Standard-Signal Isolation Amplifiers. VariTrans A 21000

Similar documents
VariTrans A The specialist for ±10 V and ±20 ma. With calibrated range selection and broad-range power supply.

VariTrans B The world s first 3-port standard signal isolator in a 6-mm modular housing.

VariTrans P The Problem The variety of tasks results in a large number of different devices.

High-Voltage Isolation Amplifiers / Shunt Isolators. VariTrans P 42000

Signal Doublers. VariTrans A 20300

WG 20. The WG 20 achieves an extraordinarily. accuracy for hazardous-area. applications.

VariTrans P Standard-Signal Isolators

SensoTrans DMS A 20220

SensoTrans DMS P 32200

Contact protection relay

Alarm Unit DG 3200 Control And Monitor Standard Signals

MINI MCR-SL-UI-2I-NC. Extract from the online catalog. Order No.:

Power Supply HARTING pcon

Extract from the online catalog

MINI MCR-SL-UI-2I(-SP)(-NC)

MINI MCR-SL-UI-2I. Configurable signal duplicator. Data sheet. 1 Description

Process Analysis Systems. Stratos Pro A4 MSPH/MSPH. Chem Energy Pharm Food Water. Connection

MINI MCR-SL-PT100-UI-200

Measuring transducers MI4x0 series Programmable transducers for RTD sensors MI450

Power Supply HARTING pcon

Multi-range pressure and differential pressure transmitter

Transducers for Pt-100/1000, Resistors

PHOENIX CONTACT - 07/2006

Operating instructions. Standstill monitor A / / 2011

MINI MCR-SL-PT100-UI(-SP)(-NC)

MINI MCR-SL-UI-REL(-SP)

The Art of Measuring. Compact. Cost-efficient. Digital. Plug & Measure with the new analyzers for Memosens. MemoRail

Extract from the online catalog

The Art of Measuring. Compact Transmitter with Modbus Interface. MemoRail Modbus

RTU500 series Data Sheet Power Supply CP-E 24/2.5

THERMASGARD TM 65. Immersion screw-in duct temperature measuring transducer, calibratable, with multi-range switching and active output TECHNICAL DATA

RMCN22BD Analog Converter ma - for Zelio Analog

Operating instructions. Switching amplifier DN0210 DN / / 2015

SITOP in the SIMATIC Design

OTB1E0DM9LP I/O distributed module OTB - Ethernet TCP/IP m

RM35LM33MW liquid level control relay RM35-L V AC/DC

RM35LM33MW liquid level control relay RM35-L V AC/DC

OTB1C0DM9LP I/O distributed module OTB - CANopen bus m

Power supply CP-C 24/5.0

MINI MCR-SL-RPS-I-I. Repeater power supply, active. Data sheet. 1 Description

Extract from the online catalog

RM17UAS. Product datasheet Characteristics. voltage control relay RM17-U - range V DC. Main. Complementary. Price* : 70.

The Model 703 offers a wide range of practical features to meet the numerous requirements of everyday measuring tasks.

PHOENIX CONTACT - 06/2007. DANGER OF EXPLOSION! Remove an item only when it is not connected to power or if it is located in the non-explosive area.

SITOP 3-phase 24 V DC, 20 to 40 A

OTB1S0DM9LP I/O distributed module OTB - Modbus non isolated serial link m

Connection of OXY module with oxygen sensor (SE 706, Mettler Toledo InPro 6800, Hamilton Oxyferm) Model used: Stratos Pro A401N OXY/ V AC/DC

VEO. V2PF480Y/277VSY01 Art.Nr.: V2PF480Y/277VSY01P Art.Nr.: TECHNICAL DATA

MINI MCR-SL-PT100-UI. Active resistance thermometer measuring transducer. Data sheet. 1 Description

APU 200 Automatic DATA SHEET Gen-set Controller DATA SHEET

MINI-PS AC/10-15DC/8

Manual Industry Interfaces

PHOENIX CONTACT - 01/2010. Features. DANGER OF EXPLOSION! Only remove equipment when it is disconnected and not in the potentially explosive area.

TM3TM3 module TM3-2 temperature inputs and 1 analog output

Industriefunkuhren. Technical Manual. Signal Converter. for DIN Rail Mounting Series 4800xx-yy ENGLISH

PHOENIX CONTACT - 08/2009. Features. DANGER OF EXPLOSION! Only remove equipment when it is disconnected and not in the potentially explosive area.

QUINT-PS AC/24DC/10

OTB1S0DM9LP I/O distributed module OTB - Modbus non isolated serial link m

DATA SHEET Selectable AC transducer, TAS-331DG

TRIO-PS/1AC/24DC/20. Extract from the online catalog. Order No.:

Power consumption In operation At rest For wire sizing. Torque Inhibiting torque. 150 s / C Sound power level Motor

Ultra-small U-shaped Micro Photoelectric Sensor. Extremely small size enables space saving!! 12 mm in

QUINT-PS/1AC/24DC/10. Extract from the online catalog. Order No.:

PM-24 SERIES. Ultra-small U-shaped Micro Photoelectric Sensor. Extremely small size enables space saving!! ( ) Equipped with two independent outputs

GFK-2415A March Type of sensor connection

STEP-PS/1AC/24DC/1.75

DEIF A/S. TAS-331DG Selectable AC transducer G (UK) Installation and start up instructions. Watt or var transducer

Operating Instructions Differential Pressure Transducer PS27

TM3AI4 module TM3-4 analog inputs

Faults on the system Proximity switch connection technology:

Intrinsically Safe Barriers

703 Laboratory Conductivity Meter

OTB1C0DM9LP I/O distributed module OTB - CANopen bus m

JUMO ecotrans ph 03 Microprocessor transmitter/ switching device for ph/redox voltage and temperature

OTB1C0DM9LP. Main , length of segment <= 185 m , length of segment <= 160 m. 3.4 kohm for I8...I kohm I0...I1 5.7 kohm I6...

Power supply CP-E 24/0.75 Primary switch mode power supply

OTB1E0DM9LP I/O distributed module OTB - Ethernet TCP/IP m

TM5C12D6T6L compact I/O expansion block TM5-24 I/0-12 DI - 6 DO transistor - 4 AI - 2 AO

CONVERTER OF RS-232/RS-485 INTERFACES PD51 TYPE USER S MANUAL

Indicators. Hazardous-Area Indicators. 830 X R Loop-Powered 16 Process Indicator. 830 X S1 Loop-Powered 16 Process Indicator

MODEL 9250 Preliminary data sheet

RM35UB3. Product data sheet Characteristics. voltage control relay RM35-U - range V AC. Main. Complementary

QUINT-PS/ 1AC/24DC/ 5

Data sheet ACT20P ACT20P-CMT-10-AO-RC-S. Phone: Fax: Web: - [!

XPSMF35. Product data sheet Characteristics. Preventa safety PLC compact - Profibus DP protocol. Main. Complementary. Safety module name

Voltage Transducer UMT516 / MT516

OTB1E0DM9LP I/O distributed module OTB - Ethernet TCP/IP m

SR2A201BD compact smart relay Zelio Logic - 20 I O - 24 V DC - no clock - display

itemp TMT180 Technical information

Power supply CP-E 24/10.0 Primary switch mode power supply

QUINT-BUFFER/24DC/24DC/40

Assembly. Front view. LED yellow/red: Status output Ι/ Fault signal Function. Switch Power Rail

RM35TF. Main. Product or component type. Product specific application. Relay monitored parameters 250 V AC 5 A AC

Operating instructions. Speed monitor D / / 2014

Power supply CP-E 48/1.25 Primary switch mode power supply

RM17UB3. Product data sheet Characteristics. voltage control relay RM17-U - range V AC. Main. Complementary

EM2020 Selectable AC transducer A (UK)

ABL1REM24100 regulated SMPS - single phase V input - 24 V output W

Inductive proximity sensors IQ 40 series, sensing range 15 / 20 mm DC 3-wire, plastic housing

SR2B121BD compact smart relay Zelio Logic - 12 I O - 24 V DC - clock - display

Transcription:

Standard-Signal Isolation Amplifiers The first standard-signal isolation amplifier with protective separation and broad-range power supply in the 6-mm class. The Task Isolation and conversion of 0... 20 ma, 4... 20 ma as well as 0... 10 V standard signals with high demands to measurement accuracy. At the same time, best possible protection of personnel and equipment must be guaranteed. The Problem The standards governing the erection of installations demand protective separation according to EN 61140. The tightly dimensioned installation space on the mounting rail must be optimally used. Procurement logistics and stockkeeping demand a universal product which covers all common signal combinations and which can be used around the world with the broad-range power supply. The Solution In spite of its just 6 mm wide modular housing, the new meets the requirements of EN 61140 regarding protective separation up to a working voltage of 300 V. The test voltage is 2.5 kv AC. Very small leakage capacitances also ensure that high transient common-mode interferences can be isolated reliably and don't lead to system malfunctions. Standardization and flexible signal conversion are optimally implemented by the calibrated range selection on-site calibration becomes superfluous. The Housing The just 6 mm wide modular housing allows high component density in the enclosure. In order to reduce the wiring requirements, power can be provided via the mounting rail bus connector from a central power supply. The Advantages Knick has achieved a significant increase in reliability and service life through the development of isolation amplifiers with extremely low power consumption and low self-heating. This leads to a significant increase in the reliability and service life of the electronic components for example, the MTBF (Mean Time Between Failures) of the new isolation amplifier is 280 years. Thanks to the VariPower power supply for all common supply voltages from 24 to 110 V DC (+/ 25 %) and 110 to 230 V AC (+/ 10 %), the devices can be used internationally with virtually all supply voltages. Isolation amplifiers are mainly used for DC current signals, but the correct transmission of fast signal changes cannot be dispensed with. Excellent large-signal characteristics guarantee a correct run into the overrange limit. Dead times, hysteresis, signal reversal or latch-up effects are prevented an indispensable features for further processing in the PLC. 68

For up-to-date information, please visit www.knick.de Isolation Amplifiers Transmitters Indicators Process Analytics Portable Meters Laboratory Meters Sensors Fittings The Facts Broad-range power supply 24 to 110 V DC (+/ 25 %) and 110 to 230 V AC (+/ 10 %) Standard-conformant protection of personnel and equipment Protective separation according to EN 61140 3-port isolation Prevention of incorrect measurements caused by potential differences Best price-performance ratio High precision and isolation 2.5 kv AC test voltage Easy installation DIN rail bus connectors allow for easy and extremely cost efficient connection of the power supply to several or other Knick products in 6-mm housings. Cost savings through smaller enclosures More channels per meter top hat rail thanks to space-saving 6-mm housing and closely packed mounting Long service life Extremely low failure rate (MTBF of 280 years) due to reduced self-heating High accuracy and temperature stability Gain error 0.2 % meas. val. and temperature coefficient 0.01 %/K Calibrated range selection without complicated adjustments Simple configuration DIL switches accessible from outside Choice of adjustable or fixedrange device versions International use UL approvals for USA and Canada 5-year warranty Warranty 5 years! Warranty Defects occurring within 5 years from delivery date shall be remedied free of charge at our plant (carriage and insurance paid by sender). 69

Standard-Signal Isolation Amplifiers Product Line Devices Input Output Order No. P0 with calibrated switching of input and output A 21000 P0/ P0 with fixed settings A 21016 P0/ A 21017 P0/ A 21018 P0/ A 21026 P0/ A 21016 P0/ A 21028 P0/ A 21036 P0/ A 21037 P0/ A 21038 P0/ Power supply 24 V DC via screw terminals or DIN rail bus connector Broad-range power supply 24 V 110 V DC, 110 230 V AC only via screw terminals 00 01 Accessories Order No. ZU 0628 DIN-rail bus connector IsoPower A 20900 Power supply bridging for two isolators, resp., A 21000 P0 Power supply 24 V DC, 1 A A20900 H4 power supply ZU 0628 A 20900 H4 ZU 0678 DIN rail bus connector Tapping of supply voltage, routing to DIN rail bus connector ZU 0628 ZU 0678 ZU 0677 power terminal block For connecting the supply voltage to the ZU 0628 DIN rail bus connector ZU 0677 Specifications Input data Inputs switchable (default setting ) Input resistance Current input: voltage drop < 0.1 V at 20 ma Voltage input: approx. 100 kohms Overload capacity Current input: < 100 ma Voltage input: voltage limited to 30 V by suppressor diode, max. permitted continuous current: 3 ma 70

For up-to-date information, please visit www.knick.de Isolation Amplifiers Transmitters Indicators Process Analytics Portable Meters Laboratory Meters Sensors Fittings Specifications (continued) Output data Outputs switchable (default setting ) Load With output current: 10 V ( 500 ohms at 20 ma) With output voltage: 1 ma ( 10 kohms at 10 V) Offset Residual ripple < 20 µa or < 10 mv < 10 mv rms Transmission behavior Transmission error < 0.2 % of the measured value for direct current transmission 1:1 < 0.3 % of the measured value for voltage input and/or voltage output Additional error with live-zero operation 20 µa or 10 mv Temperature coefficient Cutoff frequency 0.01 %/K full scale (reference temp. 23 C) Average TC in specified operating temperature range 0 +55 C 100 Hz, 3 db Power supply Power supply A 210XX P0/01: 24 V 110 V DC (±25 %), approx. 1.0 W 110 V 230 V AC (±10 %), approx. 2.0 VA A 210XX P0/00: 24 V DC (±25 %), approx. 0.65 W The power supply can be routed from one device to another via DIN rail bus connectors. Broad-range power supply, 24 110 V DC, 110 230 V AC, without DIN rail bus connector Power supply 24 V DC, screw terminals or DIN rail bus connector Isolation Galvanic isolation Test voltage Working voltage (basic insulation) Protection against electric shock 3-port isolation between input, output and power supply 2.5 kv AC, 50 Hz Up to 300 V AC/DC with overvoltage category II and pollution degree 2 between input and output/power supply Protective separation according to EN 61140 through reinforced insulation according to EN 61010 part 1, up to 300 V at overvoltage category II and pollution degree 2 between input and output/ power supply. For applications with high working voltages, ensure there is sufficient spacing or isolation from neighboring devices and protection against electric shocks. 71

Standard-Signal Isolation Amplifiers Specifications (continued) Standards and approvals EMC Product family standard: EN 61326 Emitted interference: Class B Immunity to interference: Industry Slight deviations are possible during interference. Approvals (pending) culus Listed, Standard: UL 61010-1 and CAN/CSA C22.2 No. 61010-1 Further data MTBF Approx. 280 years Mean Time Between Failures MTBF according to EN 61709 (SN 29500) Requirements: stationary operation in well-kept rooms, average ambient temperature 40 ºC, no ventilation, continuous operation Ambient temperature during operation: 0 +55 C during storage: 40 +85 ºC Design Modular housing with screw terminals, 6.2 mm wide See dimension drawings for further measurements Ingress protection IP 20 Mounting For 35-mm top-hat rail (EN 60715) Weight Approx. 50 g Block Diagram + Input 0/ Z 30 Z 30 + Output 0/ Broad-range power supply 24 to 110 V DC / 110 to 230 V AC 72

For up-to-date information, please visit www.knick.de Isolation Amplifiers Transmitters Indicators Process Analytics Portable Meters Laboratory Meters Sensors Fittings Typical Application FLOW PO Sensor with integrated transducer 0(4) 20 ma Power supply Controller PLC Dimension Drawings and Terminal Assignments 9 93 1 Input + 2 Input 5 Output + 6 Output 7 Power supply 8 Power supply 9 DIP switch S2 10 DIP switch S1 10 6.2 101 All dimensions in mm 73