Distribution Units 8400 Series. The Network of Networks. Flexibility for. Networks. Growing

EMS. Electrical Management System. Progressive Industries Incorporated Morrisville, North Carolina

Installation Notes TII Model 341 Protector

Model 2460-KIT. Screw Terminal Connector Kit. Description / September 2014 *P * 1

3M Fibrlok II Angle Fiber Splice 2529-AS 3M Fibrlok 250 µm Angle Fiber Splice 2540-AS

Progressive Industries, Inc. EMS Electrical Management System

LA600WH WIRED / WIRELESS DOOR CHIME

3M Textool Open-Top Test and Burn-In Sockets for Ball Grid Array Packages

Volition. Multimode VF-45 Socket and Patch Cords. 3Innovation

3M Category 6 Copper Structured Cabling System

3M Workstation Monitor Checker CTE701A User s Guide

3M Sensored Cable Accessories for Underground Medium Voltage Distribution System

Volition. Multimode VF-45 Socket and Patch Cords. 3Innovation

3M Cold Shrink QS4 Integrated Splice Kits 35 kv

3M Wrist Strap and Ground Monitor 773. User s Guide

3M SlimLine 85ohm Cable Assembly

INSTALLATION AND USER GUIDE 2800MWB SINGLE LINE BASIC FEATURE TELEPHONE

3M Power Clamp System Power/Signal Distribution I/O Connector System

Choose the Right Interconnect Solutions for FTTH Drop Cable Installations

SPECIAL APPLICATION MANUAL PART NUMBER: TNP121UL. Tilt N Plug Jr. Table Top Interconnect Box USER'S GUIDE

Installing the NEMA 4X Hatch

3M Connectors for Embedded Systems Connectors for AdvancedTCA, CompactPCI and MicroTCA Systems from 3M

Visit us at

Instruction Manual. Electrical Management System (EMS) EMS-HW30C & EMS-HW50C

3M Data Center Solutions. Innovation. is the. Solution

Product Discontinuation Notice 3M Assorted Japan Sourced Connectors

SATA II HDD Canister KISS DA 435 Quick Reference Guide

Dynatel Advanced Modular System 965AMS ADSL2+ Service Module

Outdoor PTZ. Mounting on the Ceiling Using Pendant Mount. Installation Guide. For Models: I93, I94, I95, I96, KCM /12/03

SERVICE MANUAL MODEL SSW-520-F

3M Fiber Dome Closure Family. Reliable. Fiber. Protection

General Process Specification for Reflow Soldering of Boardmount 3M Pak Connectors, 3M CF Card Headers and 3M PCMCIA Sockets and Headers

CONNECTOR AND RECEPTACLE WIRE/CABLE ASSEMBLY INSTRUCTIONS

3M 100G QSFP28 Direct Attach Copper Cable Assemblies, 9Q Series

Installation Guide. Retrofit Kit for USB Ready Intraoral Systems

Crimplok ST* and SC Non-Adhesive Fiber Optic Single & Multi-mode Connectors

TDM-150 TIMER DISPLAY

BreezeMAX Wi² and BreezeACCESS Wi² Quick Installation Guide

MS 2. Modular Splicing System. Communication Markets Division

Dynatel.Advanced.Modular.System. 965AMS.VDSL2.Service.Module.

System Accessories. features and benefits. standards. An Evolant Solutions Product

Installation Instructions

CubePro. Main PCB Replacement Guide. Prosumer 3D Printer. Original Instructions

New Product Release Summary for 3M Authorized Sales Reps and Distributors 3M Industrial M12 Wiremount Connectors, 3N104 and 3N304 Series

Electrical Management System (EMS) EMS-HW30C & EMS-HW50C

CA-A480-A Elevator Controller. Reference & Installation Manual

KM-4800w. Installation Guide

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

DOOR INTERCOM SYSTEM WITH 2.4 COLOUR LCD

TrueNet 1U and 2U Fiber Panel Installation and Cable Routing Instructions

PICO PROTECTOR PG-06 & PK-06 Series

Explosion proof UL certified VoIP telephone. FernTel IP Z2 UL. Tabletop unit. Manual FHF BA /12

iconverter 2-Module Power Chassis

INSTALLATION AND USER GUIDE 2800LBY SINGLE LINE HOTEL LOBBY TELEPHONE

Transcription:

3M Indoor Building Entrance Terminal (IBET) 4790V and 4790VL Series with 3M Quick Connect System (QCS) 2811 Dry Flame-Retardant Block and RJ-11 Test Ports Instructions Underwriters Laboratories (UL 348X) Listed May 2012 3 78-0013-6389-0-A

1.0 General The 3M Indoor Building Entrance Terminals (IBET) 4790V-QCS and 4790VL-QCS Series provides electrical protection and a termination point for outside plant cable (feeder) and indoor house wiring (distribution). The 4790V and 4790VL IBETs provide a demarcation point between the switched telephone network and the thirdparty customer-premises equipment via an RJ-11 jack. These IBETs are Underwriters Laboratories (UL 348X) Listed. 1.1 Available 4790V-QCS /4790VL-QCS IBETs: 4790V/50-25/SD-A IBET 4790V/50-50/SD-A IBET 4790VL/100-100/SD-A IBET 4790V/50-25/DPM-FR-A IBET 4790V/50-50/DPM-FR-A IBET 4790VL/100-100/DPM-FR-A IBET 25-pair HiCat Indoor Building Entrance Terminal with 3M 710 Splicing System SD 50-pair HiCat Indoor Building Entrance Terminal with 3M 710 splicing system SD 25-pair HiCat Indoor Building Entrance Terminal with 3M 710 Splicing System SD 25-pair HiCat Indoor Building Entrance Terminal with 3M MS 2 Super Mini Splicing Module 4005-DPM/FR 50-pair HiCat Indoor Building Entrance Terminal with 3M MS 2 Super Mini Splicing Module 4005-DPM/FR 100-pair HiCat Indoor Building Entrance Terminal with 3M MS 2 Super Mini Splicing Module 4005-DPM/FR 1.2 IBET Terminal Parts and Components a) Connectorized tails with 3M flame-retardant modules. 3M MS² Super Mini Splicing Module 4000-D/CO, 3M MS² Fire Retardant Pluggable Module 4005-DPM/FR or 3M 710 Splicing System SD modules. b) Splice chamber (for the feeder cable) with cable strain relief. c) Insulated #6 ground strap for the feeder cable. d) External bottom-mounted, three-point ground bar and top-mounted, single-point ground bar. e) Numbered standard 5-pin protector receptacle field. f) Binding post log and instruction label. g) The 3M Single Pair Test Probe and Dish. h) Fully lockable protective cover. i) Three (3) screws (2 small and 1 large) to wall mount the IBET (Note diagram in section 2.0). 1.3 IBET Dimensions and Wiring Schematic Model Height Width Depth 4790V-QCS/50-25 4790V-QCS/50-50 4790VL- QCS/100-100 12.25" (311 mm) 12.25" (311 mm) 19.62" (498 mm) 21.04" (534 mm) 4.83" (123 mm) 6.80" (172 mm) 26 AWG Fuse Wire Module Protector RJ-11 2810 Block From C.O. 3M Indoor Building Entrance Terminal (IBET) 4790V-QCS and 4790VL-QCS Wiring Schematic 1.4 Protector Specifications Use ONLY UL Recognized or Listed five-pin protectors in the 4790V-QCS terminal. 1.5 Special Tools Needed to Splice 3M MS 2 modules or 3M 710 connectors (Not required if 3M Scotchlok Connectors are used) 2 78-0013-6389-0-A

2.0 3M Indoor Building Entrance Terminal Location and Mounting 2.1 Choose a location for the terminal according to your company s standard operating procedures. Consider the following points: a) Locate the terminal inside the building as close as possible to cable entrance. CAUTION Avoid locations near flammable materials, ignitable gases, dust, moisture, temperature extremes, moving machinery, electric light and power circuits, and electrical equipment. b) Locate the terminal on a firm mounting surface where it will be accessible to the technicians at all times; where it can be reached without a ladder; and where it will not project in a hazardous manner. c) Observe caution when exposing the terminal to chemicals in liquid or vapor form as they may damage the plastic components. 2.2 Open the splicing chamber by loosening the bolt securing the splicing chamber door. Open the splicing chamber door. 2.3 Pull the preterminated short stub, insulated ground wire, and accessories out of the splicing chamber. 2.4 Mount the terminal in designated position with the three mounting screws provided. Model 4790V-QCS/50-25 4790V-QCS/50-50 4790VL-QCS/100-100 Dimension A 9.0" (229 mm) 9.0" (229 mm) A Back of terminal: wall mounting keyholes 2.5 Remove the jumper wire retaining ring from poly bag and install in faceplate. 78-0013-6389-0-A 3

3.0 Feeder Cable Preparation and Strain Relief 3.1 Feeder cable diameters for the 3M Indoor Building Entrance Terminal (IBET) 4790V-QCS and 4790VL-QCS Series Minimum Diameter Maximum Diameter Entrance Cable 0.42" (10.7 mm) 1.45" (36.8 mm) If the cable diameter is smaller than the minimum, use Scotch Linerless Rubber Splicing Tape 130C to build up to the minimum. 3.2 Run the feeder cable 24" (610 mm) past the 3M Indoor Building Entrance Terminal (IBET) cable entry port. 3.3 Slide the 3M Pull N Shrink Tube (PST) on the end of the cable with the pull-tab away from the IBET and temporarily keep it out of the way. 3.4 With the groove toward the IBET and long end toward the cable, snap the cable gland halves around the cable. Slide the gland into the entry port of the IBET. 3.5 Measure 2" (51 mm) of sheath past the gland inside the IBET. Pull the gland and cable out of the IBET. 2" 3.6 Remove the sheath, leaving at least 21" (533 mm) of free conductor length. Identify and secure the cable groups ends. Bond the cable shield according to your company s practice. 3.7 Insert the gland s groove into the cable port. Slide the PST over the gland and slowly unwind the core. The PST core fits over the small diameter of the 25- to 50-pair gland. 3.8 Complete the PST core removal over the gland. 3.9 The blank plate MUST be used in the empty cable port for UL Listing. 3.10 Attach the cable to the wall according to your company s practice. 4 78-0013-6389-0-A

4.0 Terminal Grounding 4.1 Fasten a #6 AWG wire to the ground bar, which is located on the front of the unit. Connect the other end of the ground wire to local ground per company standards. Note: Failure to properly bond and ground the terminal per N.E.C. or local equivalent codes may render protection arrestors useless. 5.0 Splicing 5.1 Splice the feeder cable group(s) to the appropriate 3M Terminal Block Tail(s) per your company s practice. 5.2 Bundle completed 3M Splice Module(s) and secure them with 3M Cable Ties within the splice chamber. 5.3 Close the splice chamber cover and secure the lock plate bolt. 6.0 Terminating Premise Wire 3M Quick Connect System (QCS) 2811 Block 6.1 Open the feeder pair jumper cap by pushing up on the latch and rotating up. Insert wire ends A (tip) left and B (ring) right into wire openings in the cap, making sure they are inserted all the way to the back of the cap. 6.2 While holding the wires in place, close the cap and press to snap the latch firmly into place. 6.3 Route the wires through wire loops on the block ends and through vertical and horizontal wireways. 6.4 Terminate additional wires by repeating the above procedure. 6.5 To remove the wires, open the cap and pull the wires straight out from block. 6.6 Route the wire below the connected cap. 78-0013-6389-0-A 5

7.0 RJ-11 Test Jack/Demarcation Jack Ports 7.1 The user accessible RJ-11 test jack or demarcation jack port on both the 3M Indoor Building Entrance Terminal 4790V and 4790VL provide a loop disconnection point for isolating the wiring fault without the need to remove a jumper wire, customer premise wire or visit the customer premise. 7.2 To isolate the cable circuit, insert an RJ-11 jack into the corresponding RJ-11 test access port. Test Ports on the 3M Indoor Building Entrance Terminal 7.3 Inserting an RJ-11 jack into the test access port connects to the CO side of the loop while at the same disconnecting the 3M Quick Connect System (QCS) 2810 and customer premise cable. 7.4 This test access port does not provide for connection of the premise cable for testing purposes. 7.5 Testing of the customer premise cable can be accomplished by the inserting the 3M Single Pair Test Probe 2827 in the corresponding cable pair cap on the 3M Quick Connect System Block 2811 and attaching test equipment to the test pair lugs. 7.6 The cable pair circuit will remain disconnected until the test jack is removed from the test access port. To restore the circuit, remove the test jack. 3M Indoor Building Entrance Terminal 4790V-QCS 50-pair 6 78-0013-6389-0-A

8.0 Installing the Electrical Protectors Note: Use ONLY UL Recognized or Listed protectors in the IBET terminal. 8.1 The 3M Indoor Building Entrance Terminal (IBET) 4790V-QCS and 4790VL-QCS uses a standard five pin protector receptacle field. The long pins of the protector connect Tip and Ring from the feeder cable though the protector to the short pins to the distribution/house wire. 8.2 Insert protectors into the protector receptacle field according to your company s practice. 8.3 To disconnect the distribution wire, pull the protector out to the detents on the long pins to hold it in place. This continues to protect from the feeder cable side. 9.0 Protective Cover 9.1 With the cover closed, the exposed hasp allows for locking when security is required. 10.0 3M Single Pair Test Probe 2827 10.1 Plug the test probe into the cap of the pair being tested, with the black lead to the left and the red lead to the right. 78-0013-6389-0-A 7

11.0 3M Priority Caps 11.1 Priority caps are used to designate special purpose circuits and prevent entry of the 3M Single Pair Test Probe. 11.2 To install priority caps, place over the jumper cap of the pair to be marked and push it into place. Latching is indicated by an audible snap. 12.0 Multiple 3M Indoor Building Entrance Terminal (IBET) 4790V-QCS and 4790VL-QCS Installation Note: Use this application when the required cable pair capacity exceeds the capacity of a single IBET. 12.1 The design of the splice chamber and the grooved cable glands make it possible to stack the IBET vertically, up to three of the same cable pair count and within the diameter limits in the chart in 3.1. 21" (533 mm) 12.2 Mounting the IBET a) Mount the IBET bodies using the cable glands to position them. b) Assemble the feeder cable strain relief according to Section 3.0 and prepare the feeder cable so that 21" (533 mm) of free conductor length will be in the last IBET. 1" (25 mm) minimum 2.75" (70 mm) minimum 8 78-0013-6389-0-A

12.3 Place cable glands around the free conductors and position into the 3M Indoor Building Entrance Terminal (IBET). 12.4 Separate the feeder cable pair assigned to each IBET; splice and bond the IBET according to section 4.0. 843017 78-0013-6389-0-A 9

3M, Scotch, MS 2 and Scotchlok are trademarks of 3M Company. Important Notice All statements, technical information, and recommendations related to 3M s products are based on information believed to be reliable, but the accuracy or completeness is not guaranteed. Before using this product, you must evaluate it and determine if it is suitable for your intended application. You assume all risks and liability associated with such use. Any statements related to the product which are not contained in 3M s current publications, or any contrary statements contained on your purchase order shall have no force or effect unless expressly agreed upon, in writing, by an authorized officer of 3M. Warranty; Limited Remedy; Limited Liability. This product will be free from defects in material and manufacture for a period of one (1) year from the time of purchase. 3M MAKES NO OTHER WARRANTIES INCLUDING, BUT NOT LIMITED TO, ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. If this product is defective within the warranty period stated above, your exclusive remedy shall be, at 3M s option, to replace or repair the 3M product or refund the purchase price of the 3M product. Except where prohibited by law, 3M will not be liable for any indirect, special, incidental or consequential loss or damage arising from this 3M product, regardless of the legal theory asserted. 3 Communication Markets Division 6801 River Place Blvd. Austin, TX 78726-9000 1-800-426-8688 www.3m.com/telecom Please Recycle. Printed in USA. 3M 2012. All Rights Reserved. 78-0013-6389-0-A