Z-Wave Power Reader. Product Manual NQ-9021-EU. From your Z-wave network directly to the cloud! INTRODUCTION

Similar documents
NorthQ Power Reader (NQ-9021) Technical Integration. Z-Wave Commands

Quick start: Panic Watch EU

AXIS T8341 PIR Motion Sensor. User Manual

DCH-122 PIR Motion Sensor

Quick start Energy Switch EU

SI-103. Flood Sensor. User Manual

Instruction Manual Power plug Model number: STW-W3350WU

Aeon Labs Dual Nano Switch

Aeon Labs Nano Switch

Adding to Z-Wave TM Network 1

smanos K2 Smart Hub Contents

Motion Sensor 2 with temperature sensor

Aeon Labs Water Sensor 6

PAN11-1B Smart energy plug in switch

SI in 1 Multi-sensor. User Manual

living connect, Z-Wave Certified Electronic Radiator

PAN11. Smart energy plug in switch

Quick start: Tag Reader EU

Please refer to the chapters below for detailed information about all aspects of the products usage.

Z-Wave Home Gateway. FG3200/FG2200 ( Z-Wave Home gateway )

2. Press Fn switch 3 times in a row again to exclude the device from Z-Wave network.

Z-Wave Dimmable LED Light Bulb

Adding to Z-Wave TM Network

EVR_SE812 Z-Wave Siren Firmware Version : 0.0

SI-102. PIR Motion Sensor. User Manual

F O R E S T S H U T T L E S / L Z - W

Please refer to the chapters below for detailed information about all aspects of the products usage.

ZME_MTEMP Temperature Sensor, Thermostat for Heating and Cooling and Binary Sensor Firmware Version : 2.1

AEO_SES3_EU Inline Smart Energy Switch. Quick Start. What is Z-Wave? Product description. Before Device is installed

Aeotec Multisensor Gen5 has been crafted to power connected lighting using Z-Wave Plus. It is powered by Aeotec s Gen5 technology.

EVR_SE812 Z-Wave Siren

PAN03 ; PAN10 Switch Module with meter

PACKAGE CONTENTS SPECIFICATIONS

Z-Wave British Standard Plug Dimmer

POP_ Z-Wave Schuko Plug-in Switch plus Power Meter Firmware Version : 1.1

OPERATING MANUAL. NanoMote Quad ZWA003-A/C

Z-Wave CO Detector. Product Description. Prepare for Installation / Reset Please read the user manual before installing the product.

Universal Z-Wave Key Pad

TWO SPDT Switch module with meter

Flood Sensor. Product Description. Prepare for Installation / Reset Please read the user manual before installing the product.

Wall Controller WALLC

WALL MOUNTED SWITCH MANUAL

EUR_STELLAZ Wall Radiator Thermostat Valve Control Firmware Version : 0.4

Rain Sensor. Quickstart. What is Z-Wave? Product Description. Prepare for Installation / Reset. Installation

Aeon Labs Nano Dimmer

Rain Sensor SKU: POPE700168

Adding to Z-Wave TM Network

Please refer to the chapters below for detailed information about all aspects of the products usage.

PAD02. Z-Wave Smart Dimmer Socket. Adding to Z- Wave TM Network

Operational Manual for ID Lock 101 with Z-Wave Module 01A

Electronic Solutions, Inc.

Software Design Specification Document SDS List of defined Z-Wave Command Classes.

Aeon Labs Dual Nano Switch

ZME_RC2 Z-Wave Remote Control

ZME_WCD2 Z-Wave Double Paddle Wall Controller DURO white

PAN04 In Wall Dual relay(1 way) switch module. Adding to Z-Wave TM Network

Universal Z-Wave Key Pad

User s Manual. Single phase electrical energy meter WM1 6 Single phase electrical energy meter WM1 6Z Single phase electrical energy meter WM1M6

PRODUCT DESCRIPTION PACKAGE CONTENTS

ZME_ Wall Controller Set for DUWI Everluxe

Adding to Z-Wave TM Network

Wireless Lighting Control ZRM-M80 Z-Wave Smart Plug (with switch and energy meter) USER MANUAL

Please refer to the chapters below for detailed information about all aspects of the products usage.

SMART WINDOW /DOOR CONTACT

PHI_PSP01 Z-Wave 3 in 1 Sensor(Motion, Illumination, Temperature)

Aeon Labs Micro Smart Dimmer (2nd Edition) (Z Wave Micro Smart Dimmer (2nd Edition))

PHI_PSM02 Z-Wave 4 in 1 Sensor(Door- /Window, PIR/Motion, Temperature, Illumination)

ID Lock ID Lock 150 User Reference Manual Rev 2.1

Aeon Labs Range Extender 6. (Z-Wave Range Extender)

POPE Z-Wave 10 Year Smoke Detector with Siren Function

Aeon Labs LED Bulb (Z-Wave LED Bulb)

LoRaWAN Pressure / Depth and Temperature Sensor

EUR_STELLAZ Wall Radiator Thermostat Valve Control

Aeon Labs Smart Switch 6 (Z-Wave Smart Switch 6)

AEO_HDS Heavy Duty Switch

EUR_STELLAZ Wall Radiator Thermostat Valve Control

SA-102. Smart In Wall Dual Switch. User Manual

LoRaWAN Pressure / Level and Temperature Sensor

Z-Wave.Me Key Chain Controller

PRODUCT DESCRIPTION PACKAGE CONTENTS

MIRRIN. Multi-Channel Load Logger MODEL: LL400 User Manual 1 GETTING STARTED INTRODUCTION CONNECTIONS

HRT4-ZW THERMOSTAT MANUAL Z-WAVE INFORMATION

QEES MyKey Online Manual

MCO Home Glass Touch Switch GEN5 (2 Buttons)

DPM Digital DC Power Meter with Data logging capability. User Manual

ZRC-90 (Scene Master) Operating Instructions

PHI_PAN06 Relay Insert 2 * 1.5 KW

Aeon Labs Doorbell Gen5 (Z Wave Doorbell Gen5)

SEC_SSR302 Z-Wave controlled Boiler Actuator - two channels

PACKAGE CONTENTS SPECIFICATIONS PRODUCT DIAGRAM

RMS Mini Wireless Data Logger

SES 302 and SES 303 Temperature & Humidity Sensor. User and Installation Instructions BGX

HOBO State Data Logger (UX90-001x) Manual

VIS_ZM1602 Wireless Siren - mainspowered

Aeon Labs LED Strip. (Z-Wave LED Strip)

Model IMP-22G2,H Low Cost Slave Clock Impulser Converts your slave clock to a working timepiece without modifying its original mechanism.

MULTIREG Z-WAVE SCENE CONTROLLER

Aeon Labs LED Bulb. (Z-Wave LED Bulb)

S05-SM User s Manual (ZigBee HA Profile) Ver. 1.02

Z-Wave 4-in-1 Multi Sensor HZS-300E/HZS-300A

Transcription:

Product Manual NQ-9021-EU Z-Wave Power Reader From your Z-wave network directly to the cloud! INTRODUCTION NorthQ Power has developed a samll Power Reader that can be easily installed on existing electronic or mechanical meters in order to visualize electricity consumption in private homes or office buildings. FEATURES Save up to 25% on your electricity bill Keep track of your electricity consumption Compatible with 98% of all power meters on the market Visualize current wattage consumption Locate power hungry appliances and eliminate standby power DESCRIPTION The NorthQ Power Reader can be installed on old or new electricity meters. It is basedon the Z-Wave wireless standard, ideal for home automation. Electricity data is transferred to a Z-Wave controller such as a NQ-901-EU Gateway or a NQ-920-EU USB Stick, every 15 minutes. NorthQ also provides an (OEM) version for system integrators so 3rd parties can integrate the Power Reader or other NorthQ products into their own system. Full API is available under NDA.

Technical Specifications NQ-9021-EU Z-Wave Power Reader From your Z-wave network directly to the cloud! Technical Specifications WIRELESS COMMUNICATION Frequency Range Meters Supported Wireless Connectivity 868.42 MHz EU Version 25~35 meters indoor 50~110 meters outdoor Mechanical (Ferraris Type) Electronic (LED) Electronic - Infrared LED Z-wave BUTTON OPERATION 1x 2x 3x 7x Wake-up Sleep Include mode (requires a learn mode command) Factory reset (Warning: all data will be deleted) BUTTON OPERATION Gateway NorthQ NQ-900-EU NorthQ NQ-901-EU NorthQ NQ-902-EU USB Stick Other Z-Wave Gateways NQ-920-EU

Technical Specifications NQ-9021-EU EXTRA SPECIFICATIONS Weatherproof Both sensor cable and main unit Cable Lengh 5 meters Storage Space About 3 months of consumption data (values every 15 minutes) Wall-Mount Accessories Included Firmware Update Wireless CERTIFICATES Z-Wave CE Certificates Certificated 88/387/EEC; 2004/108/EC; 2006/95/EC OPERATING CONDITIONS Operating Temperature 0 ~ 50ºC Range Operating Humidity 20 ~ 90% Range Storage Temperature -20 ~ 70ºC Range Storage Humidity Range 15 ~ 95% PRODUCT SIZE Sensor Head Main Unit 28.6 x 26.6 x 9.1 mm 93 x 75 x 34 mm

Technical Specifications NQ-9021-EU SUPPORTED COMMAND CLASSES COMMAND_CLASS_BASIC COMMAND_CLASS_BATTERY COMMAND_CLASS_WAKE_UP COMMAND_CLASS_FIRMWARE_UPDATE_MD_V2 COMMAND_CLASS_TIME_PARAMETERS COMMAND_CLASS_METER_V2 COMMAND_CLASS_CRC_16_ENCAP COMMAND_CLASS_CONFIGURATION COMMAND_CLASS_MANUFACTURER_SPECIFIC_V2 COMMAND_CLASS_VERSION COMMAND_CLASS_METER_TBL_MONITOR

NorthQ Power Reader (NQ-9021) Technical Integration Z-Wave Commands

Table of Contents Power Reader NQ-9021 Power Reader...1 Overall device information...2 General description...2 Command classes supported...2 Functionality of button...3 Detailed description of each command class...5 Basic command class... 5 Battery command class... 5 Configuration command class... 5 Firmware update command class... 7 Manufacturer specific command class... 7 Manufacturer specific command class... 7 Meter command class... 7 Time parameters command class... 7 Version command class... 7 Wakeup command class... 7 CRC16 encapsulation command class... 7 Appendix A Manufacturer Proprietary commands...8 Description...8 Format of Power Reader Manufacturer Proprietary commands...8 Commands...8 Calibration status report... 9 Calibration status get... 9

Overall device information Basic type: BASIC_TYPE_ROUTING_SLAVE Generic type : GENERIC_TYPE_METER Specific type : SPECIFIC_TYPE_SIMPLE_METER General description The basic purpose of the device is to count impulses / flashes from a metering device and to save impulse count in nonvolatile memory with 15 minutes interval. It's possible to retrieve the historical data saved in nvram using the Z-Wave AEC framework. The device supports remote firmware update. Note that doing remote firmware updates destroys all saved samples in the sensor. Command classes supported COMMAND_CLASS_BASIC COMMAND_CLASS_CRC16_ENCAP COMMAND_CLASS_WAKE_UP COMMAND_CLASS_MANUFACTURER_PROPRIETARY COMMAND_CLASS_VERSION COMMAND_CLASS_BATTERY COMMAND_CLASS_METER_V2 COMMAND_CLASS_METER_TBL_MONITOR COMMAND_CLASS_CONFIGURATION COMMAND_CLASS_FIRMWARE_UPDATE_MD_V2 COMMAND_CLASS_TIME_PARAMETERS Guide for Power Reader - Battery version When using the battery powered version of the Power Reader the registered consumption data from the power meter will be transferred every 15 minutes in order to optimize the battery performance. The wireless transmitter in the Power Reader is able to perform a variety of functions by pressing the grey sensor button, located in the bottom of transmitter:

The push button on the device works as described below: 1 press: Enter wakeup (real-time) mode + sends wakeup duration config report 2 presses: Exit wakeup mode ( go to normal mode) 3 presses: Send Node information frame + Enter inclusion/exclusion mode 5 presses: Start auto calibration (mechanical meters only) 7 presses: Reset to factory defaults ( Also clears Z-Wave associations) Normal Mode In normal mode the Power Reader will wakeup and transfer data to the controller every 15 minutes. This is done to maximize battery lifetime. Press the sensor button 1 time to enter Wakeup (real-time) mode If you wish to receive live data you can put the Power Reader into wakeup mode (real-time mode) and then receive power consumption every 5 seconds. By pressing the sensor button 1 time. - The LED will flash once and the Power Reader will enter wakeup mode (real-time) for approx. 15 min. After 15 minutes it will automatically revert to normal mode where data is transmitted every 15 minutes (see more info about normal mode below). NOTE: Be aware that battery life expectancy will be significantly reduced by frequent use of realtime mode. When sensor is in wakeup mode (real-time) the LED will flash every time a pulse has been detected/counted. Press the sensor button 2 times to Exit wakeup mode -> Normal mode The Power Reader operates normally by transferring the data collected from the wireless transmitter to the controller every 15 minutes - this is called Normal Mode. However, If the Power Reader has been put into Wakeup (Real-time) mode, it can be returned to Normal Mode by pressing two times on the sensor button. - The LED will flash twice and Power Reader will then again be transmitting data every 15 minutes. NB! In normal mode the sensor LED will not flash every time a pulse has been detected.

Inclusion Mode Press the sensor button 3 times to include the sensor To create a connection between the wireless transmitter and the controller, it is necessary to include the sensor using the inclusion function: First insure that the controller on the Z-wave network is set to inclusion mode - Press three times on the sensor button The LED will flash 3 times. Subsequently, the wireless transmitter will attempt to gain contact with the controller and include the device into the network. This is only needed the first time you want to add the device to the Z-Wave network. Exclusion Mode Press the sensor button 3 times to exclude the sensor To remove the connection between the wireless transmitter and the controller; it is necessary to exclude the sensor from the controller. First make sure that the controller on the Z-Wave network is set to exclusion mode. Then press three times on the sensor button The LED will flash 3 times. Subsequently, the wireless transmitter will attempt to gain contact with the controller and exclude the device from the Z-wave network. The Z-Wave standard allows products from different vendors and categories to work in conjunction as part of the same Z-Wave network, furthermore enabling the units to work as repeaters despite vendor origin. Press the sensor button 5 times - Calibration When mounting the Power Reader on a mechanical meter it is necessary to calibrate the sensor head to ensure a correct reading of consumption. Mount now the sensor on the meter and press 5 times on the sensor button to start the calibration. The LED will then start flashing to indicate that calibration has begun. The calibration takes approx. 5-10 minutes, and the LED will start to flash gradually in a slower pace while calibration is carried out. When calibration is completed the LED will turn off. Hereafter you will see the LED flash once each time the Power Reader will register a rotation/pulse from the meter. NOTE: If the LED does not turn off and begins to flash rapidly (instead of turning off) after the calibration has completed, this means that the Power Reader cannot make proper reading and you must therefore try to place the sensor head on a different position on the meter and repeat calibration one more time. If calibration is still unsuccessful you must try alternative mounting of the sensor e.g. by placing the sensor head on the side of the meter or place it vertically.

Press & hold the sensor button for 5 seconds. - Tuning Function In order to optimize the reading of consumption data from mechanical power meters, it may be necessary to make a final adjustment of the sensor head. Press & hold the sensor button for 5 seconds to begin the tuning function. NB! This function is normally not used. Press the sensor button 7 times RESET By pressing 7 times on the sensor button the system will make a complete RESET to factory default. The LED will flash 3 times and then become steady for approximately 5 seconds - then it will flash 3 times in a row and finally it will return with 3 more flashes to indicate that the sensor has been RESET. Detailed description of each command class Basic command class Implemented according to device class specification. BASIC_SET unsupported, BASIC_GET always returns a BASIC_REPORT with the value 0x1 (meter type) Battery command class Implemented according to command class specification. Value of 255 is not used for low battery reporting. (0-100 is reported from sensor) Configuration command class This class is used for setting certain vendor specific configuration variables. See the following table for configuration variables: Id Name Size Range Default value Description 0x01 Pulse factor 4 bytes 1 655350 10000 How many pulses*10 per kwh 0x02 Sensor type 1 byte 1 2 2 0 = Unconfigured 1 = Pulse meter 2 = Mechanical meter 0x03 IR Listen period 1 byte 0 127 0 Additional time for feedback measurement. Should always be 0.

Id Name Size Range Default value Description 0x04 IR Pulse Width 1 byte 0 127 50 Adjusts transmit signal so received signal will in average be equal to this values. Auto calibration might select another value than this. 0x05 Poll / Wake up frequency 1 byte 1 50 20 Wake device up this many times per second. This value also controls number of measurements per second on mechanical meters 0x06 Reserved 1 byte 1 127 (dynamic) Reserved 0x07 Reserved 1 byte 1 127 (dynamic) Reserved 0x08 Wake up interval 2 byte 1 32767 900 Do not use. Set this value using WAKE_UP_INTERVAL _SET instead. 0x09 Pulse count 4 bytes 0 (2^31)-1 0 Current pulse count in device (pulse count / pulse factor = kwh) 0x0A Keep alive period 2 bytes 0-32767 3*20 How many ticks before going back to sleep in normal wakeup mode. 0x0B Real-time mode 2 bytes 0 32767 0 (sleep mode) Set this to enter real-time mode from remote. Contains seconds * poll frequency before going back to sleep. If you press the button once this value will be set. 0x0C Serial number 4 bytes 0 (2^31)-1 (unique) Do not use. Use COMMAND_CLASS_M ANUFACTURER_SPECI FIC version 2 instead.

Firmware update command class Implemented according to command class specification. It is implemented in a way that does not require user attention (No button press needed). If you want to support firmware updates of Power Reader please contact NorthQ directly. Manufacturer specific command class Implemented according to command class specification. Manufacturer specific command class See Appendix A. Meter command class Implemented according to command class specification and according to the following information. Command class version 2 Scales supported Default scale (for version 1 support) kwh Meter Reset Command is not supported. Time parameters command class Implemented according to command class specification. If it is used for real time clock remember to always use UTC time. Version command class Implemented according to command class specification. Wakeup command class Implemented according to command class specification. (Version 1) CRC16 encapsulation command class Implemented according to command class specification.