60W Power over Ethernet Waterproof Adapter PoE IEEE BT Single Port Injector for Outdoor Application

Similar documents
33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application

Installation Manual for D1800 Series High Power PoE Midspan Power Supply

INJ-24A Series Quick Installation Guide

Installation Job Aid for Ethernet Routing Switch 3600 Series

MC 11 EB-2 Power supply cabinet with external bus, AC version

Chameleon Stand-alone

6 Port Unmanaged Industrial Gigabit Ethernet Switch w/ 4 PoE+ Ports and Voltage Regulation - DIN Rail / Wall-Mountable

Installation Job Aid for VSP 4850GTS

Installation Job Aid for VSP 4450GTX-HT- PWR+

BreezeMAX Wi² and BreezeACCESS Wi² Quick Installation Guide

The INJ-102GT-24V PoE Injector is an advanced IEEE802.3at compliant device with intelligent detection that provided

10W Medical Grade Adapter with Interchangeable Plugs*

Arecont Vision MegaView TM v1x Installation Manual

TRC-190 User s Manual

Hypercable injecteur HPOE - Industrial IEEE 802.3at Gigabit PoE Injector. User Manual. v.1.0 Jun Mail :

Industrial 2-port Gigabit High Power Plus PoE++ Injector, 24VDC Input

CC COMPACT DIP SWITCH

See instructions to download and install the latest version of LinkBoxLON and the user's manual at

InView Marquee Message Display

Mid-span 802.3af PoE Injector. Installation Guide KPOE-100

LNP-800AGH-24 Series. Features INTRODUCTION DIMENSIONS

TRC-190 User s Manual

Voltage Current Front-mounting bracket

Lantech. IPES /100TX with 4 PoE Injectors 24~48VDC Industrial Switch. User Manual

QUALITY POWER SOLUTIONS BACKED UP BY REAL-WORLD ENGINEERING EXPERIENCE

Rhino Redundancy Module PSM24-REM360S. Operating Instructions

CONTROL MICROSYSTEMS and 5402 Digital I/O Module. Hardware Manual

Rhino PSM Power Supplies. Operating Instructions

Cisco CRS 3-Phase AC Power Distribution Unit Installation Guide 2. Cisco CRS 3-Phase AC Power Distribution Unit 2

Rhino Buffer Module PSM24-BFM600S. Operating Instructions

POE084824B. PoE 54V/8x0,3A/4x7Ah PoE buffer power supply for up to 8 IP camera. v.1.1 EN* Edition: 7 from

Nokeval. FD100 series. User Manual

Junos WebApp Secure 5.0 Hardware Guide

TSP-BCM48, TSP-BCM48A. Operating Instruction Manual. Page 1 of 13

applications. The TINJ-101-M12 PoE Injector is an advanced IEEE802.3at compliant device with Intelligent Detection that

ZC-OH5 TAMPER-RESISTANT INDOOR/OUTDOOR HOUSING INSTRUCTION MANUAL FOR USE WITH GANZ ZC-D5000 SERIES MINIDOME CAMERAS

Outdoor PTZ. Mounting on the Ceiling Using Pendant Mount. Installation Guide. For Models: I93, I94, I95, I96, KCM /12/03

Installing the Camera

Installation Note for the Cisco ME 3800X and ME 3600X Switch Power Supply and Fan Modules

Conveyor Belt Alignment Switches from IDEM

TraceTek Leak Detection Master Module Installation Instructions TOOLS REQUIRED STORAGE

MINI-PS AC/10-15DC/8

Weathersafe Vision. Installation & Operating Instructions

COMPACT LED DRIVERS. PrimeLine DALI dimmable & Selectable Current (Dip Switch) PrimeLine DALI DIMMABLE & SELECTABLE CURRENT (DIP SWITCH)

REDUNDANCY MODULE TSP-REM360 AND TSP-REM600

PowerLogic High Density Metering System 1-Meter Enclosure

Specification For 90 Watts Adapter Power Supply Model No: ADB002 Customer ID: 000G Revision: 4.0

COMPACT LED CONVERTERS 48 V

LINEAR LED DRIVERS. EasyLine Simple Fix. EasyLine SIMPLE FIX , , , , ,

AE-237. Outdoor Enclosure. Installation Guide. Rev IP Sur veillance. Ordering part no.: G AE-237_V01. Document part no.

MVAD040 Series 40W 2" x 4" AC-DC Power Supply Converter

Waterproof Electrical Junction Box Kits Technical Data Sheet

Replacing the Power Supply

XPSMF35. Product data sheet Characteristics. Preventa safety PLC compact - Profibus DP protocol. Main. Complementary. Safety module name

Industrial Power Supplies

COMPACT LED DRIVERS. EasyLine Simple Fix. EasyLine SIMPLE FIX , , , , , , , , ,

InnoMedia Business VoIP ATA Models

Installation Guide V290 (Color) This guide provides basic information for Unitronics LCD color touchscreen models V C30B and V T40B.

COMPACT LED DRIVERS. ComfortLine Residential. ComfortLine RESIDENTIAL , , ,

POWERSOLVE ELECTRONICS LTD PSL400-XX series Conduction Cooled Power Supply Engineering Specification

Output Voltage* (nom.)(adjustable)

Arecont Vision MegaView TM v1 Installation Manual

MAJOR VA Power Inverter

Safety Standards. Model Number:

Safety switches for hinged doors

RMB Peripheral Units Installation Guide

300 WATT, PFC, OPEN FRAME POWER SUPPLIES TABLE 1. OUTPUT RATINGS AND SPECIFICATIONS, RMW 300W SERIES

5401 and 5402 Digital I/O Modules

DIMENSION/WEIGHT kpa. 0 to 20 m / 0 to 60 ft 0 to 2 bar / 0 to 29 psi. 0 to 50 m / 0 to 160 ft 0 to 5 bar / 0 to 72.5 psi

See instructions to download and install the latest version of LinkBoxMB and the user's manual at

Installation Guide. QBox-V6. Standalone/Spare V6 SDI QBox. Standalone/Spare V6 SDI QBox. Part No. A

Output Current Input Current Max. capacitive Load

3-Port Ethernet over Fiber PoE+ Hardened Switches Installation Guide

Page Housing Plastic Metal Mounting DIN Rail or surface mount Panel or bracket mount Wattage Range 10W to 240W 7.5W to 240W 10W to 300W

Obtaining Documentation and Submitting a Service Request, page xvii Safety Warnings, page xvii Safety Guidelines, page xx

ColourChaser Touch. Installation Guide

LINEAR LED DRIVERS. ComfortLine Industry Selectable Current (LEDset) ComfortLine INDUSTRY SELECTABLE CURRENT (LEDset) ,

MODEL SW6000 & SM6100 CENELEC INSTRUCTIONS

Modular 8-Port Mid-span Power over Ethernet Injector

Installing the Cisco AS5400XM Universal Gateway

Installation of the POTS splitter card requires the following steps: Determining the cables you need. Installing the POTS splitter chassis

60 Watt Medical (MWLT)

LINEAR LED DRIVERS. ComfortLine NFC. ComfortLine NFC , , ,

Perle MCR200 Installation Guide

Disclaimer. Note that the Midspan is designed for indoor use only.

MOXA EtherDevice Switch & PoE Splitter

PHOENIX CONTACT - 08/2009. Features. DANGER OF EXPLOSION! Only remove equipment when it is disconnected and not in the potentially explosive area.

See instructions to download and install the latest version of LinkBoxEIB and the user's manual at

These power supplies are ideal for telecom, datacom, industrial equipment and other applications.

SAMSUNG ELECTRO-MECHANICS CO., LTD

4 10/100/1000T Mini-GBIC with 4 IEEE 802.3at High Power PoE Industrial Wide Temperature Switch. User Manual SISTP LRT

Inductive Cylinder Position Sensors

ATS-16 HV USER MANUAL. Automatic Transfer Switch 16A / 230Vac V090318

10/100/1000TxBase-T(X) P.D. input port and two 10/100/1000TxBase-T(X) P.S.E. output ports, the device not only pass on

ICS Entrance Management Sign Installation Guide. Version 1.0

AC-DC POWER SUPPLIES UNIVERSAL INPUT, 65 WATT MEDICAL APPLICATIONS MUI65 SERIES

C-POWER AC AUTOMATIC CONTROL

HV-CS kv Edge Mount Triaxial Jack

DC Outdoor Power Supply/Chargers

Installation and Maintenance

Transcription:

WWW.PHIHONG.COM 60W Power over Ethernet Waterproof Adapter PoE IEEE BT Single Port Injector for Outdoor Application Features Compliant with the IEEE802.3bt Standard Non-Vented Case with Mounting Bracket Diagnostic LEDs Full Protection OCP, OVP Gigabit Compatible 1 Year Warranty IP67 Rating (Waterproof) Optional Cable Glands for Waterproof -40 C to +60 C Temperature Range Operation (sold separately) Up to 90W w/derated Temperature. Applications Outdoor Security Cameras Outdoor Emergency Lighting Outdoor Wireless Access Points Safety Approvals cul/ul CE Mechanical Characteristics (without Mounting Bracket) Length: 252.1mm (9.93in) Height: 78mm (3.07in) Width: 176mm (6.93in) Weight: 1.7Kg (3.75lb) Mechanical Characteristics (with Mounting Bracket) Length: 300mm (11.81in) Height: 82mm (3.23) Width: 184mm (7.24in) Weight: 2.83kg (6.24lb) Output Specifications DC Output Load Regulation Model Voltage Min. Max. Line Load POE62U-1BT 1 56V 0A 1.07A 54-57Vdc under all conditions Notes: (1) Consult factory for availability Phihong is not responsible for any error, and reserves the right to make changes without notice. Please visit our website at www.phihong.com for the most up-to-date specifications and contact information. Revision 5/29/2018

POE62U Characteristics INPUT: AC Input Voltage Range 90 to 264VAC AC Input Voltage Rating 100 to 240VAC AC Input Current 2.5A (RMS) and 90VAC at maximum load 1.2A (RMS) and 240VAC at maximum load AC Input Frequency 47 to 63Hz Leakage Current 3.5mA for 254VAC, 50Hz Max Inrush Current 50A for 115VAC at maximum load 75A for 230VAC at maximum load OUTPUT: Total Output Power 60W over 4 pairs at 60C 75W over 4 pairs at 50C 90W over 4 pairs at 40C Ripple and Regulation 300mV maximum Efficiency 70% (typical) at maximum load, and 120VAC 60Hz ENVIRONMENTAL: Temperature Operation -40 to +60 C Non-operation -40 to +85 C Humidity Operation 5 to 90% EMI Complies with FCC Class B Complies with EN55032 Class B WWW.PHIHONG.COM Isolation Test Primary to Secondary: 4242 VDC for 1 minute, 10mA Primary to Field Ground: 2121VDC for 1 minute, 10mA Output to Field Ground: 2121VDC for 1 minute, 10mA Immunity ESD: IEC61000-4-2 Level 3 RS: IEC61000-4-3 Level 3 EFT: IEC61000-4-4 Level 2 Surge: IEC61000-4-5 Level 3 CS: IEC61000-4-6 Level 3 Voltage Dips IEC61000-4-11 Harmonic: EN61000-3-2 Class A Insulation Resistance Primary to Secondary: >10M OHM 500VDC Primary to Field Ground: >10M OHM 500VDC FEATURES: Over Voltage/Current, Short Circuit Protection The output can be shorted permanently without damage Indicators LED 1: Input power ON LED 2: Detected a invalid IEEE802.3bt Class load or output is overloaded. LED 3: Detect and Connected to a valid IEEE802.3bt load Input Connector 3 pin terminal block with M3.5 screw terminal; for appropriate connection use minimum 14AWG wire and M3.5 spade lug Output PoE Connector RJ45 Output PoE Connection +pins 3, 6, 4, 5 / -pins 1, 2, 7, 8

POE62U Characteristics Input/Output Case Ports 3 ¾ NPT holes compatible with standard ¾ NPT conduit piping or Phihong wire gland PGLAND750 with fully waterproof AC and RJ45 cables. WWW.PHIHONG.COM Network Switch Network Switch must be Environment Rated B as per paragraph 33.4.1.1 of the IEEE802.3at standard. POE62U Dimension Diagram unit:mm Single Cable Gland - PGLAND750* Dimension Diagram unit:mm Double Cable Gland - PGLAND750-2* Dimension Diagram unit:mm Note *: Cable Glands are sold separately

Safety Procedures General Precautions WWW.PHIHONG.COM General - Please read the following precautions carefully before installing and connecting the system to a power source. Note Only qualified and trained service personnel (in accordance with IEC 60950 and AS/NZS 3260) should install, replace, or service the equipment. Install the system in accordance with Country, National or to the U.S. National Electric Code if you are in the United States. Precautions: 1. The building facilities in which the product will be used must provide Isolation to the main AC Input connector. This connection requires a fuse or circuit breaker no larger than 20A for 120 VAC (U.S.A.) or 16A, 230 VAC (international). The building facilities must protect the POE62U Power injector from over current or short-circuits. 2. The POE62U power injector enclosure is IP67 tested which provides degrees of protection against access to hazardous parts, dust and against ingress of water. To ensure protection against ingress of water, torque captive screws (4 places) in an X pattern to > 27 inch pound. Only qualified service personal should install, replace or service this equipment. Before connecting, visit www.phihong.com for the latest up to date specification and contact information. 3. The POE62U power injector enclosure must be mounted vertically but not orientation limited. The enclosure is provided with a steel 2mm thick zinc plated mounting bracket. When mounting utilize the holes in the mounting bracket plate (10mm holes) 8 places. The preferred method of mounting is to a vertical 4 inch or 6 inch pole using 2 3/8 x 16 U- bolts. If mounting on a flat surface, to sheetrock or wood and or others material, use 4 M6 fasteners. Other fasteners may be used, but hardware must be sized to support 4-5 times the weight of the unit. 4. The POE62U power injector enclosure has 3 threaded (¾ NPT) openings to accommodate waterproof / water tight conduit and or cable glands. WARNING: To ensure protection against ingress of water, the connection(s) of the conduit and or cable glands are threaded with Teflon tape all the way through the holes in an enclosure wall. 5. The POE62U power injector AC input connector (located inside enclosure) is a 3 pin terminal block 9.5mm, rated 20 A, 250 V, with M3.5 Nickel Plated steel screws. The incoming 3 wire/cable must be minimum 14AWG and or in accordance with Country, National Electric Code. 6. The POE62U Power injector consists of Data & Power ports. The ports are providing TNV-1 outputs. The ports use RJ-45 data sockets. Do not connect telephone cables into these ports. Only RJ-45 data cables with waterproof / water tight connections may be connected to these sockets. 7. To prevent the POE62U Power injector from overheating, do not operate the product in an area that exceeds the maximum recommended ambient temperature of -40 ºC to +60 ºC.

8. Do not work on the POE62U Power injector or connect or disconnect cables, during periods of lightning activity. 9. The AC connector wire combination must be accessible at all times, as it serves as the main disconnect device to the product. 10. Before servicing the product, always disconnect the product from its AC source. 11. Equipment is for Pollution degree 2 Environment. 12. Disposal of this product should abide by all appropriate National laws and regulations. Installation Instructions 1) The unit is packaged fully closed with the mounting bracket pre-installed; remove from packaging and loosen the four captive screws located at the top of the midspan so that the lid can be lifted easily. 2) Using a Philips screwdriver, remove the four screws holding the protective covering for the PC Board, and the two screws for the protective covering over the AC terminal block. 3) Connect cable glands (PGLAND750) or ¾ NPT conduit piping to the face of the midspan. Ensure that connectors are fully installed to guarantee waterproof operation.

4) To better enable waterproof operation it is recommended that installers use Teflon tape to cover threads before installation. Users may also wish to use silicon sealant to further protect from ingress of liquid. 5) Thread outdoor rated waterproof AC cable (must comply with all local, national and country electrical codes) from source through piping/gland to the terminal block. The AC cable will need to be a minimum of 14AWG and terminated with M3.5 spade lugs. Pair and secure ground, line, and neutral to the appropriate positions on the three pin terminal block and reattach the protective covering. Note: if using the cable gland PGLAND750, the outer seal nut needs to be fully tightened to close rubber seal to protect against ingress of water. 6) Using waterproof outdoor rated Cat5e Ethernet cable, thread through cable glands or conduit piping to the appropriate RJ45 connector and ensure each portal is properly sealed. 7) Reattach the protective covering over the PC board and terminal blocks and re-close the lid. Ensure that the four captive screws are fully tightened before operation can commence.