Using Integration Utility

Similar documents
CiscoView 5.5 CHAPTER

Downloading Device Packages

Troubleshooting CiscoView

Downloading Device Packages

Installing Essentials

CiscoView CD Installation Instructions for Solaris and HP-UX

Manage the Capability Catalog in Cisco UCS Manager

Downloading Device Packages

CiscoView CD Installation Instructions

EMS Installation. Workstation Requirements CHAPTER. EMS Lite (Windows 95/98) EMS NT (Windows NT 4.0)

Upgrading Software and Firmware

Installation Procedures

Getting Started Using Cisco License Manager

Transport Gateway Installation / Registration / Configuration

Installing Essentials

Managing the Capability Catalog in Cisco UCS Manager

Downloading and Managing Firmware in Cisco UCS Central

Managing the Capability Catalog in Cisco UCS Manager

User Inputs for Installation

Cisco Unified Serviceability

Configuring and Managing WAAS Legacy Print Services

Troubleshooting the Installation

Release Notes for Cisco Video Surveillance High Definition IP Cameras, Release 1.4.1

Managing GSS Devices from the GUI

NNMi Integration User Guide for CiscoWorks Network Compliance Manager 1.6

Locating Users in the Network with User Tracking

INDEX. Bitmap Property dialog box, description 2-11

CiscoView CD Installation Instructions for AIX

Upgrading the Server Software

Configuring and Managing WAAS Print Services

Transport Gateway Installation / Registration / Configuration

LifeSize Control Installation Guide

Installing and Activating a Multi-User Network License for Statgraphics 18

User Tracking Utility

INDEX. Symbols. .cshrc file modifying 2-8.profile file modifying 2-8.rhosts file for RCP 5-17

Installing and Configuring Cisco Unified Real-Time Monitoring Tool

Xerox CentreWare for HP OpenView NNM Users Guide Version 1.5

Partner Integration Portal (PIP) Installation Guide

ehealth Integration for HP OpenView User Guide

Filr 3.3 Desktop Application Guide for Linux. December 2017

Symantec Desktop and Laptop Option 8.0 SP2. Symantec Desktop Agent for Mac. Getting Started Guide

ehealth SPECTRUM Integration

Firmware Management. Overview of Firmware. This chapter includes the following sections:

Data Manager Installation and Update Instructions

At the center of this process is a dedicated interface within the Ciena customer portal, which you use to manage and activate your licenses.

Security Management System Camera Configuration Axis IP Device (Stream Profile Support)

Procedure to Upgrade Verizon FiOS Router and Configure Xbox 360 to connect with Microsoft USB WiFi Adapter

Veritas Desktop and Laptop Option Mac Getting Started Guide

Upgrading your QuickBooks Company File Once per file only

Deploying Cisco Nexus Data Broker Embedded for OpenFlow

PictureTel. Utilizing PictureTel 330 NetConference SNMP Support with HP OpenView for UNIX

Installing and Configuring Cisco Unified Real-Time Monitoring Tool

Installation of Cisco Business Edition 6000H/M

System Setup. Accessing the Administration Interface CHAPTER

Managing WCS User Accounts

Fault Management. Overview of Polling and Thresholds CHAPTER

Enter your Appserv username and password to sign in to the Website

Xerox CentreWare for HP OpenView NNM User Guide. Version 1.1

Setting Up Essentials

Data Manager. Scheduling Data Backup CHAPTER

CA ehealth Integration for HP OpenView

Installation and Configuration Guide

Using NetShow Commands

Cisco recommends that you have knowledge of FireSIGHT Management Center, Sourcefire User Agent, and Active Directory.

ehealth SPECTRUM Integration

PathMATE Installation Guide

Brocade EFC Manager Software

Appserv Internal Desktop Access Mac OS Device with Safari Browser. Enter your Appserv username and password to sign in to the Website

Unified CCX Administration Web Interface

Configuration of trace and Log Central in RTMT

Lab - Configure Browser Settings in Windows 8

Fairfield University Using Xythos for File Storage

Windows Download & Installation

Micro Focus VisiBroker Installation Guide

Contents Upgrading BFInventory iii

Accessing Data from the Web Interface

eftp Application User Guide

Getting Started With the Cisco PAM Desktop Software

Smart Install in LMS CHAPTER

Administrator s Guide for the Polycom Video Control Application (VCA)

Enterprise License Manager User Guide, Release 9.1(1)

ECDS MDE 100XVB Installation Guide on ISR G2 UCS-E and VMWare vsphere Hypervisor (ESXi)

Veritas Desktop Agent for Mac Getting Started Guide

Manage Device Software Images

Managing Software. Upgrading the Controller Software. Considerations for Upgrading Controller Software

Upgrading the Cisco ONS CL to Release 7.0

LiveNX Upgrade Guide from v5.2.0 to v5.2.1

EntraPass (W10) Installation Guide Kantech-OnBoard systems

HP ProLiant Agentless Management Pack (v 3.2) for Microsoft System Center User Guide

Deploying Cisco UCS Central

Premium Pro Enterprise Local Installation Guide for Database Installation on a desktop PC (Cloudscape)

Dealing with Event Viewer

Installing the Operating System or Hypervisor

Joomla Installer User Guide. Version 1.0

IHS Markit Software Installation and Licensing Manual

For Trace and Log Central to work, you must resolve DNS lookup for all nodes in the cluster on the client machine.

Remote Access Installation

Copyright and Legal Disclaimers

Using the Prime Performance Manager Web Interface

Audit Reports. Change Audit Reports CHAPTER

Transcription:

CHAPTER 3 CiscoWorks Integration Utility downloads Network Management Integration Data Bundle (NMIDB) and integrates LAN Management Solutions (LMS) applications, icons, MIBs, and traps with third-party Network Management Systems (NMS). This chapter contains: Starting Integration Utility Downloading Data Bundle Integrating LMS Applications to NMS Updating NMS Troubleshooting Integration Utility Starting Integration Utility You must start Integration Utility to: Download and upgrade to a new NMIDB version available on Cisco.com. Change your LMS application server location. Register a new application. Change the NMS with which you want to integrate your LMS applications. Get a new vendor adapter script. You must log in as root on UNIX or have administrator privileges on Windows to run Integration Utility. This section contains: Starting Integration Utility on UNIX Starting Integration Utility on Windows Starting Integration Utility on NMS 3-1

Starting Integration Utility Chapter 3 Starting Integration Utility on UNIX To start Integration Utility on UNIX: Step 3 Step 4 Open a connection to the system on which Integration utility is installed using Telnet. Log in as root. Navigate to the root_ installation_directory/bin directory. If you plan to start the utility without using any options, set your Display environment variable. Enter the following (including any options from Table 3-1) on the command line:./nmic.sh Table 3-1 Command Line Options Command Line Option Description -h or -help Displays the command line options and usage. -v Displays the Integration Utility version and the NMIDB version. -q Runs in quiet mode without showing the GUI screens. Uses the NMIDB that was installed earlier and runs the adapter script that was configured earlier. -u Removes the integration information from the Network Management System. The menu entries for Cisco applications are removed but the MIBs and icons are not deleted. -q -cco Gets the latest NMIDB from Cisco.com and runs the adapter script that was configured earlier. -q -file Installs the NMIDB in quiet mode using the NMIDB file. Enter the full directory path to the NMIDB file. For example: On Windows, enter: -q -file C:\temp\nmidb.xxx where xxx is the NMIDB version. On UNIX, enter: -q -file /tmp/nmidb.xxx where xxx is the NMIDB version. Starting Integration Utility on Windows From a Windows platform, you can start Integration Utility from either: Start menu Or Command line 3-2

Chapter 3 Downloading Data Bundle To start Integration Utility from the Start menu: Click Start on your Windows desktop. Select Programs > CiscoWorks > Change Integration Options. To start Integration Utility from the command line: Navigate to the root_install_directory\bin directory. Enter the following (including any options from Table 3-1) on the command line: nmic.exe Starting Integration Utility on NMS If Integration Utility is integrated with the NMS, select Change Integration Options from the appropriate top-level menu. Downloading Data Bundle A Network Management Integration Data Bundle (NMIDB) contains all the information required to add Cisco devices to a Network Management System (NMS). The NMIDB version shipped with LAN Management Solution 3.0 is 1.085. The bundle is updated frequently, and you must install the latest version to use your NMS with LMS applications. When you upgrade device support, a new NMIDB is often downloaded. If Integration Utility detects a later version of the NMIDB, it prompts you to install it. You can also manually retrieve the latest NMIDB from a file on your local machine, from Cisco.com, or from another system. If Integration Utility has already been integrated into your NMS, you can download the data bundle from the Update Cisco Device Support menu. Select Update Cisco Device Support from the appropriate top-level menu. The location of the menu depends on where CiscoView applications have been installed on your system. The new NMIDB is automatically retrieved and integrated into the NMS. You must log in as root on UNIX or have administrator privileges on Windows to run Integration Utility. 3-3

Downloading Data Bundle Chapter 3 To download the data bundle: Start Integration Utility. The utility checks for a new (later version) NMIDB downloaded by the Software Center. If it finds a later NMIDB, a dialog box appears, prompting you to update to the later version. Click Yes if you want to install the new NMIDB. Click No if you do not want to use the new NMIDB downloaded by the Software Center. If you do not install the new NMIDB, you are prompted to install it each time you start Integration Utility until a later version is installed. If a new NMIDB was not detected or you clicked No, select one of these options from Table 3-2. Table 3-2 NMIDB Download Options Option Purpose Enter File Install the NMIDB from a file Enter the full directory path and the NMIDB file on your local machine. name. For example: On Windows, enter: C:\temp\nmidb.xxx where xxx is the NMIDB version. On UNIX, enter: /tmp/nmidb.xxx Cisco.com FTP Install the NMIDB from Cisco.com. Install the NMIDB from another system. Or where xxx is the NMIDB version. Click Browse to search for the NMIDB file. Enter your Cisco.com username and password. You must have Cisco.com login privileges. If you do not have a user account and password on Cisco.com, contact your channel partner or enter a request on the web site (http://www.cisco.com). Enter the device login information: System name User name User password Full directory path and the NMIDB file name (for example, /tmp/nmidb.xxx). Click Get NMIDB. The NMIDB is installed if it is a version later than the version of the NMIDB already installed on your system. 3-4

Chapter 3 Integrating LMS Applications to NMS Step 3 Click Next. If you made changes to any fields in this dialog box, you are prompted to confirm whether you want to get the NMIDB from the new location. Click Yes to install the new NMIDB. The NMIDB is installed if it is a version later than the version of the NMIDB already installed on your system. Click No to cancel your changes. The Application Registration dialog box appears. See Integrating LMS Applications to NMS for integration details. Integrating LMS Applications to NMS Use the Application Integration dialog box to select the applications you want to integrate into NMS. Integrating an application allows you to launch that application from an icon or menu in your NMS. Before you register applications with the NMS, you must complete downloading the data bundle for this device. If you do not download the data bundle, Integration utility uses the already installed NMIDB. To integrate LMS applications to your NMS: Step 3 Step 4 Select an application tab. There is one tab for each available application. If you are updating NMIDB for new device support only and do not need to make any application registration changes, skip the following steps and click Next. To designate a default application that launches from the NMS, check the Set as default application to be launched from NMS. Some Network Management System adapters do not support this option. Double-click the device icon on the NMS map after integration completes. Change the registration parameters as follows: To register web-based applications, enter or select: HTTP/HTTPS protocol. CiscoWorks web server hostname or IP address. CiscoWorks web server port number. Browser executable with the full path to launch the application. To register another application, select another application tab. Click Next after completing the registration process for all applications. If you made any application registration updates, a confirmation dialog box prompts you to save or cancel your changes. Click Yes to save your changes. Click No to cancel your changes. The Choose Adapters dialog box appears. 3-5

Integrating LMS Applications to NMS Chapter 3 Step 5 Select an adapter from the list of Available adapters in the Choose Adapters dialog box. The adapters that are available, by default, with Integration Utility are: CA-Unicenter HitachiNMMAdapter NetView60NTClientAdapter NetView60NTServerAdapter NetViewNTClientAdapter NetViewNTServerAdapter NNMAdapter Note NNM Adapter is also known as HP OpenView Network Node Manager Adapter. Step 6 SPECTRUMAdapter SystemWalkerAdapter You can also get new adapters from a file or from a remote FTP server and add them to the list of existing adapters. See Updating NMS for more information. Click Integrate to integrate the LMS application with the selected NMS. The integration may take some time. You should wait for the integration to complete successfully. Figure 3-1, displays HPOV after integration with CiscoView. 3-6

Chapter 3 Integrating LMS Applications to NMS Figure 3-1 HPOV After Integration With CiscoView 1 LMS Application (CiscoView) 2 Cisco Alarms-appearing after integration 3 HPOV Panner 4 Cisco Icon 3-7

Updating NMS Chapter 3 Updating NMS You can update or change the Network Management System (NMS) with which you integrate your LMS applications. For example, you can upgrade from HP Network Node Manager 6.4 to 7.0 or you can use another NMS. To preserve the integration with LMS applications, you must acquire a new adapter script. Adapter scripts integrate icons, MIBs, and applications from the NMIDB into the NMS. Before you run the adapter script to integrate your LMS applications, make sure the NMS for that script is available. To update your NMS: Select an adapter script from the Available Adapters list. You can select an adapter script from the list of NMS adapters provided with the Integration Utility or use an adapter script provided by the NMS vendor. When you select a script from the Available Adapters list, a description of that script appears in the Adapter Description dialog box. To add an adapter script to the list: a. Click Add... The Get New Adapter dialog box appears. b. Select one of these options from Table 3-3 Table 3-3 Options for Installing Adapter Script Options Purpose Enter File Install the Enter the full directory path and the adapter script file name. For example: adapter script On Windows, enter: from a file on your local C:\temp\adapter.xxx machine. where adapter is the name of the NMS adapter and xxx is the filename extension of the adapter. FTP Install the adapter script from another system. Or On UNIX, enter: /tmp/adapter.xxx where adapter is the name of the NMS adapter and xxx is the filename extension of the adapter. Click Browse to search for the adapter script file. Enter the following device login information: System name User name User password Full directory path and the adapter script file name. For example, /tmp/adapter.xxx where adapter is the name of the NMS adapter and xxx is the filename extension of the adapter. 3-8

Chapter 3 Troubleshooting Integration Utility c. Navigate to the directory that contains the new adapter script and select the file. d. Click OK. The script is added to the Available Adapters list. Click Integrate to run the selected script. The adapter script integrates the icons, MIBs, and applications into the NMS. Troubleshooting Integration Utility Use the suggestions in the Troubleshooting Suggestions Table 3-4 to resolve errors or other problems you encounter while using Integration Utility. Table 3-4 Troubleshooting Suggestions Symptom Probable Cause Possible Solutions Invoking NMIC displays error messages while extracting NMIDB. Cannot display specific Cisco device icons with adapter 1.7 for HP Network Node Manager. After Integration, traps are not properly integrated. After integration, when you run Change Integration Options, your system extracts NMIDB. If there is not enough disk space to extract NMIDB, the extraction fails. This happens when the NMIDB used for integration does not have the specific device icon information. This happens when the appropriate NMS Adapter is not being used. Free up some disk space and re-launch Change Integration Options. On Windows, make sure you have at least 190 MB of free disk space. For other file and operating systems, make sure you have at least 25 MB of free disk space. You can extract the latest NMIDB from Cisco.com using the Change Integration Utility GUI and perform the integration. Download the latest adapter version from Cisco.com for the specific NMS. 3-9

Troubleshooting Integration Utility Chapter 3 3-10