User Manual. SSA-20 - CO 2 Incubator Analyser

Similar documents
User s Guide RDXL6SD-USB. Temperature Data Logger with USB. Shop online at omega.com

Wide Range Pressure Meter Instruction Manual

Otium One Smart Watch User Guide Please read the manual before use. * For further information, please visit

User s Guide. OM-CP-PRHTEMP2000 Pressure, Humidity and Temperature Data Logger with LCD

Xxxxx Xxxxxx Bridge / Strain Gauge Data Logger

FMA-7400/7500 Series Configurator

User s Guide. OM-CP-HITEMP140-M12 High Temperature Data Logger with an M12 Probe Connector

Xxxxx Xxxxxx OM-CP-QUADVOLT. OM-CP-OCTVOLT 8-Channel Low Level DC Voltage Data Logger. 4-Channel Low Level DC Voltage Data Logger INSTRUCTION SHEET

User Manual. isense Methane & Carbon Dioxide Sampling Data Logger CM Table of Contents TABLE OF CONTENTS... 2

Datalogging IAQ Meter Instruction Manual

High Temperature Data Logger

FT-20 Fire Training Fog Machine User Manual English

E8431 First Edition Model: T00CP

User s Manual. CO2 Sampling Data Logger. Models Covered ESCM 01 ESCM 02 ESCM 03 ESCM 50 ESCM 56. See Table 1 on page 7 for details.

Manometers 2PSI, 5PSI, 15PSI, 30PSI, 100PSI , , ,

ARA FTS Flow Calibrator. Operation Manual August 1, 2016

Torque Meter. Instruction Manual

CO2 Controller Operating Instructions Models: RAD-0501, RAD-0501A, RAD-0501E 1. Product Description

P OCKET POWER 9000 T. Powerful Universal Portable Charger PLEASE READ BEFORE OPERATING THIS EQUIPMENT

W IRELESS8000 T. Powerful Universal Portable Charger PLEASE READ BEFORE OPERATING THIS EQUIPMENT

CONTENTS 1. BOOMBOT ANATOMY 2. GETTING STARTED 3. BLUETOOTH PAIRING 4. AUDIO CONTROLS 5. SPECIFICATIONS 6. TROUBLESHOOTING 7.

User s Guide. OM-HL-SH Series. Single Channel Temperature and Humidity Data Logger, Handheld. Shop online at omega.com

User s Guide OM-SGD-28-M. Shop online at omega.com. Smart Graphics Display. For latest product manuals:

ZipCharge. User Guide. Ultra fast-charging portable power stick. Revision 1.04

User s Guide TXDIN1700. Universal DIN Rail. Shop online at omega.com SM. For latest product manuals:

User's Guide Video Borescope Model BR200

User s Guide. OM-HL-SH Series. Single Channel Temperature and Humidity Data Logger, Handheld. Shop online at omega.com

English. Instruction and operation manual S 505. Dew point meter (portable)

P OCKET POWER 6000 T. Powerful Universal Portable Charger PLEASE READ BEFORE OPERATING THIS EQUIPMENT

Xxxxx Xxxxxx DC Voltage Data Logger

Troubleshooting Tips & Procedures. Model 8800 series. GeoNet Wireless

4-Channel Thermometer

NEBULA X USER MANUAL. Redefining Tradition. Read carefully before using the device and save these instructions.

DPL4000 Portable Low Range Dew Point Analyzer

SHINE 3000 WITH FASHION CABLE

impact INSTRUCTIONS LiteTrek 4.0 Monolight lighting equipment and accessories

FT-20 Fire Training Fog Machine User Manual English

CO2 Sampling Data Logger User s Manual

Portable. GL100 An eye on your mobile property. User Guide

KI6501 Optical CWDM Power Meter. User Manual. KI6501 series Optical CWDM Power Meter

User s Guide. OM-HL-EH-TC Series Multi-channel Handheld Thermocouple Temperature Data Logger. Shop online at omega.com

Light Meter (Foot Candles)

Vacuum Tubes Power Supply Unit. for WA7 and WA7d Fireflies. Owner s Manual. Please review this manual before operating your WOO AUDIO product.

User s Guide HHPT-51. Particle Counter. Shop online at omega.com. For latest product manuals:

User s Guide. OM-HL-SP Series. Single Channel Temperature and Humidity USB Data Logger, Pen Size. Shop online at omega.com

Datalogging RH / Temperature Pen Instruction Manual

DoorEye Camera MDOOREC101012E

Exposure Monitoring. Model 8560 INSPECTAIR CO 2. Meter. Operation and Service Manual , Revision B June 2006

Large Display Salinity & Conductivity Pens &

NV618W (La Moon) User s manual

Tesla TI Generator Set Interface

Anemometer SD Card Datalogger. Instruction Manual

User s Guide. OM-HL-SP Series Single Channel Temperature and Humidity USB Data Logger, Pen Size. Shop online at omega.com

User Guide Microsoft Portable Power (DC-21)

User s Guide HHSL-101. USB Digital Sound Level Data Logger. Shop online at omega.com SM

User s Guide TSD600. Shop online at omega.com SM. For latest product manuals: omegamanual.info

User Manual AIMB-C200. Economical Embedded Chassis for Mini-ITX Motherboard

Model OI-9100 Signal Strength Meter The View

Datalogging Conductivity/ TDS Meter. Instruction Manual

Users Manual OPN Pocket Memory Scanner

b. Time Setting c. Volume Setting d. Backlight Setting e. Sleep Setting f. Pin Setting g. Joystick Calibration...

User's Guide. Phase Sequence and Motor Rotation Tester Model

CO Analyzer. The Value Leader TM

SHUTTERBOSS VERSION II USER MANUAL

Mini Environmental Quality Meter

Car air purifier USER S GUIDE ver. 1.0 EN

Halo One. better in one

4-Channel Datalogging Thermometer

Atomic Projection Alarm

AEROTRAK PORTABLE AIRBORNE PARTICLE COUNTER MODEL 9310/9350/9510/9550/9500 QUICK START GUIDE

Fixed Wireless Phone. User Manual

7 Digital Photo Frame

Ambient Weather WS-HT350 Fast Response Air Thermo-Hygrometer with Wet Bulb, Dew Point Meter User Manual

Table of contents. 1 Get Started 2. 2 Using Snapshot 4. 3 Safety, Handling, & Support 8

Manual. Bluetooth Headphone X9. Please read this manual before operating your headset, and keep it for future reference.

OLS Series Light Sources, OPM Series Optical Power Meters, and Related Test Kits User s Guide

KI Channel Optical CWDM Power Meter. User Manual. KI6503 series 48-Channel Optical DWDM Power Meter

U S B T H R O T T L E Q U A D R A N T D E S K TO P C O N S O L E

JANOME DESKTOP ROBOT JR2000N Series. Operation Manual. <Setup> For Qualified Installer ONLY

Thermal Diffusivity Instruments DLF-2 with EM-1600

Laboratory-precise analysis, anywhere. PORTABLE GAS ANALYZER PG-350 E

Royal. Wi-Fi Memory Expander

TABLET PC. Quick Start Guide. Model: TVE100 I

Quick Start Guide. Liquid Dosing Pump. Register your new product today at

User Guide. Moisture Meter. Model MO250

Kolectric Research. MC8022 Covermeter. Document number IM Iss 1 Copyright 2014 Tallix Ltd

POCKET BLUETOOTH SPEAKER WITH POWER CHARGER

AirPro Surveyor 2 Manual

ESV1200 Quantum Illuminator Cabinet INSTRUCTION MANUAL

USERS GUIDE MCX-STH. 3G SDI to HDMI Converter. Manual Number:

RH/Temperature SD Card Datalogger. Instruction Manual

MEEM Memory Ltd. User Guide ios

Owner's Manual. For latest instructions please go to

User s Guide CS8DPT SERIES. Benchtop Controllers. Shop online at omega.com. For latest product manuals:

Additional Camera Unit for Angelcare Monitors AC-CAM Compatible with models: AC517 - AC510 AC417 AC315 AC310

EO-BG930. User Manual. English (EU). 07/2016. Rev.1.0.

CO2 1% or 30%, Temperature & %RH, Diffusion Data Loggers

ZelHer P30 USER GUIDE

AquaShock ph Meter K

User Manual for the Antari M-1 Mobile Fog Machine. Congratulations on the purchase of your new ANTARI M-1 Mobile Fog Machine

Transcription:

User Manual SSA-20 - CO 2 Incubator Analyser 1

Introduction The SSA-20 is the new handheld CO 2 analyser specially designed by Samson Scientific to measure, verify and validate the CO 2 levels on CO 2 Incubators. The SSA-20 offers the user an easy to use and accurate CO2 analysis tool with the backup of our excellent after sales support package. Easy to use Fast and intuitive touch screen driven user interface. It s fast Solid state sensor technology with extremely fast start time and minimal warm up mean the SSA-20 can practically complete its full check and measurement cycle before other Analysers have even got the splash screen out of the way. The SSA-20 CO 2 Analyser is extremely easy to use but it is essential that these Operating Instructions are read prior to use. Copyright Copyright 2014 Samson Scientific Ltd No part of this User Manual may be reproduced, distributed, translated, or transmitted in any form or by any means, electronic or mechanical, including photocopying, recording, or storing in any information storage and retrieval system, without the prior permission of Samson Scientific. 2

Getting Started Case contents 1. SSA-20 CO2 Analyser 2. 1 metre of sample tubing with filter and 1 x Spare Filter 3. User Manual 4. Mains charger with UK AC head 5. USB A Male to Right Angle Mini USB 6. US, EU and AU Mains charger heads 3 6 1 5 4 2 3

Getting Started Device Layout 1. On/Off Button 2. Gas Inlet Luer 3. Touch screen 4. USB/ charging port 5. Tilt stand 6. Gas outlet 1 2 3 5 4 6 4

Getting Started Charging the battery Use the charger to charge the battery before using it for the first time. A computer can be also used to charge the device by connecting them via the USB cable. NOTE: The device should always be switched On while charging. The device can be used while it is charging, but it may take longer to fully charge the battery. IMPORTANT NOTE: Use only Samson Scientific approved chargers, batteries, and cables. Unapproved chargers or cables can cause the battery to explode or damage the device. Charging with the charger Connect the USB cable to the USB power adaptor and then plug the end of the USB cable into the SSA-20 USB port. IMPORTANT NOTE: Connecting the charger improperly may cause serious damage to the device. Any damage caused by misuse is not covered by the warranty. Checking the battery charge status When charging the device the battery charge status icon will appear in the middle of the screen: Charging Charged After fully charging, disconnect the device from the charger. 5

Getting Started Connecting the tubing and filter IMPORTANT NOTE: Always ensure that the filter provided is used. Connect the filter and tube to the gas inlet luer connector. Push the filter onto the luer and twist clockwise to lock. 6

Operation Switching the unit ON/OFF Press the button. The unit is now switched on. After being turned on, the SSA-20 will start up within 6 seconds and the current CO 2 measured value will be displayed. To turn the SSA-20 Analyser off, press the button again. Indicator icons The icons displayed on the screen provide information about the status of the device. The icons listed in the table below are most common. Icon Meaning Battery power level Pump running HOLD Measurement Hold enabled Battery level low connect charger 7

Home Screen layout The Home screen of the SSA-20 is the starting point to access all of the device s features. It displays the currently measured PERCENT CO2 level, indicator icons, Hold, Menu and Pump buttons. Using the touch screen IMPORTANT NOTE: Use only fingers to use the touch screen. Do not allow the touch screen to come into contact with other electrical devices as electrostatic discharges could cause the touch screen to malfunction. Do not allow the touch screen to come into contact with water. The touch screen may malfunction in humid conditions or when exposed to water. To avoid damaging the touch screen, do not tap it with anything sharp or apply excessive pressure to it with your fingertips. To operate any of the on-screen buttons, tap it with a finger. 8

Operation Sampling/Measuring Mode IMPORTANT NOTE: Always ensure that the filters provided are used and replaced regularly IMPORTANT NOTE: Before sampling CO2 for the first time perform a Calibrate in Air by following the Calibration procedure. IMPORTANT NOTE: We recommend that the SSA-20 is zeroed in air at the beginning of each day of use. To turn on the integral gas pump, briefly press the Pump button. To turn off the pump, again briefly press the Pump button. Resolution adjustment To adjust the measurement resolution from 1 decimal place to 2 decimal places tap the Percent CO2 area of the screen. Measurement procedure When sampling the CO2 level of a CO2 Incubator, connect the SSA-20 tubing to the sample port and press the Pump button to turn on the metering gas pump. A sample of the atmosphere from the CO2 Incubator will then be drawn in through the tube and the PERCENT CO2 reading will start to change as the gas to be measured is drawn into the unit. Monitor the reading until it stabilises. This will typically take around 90 seconds. Take note of the reading and press the Pump button to turn off the metering gas pump. IMPORTANT NOTE: As the atmosphere in an incubator is normally kept at a high humidity we recommend that you DO NOT leave the analyser sampling on a humidified incubator for longer than 2 minutes. After sampling on a humidified Incubator for a long period we recommend that you continue to run the analyser pump in air for 30 seconds to flush out any humidity which could have built up inside the sensor. 9

Calibration Zero Calibration The SSA-20 can be calibrated in clean outside air or by using Nitrogen. Calibrate in Air IMPORTANT NOTE: It is essential to ensure that the unit is in clean air in an outdoor environment before attempting an air calibration and ensure your exhaled breath does not affect the procedure. Failure to adhere to these guidelines could result in an incorrect calibration result. From the home screen press Menu Press Calibrate in Air and follow the on screen instructions. Press the Pump button and run the pump for 1 minute. When the reading has stabilised press Calibrate and the SAA-20 will adjust the level to atmospheric CO2 0.04%. Press the Pump button to switch off the pump. Press the Back button two times to return to the home screen. Calibrate in Nitrogen From the home screen press Menu Press Calibrate in Nitrogen and follow the on screen instructions. Connect a Nitrogen source with pressure set no higher than 0.3L/min and press the Pump button. Run the pump for 90 seconds and when the reading has stabilised press Calibrate and the SAA-20 will adjust the level to CO2 0.00%. Press the Pump button to switch off the pump. Press the Back button two times to return to the home screen. Reference to Calibrated Gas IMPORTANT NOTE: It is essential to ensure that the unit is in clean air in an outdoor environment before attempting an air calibration and ensure your exhaled breath does not affect the procedure. Failure to adhere to these guidelines could result in an incorrect calibration result. From the home screen press Menu Press Reference to Calibrated Gas and follow the on screen instructions. Connect a calibration gas supply with pressure set no higher than 0.3L/min and press the Pump button. Enter the value of the calibration gas cylinder by using the Down and Up buttons. The default value is 5.00 but this value can be adjusted to any level from 0-21%. Run the pump for 90 seconds and when the reading has stabilised press Calibrate and the SAA-20 will adjust the measured level to CO2 5.00%. Press the Pump button to switch off the pump. Press the Back button two times to return to the home screen. 10

Service, Factory Calibration, Technical Support & Warranty Servicing There are no user-serviceable parts inside the SSA-20 CO2 Analyser. Unauthorised removal of the back of the unit will invalidate the warranty. Your SSA-20 CO 2 analyser should be regularly calibration checked - a range of calibration check gases can be supplied by Samson Scientific Ltd and we recommend the analyser is serviced at regular intervals (twelve months). The inline filter, connecting to the gas inlet port must be replaced when the PTFE membrane becomes contaminated or saturated with moisture. New filters are available from Samson Scientific. Getting Technical Support If you have questions about the use or features of your SSA-20 CO2 Analyser or have any issue, please call +44(0)845 094 9743 or email enquiries@samsonscientific.com for technical support. When you call or contact us for support, please include as much information as you can along with the Serial Number of your unit. This will allow us to help you more quickly. Warranty Samson Scientific warrants this unit to be free of defects in materials and workmanship for a period of 12 months from date of purchase. If the unit malfunctions, it must be returned to the factory for evaluation. Samson Scientific s Customer Service Department will issue an Authorized Return (AR) number immediately upon phone or written request. Upon examination by Samson Scientific, if the unit is found to be defective, it will be repaired or replaced at no charge. Samson Scientific s WARRANTY does not apply to defects resulting from any action of the purchaser, including but not limited to mishandling, improper interfacing, operation outside of design limits, improper repair, or unauthorized modification. This WARRANTY is VOID if the unit shows any evidence of having been tampered with or shows evidence of having been damaged as a result of excessive corrosion, current, heat, moisture, vibration, improper specification, misapplication, misuse or other operating conditions outside of Samson Scientific s control. 11