Analog Voltage Combination Module

Similar documents
T1H-EBC. Communications 10Base-T Ethernet 100Base-T Ethernet Data Transfer Rate 10 Mbps 10/100 Mbps Link Distance. Ethernet Protocols

Appendix D2-262 CPU. In This Appendix...

P2-04DAL-2 Analog Output. Removable Terminal Block Specifications

P2-04DA Analog Output. Removable Terminal Block Specifications

Chapter. Specifications - Terminal Bases and Power Supplies. In This Chapter:

General Specifications. P2-8AD4DA-2 Analog Input/Output

P2-04AD Analog Input. Removable Terminal Block Specifications

DL05 CPU Specifications. Performance Contact execution (Boolean) µs Typical scan (1K Boolean) ms.

Installation and Setup

Installing the H2 -EBC(100), H2 -EBC -F or H4 -EBC( -F)

OTB1S0DM9LP I/O distributed module OTB - Modbus non isolated serial link m

Rhino Redundancy Module PSM24-REM360S. Operating Instructions

General Specifications. P2-08THM Analog Input

Stride Industrial Ethernet Switches

Installation and Setup

REDUNDANCY MODULE TSP-REM360 AND TSP-REM600

OTB1S0DM9LP I/O distributed module OTB - Modbus non isolated serial link m

RE17LAMW on-delay timing relay - 1 s..100 h V AC/ DC - solid state output

PanelView Plus/VersaView CE Terminals and Display Modules

OTB1C0DM9LP I/O distributed module OTB - CANopen bus m

OTB1E0DM9LP I/O distributed module OTB - Ethernet TCP/IP m

RE17LCBM off-delay timing relay - control - 1 s..100 h V - solid state output

AC/DC Power Adapter: EA-AC. Expansion Assembly: EA-EXP-OPT. CF Card Interface Module: EA-CF-IF. 128 MB CompactFlash Memory Card: EA-FLASH-128MB

Time Counters mini "h", DC Version

P3-SCM. General Specifications

AI561 Analog Input Module

TF501, TF521 Terminal Bases

AO523 Analog Input Module

Rhino Buffer Module PSM24-BFM600S. Operating Instructions

DeltaV Bulk Power Supplies

General Specifications. P2-08NTC Thermistor. The P2-08NTC module provides eight Thermistor input channels for use with the Productivity2000 System.

Installation Instructions

OTB1C0DM9LP I/O distributed module OTB - CANopen bus m

Removable Terminal Block Specifications

Description. 100MBit Ethernet Communication Module. 10Base-T Ethernet Module. Description

P2-16AD-2 Analog Input. Connector Specifications

Installation Instructions

RE17LAMW on-delay timing relay - 1 s..100 h V AC/DC - solid state output

C-more 3 Micro-Graphic STN Touch Panel

RTU500 series Data Sheet Power Supply CP-E 24/2.5

OTB1E0DM9LP I/O distributed module OTB - Ethernet TCP/IP m

AO561 Analog Output Module

FLEX Ex Spring Clamp Terminal Base

AX521 Analog Input/Output Module

DX561 Digital Input/Output Module

TU531, TU532 Terminal Unit

Do-more T1H Series PLC Overview

Tempco Instruction Manual

Installation and Wiring

DC562, digital input/output module,

OTB1C0DM9LP. Main , length of segment <= 185 m , length of segment <= 160 m. 3.4 kohm for I8...I kohm I0...I1 5.7 kohm I6...

DI572 Digital Input Module

This Datasheet for the IC660BBA026. Block 24/48Vdc Analog Current Source 6 Inputs.

UNT1100 Series. Binary Output Jumpers AO2 AO1 AO3 AO4 AOCM AOCM AOCM AOCM AO1. AI Switches Job Information N2 Address. Ref N2+ N2- ADDR 0 = ALL OPEN

RM22TG. Product data sheet Characteristics. three-phase control relay Vac, 2 C/O. Main. Complementary. Network number of phases

Digital ac/dc (24V) Input Module

DI561 Digital Input Module

This Datasheet for the IC660BBA104. Block 115Vac/125Vdc Analog Current Source 4 Inputs / 2 Outputs

Table of Contents. Introduction... 2 Description...2 Specifications...3 Installation.. 5 Calibration.. 6 General Maintenance...7

OTB1E0DM9LP I/O distributed module OTB - Ethernet TCP/IP m

POINT I/O Family. Chapter. Overview

Conforms to VDE0435/2021 C/250, VDE0110, VDE0106/P100 Conforms to EN , pren

Network Instrumentation Module Communications box NX-CB1 Communications adapter NX-CL1/NX-CR1 Terminal adapter NX-TL1/NX-TR1

AI531 Analog Input Module

Chrome DIN Rail Power Supply 5V 7.5W 1 Phase (Class II & NEC Class 2) / DRC-5V10W1AZ

Programmable Relay ZEN V2 Units

IO-PT4. Component identification. User safety and equipment protection guidelines. Unitronics Industrial Automation Systems 1

HITACHI. EH-150 series PLC EH-RTD8 Resistance Temperature Detective input module Instruction manual. Safety precautions

Redundancy unit CP-A RU

This Datasheet for the IC660BBD110. Block 115Vac Input 16 Circuits.

DeltaV Bulk Power Supplies

Part No. Description Product Life Cycle Phase *) unit, 24 VDC, spring terminals. unit, 24 VDC, spring terminals, XC version

DC561, digital input/output module,

V E2B Snap-in I/O Module

Do-more H2 Series PLC System Specifications

Model Number Structure

1 1 Getting Started $ "% # + %#! & %! + % $!% +!% $% # * %&# $ +!% ' *!# * %&# $ + $$ %!% "&% &%"&% # $$ $ +!( % " % $!%! %$ + $) % "$!# %% "!

AX522 Analog Input/Output Module

NJ-Series Power Supply Unit NJ-PA/PD

TM5C12D6T6L compact I/O expansion block TM5-24 I/0-12 DI - 6 DO transistor - 4 AI - 2 AO

Dold BH5928 Series 2-Channel Emergency Stop and Safety Gates with Delay

T1K MODBUS Base Controller Specifications

TM3TM3 module TM3-2 temperature inputs and 1 analog output

DC541 Digital Input/Output Module

1492-SP Supplementary Protectors

TM3AI4 module TM3-4 analog inputs

OVERLOAD RELAYS POWER & ACTUATION PROVEN. series

P3-RS Remote Slave Module

Chrome DIN Rail Power Supply 12V 9.96W 1 Phase (Class II & NEC Class 2) / DRC-12V10W1A

TM3TI4 module TM3-4 inputs temperature

V E1B Snap-in I/O Module

Legacy to New Generation Conversion Guide

General Specification

PGR-4700 MANUAL SENSITIVE GROUND-FAULT RELAY

RE22R2KMR Off-delay Timing Relay s 10min V AC/DC - 2C/O

TM3TI4 module TM3-4 inputs temperature

H704-42(H)(E), H704-42/1(H)(E)

Installation and Setup. In This Chapter... Installing the H0 PSCM The Profibus Network Configuring the Module

TM3TI8T module TM3-8 inputs temperature

TM221M16R controller M IO relay

Transcription:

Analog Voltage Combination Module T1F-8AD4DA-2 8-channel analog voltage input 4-channel analog voltage output The combination 8-in and 4-out voltage module uses a T1K-8B or T1K-8B-1 base, which is purchased separately.????????? T1F-8AD4DA-2 Analog Input Specification Channels Per Module 8 single-ended (1 common) Input Ranges 0-5V, 0-10 V, ± 5V, ± 10 V Resolution 14 bit (13 bit plus sign bit) Frequency Response -3db @ 500 Hz, -20 db/decade Input Resistance 200 K min. Fault Protected Input Absolute Max. Ratings 130V(rms) or 100 VDC Conversion Time 5.5ms per channel Linearity Error ± 2 count max. Input Stability ± 1 count Calibration Full Scale Error 8 counts max. Calibration Offset Error 2 counts max. Max. Full Scale Inaccuracy (% of full scale), all errors included 0.08% @ 25 C 0.26% @ 60 C Master Update Rate 8 channels per scan max. 256 discrete pts. or Input Points Required 8 dwords (32-bit words) (Network Interface Dependent) Base Power Required 75 ma @ 5 VDC External Power Supply 21.6-26.4 VDC, 70 ma, class 2 Weight 136 g T1F-8AD4DA-2 Analog Output Specification Number of Channels 4 Output Ranges 0-5V, 0-10 V, ± 5V, ± 10V Output Type single ended, 1 common Resolution 12 bit (1 in 4096) Peak Output Voltage 15 VDC Load Impedance 4 K min. Load Capacitance Linearity Error (End to End) Conversion Settling Time Full Scale Calibration Error Offset Calibration Error Accuracy vs. Temperature Max. Full Scale Inaccuracy (% of full scale) All errors and temp drift included Master Update Rate Output Points Required 0.01 µf max. ± 2 counts max. ± 0.05% of full scale max. 300 µs max. full scale change ± 12 counts max. 10 V ranges: ± 5 counts max. 5V ranges: ± 9 counts max. ± 50 ppm/ C full scale calibration change 10V ranges: ± 0.2% @ 25 C ± 0.4% @ 60 C 5V ranges: ± 0.3% @ 25 C ± 0.5% @ 60 C 4 channels per scan max. 128 discrete pts. or 4 Dwords (32-bit words) (Network Interface Dependent) Equivalent Input Circuit Equivalent Output Circuit NOTES: 1: Shields should be grounded at the signal source. 2: Unused inputs should be connected to common (0 VDC). 3: More than one external power supply can be used, provided all the power supply commons are connected. NOTES: 1: Shields should be connected to the 0V terminal of the module or the 0V of the power supply. 2. Unused current outputs should remain open (no connections) for minimum power consumption. 7 56 Universial Field I/O

Dimensions and Installation It is important to understand the installation requirements for your Terminator I/O system. This will ensure that the Terminator I/O products work within their environmental and electrical limits. See the Enclosures section of this catalog for an enclosure that may be suitable for your application Plan for safety This catalog should never be used as a replacement for the technical data sheet that comes with the products or the T1K-INST-M Installation and I/O Manual (available online at www.automationdirect.com.) The technical data sheet contains information that must be followed. The system installation should comply with all appropriate electrical codes and standards. Unit dimensions and mounting orientation Use the following diagrams to make sure the Terminator I/O system can be installed in your application. Terminator I/O units should be mounted horizontally. To ensure proper airflow for cooling purposes, units should not be mounted upside-down. It is important to check the Terminator I/O dimensions against the conditions required for your application. For example, it is recommended to leave 2 depth for ease of access and cable clearance. However, your distance may be greater or less. Also, check the installation guidelines for the recommended cabinet clearances. Terminator I/O Environmental Specifications Ambient Operating Temperature 32 F to 131 F (0 C to 55 C) Storage Temperature -4 F to 158 F (-20 C to 70 C) Ambient Humidity 5% to 95% (Non-condensing) No corrosive gases. The level of environmental Atmosphere pollution = 2 (UL 840) Vibration Resistance MIL STD 810C, Method 514.2 Shock Resistance MIL STD 810C, Method 516.2 Voltage Withstand (Dielectric) 1500 VAC, 1 minute Insulation Resistance 500 VDC, 10 M NEMA ICS3-304 Impulse noise 1µs, 1000 V Noise Immunity FCC class A RFI (144 MHz, 430 MHz 10 W, 10 cm) Agency Approvals UL, CE, FCC class A, NEC Class 1 Division 2 48mm (1.89in) 48mm (1.89in) 48mm (1.89in) 89mm (3.5in) 83.3mm (3.28in) Power Supply Network Interface Module Half-size I/O Module with Base Full-size I/O Module with Base System Depth 7 14 Universial Field I/O

I/O Module Installation Overview I/O module installation Terminator I/O modules feature separate terminal bases for easy installation. To install I/O modules: 1. Slide the module into its terminal base (until it clicks into position) 2. Hook upper DIN rail tabs over the top of DIN rail, and press the assembly firmly onto the DIN rail. 3. Slide the module along the DIN rail until it engages with the adjacent module. 1 DN-ASB-1 angled mounting bracket Great for mounting in upper locations Great for mounting in lower locations DL05/06 DL105 DL205 DL305 DL405 Field I/O 2 Optional angled support bracket raises and tilts the mounting rail for easier access and wiring. Use with 35 mm DIN rail. See the Connection Systems in this catalog for details. Software C-more HMIs Other HMI AC Drives Motors 3 Steppers/ Servos Motor Controls Proximity Photo Limit Switches Encoders Removing I/O modules is a snap Grip the locking handle, as shown, and pull gently to eject the I/O module from its base. The module will slide out for easy replacement. This procedure does not apply to network interface modules or power supplies, which have integral bases. Hot-swappable I/O modules You can remove I/O modules under power, but exercise caution while doing so. Do not touch the terminals with your hands or any conductive material. Always remove power when possible. Pushbuttons/ Lights Process Relays/ Timers Comm. TB s & Wiring Power Enclosures Appendix Part Index www.automationdirect.com/fieldio Universial Field I/O 7 15

Power Supplies and Power Requirements Power supplies The Terminator I/O product line offers two power supply options: AC or DC. The power supplies are always positioned to the left of the modules to which they supply power. Consult the system configuration examples and the power budgeting example for more information on positioning power supplies. Power supply specifications Power Supply Specifications T1K-01AC T1K-01DC Power requirements Interface Modules T1H-EBC 350 0 T1H-EBC100 300 0 T1H-PBC 530 0 T1K-DEVNETS 250 45 T1K-RSSS 250 0 T1K-MODBUS 300 0 DC Input Modules T1K-08ND3 35 0 T1K-16ND3 70 0 AC Input Modules T1K-08NA-1 35 0 T1K-16NA-1 70 0 DC Output Modules T1H-08TDS 200 0 T1K-08TD1 100 200* T1K-16TD1 200 400* T1K-08TD2-1 200 0 T1K-16TD2-1 200 0 AC Output Modules T1K-08TA 250 0 T1K-16TA 450 0 T1K-08TAS 300 0 Relay Output Modules T1K-08TR 350 0 T1K-16TR 700 0 T1K-08TRS 400 0 Specialty Modules T1H-CTRIO 400 0 * Use either internal or external source for 24VDC Analog Input Modules T1F-08AD-1 75 50* T1F-08AD-2 75 50* T1F-16AD-1 75 50* T1F-16AD-2 75 50* T1F-14THM 60 70* T1F-16RTD 150 0 Analog Output Modules T1F-08DA-1 75 75* T1F-08DA-2 75 75* T1F-16DA-1 75 150* T1F-16DA-2 75 150* Combination Analog Modules T1F-8AD4DA-1 75 60* T1F-8AD4DA-2 75 70* * Use either internal or external source for 24VDC Input Voltage Range 110/220 VAC 12/24 VDC Input Frequency 50/60 Hz N/A Maximum Power 50 VA 30 W Max. Inrush Current 20 A Insulation Resistance Voltage Withstand 5VDC PWR 24VDC PWR Fuse 10 A > 10 M @ 500 VDC 1 min. @ 1500 VAC between primary, secondary and field ground Voltage 5.25 VDC 5.25 VDC 2000 ma max Current Rating (see current option note below) 2000 ma max Ripple 5% max. 5% max. Voltage 24 VDC N/A 300 ma max. Current Rating (see current option note below) N/A Ripple 10% max. N/A 1 (primary), not replaceable Note: 500 ma @ 24 VDC can be achieved by lowering the 5VDC from 2000 ma to 1500 ma. Calculating the power budget To calculate the power budget, read the available power (current rating) from the Power Supply Specifications table and subtract the power consumed by each module to the right of the power supply. Do not include modules to the right of an additional power supply. Adding additional power supplies Each power supply furnishes power only to the network interface and I/O modules to its right. Inserting a second power supply closes the power loop for the power supply to the left, while also powering the modules to its right. Perform a power budget calculation for each power supply in the system. Power Budget Example T1K-01AC +2000 ma +300 ma T1H-EBC -350 ma -0 ma T1K-16ND3-70 ma -0 ma T1K-16TD2-200 ma -0 ma T1F-08AD-1-75 ma -50 ma Remaining +1305 ma +250 ma Accessories available for Terminator I/O are listed in the Terminator Field I/O section of the Price List This power supply powers the network interface module and the next two I/O modules This power supply powers these three I/O modules 7 16 Universial Field I/O

Expansion I/O Configurations T1K-05CBL-LL T1K-05CBL-LL-1* Left side to left side expansion cable Expansion cables T1K-10CBL T1K-10CBL-1* Right side to left side expansion cable The T1K-10CBL(-1) connects the right side of an I/O base to the left side of the next I/O base. A maximum of two T1K-10CBL(-1) cables can be used per expansion system. Overview T1K-05CBL-RR T1K-05CBL-RR-1* Right side to right side expansion cable The T1K-05CBL-LL(-1) connects the left side of an I/O base to the left side of the next I/O base. Only one T1K-05CBL-LL (-1) cable can be used per expansion system and must be used with a T1K-05CBL-RR(-1) cable. This cable cannot be connected to the left side of the network interface base. The T1K-05CBL-RR(-1) connects the right side of an I/O base to the right side of the next I/O base. A maximum of one T1K-05CBL-RR(-1) cable can be used per expansion system. Note: When this cable is used, the expansion I/O assignments are from right to left (reversed). DL05/06 DL105 DL205 DL305 DL405 Field I/O Software Cable length = 1.0m C-more HMIs Cable length = 0.5m Cable length = 0.5m Other HMI AC Drives *Note: The (-1) versions of the expansion cables pass 24 VDC through on an isolated wire. (All cables pass the 5 VDC base power.) Any local expansion DC input module configured for internal power (current sourcing) must either have a power supply preceding it on the same base or, have a (-1) version cable pass 24 VDC from a power supply on the preceeding base. Using two T1K-10CBL expansion cables Using T1K-10CBL expansion cable and T1K-05CBL-RR expansion cable In the system below, power supplies can be used anywhere. A power supply can be used on either base. Steppers/ Servos Motor Controls Power supplies can be used anywhere in the first two bases, but not in the last expansion base. T1K-10CBL(-1) Motors Proximity Photo Limit Switches T1K-10CBL(-1) T1K-10CBL(-1) Encoders Pushbuttons/ Lights A power supply cannot be used on a base that is connected to a system by a T1K-05CBL-RR(-1). T1K-05CBL-RR(-1) See Note above Process Relays/ Timers Using T1K-05CBL-RR expansion cable and T1K-05CBL-LL expansion cable Power supplies can be used anywhere in the first and third bases, but not in the second base. Do not connect a T1K-05CBL-LL(-1) to the left side of the network interface base. Comm. Using T1K-05CBL-RR expansion cable Power supplies can be used anywhere in the first base, but not in the second base. TB s & Wiring Power Enclosures T1K-05CBL-RR(-1) See Note above T1K-05CBL-RR(-1) See Note above Appendix Part Index T1K-05CBL-LL A power supply cannot be used on a base that is connected to a system by a T1K-05CBL-RR(-1). w w w. a u to m at i o n d i re c t. c o m / f i e l d I O A power supply cannot be used on a base that is connected to a system by a T1K-05CBL-RR(-1). Universial Field I/O 7 17

Field Device Wiring and Power Options Terminal base specifications Terminator I/O terminal bases are available in screw clamp and spring clamp versions for both half-size and full-size modules. Hot stamp silkscreen labeling is used for numbering I/O points, commons, and all power terminals. T1K-08B T1K-08B-1 Screw clamp, half-size Spring clamp, half-size Terminal Base Specifications Terminal Type Screw type Spring clamp Recommended 1.77-3.54 lb-in Torque (0.2-0.4 Nm) Wire Gauge Solid: 25-12 AWG Stranded: 26-12 AWG n/a Solid: 25-14 AWG Stranded: 26-14 AWG T1K-16B T1K-16B-1 Field device wiring options Power your DC input devices from the integrated 24 VDC power supply bus. T1K-08ND3 and T1K-16ND3 DC input modules include jumpers for selecting the internal 24 VDC power supply available for 2- and 3-wire field devices. Clearly labeled triple stack terminals make it easy to wire 2- and 3-wire devices ensuring clean wiring with only one wire per termination. External user supplied 24 VDC power, or auxiliary 24 VDC terminals from T1K-01AC, can be easily applied directly to one end of the terminal rows and jumpered across each base in the system. This is a convenient solution for powering analog I/O and discrete DC output devices whose modules do not have direct access to the internal bussed 24 VDC. If current consumption increases, simply add additional T1K-01AC power supplies into the system. 2 and 3-wire DC input devices using bussed 24 VDC power Use externally supplied 24 VDC power or 24 VDC auxiliary power from T1K-01AC Screw clamp, full-size Do not jumper modules together to create a 24 VDC bus when using the hot swap feature. See Note below. Spring clamp, full-size Hot-swap feature The hot-swap feature allows Terminator I/O modules to be replaced while system power is on. Be careful not to touch the terminals with your hands or other conductive material to avoid the risk of personal injury or equipment damage. Always remove power if it is equally convenient to do so. 7 18 Universial Field I/O Note: Before hot-swapping analog or DC output modules in a Terminator I/O system, make sure that each of the analog and DC output module s 24 VDC and 0 VDC base terminals are wired directly to the external power supply individually. If the external 24 VDC and 0 VDC is jumpered from base to base in a daisy chain fashion, and an analog or DC output module is removed from its base, the risk of disconnecting the external 24 VDC and 0 VDC to the subsequent I/O modules exists.