GSM HOME SECURITY SYSTEM

Similar documents
Humidity + Temp. + Dew Point Pocket size HUMIDITY METER. Model : HT-315

DATALOGGER. SD card, real time OPERATION MANUAL. Model : DL-9602SD

AC/DC MAGNETIC METER

AC/DC MAGNETIC METER OPERATION MANUAL. Model : MG G ( Gauss), mt ( milli Tesla ), USB/RS232. Your purchase of this

one probe, SD card real time data recorder CO2, %RH, Temp., Dew point, Wet bulb CO2 METER + HUMIDITY/Temp. Model : CO2-9914SD

AC/DC MAGNETIC METER OPERATION MANUAL. Model : PCE-MFM G ( Gauss), mt ( milli Tesla ), USB/RS232. Your purchase of this

600 g x 0.02 g DIGITAL BALANCE

UP100-GSM. GSM based intercom and access control. Installation and user manual

MobilGate - 128d. 1. Operation of MobilGate-128d. Gate and barrier control GSM module with 2 inputs and 2 outputs for 128 phone numbers

OPERATION MANUAL. Carbon monoxide 0 to 1000 PPM, Temp. CO METER. Model : GCO-2008

OPERATION MANUAL. SD card real time datalogger, RS232/USB PRESSURE METER. Model : PS-9303SD. Your purchase of this PRESSURE METER with

A1000 GSM ALARM DEVICE

OPERATION MANUAL. SD card real time datalogger HUMIDITY/TEMP. MONITOR. Model : MHT-381SD

12 channels TEMPERATURE RECORDER Model : BTM-4208SD

LED LIGHT METER OPERATION MANUAL. Model : LX-1148SD. SD card real time Data Recorder 10 Light Source select, Auto range 0 to 50,000 LUX

3 in 1, Type K/J, Pt 100 ohm, Infrared Thermometer Real time data logger, Data logger no., RS232 THERMOMETER.

OPERATION MANUAL. SD card real time datalogger, RS232/USB VIBRATION METER. Model : VB-8206SD

Installation Manual. GSM-3V/AB & ABK V3.5 (1200 keypad) Wiring. Important Notes: SIM card. Installation

OPERATION MANUAL. SD card real time datalogger 3 channels 4-20 ma CURRENT RECORDER. Model : MMA-386SD

USER MANUAL Mobeye Smoke Detector CM2400 Mobeye Heat Detector CM2400H. SW version 3.n

I. PANEL DESCRIPTION... 1

OPERATION MANUAL. SD card real time Data Recorder SOLAR POWER METER. Model : SPM-1116SD

USER MANUAL. Mobeye WaterGuard-FS. Float sensor CM2300FS. SW version 5.n

OPERATION MANUAL. SD card real time data Recorder, USB/RS232 SOUND LEVEL METER. Model : SL-4023SD. Your purchase of this

OPERATION MANUAL. SD card real time datalogger 3 Channels TEMPERATURE DATA RECORDER. Model : MTM-380SD. Your purchase of this 3

USER MANUAL Mobeye CM-Guard CM2000

GSM AD05 Slave GSM Auto Dialer- Instruction Manual

ANEMOMETER OPERATION MANUAL. Model : AM-4207SD. SD card real time datalogger + Type K/J thermometer

CONDUCTIVITY METER OPERATION MANUAL. Model : CD-4322

InTimeGo-623 Pets GPS Tracker User Manual

Verify with your service provider that their Mini SIM card will work with GSM / 3G GSM type modems before purchasing their Mini SIM card.

Clamp meter with Data recorder SERIES set

SD Card real time data recorder + type K/J TEMP. CUP ANEMOMETER

DATA LOGGER (Version V1.3)

SS91A-M GSM DOOR PHONE (ACCESS CONTROL SYSTEM)

Digital Keypad Introduction

A1400 GSM Temperature Alarm USER MANUAL A1400-REV FW-A1400v2.94. ERBAŞ TEKNOLOJİ Innovative Solutions. 1

GSM Communicator GJD710 PLEASE READ THESE INSTRUCTIONS CAREFULLY BEFORE YOU START THE INSTALLATION

InTimeGo-630 GPS Watch Tracker User Manual

VIBRATION METER Model : VB-8213

ZD-VT1 User Guide. ZENDA GPS Tracker ZD-VT1 User Guide

DPM Digital DC Power Meter with Data logging capability. User Manual

GV-Card Reader. User s Manual

HOT WIRE ANEMOMETER. Model : 204HA

PLEASE READ BEFORE INSTALL. ECGO-GKP Cellular Telephone Entry

DPM-3221 Digital DC Power Meter with data logging capability.

DIGITAL MULTIMETER 4 1/2 digits, True RMS Model : DM-9027T

SMS Transceiver V3 User manual

TORQUE WRENCH OPERATION MANUAL. Model : TQ Kgf-cm, heavy duty, professional

ST-908 User Manual GPS Vehicle Tracker

SS91A-M GSM DOOR PHONE (ACCESS CONTROL SYSTEM)

900E Vehicle GPS Tracker User Manual

User Manual. PCKeypad Wireless Keypad

Pocket type SOUND LEVEL METER Model : SL-4030

Innovative Electronics for a Changing World. NPM-R10 Remote Network Power Monitor. With optional relay board and GSM module INDEX

GSM communicator GD-06 Allegro Complete manual

RCW-400A USER GUIDE. Version 1.1

OPERATION MANUAL. UVA and UVB measurement UV LIGHT METER. Model : YK-35UV

TA 888 Hot Wire Anemometer

OPERATION MANUAL. UVA and UVB measurement UV LIGHT METER. Model : YK-35UV

Single Door Standalone Access Control User Manual

Sound Level Meter SL-4035SD. Operation Manual PLEASE READ THIS MANUAL CAREFULLY BEFORE OPERATION

User Manual. GSM Fixed Wireless Phone (Model: GSM-938) Introduction

Air velocity, Air flow, Type K/J thermometer Real time data logger, Data logger no., RS232 ANEMOMETER. Model : DAF2005MDL

OPERATION MANUAL. auto range + type K Temp. optional Humidity, Light, Anemometer SOUND LEVEL METER Model : SL-4112

OPERATION MANUAL. SD card real time datalogger HEAT INDEX WBGT METER. Model : WBGT-2010SD

GSM SECURITY AND CONTROL SYSTEM ESIM021

INDEX. Network Power Monitor R10 SNMP

Wireless Key fob, Key pad & Receiver Range

SHIMPO INSTRUMENTS. FG-7000T Digital Torque Gauge Operation Manual

INSTRUCTION MANUAL FOR TQ-8800 TORQUE METER PLEASE READ THIS MANUAL CAREFULLY BEFORE OPERATION

Operating Instructions VEGAMET 381

WT-1010C2 GSM ALARM SYSTEM

Digital Multimeter Instruction Manual

CAMit I Camera with built in Modem

Manual Digital Thermometer PCE-T 390

GSM Communicator GJD710 PLEASE READ THESE INSTRUCTIONS CAREFULLY BEFORE YOU START THE INSTALLATION COMMUNICATOR FIT INSTALLATION INSTRUCTIONS

OPERATION MANUAL. ph/mv SD card real time data logger ph METER. Model : PH-230SD

VISTA 12a / 48a TECHNICAL TRAINING. The Best in Security plus Everyday Convenience & Control

OPERATION MANUAL. separate probe, RS-232 SOUND LEVEL METER. Model : SL-4013

M170 USER'S / INSTALLER'S MANUAL V1.1 REV. 11/2016

Model SFS01-V2 IMPORTANT! MULTI-ATTEMPT AUTOMATIC ENGINE SMART SWITCH

MANUAL DOOR INTERCOM 3G AUDIO KEYPAD INTERCOM (ACCESS CONTROL SYSTEM) For 200 Apartments. For your protection, read these instructions completely

Wireless keypad PRF-LCD-WRL

GSM Fixed Wireless Terminal WT User s Manual

MobilSwitch-5c. 1. Operation of the GSM device: Multi channel GSM signaling and remote control unit with analog, digital, counter inputs

RPX Series USER S MANUAL

OPERATION MANUAL. Pen type, air oxygen and Temp. O2 METER. Model : PO2-250

Electro Magnetic Compatibility (EMC)

CV-550SPK V2 Waterproof Keypad/Reader/Controller Installation Instructions

Multifunction Calibrator

DIGITAL ANEMOMETER Model : AM-4203

Subject. Model. Summary. DECOS IIIj USB Function. LXE10E100 series (DECOSIIIj) USB Port. No.SB

UC-2000 Installation Manual Unicorn Computers Technology Limited

CCTR-630 GPS Watch Tracker User Manual ---V1

MobilTherm 2ad. 1. How the interface works: GSM temperature alarm module with auxiliay inputs and relay outputs

VIS-3200 / VIS-3201 User Manual

SafeLine GL5. Installation manual. A GSM alternative for all of our lift telephones with built-in power supply and battery backup.

MANOMETER OPERATION MANUAL. 200 mbar, differential input. Model : PM-9102

FG-7000L Digital Force Gauge Operation Manual

Transcription:

Cell /Mobile phone home security system GSM HOME SECURITY SYSTEM Model : BS120

TABLE OF CONTENTS 1. FEATURES... 1 2. APPLICATION... 2 3. SPECIFICATIONS... 3 4. FRONT PANEL & LAYOUT DESCRIPTION...6 5. BASIC OPERATION PROCEDURES... 10 6. SIM CARD ACQUISITION and INSTALL... 12 7. PREPARING OF OPERATION... 13 8. FUNCTION SETUP...14 8-1 TEL ( Telephone )...14 8-2 TIME...16 8-3 RELAY... 21 8-4 SAVE... 21 9. SMS COMMAND from MOBILE SMS CONFIRM from SYSTEM ERROR SMS COMMAND CONFIRM SMS from SYSTEM...22 10. IMPORTANT OPERATION PROCEDURES and CONSIDERATION...28 11. TROUBLE SHOOTING... 32 12. OPTIONAL ACCESSORIES... 34 12-1 Wireless Buzzer... 34 12-1 Wireless Relay...34

1. FEATURES * Home security system via GSM mobile phone, no distance limitation. * If the house is happened the unusual interrupt, user's mobile phone will receive the alarm SMS message immediately. * Two wireless detect switches ( DS-121, included ), user can install the DS-121 on the door or window easily. When the thief interrupt the house, buzzer will sound and send the SMS alarm message to the mobile. * Build in alarm buzzer output, wire buzzer is the standard accessory. Wireless alarm buzzer ( WB-122 ) is available as the optional accessory. * Build in one relay output, user can control ( ON/OFF ) the home electrical equipment via the mobile phone. * Wireless relay ( WR-123 ) is the optional accessory. When user intend to control the electrical appliance, it is not necessary use the wires to connect the main system if via WR-123. * Allow to preset three telephone no., alarm SMS will be send to three users in sequence. * After the SMS command send by mobile phone, the confirm message will be send back to the mobile, safety and no loss. * SMS delay time, SMS repeat time, buzzer delay time, buzzer repeat time can be preset flexibly. * Dot matrix LCD display with back light, can display all the system information clearly. * All setting value will be saved into EEPROM IC, no loss. 1

* Mobile telephone can call the status of the system. * Mobile telephone can ON/OFF the alarm function. * Build GSM mobile modem ( dual band, 900/1800 MHz ). * Easy operation and installation, can D.I.Y by the user. * Few and limit SMS command. Intelligent application, innovation, wide range, no limitation. 2. APPLICATION * Home security system. * Building supervision. * Industrial security system. * Remote control the electrical system ( Lighting, Pump, Heater, Refrigerator, Pets feeder.. ) 2

3. SPECIFICATIONS DISPLAY Dot-matrix LCD with back light 16 characters x 2 line. GSM Modem 900/1800 MHz, dual band. LED 7 LED Indicators : Indicators GSM indicator System indicator SMS alarm indicator Buzzer alarm off indicator Detect switch indicator Buzzer indicator Control relay indicator Detect Switch * Whole system included two " Wireless Inputs detect switches " ( DS-121 ) as the standard accessories. User can install DS-121 on the door or window easily. When the thief interrupt the house, the buzzer will sound and send the SMS warning message to the mobile phone. * If need more doors ( windows ) to install the extra " Wireless detect switches ", the DS-121 is offered as the optional accessory. * No number of the DS-121 that can be installed are no limited. Any DS-121 is interrupted, the system will send the warning alarm message to mobile. 3

Buzzer Output Buzzer output terminal can connect the " Wire buzzer " ( standard accessory ). When thief interrupt the house, the buzzer will sound. Relay Output * Build one control relay output ( NO, normal open ), user can control the home electrical appliance via mobile phone. * Max. load of control relay : 1 ACA/250 ACV 1 DCA/24 DCV Wireless Can cooperate the " Wireless Buzzer " Buzzer ( WB-122, optional ). User can hide Interface the main system of BS120 and only present the WB-122 in the obviously place, then the thief will not find the main system ( BS120 ) easily. Wireless Can cooperate the " Wireless Relay unit " Relay Interface ( WR-123, optional ). User intend to control the electrical appliance, it is not necessary use the wires to connect to the main system if via WR-123. Frequency of 433.92 MHz. Wireless Detect Switch Standard CE conformity Operating 0 to 50 ( 32 to 122 ) Temperature Operating Less than 80% RH. Humidity 4

Power supply Main unit DC 9V, via adapter in. Detect Switch Battery, 006P, DC 9V. Power Main unit GSM module working : consumption * Buzzer silent Approx. DC 210 ma GSM module standby : Approx. DC 125 ma Detect Switch Normal : No current consumption. Interrupt : DC 5.8 ma Size Main unit 193 x 149 x 46 mm. ( 7.6 x 4.9 x 1.8 inch ). Detect Switch 110 x 34 x 26 mm. ( 4.3 x 1.3 x 1.0 inch ). Weight Main unit 500 g ( 1.1 LB ). Detect Switch 87 g ( 0.19 LB ). * Included battery Accessories * Operation manual... 1 PC includes Optional Accessories * Wireless detect switch, DS-121... 2 sets * AC 100V-240V/DC ( 9V, 1.7A ) power adapter... 1 PC * Separate Antenna... 1 PC * Buzzer with two wires... 1 PC * Double side stick sponge... 2 sets Wireless detect switch, Model : DS-121 Wireless Buzzer unit, Model : WB-122 Wireless Relay unit, Model : WR-123 5

4. FRONT PANEL & LAYOUT DESCRIPTION Fig. 1 Fig. 2 6

Fig. 3 Fig. 4 Fig. 5 Connect the " Wire Buzzer " to this terminals, " Red wire " to " + " terminal, Black wire " to " - " terminal. 7

Main system 4-1 DC 9V power adapter socket 4-2A Antenna socket 4-2B Antenna plug 4-2C Seperate antenna 4-3 Power ON/OFF switch 4-4 GSM indicator 4-5 LCD display 4-6 System indicator 4-7 SMS alarm indicator 4-8 Buzzer alarm indicator 4-9 Numerical buttons 4-9A SMS Alarm ON/OFF button 4-9B Buzzer Alarm ON/OFF button 4-9C Alarm ON/OFF button 4-10 Detect switch indicator 4-11 Buzzer indicator 4-12 Control relay indicator 4-13 button 4-14 button 4-15 + - button 4-16 Decimal button 4-17 ENTER button 4-18 SETUP button 4-19 RESET button 4-20 Wireless buzzer interface terminal 4-21 Wireless relay interface terminal 4-22 Wire terminals ( Buzzer, Relay terminals ) 4-23 Terminal instruction label 4-24 Fix hole for wall installation 4-25 Fix hole for wall installation 4-26 SIM card holder 4-27 Screws for the SIM card cover 4-28 Passwords DIP switch of main system. 8

DS-121 Detect Switch 4-29 Power indicator 4-30 Low battery indicator 4-31 Power slide switch 4-32 Magnetic sensor 4-33 Battery cover ( DIP switch cover ) 4-34 Fix hole for wall installation 4-35 Antenna of DS-121 4-36 Passwords DIP switch of DS-121 4-37 Battery Fig. 6 9

5. BASIC OPERATION PROCEDURES 1)Insert the SIM card into the " SIM card holder ". Refer page 12. 2)Connect the " Antenna plug " ( 4-2B, Fig 2 ) to the " Antenna socket " ( 4-2A, Fig. 2 ) 3)Power ON ( 4-3, Fig. 1 ) the main unit. Check if the " GSM indicator " ( 4-4, Fig. 1 ) is under normal condition, refer page 13, page 14. 4)Key in the Tel. Number. Refer page 14, page 15. 5)Key in the Time value. Refer page 16, page 17, page 18. 6)Used " Double side stick sponge " ( Attach accessory ) to install the Wireless Detect Switch ( main unit and the magnetic unit ) on the door or window. 10 Double side stick sponge

7)Install the DC 9V battery into the Wireless Detect Switch ( 4-37, Fig. 6 ). 8)Connect the Wire Buzzer to the " Wire Terminals " ( 4-22, Fig. 3 ) 9)Make sure the " SMS alarm " and the " Buzzer alarm " already set to ON function. ( 4-9A, 4-9B, 4-9C, Fig. 1 ) 10) Power ON the Wireless Detect Switch ( 4-31, Fig. 6 ) 11) Rest the main unit by pushing the " RESET button " ( 4-19, Fig. 1 ), then leave the home. 12) When arrive home, just push the " ALARM button " ( 4-9C, Fig. 1 ) will OFF the alarm system. 11

6. SIM CARD ACQUISITION and INSTALL 1)Obtain your personal SIM card from the mobile telephone company of your choice. You will receive a telephone number and a PIN code with your SIM card. 2)Cancel the SIM card's PIN code. ( No PIN code when use the SIM card ) The procedures to cancel the PIN code, please use your own mobile to proceed as the instruction manual. Note : To cancel the PIN code is the necessary procedures, otherwise your GSM system will be not working properly. 3)To guarantee flawless operation of your GSM Control System, ensure that adequate signal strength is permanently to and from your mobile telephone network. Check this with your mobile before installation. 4)Open the SIM card cover by loosing the " Screws for the SIM card cover " ( 4-27, Fig. 4 ). Install the SIM card properly into the " SIM card holder " ( 4-26, Fig. 4 ). 12

7. PREPARING OF OPERATION 1)Install the SIM card, refer page 12. 2)Install the antenna to the Antenna socket " ( 4-2, Fig. 1 ) properly. 3)Connect the plug of the Power Adapter into " DC 9V power adapter socket " ( 4-1, Fig. 1, Fig. 2 ) 4)Power on the unit by engage the " Power ON/OFF switch " ( 4-3, Fig. 1, Fig 2 ) to the ON position. 5)LCD display, System indicator and Output indicator : * The LCD will lit and count down from 90 seconds back to 0 second then present the SETUP SCREEN ( refer page 14 ). * The " System indicator " ( 4-6, Fig. 1 ) will flash ( per 1 second On, 1 second Off ) if the CPU Circuit working properly. 6)GSM indicator ( 4-4, Fig. 1 ) a. If the GSM modem is not connecting the mobile network, the " GSM indicator " will flash per 0.6 second On and 0.6 second Off. 0.6 second On 0.6 second Off 13

a. If the GSM modem connect to the mobile network properly, the " GSM indicator " will flash per 0.075 second On and 3 second Off. 0.075 second On 3 seconds Off 8. FUNCTION SETUP 8-1 TEL ( Telephone ) Press the " SETUP Button " once, LCD will show SETUP SCREEN 1:TEL 2:TIME SETUP SCREEN 3:RELAY 4:SAVE * key in " 1 ", LCD will show Telephone Num. 1 + 14

* Use the " button " to select the " TEL " setting screen ( a. b. c. d. ) as : a Telephone Num. 1 TEL 1 SETTING SCREEN + @ Enter the first mobile telephone no. @ Telephone no. starting with + country code ( For example, Germany is +49, Taiwan is +886, Hong Kong is +852...) @ For example key in +886919562822 b Telephone Num. 2 TEL 2 SETTING SCREEN + @ Enter the second mobile telephone no. @ The procedures are same as the above TEL 1 setting. c Telephone Num. 3 TEL 3 SETTING SCREEN + @ Enter the third mobile telephone no. @ The procedures are same as the above TEL 1 setting. * If only need one mobile phone to receive warning message, it just key in one telephone no ( Telephone Num. 1 ). * If need two mobile telephones to receive warning message, it just key in two telephone no ( Telephone Num. 1, Telephone 2 ). * After finish to key in the desired telephone no., should key in the " ENTER " button. 15

* Before finish the " TEL " setting, it should key in " SETUP Button " to return the SETUP SCREEN. 1:TEL 2:TIME SETUP SCREEN 3:RELAY 4:SAVE Then key in " 4 " ( SAVE ), LCD will show : Save OK! SETUP->Exit 8-2 TIME Time setting function is used to set the following time values : @ SMS delay time @ SMS period time @ Buzzer delay time @ Buzzer repeat time SMS delay time SMS period time Interrupt happened Buzzer delay time Buzzer repeat time Interrupt happened 16

Press the " SETUP Button " once, LCD will show : 1:TEL 2:TIME SETUP SCREEN 3:RELAY 4:SAVE SMS Delay Time SETTING * key in " 2 ", the show the SMS Delay time setting screen : SMS Delay :xs SMS Delay Time SETTING SCREEN (0-99)SEC : @ Used the " Numerical buttons " ( 4-9, Fig. 1) to set the desired SMS Delay time is second, then push the " ENTER button " ( 4-17, Fig. 1 ) will entry the new SMS Delay time. @ The SMS Delay time setting range is 0 to 99 seconds. SMS Period Time SETTING * After finish the SMS Delay time setting, push the " button ", will show the SMS Period Time setting screen : SMS Period :xm SMS Period Time SETTING SCREEN (1-20)min : @ Used the " Numerical buttons " ( 4-9, Fig. 1) to set the desired SMS Period time is minute, then push the " ENTER button " ( 4-17, Fig. 1 ) will entry the new SMS Period time. @ The SMS Period time setting range is 1 to 20 minutes. 17

Buzzer Delay Time SETTING * After finish the SMS Period time setting, push the " button ", will show the Buzzer Delay Time setting screen : Buzzer Delay :xs (0-99)sec : Buzzer Delay Time SETTING SCREEN @ Used the " Numerical buttons " ( 4-9, Fig. 1) to set the desired Buzzer Delay time is second, then push the " ENTER button " ( 4-17, Fig. 1 ) will entry the new Buzzer Delay time. @ The Buzzer Delay time setting range is 0 to 99 seconds. Buzzer Repeat Time SETTING * After finish the Buzzer Delay time setting, push the " button ", will show the Buzzer Repeat Time setting screen : Buzzer Rep :xm (0-99)min : Buzzer Repeat Time SETTING SCREEN @ Used the " Numerical buttons " ( 4-9, Fig. 1) to set the desired Buzzer Repeat time in minutes, then push the " ENTER button " ( 4-17, Fig. 1 ) will entry the new Buzzer Repeat time. @ The Buzzer Repeat time setting range is 0 to 99 minutes. 18

Relay Time SETTING * After finish the Buzzer Delay time setting, push the " button ", will show the Relay Time setting screen : Relay Time : xx.xm (0.1-99.9) : Relay Time SETTING SCREEN @ Used the " Numerical buttons " ( 4-9, Fig. 1) to set the desired Relay time in minutes, then push the " ENTER button " ( 4-17, Fig. 1 ) will entry the new Relay time. @ The Relay time setting range is 0.1 to 99.9 minutes. @ When mobile send the " CONTROL " SMS ( refer page 23 ), the control relay will be ON ( action ) WITHIN the time according the Relay Time Setting value. Control Relay ON according Relay Time Setting value. Mobile send CONTROL " SMS 19 Off

Time Default Value SETTING If the user intend to entry the Time value as the default value, then after finish the Buzzer Repeat time setting, push the " button ", screen will show : Set to Default Press Enter Key Then push the " ENTER button ", ( 4-17, Fig. 1 ) will entry the default time value as follow : @ SMS delay time = 20 seconds @ SMS period time = 3 minutes @ Buzzer delay time = 20 seconds @ Buzzer repeat time = 5 minutes @ Relay time = 0.1 minutes Save the Time Setting Value * Before finish the " TIME " setting, it should press " SETUP Button " once to return the SETUP SCREEN : 1:TEL 2:TIME SETUP SCREEN 3:RELAY 4:SAVE Then key in " 4 " ( SAVE ), LCD will show : Save OK! SETUP->Exit 20

8-3 RELAY Relay setting function is used to set the control relay output is ON or OFF. Press " SETUP Button " once to return the SETUP SCREEN : 1:TEL 2:TIME SETUP SCREEN 3:RELAY 4:SAVE key in " 3 ", will show the RELAY setting screen : Relay : OFF Relay SETTING SCREEN (1) ON (2) OFF Used the " Numerical buttons " ( No. 1 or 2 ) to set Relay to be ON or OFF, then push the " ENTER button " ( 4-17, Fig. 1 ) will entry the relay condition. 8-4 SAVE * After the system are already change the data ( value, function ), it should press " SETUP Button " to return SETUP SCREEN. 1:TEL 2:TIME SETUP SCREEN 3:RELAY 4:SAVE Then key in " 4 " ( SAVE ), LCD will show : Save OK! SETUP->Exit @ The setting procedures are finished completely, the change data, value and the function will be saved into the memory circuit. 21

9. SMS COMMAND from MOBILE SMS CONFIRMATION from SYSTEM ERROR SMS COMMAND ALARM SMS from SYSTEM 9-1 SMS COMMAND from MOBILE SMS CONFIRMATION from SYSTEM There are 6 types of SMS command that can be send from the mobile are : ALARM-ON ALARM-OFF RELAY-ON RELAY-OFF RELAY-TIME X.X CONTROL CHECK RESET ALARM-ON SMS command from mobile to set the both SMS alarm and the BUZZER alarm function are ON ( Available ). 22

ALARM-OFF SMS command from mobile to set the both SMS alarm and the BUZZER alarm function are OFF ( Disable ). RELAY-ON SMS command from mobile to set the Control Relay to be ON. RELAY-OFF SMS command from mobile to set the Control Relay to be OFF. RELAY-TIME xx.x SMS command from mobile to set the value of Control Relay Time. Relay time can be se from 0.1 minute to 99.9 minutes. For example : RELAY-TIME 9.9 Relay time set value is 9.9 minutes. RELAY-TIME 20.3 Relay time set value is 20.3 minutes. CONTROL SMS command from mobile to let the Relay ON ( action ) according the above " RELAY-TIME " value For example : If the relay time value is 20.3 minute, then when send the " CONTROL " SMS, the control relay will be ON within 20,3 minutes. 23

CHECK SMS command from mobile to check details of the system condition. RESET SMS command from mobile to reset the system to the initial condition. For example, After mobile send the SMS ( ALARM-ON, ALARM-OFF, RELAY-ON, RELAY-OFF, CHECK ) to the system, the mobile will get the SMS confirmation from the system back as similar as following : Trouble! Show the system is under Trouble! or Normal Detect Switch: Show the Wireless OFF Detect Switch condition : ON or OFF Control Relay: Show the Control Relay OFF condition : ON or OFF R-Time,Set: xx.x Buzzer output Silent Buzzer Alarm ON SMS Alarm ON Relay time set value Show the Buzzer output condition : Silent or Sound Show the Buzzer Alarm status : ON or OFF Show the SMS Alarm status : ON or OFF 24

RESET @ SMS command from mobile to reset the system. @ After mobile send the " RESET " SMS command to the system, the system will not send any SMS confirmation to the mobile, it just to execute the reset function to the system only. @ After the reset function is executed, the Control Relay output will set to OFF automatically. 9-2 ERROR SMS COMMAND If the mobile send the wrong or illegal SMS command to the system, the system will send the following SMS back to mobile to hint operator that the SMS command is wrong : WRONG INSTRUCTIONS! 25

9-3 CONFIRM SMS from SYSTEM If any interrupt from the Wireless Detect Switch the mobile will receive the following warning message as example : Trouble! Show the system is under Trouble! or Normal Detect Switch: Show the Wireless ON Detect Switch condition : ON or OFF Control Relay: OFF R-Time,Set: xx.x Buzzer output Silent Buzzer Alarm ON SMS Alarm ON Show the Control Relay condition : ON or OFF Relay time set value Show the Buzzer output condition : Silent or Sound Show the Buzzer Alarm status : ON or OFF Show the SMS Alarm status : ON or OFF 26

If mobile send the SMS " RELAY-TIME xx.x " out. mobile will receive the following message for example as : Relay Time : 9.9 Min. If mobile send the SMS " CONTROL " out., mobile will receive the following message as example : CONTROL : Execute Relay time, Balance : 9.9 Min. To show relay setting time. 27

10. IMPORTANT OPERATION PROCEDURES & CONSIDERATION 1)The position of Passwords DIP switch of main system ( 4-28, Fig. 4 ) Passwords DIP switch of DS-121 ( 4-36, Fig. 6 ) should slide at the same position. If the Wireless Detect Switch is interrupted by others, then it should change to the new DIP switch position for both unit. 28

2)If system under normal operation, the LCD display should select to the Regular SCREEN, other wise the system can not accept SMS in or send the SMS out. * Push the " SETUP Button " once again, the LCD will change from SETUP SCREEN to Regular SCREEN alternatively. * If the user do not change to SETUP SCREEN to Regular SCREEN, within certain period the screen will change to Regular SCREEN automatically. a. SETUP SCREEN 1:TEL 2:TIME SETUP SCREEN 3:RELAY 4:SAVE b. Regular SCREEN If the LCD already present any Regular SCREEN, it can use the " Button " or " Button " to select the following five kinds Regular SCREEN 1 Buzzer : Silent Regular SCREEN Relay : OFF * Show Buzzer condition ( Sound /Silent ) and Relay condition ( ON/OFF ). 29

2 SMS Alarm :ON Regular SCREEN Buzzer Alarm :ON * Show SMS Alarm condition ( ON/OFF ) and Buzzer Alarm condition ( ON/OFF ). 3 SMS Delay :5S Regular SCREEN SMS Period :3M * Show SMS Delay time value and the SMS Period time value. 4 Buzzer Delay :5S Regular SCREEN Buzzer Rep :1M * Show Buzzer Delay time value and the Buzzer repeat time value. 5 Normal Regular SCREEN Detect SW :OFF * Show the system is under Normal or Interrupt condition. * Show the Wireless switch is under ON or OFF condition, 3) RESET Button If push the " RESET button " * ( 4-19, Fig. 1 ), the LCD will lit and going on to count down from 90 seconds back to 0 second, then present the SETUP SCREEN. The " System indicator " ( 4-6, Fig. 1 ) will flash ( per 1 second On, 1 second Off ) if the CPU Circuit working properly. 30

At the beginning, the GSM modem is not connecting the mobile network, the " GSM indicator " ( 4-4, Fig. 1 ) will flash per 0.6 second On and 0.6 second Off. After the GSM modem already connect to the mobile network properly, the " GSM indicator " will flash per 0.075 second On and 3 second Off. Remark : From the mobile to send the SMS command " RESET " will execute the same function exactly as push " RESET button " ( 4-19, Fig. 1 ) 3)Relay Output terminals Warning! For the long term operation, for each " Relay Output Terminal " ( 4-22, Fig. 3 ), please do not connect the max. load over 1 ACA ( 250 ACV ). 31

11. TROUBLE SHOOTING 1)When the mobile send the SMS command to system, mobile get the following SMS conformation : WRONG INSTRUCTION! Corrective action : SMS command entry error ( typing error )? Repeat the command exactly as the specification, refer page 21, page 22. 2)When the mobile send the SMS command to system, the system do not execute the action as the desired function. Corrective action : The system may possible not key in the right mobile telephone number? Please check and key in telephone no. again. 3)Power on the system, but the " GSM indicator " is not finished. Corrective action : May the GSM modem is not triggered. Power off, wait at least 10 seconds, then power on. The duration between power Off and power On, should wait at least 10 seconds. 32

4)The system do not send the alarm SMS out as the desired. Corrective action : Check if the system set the alarm function to OFF ( disable )? Setting the ON ( enable ) alarm function again. 5)After power On the system, the GSM modem do not connect to the mobile network ( GSM indicator just flash per 0.6 second On and 0.6 second Off ). Corrective action : Check if you already cancel the PIN code of SIM card? Use your mobile to check the SIM card. If the network signal strength is too weak, please use the optional separate antenna to instead the original antenna ( included ). 6)When the mobile send the SMS command to the system, the mobile do not get any SMS confirmation as desired. Corrective action : May the LCD SCREEN select to SETTING SCREEN. Under normal operation, the LCD display should select to the Regular SCREEN, other wise the system can not accept SMS in or send the SMS out. Refer Page 27. 33

12. OPTIONAL ACCESSORIES Wireless WB-122 can plug in main system ( 4-20, Buzzer Fig. 3 ). User can hide the main system ( BS120 ) and only present the Model : WB-122 in the obviously place, then the WB-122 thief will not find the main system easily. Wireless WR-123 can plug in main system ( 4-21, Relay If user intend to control the electrical appliance, it is not necessary use the Model : wires to connect to the main system. WR-123 34

ANNEX Due to intend to let the user to operate the BS120 more friendly, this unit increase the following new function. When the LCD already present any Regular SCREEN ( not the SET SCREEN ), if push the Button 0 " then the LCD will count down from 90 seconds back to 0 second. During this counting down period, the main system will halt, the ON/OFF of wireless switch will be not to effect the system, however GSM module will be still working properly ( GSM indicator will flash per 0.075 second On and 3 second Off ). Remark : @The different between press " Button 0 " and the " RESET Button " are if press the " RESET Button " will reset the system then restart again. However press the " Button 0 ", just halt the system only. @The main application of " Button 0 " are that when the system is ready, if the user intend to leave home, it can just push the " Button 0 " instead of press the RESET Button ", this new operation procedure will be more convenient for the user. 35