Vanguard Applications Ware Release 6.1.T14A Advisory Notice

Similar documents
Vanguide Application Set Installation Guide. Overview. Introduction

Vanguard Applications Ware Software Release Notice Release 6.2.R000. Overview. Introduction

Vanguard Applications Ware Software Release Notice Release 6.1.R000. Overview. Introduction

This notice contains information on software improvements and changes made by the Vanguard Applications Ware Release Service Pak 7.2S100.

Welltech WellGate User Manual

Com.X10 Quick Start Guide

SmartWare R5.6 Release Notes

Com.X5 Getting Started Guide

Using the Cable Monitor Tool

Programming Guide KX-TDA5480 KX-TDA Channel VoIP Gateway Card. Model

AP5850 Multiservice Router

Emergency Call Analog FXO Phone High Performance Emergency Call Analog FXO Phone Solution

SCOPIA 100 Gateway Quick Start Version 5.6

Release Notes for DrayTek VigorBX 2000 series (UK/Ireland)

Getting Started. 16-Channel VoIP Gateway Card. Model No. KX-TDA0490

VoIP, Embedded Gatekeeper System AP-GK1000. February Technology.

for VoIP Gateway Series

Understanding NM-1V and NM-2V Voice Network Modules

Manual PBX IP Version: 1.0

Ch. 5 - ISDN - Integrated Services Digital Network

ATCOM IPPBX IP01 Product Guide Version: VoIPon Tel: +44 (0) Fax: +44 (0)

ANSEL FXS / 1 PSTN. VoIP Telephone Adaptor. User Manual V1.10

AP-MC1500 Audio MCU(Multipoint Control Unit) High-performance Audio MCU Solution

Release Note for Vigor2820 Series

Broadband Router DC-202. User's Guide

Voice/Fax Over IP Networks Model MVP120. Proprietary Mode. User Guide

IntelliServer RAS 2000 TM PowerRack Windows NT Supplement

Cisco Configuration Assistant

SmartWare R6.10 Release Notes

RAD KILOMUX-2100/2104

User s Manual ADSL Router Modem DB Ethernet Ports

Network Client. Troubleshooting Guide

Configuration Notes 281

Vanguard Applications Ware Multi-Service Feature Protocols

LevelOne. User's Guide. Broadband Router FBR-1402TX FBR-1403TX

Understanding Cisco Unified Communications Manager Voice Gateways

Standalone Voice/IP Gateway Model MVP400 and MVP800. H.323 Mode. Quick Start Guide

Grandstream Networks, Inc. HA100 High Availability Kit for UCM6510 Deployment Guide

IOLINK-SOHO Ethernet Bridge/Router. PPP Menus Reference Manual

Updating E2 Controller Firmware Using UltraSite32

SoLink-Lite IP-PBX. Administrator Guide. (Version 1.0)

SmartWare R6.8 Release Notes

Standalone Voice/IP Gateway Model MVP120 H.323 Mode. Quick Start Guide

Webinar Training Series NetBorder Express Version 4.0. March 29, 2011

Pilot RCU Light 3.0 FAQ V11.10

Application Note Configuring the Ascend MAX800 for use with Clipmail in a private network

Total Control System Application Guide

Voice Communication for Free High Performance Embedded VoIP Gateway

VG-422R. User s Guide

Downloaded from manuals search engine

EN Series / EXN. Telephone Entry & Access Control System. Quick Start Guide (EN-2A4) ( EXN )

Installing the Cisco Unified Videoconferencing 3545 MCU

Broadband Router DC 202

Table of Contents. 1 Introduction. 2 Wireless Configurations. 3 Setting Up your LAN Administrator Station

Perle Dial-Out User s Guide

IP High Quality Audio Broadcasting Server

Figure: ATCOM IPPBX IP04. ATCOM IPPBX IP04 Product Guide Version:

Added SerialNumber object to ECESSA-MIB Description Device serial number is readable via ECESSA-MIB::SerialNumber.0.

Matrix SETU ATA. VoIP Adaptors with FXO, FXS, GSM Ports and Multiple SIP Accounts

Series 500 Frame Relay/Leased Line Bridge/Router PPP Menu Reference Manual

N412 Installation Guide

Voice/Fax Over IP Networks Model MVP120. H.323 Mode. User Guide

BiPAC 8200M. BiPAC 8200N

CGW-I Cellular Gateway BRI-GSM Interface

Using RAD Vmux voice trunking over FleetBroadband

Products & Services Understanding Digital Modem Network Modules on Cisco 3600 and 3700 Series Routers

Using a PSTN Mediatrix Gateway (FXO, PRI, BRI) with a 3CX IP PBX

Remote Access Servers ( Ethernet & Token Ring )

Voice/Fax Over IP Networks Model MVP110. H.323 Mode. User Guide

Release Note for N412

Application Notes for Configuring Yealink T-18 SIP Phones to interoperate with Avaya IP Office - Issue 1.0

IP PUBLIC ADDRESS INTERFACE

How to Configure an Avaya TM IP600 Server With MultiTECH Systems MVP200 Gateway - Issue 1.0

UIP1869V User Interface Guide

IP Office Technical Bulletin

SS7 VoIP Gateway Solution

AT&T IP Flexible Reach And IP Toll Free Cisco Unified Communication Manager H.323 Configuration Guide. Issue /3/2008

First Aid. For All Mediatrix units. Revision

Configuring Synchronized Clocking

Software Upgrade Online Help

Setting Up Your Cisco Unified Videoconferencing 3500 Gateway

INTRODUCTION TO UPGRADING THE FRAME CONTROLLER IMAGE

E1/T1 or Fractional E1/T1 Modular Access Device with Integrated Router

Getting Started Guide for the Remote Access Dial-in Ethernet Modem 9300-RADES

First Aid. For All Mediatrix units. v

SmartWare R6.11 Release Notes

CMG Router QUICK START GUIDE

First Aid. For all Mediatrix units. Revision

MCS Software Installation Guide

technical bulletin Updating E2 Controller Firmware Using Ultrasite32

Internet Telephony PBX System IPX Quick Installation Guide

Configure Gateways. Gateway Overview. Gateway Overview, page 1 Gateway Setup Prerequisites, page 3 Gateway Configuration Task Flow, page 4

General Introduction - System description - Hardware configuration Hardware Installation OAM programming description

CHAPTER 7 ADVANCED ADMINISTRATION PC

Installation Procedure Red Hat 7 with Netscape 6

First Aid. For All Mediatrix units. v

OfficeMaster SBA (Survivable Branch Appliance)

Lab DHCP Client Setup

SmartWare R6.1 Release Notes

124i Enhanced 4 VoIP PCB. Installation Manual

Transcription:

Page 1 of 9 Vanguard Applications Ware 6.1.T14A Advisory Notice Introduction Install the Patch Executable File This notice contains information on software improvements and changes made by the Vanguard Applications Ware 6.1.R000 patch 6.1.T14A which is based on the Service Pak 6.1.S100. This notice supplements the Vanguard Applications Ware 6.1.R000 Software Notice (Part T0001-42). Follow these steps to install the 6.1.R000 patch 6.1.T14A executable file: Step Action 1 If you have not already done so, install Vanguard Software Builder from any Vanguide 6.1.R000 CD-ROM (Part 72608-30 A). 2 Download the V61T14A.ZIP file from Vanguard Managed Solutions, please save the file to a local drive on your computer. The V61T14A.ZIP file is available on the web at: http://www.vanguardms.com/support/software_and_tools/ vanguard/special_releases/ 3 Use WinZip to extract the ZIP file. The V61T14A.ZIP file contains the V61T14A.EXE, FLASHTL.EXE, VGNDTERM.EXE, UNLOCK.EXE, 7310/R61T14A/61T14T11.EXE 7310/R61T14A/61T14T12.EXE 7310/R61T14A/61T14T15.EXE 7330/R61T14A/61T14U11.EXE 7330/R61T14A/61T14U12.EXE 7330/R61T14A/61T14U15.EXE files, and a copy of this advisory notice and the hardware advisory notice (T0258) in PDF format.

Page 2 of 9 Step Action 4 Copy the FLASHTL.EXE (DRFaa20724) and VGNDTERM.EXE (DRFaa21028) to your Vanguide installation directory, C:\Vanguard\VANGUIDE. You will get a Windows message asking you to confirm the replacement of the existing files, click yes. Not mandatory in installing the patch. Required if the node has both Quad Voice, and FT1/E1 cards or requires datacapture from the terminal. 5 Run or open the V61T14A.EXE executable file from your local drive. 6 The patch executable file prompts you with installation instructions. Insert the Vanguide 6.1.R000 CD-ROM into the CD-ROM drive and select its drive letter. Follow the installation instructions provided by the installer. 7 Mandatory: Before unlocking the following files (which contain the default images) copy them as follows: From C:\V61T14A\7310\R61PT14A\61T14T11.EXE to C:\VANGUARD\SFW_IMGS\7310\R61PT14A\61T14T11.EXE From C:\V61T14A\7310\R61PT14A\61T14T12.EXE to C:\VANGUARD\SFW_IMGS\7310\R61PT14A\61T14T12.EXE From C:\V61T14A\7310\R61PT14A\61T14T15.EXE to C:\VANGUARD\SFW_IMGS\7310\R61PT14A\61T14T15.EXE From C:\V61T14A\7330\R61PT14A\61T14U11.EXE to C:\VANGUARD\SFW_IMGS\7330\R61PT14A\61T14U11.EXE From C:\V61T14A\7330\R61PT14A\61T14U12.EXE to C:\VANGUARD\SFW_IMGS\7330\R61PT14A\61T14U12.EXE From C:\V61T14A\7330\R61PT14A\61T14U15.EXE to C:\VANGUARD\SFW_IMGS\7330\R61PT14A\61T14U15.EXE Before loading the default software images, you must unlock the images by double click on the UNLOCK.EXE utility. You will be prompted to enter the serial number provided with the 6.1.R000 software license. For more detailed patch installation instructions, refer to the Vanguard Software Builder Manual (Part T0030).

Page 3 of 9 Build an Image After you install the patch executable file, you must build a custom release and load the custom image. This table provides general instructions for these procedures: Step Action 1 Using Vanguard Software Builder, build a custom 6.1.R000 patch image by selecting the appropriate patch (6.1.T14A for example) from the drop-down menu. Select features or options that you want to include in the image. 2 Load the custom image using the Vanguard Software Loader. For detailed instructions on building a software image and using the Vanguard Software Loader, see the Vanguard Software Builder Manual (Part T0030) and the Vanguard Software Loader Manual (Part T0057). Viewing Alarms and Reports Vanguard 7300 CPU Card Upgrade Checking the Part Label Alarms and Reports appear in the CTP or in your network management system. For explanations of Vanguard alarms and fatal error reports (FERs), see the Vanguard Alarms and Reports Manual (Part T0005). The Vanguard 7300 Series MCP750 (part number 75836G02) system cards are supported by software releases 6.1.T14A and greater. If you have a part number 75836G02 system card and are running older versions of release 6.1, a new 6.1 software patch is required (6.1.T14A). The system cards have a different revision PCI-PCI bridge than previous system cards (part number 75836G01). The new system cards are not being recognized by software older than 6.1.T14A. Software patch 6.1.T14A must be installed when using part number 75836G02. Figure 1 shows the revision label, located on the side of the unit. Figure 1. Part Label

Page 4 of 9 S6.1.S100 New Enhancements Vanguard 6435 and 6455 Voice Switching Table Entry Increase An increase to the voice switching table entries from 3,000 to 6,000 on the Vanguard 6435/6455 is available with Service Pak 6.1.S100 and greater software. (DRFaa20092) Save your CMEM before configuring a large number of entries. If your CMEM becomes too large, you might not be able to save it. (DRCaa23348) All Vanguards - Software Images Using TFTP With Service Pak 6.1.S100 and greater software images, Vanguard Routers may now act as a TFTP server for CMEM and software image transfers. Using TFTP software on a PC, users may now upload the software image the node is currently running to the PC. Another aspect of the feature is a node to node download mechanism, where a single server node can download CMEM and software images to multiple client nodes (up to ten). (DRFaa20656) When using a TFTP application to connect to a Vanguard Router running release 6.0.R00A or greater software through its WAN link, use the WAN address instead of the internal or LAN address. (DRFaa21052) For more information regarding the Vanguard TFTP Server, access the Vanguard Managed Solutions Product Documentation web site at: http://www.vanguardms.com/documentation The Vanguard TFTP Server document is listed under Operating Software Documentation. 6.2 and greater will include TFTP Server information in the Installation and Coldloading Manual (Part T0028).

Page 5 of 9 Patch 6.1.T14A s and Software Improvements Overview The table below lists change requests and software improvements. requests reported to Customer Service have an assigned change request number, and, in most cases, interim patches are released to fix the problems. These change requests and software improvements are incorporated into the Vanguard Applications Ware 6.1.R000 Patch 6.1.T14A, and, where applicable, interim patch releases have been replaced by the 6.1.R000 Patch 6.1.T14A: The and are numbers assigned by Vanguard Managed Solutions and are used exclusively for tracking purposes. Replaced by 6.1 Patch 6.1.T14A Description 11891 DRFaa21244 6.1R000 6.1.T14A Vanguard 7300 Series MCP750 system cards, part number 75836G02 requires 6.1.T14A or greater software to run.

Page 6 of 9 Service Pak 6.1.S100 s and Software Improvements Overview The table below lists change requests and software improvements. requests reported to Customer Service have an assigned change request number, and, in most cases, interim patches are released to fix the problems. These change requests and software improvements are incorporated into the Vanguard Applications Ware 6.1.R000 Service Pak 1 (6.1.S100), and, where applicable, interim patch releases have been replaced by the 6.1.R000 Service Pak 6.1.S100: The and are numbers assigned by Vanguard Managed Solutions and are used exclusively for tracking purposes. Replaced by 6.1 Service Pak 6.1.S100 Description DRCaa227546.0iR00A 6.1.S100 All Vanguards - Central Voice Switching Table entry numbers display wrong in the statistics if blank entries exist. DRCaa23101 6.0tR00E 6.2.R000 Vanguard 340 4FXO Input TLP range is not capable of an input level of over 1.0db. DRCaa23318 6.1.R000 Vanguard 7300 Series error occurs, port init failure due to AMI with 56K, not valid. DRCaa23321 6.2iR00D Vanguard 7300 Series VPMT statistics show a disconnected state for voice bypass DSO s mapped. DRFaa20820 6.1R000 Vanguard 6455 Quad FXS fails off-line diagnostics when using a Revision E silabs 3210 SLIC device. DRFaa20945 6.1iS10B Vanguard 340 TFTP server image copy function does not work with ETH port IP. 11134 DRFaa18688 5.6.T16A 5.6.T44B Vanguard 6455 Voice ports failing. Voice channels lock up and a node boot is needed to recover. 11368 DRFaa19648 5.6.T2JA 5.6.T4FC Vanguard 6400 Series voice problems due to random noise on the line and unclear voice calls. 11378 DRFaa19683 5.6.T2GB 5.6.T4FB Vanguard 6560, 6400 Series FAX connection is failing on FAX machines with a NSF record longer than 30 bytes.

Page 7 of 9 11482 DRFaa19923 5.6.T44A 6.0.T1PA Vanguard 320 if a call is generated from a ISDN remote end, the port does not send a Call Proceeding message to the remote end. 11483 DRFaa19924 5.6.T44A 6.0.T1PA Vanguard 320 is unable to receive calls due to incorrect filtering of the ISDN IEs. 11515 DRFaa20092 5.5.T2IA Voice switching table entries need to be increased from 3,000 on the Vanguard 6435/6455. 11519 DRFaa20099 6.0.R00A 6.0.T1PA Vanguard 6400 Series echo canceller is not working properly on the 4-port FXO cards. 11523 DRFaa20107 6.0.R00A 5.6.T4JA Vanguard 6400 Series when NAT transfers the RIP V2 routes, it uses the routes network mask. It should use the routes subnet mask. 11534 DRFaa20141 5.6.R000 5.6.T4NA Fax transmission is not working correctly from PSTN to PBX over the E1 Vanguard 6455 to a FXS port (directly connected on the same node). 11567 11571 DRFaa20174 DRFaa20181 5.6.T44C 5.6.T2GA 5.6.T4FA 5.6.T4FA Vanguard 6400 voice calls passing from the central site to the remote site are getting disconnected with PRI cause code 47. 11578 DRFaa20202 6.0.P02A 6.0.T19C Vanguard 7300 Series is receiving table overflow errors and the router needs to be rebooted. 11584 DRFaa20241 6.0.R00A 6.0.T14A Vanguard 7300 Series voice port hangs in the IDLE_CON state. 11656 11657 DRFaa20489 DRFaa20490 6.0.S100 6.0.S100 Replaced by 6.1 Service Pak 6.1.S100 Description (continued) Vanguard 6400 Series node crashes with a Program Exception Encountered error. 11654DRFaa20503 6.0.T16A 6.0.T1MA A Vanguard 6400 block size greater than 2046 cannot cross TPA-X.25 to TPA-TCP. TPA-TCP locks up and needs to be rebooted. 11671 DRFaa20546 5.6.T16E 6.0.T1PA Vanguard 6400 node crashes frequently when processing digital voice traffic.

Page 8 of 9 11482 DRFaa19923 5.6.T44A 6.0.T1PA Vanguard 320 if a call is generated from a ISDN remote end, the port does not send a Call Proceeding message to the remote end. 11483 DRFaa19924 5.6.T44A 6.0.T1PA Vanguard 320 is unable to receive calls due to incorrect filtering of the ISDN IEs. 11515 DRFaa20092 5.5.T2IA Voice switching table entries need to be increased from 3,000 on the Vanguard 6435/6455. 11519 DRFaa20099 6.0.R00A 6.0.T1PA Vanguard 6400 Series echo canceller is not working properly on the 4-port FXO cards. 11523 DRFaa20107 6.0.R00A 5.6.T4JA Vanguard 6400 Series when NAT transfers the RIP V2 routes, it uses the routes network mask. It should use the routes subnet mask. 11534 DRFaa20141 5.6.R000 5.6.T4NA Fax transmission is not working correctly from PSTN to PBX over the E1 Vanguard 6455 to a FXS port (directly connected on the same node). 11567 11571 DRFaa20174 DRFaa20181 5.6.T44C 5.6.T2GA 5.6.T4FA 5.6.T4FA Vanguard 6400 voice calls passing from the central site to the remote site are getting disconnected with PRI cause code 47. 11578 DRFaa20202 6.0.P02A 6.0.T19C Vanguard 7300 Series is receiving table overflow errors and the router needs to be rebooted. 11584 DRFaa20241 6.0.R00A 6.0.T14A Vanguard 7300 Series voice port hangs in the IDLE_CON state. 11656 11657 DRFaa20489 DRFaa20490 6.0.S100 6.0.S100 Replaced by 6.1 Service Pak 6.1.S100 Description (continued) Vanguard 6400 Series node crashes with a Program Exception Encountered error. 11654DRFaa20503 6.0.T16A 6.0.T1MA A Vanguard 6400 block size greater than 2046 cannot cross TPA-X.25 to TPA-TCP. TPA-TCP locks up and needs to be rebooted. 11671 DRFaa20546 5.6.T16E 6.0.T1PA Vanguard 6400 node crashes frequently when processing digital voice traffic.

Page 9 of 9 11673 DRFaa20585 6.0.T1EA 6.0.T1EB Vanguard 6400 problem installing dual E1 into slot two. When using transparent CCS for E1 in slot 2, then booting the TBOP port, E1 crashes. 11683 11723 11769 DRFaa20635 DRFaa20705 DRFaa20883 6.0.R00A 6.0.T1CA 6.0.T16C Replaced by 6.1 Service Pak 6.1.S100 6.0.T1CB Description (continued) Vanguard 340 node crashed with FAULT: Data TLB Miss Exception Encountered. 11734 DRFaa20724 6.1.R000 6.1.T01A Vanguard 340, 6435/6455 Software builder problems occur when Quad FXS/ FXO and FT1/FE1 features are selected. 11746 DRFaa20765 6.0.T1QA 6.0.T1QA Vanguard 6400 - when a 2780 TPAD and 2780 device bid for the line at the same time a NAK/ACK loop is generated. 11757 DRFaa20818 6.0.S100 Vanguard 340 lost CMEM due to attached modem with echo enabled. 11780 DRFaa20961 6.0.sp1 6.0.T1TA Vanguard 6455 QSIG E1 sending STATUS with cause 96 IE 18. 11782 DRFaa20925 6.0.T16C Vanguard 340 node crashed FER FAULT: Program Exception Encountered. 11783 DRFaa20958 6.1.R000 Vanguard 6400 BRI Dial on demand does not work in an French network. 11811 DRFaa21028 Vanguard Terminal does not capture data correctly.