MODEL: M5DY SEN TRONIC AG CURRENT LOOP SUPPLY. [2] POWER INPUT AC Power M: V AC (Operational voltage range V, Hz)

Similar documents
MODEL: R2K-1 SEN TRONIC AG. R2K Series

MODEL: M1EXM. OUTPUT Field-selectable DC Output Current output: 0-20 ma DC Voltage output: V DC Voltage output: V DC

MODEL: M1EXV. OUTPUT Field-selectable DC Output Current output: 0-20 ma DC Voltage output: V DC Voltage output: V DC

MODEL: 47LYV. Digital Panel Meters 47 Series

MODEL: M2EXM. Super-mini Signal Conditioners with Display Mini-M M2E Series

R1M-GH BEFORE USE... POINTS OF CAUTION INSTRUCTION MANUAL PC RECORDER MODEL. (thermocouple or DC input, 16 points)

R1M-GH BEFORE USE... POINTS OF CAUTION INSTRUCTION MANUAL PC RECORDER MODEL. (thermocouple or DC input, 16 points)

MODEL: 43AL1. Digital Panel Meters 43 Series

MODEL: 40DN. Digital Panel Meters 40 Series

MODEL: R1M-D1. PC Recorders R1M Series. SPECIFICATIONS OF OPTION: Q COATING (For the detail, refer to M-System's web site.)

MODEL: R1M-A1. PC Recorders R1M Series. SPECIFICATIONS OF OPTION: Q COATING (For the detail, refer to M-System's web site.)

MODEL: MD7ST. [3] LOOP DISCONNECT FUSE 0: Without 1: With (CENELEC/ATEX approval Not selectable)

MODEL: MD7TC. Lightning Surge Protectors for Electronics Equipment M-RESTER

MODEL: MDCAT. Lightning Surge Protectors for Electronics Equipment M-RESTER

MODEL: MDCAT. Lightning Surge Protectors for Electronics Equipment M-RESTER

MODEL: R1M-GH. PC Recorders R1M Series

MODEL: SC100. Single Loop Controller Series. MULTI-FUNCTION PID CONTROLLER (color LCD with touch-panel) MODEL: SC100 [1]0 [2][3]

MODEL: 40DR SEN TRONIC AG. Digital Panel Meters 40 Series

MODEL: R1M-P4. PC Recorders R1M Series. SPECIFICATIONS OF OPTION: Q COATING (For the detail, refer to M-System's web site.)

MODEL: GR8-EM. Communication Adaptor GR8 Series

DLS-E2 TELEMETERING UNIT BEFORE USE... POINTS OF CAUTION INSTRUCTION MANUAL MODEL. (16 contact inputs & 16 open collector outputs)

MODEL: 43DV2. Digital Panel Meters 43 Series

NPN / PNP DISCRETE INPUT & NPN TRANSISTOR OUTPUT MODULE, 16 points each

NPN/PNP DISCRETE HIGH SPEED INPUT & NPN TRANSISTOR OUTPUT MODULE

MODEL: R3-NE1. Remote I/O R3 Series. ETHERNET INTERFACE MODULE (Modbus/TCP) 27.5 (1.08)

INSTRUCTION MANUAL 2-WIRE UNIVERSAL TEMPERATURE TRANSMITTER

R7D-RR8 BEFORE USE... POINTS OF CAUTION. INSTRUCTION MANUAL REMOTE CONTROL RELAY CONTROL MODULE, 8 points MODEL. (DeviceNet)

MODEL: 40DV SEN TRONIC AG. Digital Panel Meters 40 Series

BEFORE USE... POINTS OF CAUTION. INSTRUCTION MANUAL PNP TRANSISTOR OUTPUT MODULE, 16 points (MECHATROLINK-I / -II, short circuit protection)

MODEL: 6DV-B. [2] TERMINAL BLOCK 0: None (Euro terminal block at the rear of indicator module)

MODEL: 6DV-B. [2] TERMINAL BLOCK 0: None (Euro terminal block at the rear of indicator module)

MODEL: W2XR SEN TRONIC AG. Mini-MW Series

MODEL: WL40EW2F. Wireless I/O WL40F Series

CONTENTS 1. BEFORE USE GENERAL DESCRIPTION POINTS OF CAUTION HARDWARE SPECIFICATIONS... 4

Table of Contents. Introduction... 2 Description...2 Specifications...3 Installation.. 5 Calibration.. 6 General Maintenance...7

R6-NC1 BEFORE USE... POINTS OF CAUTION. INSTRUCTION MANUAL CC-Link INTERFACE MODULE MODEL. (CC-Link Ver.1.10; for 16-point analog signals)

R3-GE1 BEFORE USE... INSTALLATION POINTS OF CAUTION INSTRUCTION MANUAL ETHERNET INTERFACE MODULE MODEL. (Modbus/TCP)

Isolated Process Current Input 7B32 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

ECT Signal Isolator/Converter

Isolated, Voltage or Current Input 7B30 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

MODEL: R3-NL1. RELATED PRODUCTS XIF File (Device Interface File) XIF file is used to define a LonWorks device when programmed on LonMaker.

Isolated Voltage Input 7B31 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

Voltage Current Front-mounting bracket

MODEL: R3-NL2. RELATED PRODUCTS XIF File (Device Interface File) XIF file is used to define a LonWorks device when programmed on LonMaker.

Page Housing Plastic Metal Mounting DIN Rail or surface mount Panel or bracket mount Wattage Range 10W to 240W 7.5W to 240W 10W to 300W

DAL4 REPEATER MODEL. (SIN-NET, M-Bus use) MODEL & SUFFIX CODE SELECTION DAL4 TRANSMISSION ORDERING INFORMATION RELATED PRODUCTS GENERAL SPECIFICATIONS

Isolated Process Current Input with Loop Power 7B35

9000C INDEX APPLICATION EXAMPLE 1 SPECIFICATION 2 SAFETY AND WARNING... 3 CONNECTION 3 INSTALLATION.. 4 ORDERING CODE 4 TROUBLE SHOOTING 4

R6-NE1 BEFORE USE... POINTS OF CAUTION INSTRUCTION MANUAL ETHERNET INTERFACE MODULE MODEL. (Modbus/TCP, for 32-point analog signals)

Compact Inductive Proximity Sensor

Energy Management Modular DC Energy analyzer Type VMU-E and VMU-X

R1M-J3 BEFORE USE... POINTS OF CAUTION INSTRUCTION MANUAL RTD & POTENTIOMETER INPUT MODULE MODEL. (8 points)

DIN Rail. user manual Models , & INT /503556/ UM

Efficiency (typ.) Load VDC VDC ma ma(typ.) ma(typ.) μf %

DPST-NO None 2 channels Auto-reset Inverse (+/-) 24 VAC/VDC 4 G9SB-2002-A 1 channel or 2

R1M-GH THERMOCOUPLE & DC INPUT MODULE MODEL. Remote I/O R1M Series. (16 points)

Suitable for detecting transparent films or transparent bottles

Switching Power Supply S82J. Ordering Information. Open-Frame, Covered-Frame, or Enclosed-Frame Type with Capacity Up to 600 W

MODEL AAMA - UNIVERSAL SIGNAL CONDITIONING MODULE

Wide Bandwidth Strain Gage Input 3B18 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

Millenium II +: general characteristics

Conforms to VDE0435/2021 C/250, VDE0110, VDE0106/P100 Conforms to EN , pren

Switch Mode Power Supply S8VT 120/240/480/960 W Models

RE22R1QMQ star-delta timing relay - 230VAC/440VAC - 1 C/O

R3-NL1 LONWORKS INTERFACE MODULE BEFORE USE... INSTALLATION POINTS OF CAUTION INSTRUCTION MANUAL. R3-nL1 MODEL

MODEL: R3-NFL1. SPECIFICATIONS OF OPTION: Q COATING (For the detail, refer to M-System's web site.) Remote I/O R3 Series

Functional configuration Rated input voltage Power ratings Output voltage Output current Part number Non-PFC

Power Supplies. PS5R Standard Series Switching Power Supplies. Part Numbers. Part Number

Energy Management Modular DC Energy analyzer Type VIM-E and VIM-X

Safety Relay Unit (I/O Unit Type)

S8VE (60/90/120/180/240-W Models)

Ordering Information. Three-phase Input Switch Mode Power Supply S8VT S8VT. Model Number Legend

02/11/2015

PC RELAY TERMINAL/ PC TERMINAL

OPERATOR S MANUAL 9000U ISOLATOR

Isolated Linearized RTD Input 5B34 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

MPV1060RI4. Ultra Wide Input, Compact Industrial Grade, PV Power DC/DC Con vert ers. Key Features:

GX SERIES. Cylindrical Compact Inductive Proximity Sensor Amplifier Built-in. Robust enclosure and flexible cable types are also available

MINI MCR-SL-UI-2I. Configurable signal duplicator. Data sheet. 1 Description

Isolated Current Output 5B39 FEATURES APPLICATIONS PRODUCT OVERVIEW

VM-11 SERIES MODEL VM-11B ACCELERATION INPUT VIBRATION SIGNAL CONDITIONER INSTRUCTION MANUAL. MANUAL No E1.8. Revised in Mar.

Switching Power Supply

LOGIC CONTROLLER INSTALLATION MANUAL NTR 756 B /E

H3CA-8H-AC/100/110/120

Thread length (overall length) material

MINI MCR-SL-PT100-UI-200

Isolated, Voltage or Current Input 7B41 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

H3CR-F H3CR-F8 H3CR-F-300 H3CR-F8-300

PHOENIX CONTACT Features

DIO-0808RN-USB. N Series for USB Isolated Digital I/O Unit(8ch Relay Output, 8ch DI) DIO-0808RN-USB 1. Ver.1.02

R3-NL2 INSTALLATION BEFORE USE... POINTS OF CAUTION INSTRUCTION MANUAL LONWORKS INTERFACE MODULE MODEL. (I/O 56 points)

Installation Instructions

Solid-state Timer H3YN

DINALOG A 144 x 36 A1400 Light-Strip Indicator

HITACHI. EH-150 series PLC EH-RTD8 Resistance Temperature Detective input module Instruction manual. Safety precautions

Isolated Wideband Voltage Input 3B40 / 3B41 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

Thread length. 27 (40) mm. 27 (44) mm. 27 (40) mm. 34 (50) mm. 34 (49) mm. 39 (60) mm. 39 (54) mm. 44 (65) mm. 44 (59) mm

PWR. Power Module Slots

Operating Instructions VEGAMET 381

Cylindrical Compact Inductive Proximity Sensor Amplifier Built-in. panasonic.net/id/pidsx/global

Transcription:

Super-mini Terminal Block Signal Conditioners M5-UNIT CURRENT LOOP SUPPLY Functions & Features Powering a 0 ma DC current loop Applicable to smart transmitters Isolation between the input and output Fast response type available High-density mounting Power LED CE marking for V power 5 (.98) 97 (.8) (.6) mm (inch) 0: Specify voltage (See OUTPUT SPECIFICATIONS) 0: Specify voltage (See OUTPUT SPECIFICATIONS) [] POWER INPUT AC Power M: 85 6 V AC (Operational voltage range 85 6 V, 7 66 Hz) DC Power R: V DC (Operational voltage range V ±0 %, ripple 0 %p-p max.) [] OPTIONS RESPONSE TIME (0 90 %) blank: Standard ( 0.5 sec.) /K: Fast Response (Approx. 5 msec.) OTHER OPTIONS blank: none /Q: Option other than the above (specify the specification) M5DY- - ORDERING INFORMATION Specify a code from below for each [] through []. Code number: M5DY-[]-[][] (e.g. M5DY-A-R/K/Q) Specify variables. Special output range (For codes Z & 0) Specify the specification for option code /Q (e.g. /C0 /V0) INPUT Current 0 ma DC (Input resistance 9.5 Ω) [] OUTPUT Current A: 0 ma DC (Load resistance 550 Ω max.) D: 0 0 ma DC (Load resistance 550 Ω max.) Z: Specify current (See OUTPUT SPECIFICATIONS) Voltage : 0 0 mv DC (Load resistance 00 kω min.) : 0 00 mv DC (Load resistance 00 kω min.) : 0 V DC (Load resistance 00 Ω min.) : 0 0 V DC (Load resistance 000 Ω min.) 5: 0 5 V DC (Load resistance 500 Ω min.) 6: 5 V DC (Load resistance 500 Ω min.) OPTION SPECIFICATIONS OF /Q (multiple selections) COATING (For the detail, refer to M-system's web site.) /C0: Silicone coating /C0: Polyurethane coating /C0: Rubber coating ADJUSTMENT /V0: Multi-turn fine adjuster GENERAL SPECIFICATIONS Construction: Terminal block Connection: M.5 screw terminals (torque 0.8 N m) Screw terminal: Nickel-plated steel Housing material: Flame-resistant resin (black) Isolation: Input to output to power Zero adjustment: - to % (front) Span adjustment: 98 to 0 % (front) Power LED: Green light turns on when the power is supplied. SUPPLY OUTPUT (across the terminals ) Output voltage: 8 V DC with no load 8 V DC min. at 0 ma Current rating: ma DC max. Shortcircuit Protection Current limited: 0 ma max. Protected time duration: No limit Tel. (0)56 8 8 Fax (0)56 0

INPUT SPECIFICATIONS DC Current: Input resistor incorporated OUTPUT SPECIFICATIONS DC Current: 0 0 ma DC Minimum span: ma Offset: Max..5 times span Load resistance: Output drive V max. DC Voltage Output code 0 (CE) Voltage range: 0 0 V DC Minimum span: V Offset: Max..5 times span Load resistance: Output drive 0 ma max.; at V Output code 0 (Not CE) Voltage range: 0 V DC Minimum span: 0 mv Offset: Max..5 times span Load resistance: Min. 00 kω INSTALLATION Power Consumption AC Power input: Approx. VA DC Power input: Approx. W Operating temperature: -5 to 55 C ( to F) Operating humidity: 0 to 90 %RH (non-condensing) Mounting: DIN rail Weight: 80 g (.8 oz) PERFORMANCE in percentage of span Acuuracy: ±0. % Temp. coefficient: ±0.05 %/ C (±0.008 %/ F) Line voltage effect: ±0. % over voltage range Insulation resistance: 00 MΩ with 500 V DC Dielectric strength (input to output to power to ground) DC powered: 000 V AC @ minute AC powered: 500 V AC @ minute STANDARDS & APPROVALS CE conformity: EMC Directive (00/08/EC) EN 6000-6- (EMI) EN 6000-6- (EMS) Tel. (0)56 8 8 Fax (0)56 0

FRONT VIEW Power LED Span Adj. Zero Adj. 5 6 7 8 DIMENSIONS unit: mm (inch) 7. (.9) 8M.5 SCREW DIN RAIL 5mm wide 9 (.70) 5. (.9) 5 6 7 8 (.) 5 (.98) (.6) [. (.)] When mounting, no extra space is needed between units. SCHEMATIC CIRCUITRY & CONNECTION DIAGRAM -WIRE TRANSMITTER MONITOR V ( 5V DC) 9.5Ω Shortcircuit Protection Z S Low Drift Amplifier V DC Supply Isolation Output Driver POWER LED 5 6 OUTPUT 7 U() 8 V() POWER When Used as DC Supply When Used as Isolator -WIRE XMTR 9.5Ω INPUT 9.5Ω Tel. (0)56 8 8 Fax (0)56 0

Specifications are subject to change without notice. Tel. (0)56 8 8 Fax (0)56 0

INSTRUCTION MANUAL CURRENT LOOP SUPPLY MODEL M5DY M5DY BEFORE USE... Thank you for choosing M-System. Before use, please check contents of the package you received as outlined below. If you have any problems or questions with the product, please contact M-System s Sales Office or representatives. PACKAGE INCLUDES: Signal conditioner... () MODEL NO. Confirm Model No. marking on the product to be exactly what you ordered. INSTRUCTION MANUAL This manual describes necessary points of caution when you use this product, including installation, connection and basic maintenance procedures. POINTS OF CAUTION CONFORMITY WITH EC DIRECTIVES The equipment must be mounted inside a panel. Insert a noise filter for the power source, input and output connected to the unit. COSEL Noise Filter Model NAC-06-7, TDK Noise Filter Model ZCAT 05-0 or equivalent is recommended. The actual installation environments such as panel configurations, connected devices, connected wires, may affect the protection level of this unit when it is integrated in a panel system. The user may have to review the CE requirements in regard to the whole system and employ additional protective measures to ensure the CE conformity. choose a surge protector with its maximum surge voltage 0V or less between lines. Recommended M-System model: MDP-D. AND... The unit is designed to function as soon as power is supplied, however, a warm up for 0 minutes is required for satisfying complete performance described in the data sheet. COMPONENT IDENTIFICATION Body Spec. Marking INSTALLATION Terminal Cover Power LED Span Adj. Zero Adj. Set the unit so that its DIN rail adapter is at the bottom. MOUNTING THE UNIT ON A DIN RAIL A) Hang the upper hook at the rear side of unit on the DIN rail. B) Push in the lower in keeping pressing the unit to the DIN rail. POWER INPUT RATING & OPERATIONAL RANGE Locate the power input rating marked on the product and confirm its operational range as indicated below: 85 6V AC rating: 85 6V, 7 66 Hz, approx. VA V DC rating: V ±0%, approx. W A DIN Rail GENERAL PRECAUTIONS Before you remove the unit or mount it, turn off the power supply and input signal for safety. ENVIRONMENT Indoor use When heavy dust or metal particles are present in the air, install the unit inside proper housing with sufficient ventilation. Do not install the unit where it is subjected to continuous vibration. Do not subject the unit to physical impact. Environmental temperature must be within -5 to 55 C ( to F) with relative humidity within 0 to 90% RH in order to ensure adequate life span and operation. REMOVING THE UNIT A) Push down the DIN rail adaptor using a minus screwdriver. B) Pull out the lower part of the unit. C) Remove the upper part from the DIN rail. B WIRING Do not install cables (power supply, input and output) close to noise sources (relay drive cable, high frequency line, etc.). Do not bind these cables together with those in which noises are present. Do not install them in the same duct. Install lightning surge protectors for those wires connected to remote locations. For V DC power supply line, C Spring Loaded DIN Rail Adaptor A B EM-76 Rev.6 P. / Tel. (0)56 8 8 Fax (0)56 0

M5DY TERMINAL CONNECTIONS Connect the unit as in the diagram below or refer to the connection diagram on the front of the unit. EXTERNAL DIMENSIONS unit: mm (inch) 7. (.9) 8M.5 SCREW CHECKING ) Terminal wiring: Check that all cables are correctly connected according to the connection diagram. ) Power input voltage: Check voltage across the terminal 7 8 with a multimeter. ) Input: Check that the input signal is within 0 00% of the full-scale. ) Output: Check that the load resistance meets the described specifications. DIN RAIL 5mm wide ADJUSTMENT PROCEDURE 9 (.70) 5. (.9) This unit is calibrated at the factory to meet the ordered specifications, therefore you usually do not need any calibration. For matching the signal to a receiving instrument or in case of regular calibration, adjust the output as explained in the following. (.) 5 6 7 8 5 (.98) (.6) [. (.)] When mounting, no extra space is needed between units. CONNECTION DIAGRAM -WIRE TRANSMITTER MONITOR V ( 5V DC) When Used as DC Supply -WIRE XMTR 5 6 8 7 U() V() OUTPUT POWER When Used as Isolator HOW TO CALIBRATE THE OUTPUT SIGNAL Use a signal source and measuring instruments of sufficient accuracy level. Turn the power supply on and warm up for more than 0 minutes. ) ZERO: Apply 0% input and adjust output to 0%. ) SPAN: Apply 00% input and adjust output to 00%. ) Check ZERO adjustment again with 0% input. ) When ZERO value is changed, repeat the above procedure ) ). MAINTENANCE Regular calibration procedure is explained below: CALIBRATION Warm up the unit for at least 0 minutes. Apply 0%, 5%, 50%, 75% and 00% input signal. Check that the output signal for the respective input signal remains within accuracy described in the data sheet. When the output is out of tolerance, recalibrate the unit according to the ADJUST- MENT PROCEDURE explained earlier. 9.5Ω INPUT 9.5Ω Tel. (0)56 8 8 Fax (0)56 0