QS7800B Network Interface ControlBus Module for Multi-Dropping 7800 SERIES Relay Modules

Similar documents
QS7800A Network Interface ControlBus Module for 7800 SERIES Relay Modules

SYSNet QS7700A Network Interface ControlBus Module for BCS7700

7800 SERIES S7810B Multi-Drop Switch Module

M6410A, M7410F Small Individual Room Controller (IRC) Electric Linear Valve Actuators

SLATE. Digital I/O Module INSTALLATION INSTRUCTIONS R8001D4001

User Guide CPSMP VAC Power Supply Module: PointSystem CPSMC Accessory CPSMC Accessory. Contents.

PC Media Converter, Switching (TP-TX/FX)

A7800A1010 Tester for the 7800 SERIES System With Valve Proving Systems

Copyright Black Box Corporation. All rights reserved Park Drive Lawrence, PA Fax

1.0 Description. 2.0 Unpacking. 3.0 Installation

INSTALLATION INSTRUCTIONS

RS-232/RS-422 Optical Isolator

FIBER OPTIC A/B/C/D SWITCH (NON-LATCHING)

FIBER OPTIC A/B/C/D SWITCH (LATCHING)

Installation Guide. Wyse Rx0L Thin Client Flash and RAM Upgrade Option Kit. Issue: PN: L Rev. A

NSD/M1 Installation Instructions

CHS 7Ci. Bluetooth Cordless Barcode Scanner. Quick Start Guide

USB USB Data Transfer

User s Guide CPSMC0200-2x0 Dual-Slot PointSystem Chassis

Quick Start Installation Guide

DRD-4 DRD-4 JULY 1992 FX140A CUSTOMER SUPPORT INFORMATION

About the LAN Extenders Warranty Federal Communication Commission Radio Frequency Interference Statement Getting to Know the LAN Extenders The LEDs

RS-232 HS4 JANUARY 1997 IC131C CUSTOMER SUPPORT INFORMATION

10/100 Autosensing PC Media Converter

Verify Package Contents

Allworx Tx 92/24 Telephone Expander Installation Guide

rcc.1081 Installation Instructions

Four Port RS-232 Serial Interface

S7999D SOLA Operator Interface Display

Cat. No KT/B. Installation Data

NCH-1000 (Multiple Breaker Types) Installation Instructions

3174/3274 I-Mux FEBRUARY 1993 MX330A-C MX330A-D CUSTOMER SUPPORT INFORMATION

Start Here. Features. Model DS108 Dual Speed Hub Installation Giude

T1 Fold (2KM) SEPTEMBER 1995 MT612A-ST MT612AE-ST. T1 - Fold CUSTOMER SUPPORT INFORMATION

T775S Series 2000 Expansion Module

Infosystem Remote Touchscreen Installation Instructions

3M RFID Tracking Pad Model 770

Connectivity Peripherals User s Guide. Point 510 Point 1600

Rack Input Module Installation Instructions

BEETLE MSR Module. Swipe Card Reader. for BA7x. User Guide

SCSI Fiber Optic Extender

Installation Guide AVA-2902E/I. PCI-to-Fast SCSI Host Adapters. PCI SCSI Host Adapter with Internal or External Connector

2DScan TM Barcode Scanner

PETROL (P-SERIES), TTL, INSERTION READER TECHNICAL REFERENCE MANUAL

MONOPRICE. ShowPony 12-Watt LED Derby FX Light (RGBW) User's Manual P/N

Installation- and Operating instructions for CU Ethernet Controller with USB Input. Version: 1.4 Date:

Monarch 9414 Printer. TC9414EM 7/99 Rev. AB 1999 Monarch Marking Systems, Inc. All rights reserved.

Installer/User Guide

INSTALLATION GUIDE ADAPTEC SCSI CARD ULTRA160 SCSI CONTROLLER

BEETLE /Fusion Compact. Installation Guide

Mobile UHF Reader. Quick Guide. For full user s manual, please contact your local distributor. Mobile UHF Reader Quick Guide (Rev2) P/N:

AT IEEE 802.3af Universal Multi-voltage PoE Splitter. Installation and User Guide. PN Rev A

This document will show you how to set up the Hotwire 6205 ADSL Modem, and how to customize its configuration to get the most out of this product.

Support for Non-Ultra2 SCSI Devices

International Headquarters

Installing the ipower 70 Room Camera

Unpack the package contents and verify that you have the following: Model PA301 Network Card Telephone cable (10 ft) Resource CD

Computertop TV-I. Computertop TV-I SEPTEMBER 1993 AC451A CUSTOMER SUPPORT INFORMATION

HomePro ZRF113. Z-Wave Radio Frequency (RF) Controlled, 120 VAC, Isolated Contact Fixture Module, Series 200, Release 2.2

FX-DIS1710 Local Controller Display Installation Instructions Part No , Rev. B Issued April 2016

68-pin Internal Ultra160-LVD Connector. Adaptec SCSI Card 29160N

Mini Wireless Barcode Reader Quick Guide

H7625B; H7635B,C; H7655B Duct-Mount and Outdoor-Mount Humidity/Temperature Sensors

Installation Manual PDR GB Disk Drive Upgrade

ENCL-MZ800-WAL ENCL-MX800-PAN MNL TAC I/A Series MicroNet MN 800 Series Controller Installation Instructions. Application.

DB9 Microdriver CUSTOMER SUPPORT INFORMATION JULY 1994 ME792A ME793A ME794A

INSTALLATION GUIDE ADAPTEC SCSI CARD 29320LP

EPSON. Interface Card for LocalTaIk C82312* English Deutsch Français Español Italiano CO1-00

ADL-100 Operator s Manual

Dual Port RS-232 Serial Interface

Installation Guide for. PCC Premier Precision Camera Controller. Document Rev. C

HDMI and USB KVM Extender

H7625A, H7635A Humidity/Temperature Sensors

SB Channel Soundbar with Built-in Subwoofer

3M Wrist Strap and Ground Monitor 773. User s Guide

Model Bulk Sampling Scale. User s Manual

ESA SERIES ELECTRONIC BALANCE

DSU 5600 Data Service Unit USER MANUAL

SIGA-CC1/CC2 Signal Modules SIGA-MCC1/MCC2 Signal Modules

Keyboard Display Unit

SAFETY WARNINGS AND GUIDELINES

and Network Interface Modules Installation Instructions

IE-MediaChassis/1. Operation Manual

FRG-3105 Series Residential Gateway

Clipsal Bus Couplers. Two Channel (SLC5102BCLEDL) and Four Channel (SLC5104BCL) for Use with C-Bus Wired Systems

adynamo Technical Reference Manual PART NUMBER October 2014

Instruction Manual. Profile Family CD-ROM. Tektronix, Inc. PO Box 1000 Wilsonville, OR USA (USA and Canada)

The 1784-KR is a half-slot module that resides in any available expansion slot in an IBM XT (except slot J8) or AT compatible computer.

Operator s Handbook. Monarch FreshMarx 9417 Food Freshness System. TC9417OH Rev. AE 1/ Avery Dennison Corp. All rights reserved.

Personal MiniHub. Personal MiniHub RX LINKPORT #AUI PORT 5 UP LINK PWR JUNE 2001 LE2650A LE2650AE CUSTOMER SUPPORT INFORMATION

TELink FLASH. Model 700a. Installation and Operation Instructions. Magic On Hold is a Registered Service Mark and Trademark of Avaya Communications

Print Server Quick Installation Guide

onlinecomponents.com

Stacking Module. Installation Guide AT-MCF2000S. PN Rev A

888385_01 Install.book Page 1 Wednesday, November 11, :45 PM. SMDR6 Installation Guide

USER GUIDE. AXIS T8120 Midspan 15 W 1-port ENGLISH

CTS-iCPE Gateway Controller User s Manual Version: Revision B1

MONOPRICE. Blackbird 4K Pro 1x2 Ultra Slim HDMI Splitter. User's Manual P/N 21612

TWISTED PAIR DISTRIBUTOR KE 0108CH-DW. Instruction Manual. Thank you for your purchase of this product

Control different load types with one device

Transcription:

QS7800B Network Interface ControlBus Module for Multi-Dropping 7800 SERIES Relay Modules APPLICATION PRODUCT DATA The QS7800B Network Interface ControlBus Module allows remote monitoring and diagnostics of multi-dropped 7800 SERIES Relay Modules. FEATURES Up to six ControlBus Modules per Network Interface Unit. (Maximum of 222 multi-dropped subnetworks per Q7700 Network Interface Unit). Up to 31 multi-dropped 7800 SERIES subnetworks per QS7800B ControlBus Module without using an RS-485 repeater. Up to 61 multi-dropped 7800 SERIES subnetworks per QS7800B ControlBus Module using an RS-485 repeater. Local and remote annunciation of 7800 SERIES Relay Module faults. Personal computer user interface. Microsoft Windows based Combustion System Manager user interface. Modular construction. Contents Application... 1 Features... 1 Specifications... 2 Installation... 2 Ordering Information... 2 Wiring... 3 Building a Multi-Drop Network... 6 U.S. Registered Trademark Copyright 2002 Honeywell All Rights Reserved 65-0227- 2

SPECIFICATIONS Models: QS7800B1000 Network Interface ControlBus Module for use with the S7810B Multi-Drop Switch Module and Q7700A1014 and Q7700B1004 Network Interface Unit. Electrical Ratings: ControlBus Communication. Current Draw: 75 ma. Electrical Connectors: ControlBus Three-Prong Electrical Connector. Environmental Ratings: Ambient Temperature: Operating: 32 F to 130 F (0 C to 54 C). Storage: -30 F to +150 F (-34 C to +66 C). Humidity: Operating 85 percent relative humidity, continuous, noncondensing. Vibration: Continuous 0.5G. Enclosure: NEMA 1. Dimensions: See Fig. 1. Weight: 8 oz (unpacked). Accessories: 221237/168 Cover Assembly, Q7700 Network Interface Unit. 221240/168 Cover Assembly, Q7700 Electrical Enclosure, Network Interface Unit. 202433 Slot Inserts, ControlBus Slots Base Unit. 200603 ControlBus Electrical Connector. Approvals: Underwriters Laboratories Inc: File No. MP268, Guide No. MCCZ2. Canadian Standards Association: LR80141. Federal Communications Commission: Part 15, Class A Emissions, Part 68. FCC: Registration Number HS2SJ-10735-DT-E. Canadian Department of Communication: CS-03, Certification Number 573-345A. IMPORTANT This equipment complies with the requirements in part 15 of FCC rules for a Class A computing device. Operation of this equipment in a residential area can cause unacceptable interference with radio and television reception that requires the operator to take whatever steps are necessary to correct interference. Warning: This equipment generates, uses, and can radiate radio frequency energy, and if not installed and used in accordance with the Instructions Manual, may cause interference with radio communication. It has been tested and found to comply with the limits for a Class A computing device pursuant to Subpart J of Part 15 of FCC Rules, which are designed to provide reasonable protection against such interference when operated in a commercial environment. Operation of this equipment in a residential area is likely to cause interference, in which case, user at their own expense will be required to take whatever measures may be required to correct the interference. Any unauthorized modification of this equipment may result in the revocation of the owner s authority to continue its operation. Canadian EMI: This digital apparatus does not exceed the Class A limits for radio noise emission from digital apparatus set out in the Radio Interference Regulations of the Canadian Department of Communications. Le présent appareil numérique n émet pas de bruits radioélectriques dépassant les limites applicables aux appareils numériques de la Classe A prescrites dans le Règlement sur le brouillage radioeléctrique édicté par le ministère des Communications du Canada. INSTALLATION When Installing this Product... 1. Read these instructions carefully. Failure to follow them could damage the product or cause a hazardous condition. 2. Check the ratings given in the instructions and on the product to make sure the product is suitable for your application. ORDERING INFORMATION When purchasing replacement and modernization products from your TRADELINE wholesaler or distributor, refer to the TRADELINE Catalog or price sheets for complete ordering number. If you have additional questions, need further information, or would like to comment on our products or services, please write or phone: 1. Your local Home and Building Control Sales Office (check white pages of your phone directory). 2. Home and Building Control Customer Relations Honeywell, 1885 Douglas Drive North Minneapolis, Minnesota 55422-4386 In Canada Honeywell Limited/Honeywell Limitée, 35 Dynamic Drive, Scarborough, Ontario M1V 4Z. International Sales and Service Offices in all principal cities of the world. Manufacturing in Australia, Canada, Finland, France, Germany, Japan, Mexico, Netherlands, Spain, Taiwan, United Kingdom, U.S.A. 65-0227 2 2

3. Installer must be a trained, experienced service technician. 4. Check out the product after installation, as provided in the Q7700 Network Interface Unit instructions, form 63-2278 and S7810B instructions, form 65-0228. 5. Make sure that only the manufacturer makes repairs. 6. If trouble develops, disconnect the equipment from the modem and determine the cause of the fault. Reconnect only when the problem is corrected. WARNING.Electrical Shock Hazard. Can cause severe injury, death or equipment damage. Disconnect power supply before beginning installation to prevent electrical shock and equipment damage. More than one power supply disconnection can be involved. Humidity Install the Network Interface Unit where the relative humidity never reaches the saturation point. The Network Interface Unit is designed to operate in an 85 percent relative humidity continuous noncondensing moisture environment. Condensing moisture can result in improper operation. Vibration Do not install the Network Interface Unit where it can be subjected to excessive vibration in excess of 0.5G continuous maximum vibration. Weather The Network Interface Unit is not designed to be weather tight. When installed outdoors, provide protection for the Network Interface Unit. Mounting the Network Interface Plug-in Card For installation dimensions, see Fig. 1. 1. Mount the ControlBus Module in the Network Interface Unit (see Fig. 2). Do not mount the Network Interface Unit with the Interface ControlBus Module edge connector slots facing down. 2. Insert the ControlBus Module with the electrical connector facing out from the Network Interface Unit. 3. Grasp the ControlBus Module and align the plug-in edge card with the connector in the bottom of the Network Interface Unit. 4. Firmly insert the ControlBus Module into the Network Interface Unit. 5. Select a location that can support the Network Interface Unit. Be sure to allow clearances for servicing, installing and removing the wiring compartment cover, Network Interface Unit cover, electrical connectors and ControlBus Modules. a. Allow for an additional 2-1/2 inches (64 mm) minimum below the Network Interface Unit for electrical connector installation. b. Allow for an additional 1-1/2 inches (38 mm) minimum on each side for electrical housing cover insertion and wiring. 6. Remove the ControlBus Module using the wire loop; grasp the ControlBus Module firmly and pull the module from the Network Interface Unit. WIRING Wiring Requirements WARNING Electrical Shock Hazard. Can cause severe injury, death or equipment damage. 1. Wiring must comply with all applicable codes, ordinances and regulations. 2. Refer to Fig. 6 for proper system wiring. 3. Do not plug or unplug any Network Interface Unit ControlBus Module or electrical connectors with the power on. Make sure that power is off to protect against equipment damage. 1. All wiring must comply with all applicable electrical codes, ordinances, and regulations. 2. Recommended wire size and type for ControlBus communication is shielded 22 AWG twisted pair cable (Belden 8723 or equivalent). Terminal identification numbers and letters are shown in Table 1. Table 1. QS7800B and S7810B Terminals and Identification. QS7800B Signal Terminals Multi-Drop Data+ a 7 Multi-Drop Data- b 8 Multi-Drop Ground c 6 S7810B Terminals 3. Wire Routing: a. Do not route the ControlBus cable in conduit with line voltage circuits. b. Do not route the ControlBus cable close to the ignition transformer. c. Route the ControlBus cable outside of conduit if properly supported and protected from damage. d. Route the ControlBus cable so that all devices are connected in a daisy chain configuration. See Fig. 6. 4. Maximum wire lengths can be 4000 ft (121 m) for the ControlBus RS-485 interface under ideal conditions. Procedure 1. Refer to Fig. 6 for proper wiring. 2. Be sure that power is removed from the control panel by opening the main disconnect before beginning wiring to the electrical connectors. More than one disconnection can be involved. 3. Select the location of the Network Interface Unit to be mounted: 3 65-0227 2

a. Near a phone line. b. Within 4000 ft (121 m) of all Relay Modules connected to the Network Interface Unit. c. Within 50 ft (15 m) of the personal computer connected to the 25-pin RS-232 port of the Network Interface Unit. 4. Mount the Network Interface Unit and insert the ControlBus Module into the Network Interface Unit slot, see Fig. 2 and 5. Route the ControlBus cable so that all devices are connected in a daisy chain configuration. It is recommended that the QS7800B ControlBus Module be at one end of the daisy chain. 5. Connect L1, L2 and Ground (GND) to the pigtails (Q7700A only). 6. Insert the plug-in cards into the open slots of the Network Interface Unit, starting with slot one. 7. Install the covers, power wiring compartment and Network Interface Unit. 8. Connect the serial port of the modem to the -pin RS-232 connector of the Network Interface Unit (see Fig 4).. Connect the serial port of the personal computer to the 25-pin RS-232C port on the Network Interface Unit for local personal computer application, see Fig. 3. 10. Do not exceed 600 ma current draw, six card maximum, total capacity of the plug-in cards. Refer to the ControlBus Module device label and this specification for individual loads. 11. Recheck all wiring with Fig. 6. 12. Restore power to the Network Interface Unit. 25-PIN RS-232C CONNECTOR Fig. 3. RS-232 Interface insertion (serial communications). NETWORK INTERFACE UNIT M7432B NETWORK INTERFACE UNIT CONTROLBUS PLUG-IN MODULE 3-2/32 () -PIN RS-232 CONNECTOR RS-232C CONNECTOR (SERIAL COMMUNICATIONS) M7433B 1 (25) 4-21/32 (118) M203 Fig. 4. Modem insertion, Network Interface Unit. Fig. 1. QS7800B Network Interface ControlBus Module dimensions in in. (mm). CONTROLBUS MODULE NETWORK INTERFACE UNIT CONTROLBUS MODULE ELECTRICAL CONNECTOR EDGE CONNECTOR CONTROLBUS RS-485 CONNECTOR NETWORK INTERFACE UNIT M7436B M7437B Fig. 5. ControlBus RS-485 interface insertion. Fig. 2. ControlBus Module mounting. 65-0227 2 4

NETWORK INTERFACE UNIT PLUG-IN PLUG-IN 10 UNIVERSAL POWER SUPPLY 2 A B C 3 5 SYSTEM 2 6 TO LOCAL SYSTEM 1 POWER SUPPLY L1 L2 GND 8 7 6 TO LOCAL SYSTEM 8 7 6 5 4 3 2 1 S7810B MULTI-DROP SWITCH MODULE 4 + GND INPUT OUTPUT 7 RS-485 REPEATER 8 7 6 5 4 3 2 1 S7810B MULTI-DROP SWITCH MODULE 7800 SERIES RELAY MODULE 7800 SERIES RELAY MODULE + GND 6 TO LOCAL SYSTEM 8 7 8 7 6 5 4 3 2 1 S7810B MULTI-DROP SWITCH MODULE 7800 SERIES RELAY MODULE 1 POWER SUPPLY. PROVIDE DISCONNECT MEANS AND OVERLOAD PROTECTION AS REQUIRED. Q7700A1014, 120V, 50/60 HZ; Q7700B1004, UNIVERSAL POWER SUPPLY, 100 TO 250V, 50/60 HZ. 2 CONNECT PIGTAIL LEADWIRES (Q7700A ONLY): BLACK L1 WHITE L2 GREEN GROUND 3 4 MULTI-DROP RS-485 COMMUNICATION BUS. UP TO 31 S7810B MULTI-DROP SWITCH MODULES (SUBNETWORKS) CAN BE CONNECTED TO A SINGLE QS7800B CONTROLBUS MODULE WITHOUT AN RS-485 REPEATER. UP TO 61 S7810B MULTI-DROP SWITCH MODULES (SUBNETWORKS) CAN BE CONNECTED TO A SINGLE QS7800B CONTROLBUS MODULE WITH AN RS-485 REPEATER. INSTALL THE REPEATER BETWEEN THE 30TH AND 31ST SUBNETWORKS. 5 UP TO SIX QS7800B CONTROLBUS MODULES CAN BE INTERFACED WITH THE NETWORK INTERFACE UNIT. MAXIMUM OF 222 MULTI-DROP SUBNETWORKS CAN BE INTERFACED WITH A SINGLE Q7700 NETWORK INTERFACE UNIT. 6 7 8 LOCAL SYSTEM (SUBNETWORK). REFER TO S7810B MULTI-DROP SWITCH MODULE INSTRUCTIONS, FORM 65-0228, FOR WIRING INSTRUCTIONS. THE SUBNETWORKS MUST BE WIRED IN A DAISY CHAIN CONFIGURATION. IT IS RECOMMENDED THAT THE QS7800B CONTROLBUS MODULE BE AT ONE END OF THE DAISY CHAIN. 22 AWG (OR LARGER) TWISTED PAIR SHIELDED CABLE (BELDEN 8723 OR EQUIVALENT) IS RECOMMENDED. CABLE SHIELD MUST BE GROUNDED AT EACH END. 10 MULTI-DROP COMMUNICATION BUS TERMINATION RESISTORS: A. WITHOUT RS-485 REPEATER: MODULES AT THE CLOSEST AND FARTHEST END OF THE DAISY CHAIN REQUIRE TERMINATION RESISTORS. INSTALL A 120 OHM, 1/4 WATT, RESISTOR BETWEEN TERMINALS a AND b of the QS7800B CONTROLBUS MODULE. INSTALL A 120 OHM, 1/4 WATT, RESISTOR BETWEEN TERMINALS 7 AND 8 OF THE LAST S7810B MULTI-DROP SWITCH MODULE IN THE DAISY CHAIN. B. WITH RS-485 REPEATER: WHEN AN RS-485 REPEATER IS USED, TWO DAISY CHAIN CONFIGURATIONS ARE EFFECTIVELY FORMED. MODULES AT THE CLOSEST AND FARTHEST END OF EACH DAISY CHAIN REQUIRE TERMINATION RESISTORS. INSTALL A 120 OHM, 1/4 WATT, RESISTOR BETWEEN TERMINALS a AND b OF THE QS7800B CONTROLBUS MODULE. INSTALL A 120 OHM, 1/4 WATT, RESISTOR BETWEEN INPUT TERMINALS DATA+ AND DATA- OF THE RS-485 REPEATER. INSTALL A 120 OHM, 1/4 WATT, RESISTOR BETWEEN OUTPUT TERMINALS DATA+ AND DATA- OF THE RS-485 REPEATER. INSTALL A 120 OHM, 1/4 WATT, RESISTOR BETWEEN TERMINALS 7 AND 8 OF THE LAST S7810B MULTI-DROP SWITCH MODULE IN THE SECOND DAISY CHAIN. FOR Q7700B NETWORK INTERFACE UNIT. Fig. 6. Multi-drop wiring. M11347A 5 65-0227 2

BUILDING A MULTI-DROP NETWORK Guidelines The subnetwork addressing in the Q7700 Network Interface Unit (NIU) is not contiguous. It is divided into two blocks, containing 18 and 24 addresses, respectively. A maximum multi-drop configuration would include 222 subnetworks (18 plus 24) on a single Q7700 NIU. Because the 24 subnetworks are not contiguous, connect them to a separate Q7700 NIU slot. One QS7800B ControlBus Module card supports up to 31 multi-drop subnetworks without using an RS-485 repeater. If an RS-485 repeater is used, up to 61 multi-drop subnetworks can be supported by one QS7800B card. The RS-485 repeater must be installed between the 30th and 31st subnetwork. Each subnetwork includes one 7800 SERIES controller with or without an S7800 Keyboard Display Module and/or an S7830 Expanded Annunciator. An S7810B1007 Multi-Drop Switch Module is required in each subnetwork. See Fig. 6 for wiring information. Subnetworks can be spread evenly (balanced) across the NIU slots. This will help to speed communications. It is recommended that the multi-drop network be built starting with slot number 1 of the NIU, according to the guidelines above. Record the serial number and physical location of each S7810B Multi-Drop Switch. This data will be useful when commissioning the ZM7850 Combustion System Manager (CSM) software. (Reference CSM manual, form 65-0102, for CSM commissioning.) Examples Network with Maximum of 18 Subnetworks: NIU Slot Numbers 1 2 3 4 5 6 Total Number of Subnetworks 61 61 61 15 Open Open 18 Subnetworks Balanced 33 33 33 33 33 33 18 The open NIU slots can be used for other QS7800 ControlBus Module Cards. Network with Maximum of 222 Subnetworks: NOTE: For networks that have more than 18 subnetworks, the last NIU card slot must have the 1th through 222nd subnetwork attached to it. NIU Slot Numbers 1 2 3 4 5 6 Total Number of Subnetworks 61 61 61 15 24 Open 222 Subnetworks Balanced 40 40 40 3 3 24 222 The open NIU slot can be used for other QS7800 ControlBus Module Cards. 65-0227 2 6

7 65-0227 2

Automation and Control Solutions Honeywell International Honeywell Europe S.A. Honeywell Latin American Honeywell Honeywell Limited-Honeywell Limitée Control Products 3 Avenue du Bourget Region 185 Douglas Drive North 35 Dynamic Drive Honeywell Building 1140 Brussels 480 Sawgrass Corporate Parkway Golden Valley, MN 55422 Scarborough, Ontario 17 Changi Business Park Central 1 Belgium Suite 200 M1V 4Z Singapore 486073 Sunrise FL 33325 65-0227 2 G.R. Rev. 01-02 Printed in U.S.A. on recycled paper containing at least 10% www.honeywell.com post-consumer paper fibers.