Accessing the AXM-WEB at Admin level

Similar documents
Acuvim II Series Power Meter AXM-WEB-PUSH User's Manual

Acuvim II Series Power Meter SNMP Protocol User's Manual

GV-I/O Box 4E. Contents

Lab - Connect to a Router for the First Time

Description of options. user s manual. DEIF A/S Frisenborgvej 33 DK-7800 Skive Tel.: Fax:

Document Name: User Manual for SC10MK, Modbus RTU to Modbus TCP Converter

Plus-X I/O Units. Manual Supplement Configuring Units with and without DHCP

Contents. Table of Contents

1 Introduction Purpose of this Manual General Specifications Access Levels and Passwords Access and Passwords Addresses...

Click on Close button to close Network Connection Details. You are back to the Local Area Connection Status window.

I m InTouch Installation Guide for the DSL/Cable environment with a Linksys router Models: BEFSRU31, BEFSR41 V.2, BEFSR11

Sierra Wireless AirLink LS300. Setup Steps

MIC-2 MKII & MIC-2 MKII DIN, Multi-instrument DATA SHEET

Contents. Table of Contents

How to assign an IP address and access your device

5100 Series, Catalog 5170 Quad-Ethernet Module

INSTRUCTION MANUAL ABB Power Quality Link Installation and user guide

802.11g Super-G 108Mb Wireless Access Point Quick Installation Guide

The GV-I/O Box 16 Ports provides 16 inputs and 16 relay outputs, and supports both DC and AC output voltages.

MIC-2 Multi-instrument DATA SHEET

ETH044-4 SSR (230VAC) and 4 Digital IO

How to assign an IP address and access your device

How to open ports in the DSL router firmware version 2.xx and above

How to upgrade firmware in DSL-xxx series router

Thermal Printer Configuration (EPSON)

Video Decoder Setup Guide

INSTALLATION INSTRUCTION MANUAL

Lab - Configure Wireless Router in Windows

Industrial Serial Device Server

Table of Contents. The Botron B92700 OMNIGND is a Multi-Ground Continuous Monitoring Automation System.

ETH002-2 Relays at 16A Technical Documentation

Revenue Grade with DATA-LOGGING and WAVEFORM CAPTURE

Network Troubleshooting Guide Ver 1.0

Decoder Firmware B1D-220-V AC User s Manual Decoder Firmware B1D-220-V AC User s Manual

LAN IP Setup Quick Start Guide

Document No. FO1002 Issue Date: Draft: Work Group: FibreOP Technical Team July 22, 2013 Final:

ThingsPro Software User s Manual

SR-201 Network Relay Quick Start Guide

SL620/DS-Tmini Snaplab+ Internet Configuration Setting procedure

Programming through Web browser:

IP SCAN UTILITY PROTOCOL

OUTDOOR IR NETWORK CAMERA Series

Product startup: G-30 + DIGIWARE C31 - U30-3xI35

!"!#$!%&'()!%*+,-%./0/123&&45&

MIC-2 MKII, Multi-instrument DATA SHEET

Contents. GV-I/O Box 8 Ports Key Features Compatible Software Packing List Overview DIP Switch...

HOME AUTOMATION, INC. Model 93A00-1. Serial Server. User s Manual

PMAC770 LAN Module User Manual V1.0

MODBUS APPLICATION MANUAL DKM-411

Dell C5518QT. Dell Display Control User s Guide

AirLive RS Security Bandwidth Management. Quick Setup Guide

אי.די.פי.מוצריזיהויאלקטרוניים בע"מ תושיה 6 תל-אביב, , פקס

Multi-instrument Communication, MIC-2 MKII DIN Quick Start Guide

Quick Start Guide. 1 Introduction. GV-Box Camera GV-BX120D / 220D / 320D. Packing List

Grandstream IP Phone Configuration Guides

Configuring the network clients

7NOX User Manual for Site Device. Book after-hours air conditioning in commercial buildings with ease.

Ethernet Interface Module

Web-Mon Guide. View E-Mon Web-Mon Product Page

WIALAN Technologies, Inc. Unit Configuration Thursday, March 24, 2005 Version 1.1

MDNET-5W. Wi-Fi/Ethernet/RS485 Converter Operation Manual. Version /03/24

RoadRunner 24AP(i+) Recovering Tool Instructions

Remote Gateway Configuration Utility Instructions

IS-381 / IS-382 IP Audio gateway. User Manual

ECAN-240. (Modbus TCP to 2-port CAN Bus Gateway User manual) ECAN-240 Modbus TCP to 2-port CAN Bus Gateway User Manual, Version 1.0.

How to manually set up EW-7228APn to extender wireless range

Quick Setup Guide. for Standalone Omada Access Points. EAP110 / EAP115 / EAP225 / EAP245 / EAP320 / EAP330 / EAP115-Wall

PQM - Power Quality Monitoring

Quick Start Guide for Standalone EAP

AXIS Camera Station S20 Appliance Series AXIS Camera Station S2008 Appliance AXIS Camera Station S2016 Appliance AXIS Camera Station S2024 Appliance

UMG 511. Class A EN UMG 511 Class A power quality analyzer. according to EN50160, IEEE 519, ITIC, IEC Areas of application

UNIBOX. Hotspot Management Application. Quick Start Guide

PHONE. user guide Version 1.1 FPP

Step 3 - How to Configure Basic System Settings

Zavio P5111/ P5116/ P5210 Quick Installation Guide

ConfigTool Instructions

DHE-1000 MPEG4 HD ENCODER. MPEG4 system with IP output. Technical documentation / Instruction set

NordField Electronics

Customer Installation Guide NBG-4615 v2 ZyXEL Wireless Router

UMG 605. UMG 605 power quality analyzer (EN 50160, IEEE 519, ITIC)

Riverbed Technology, Inc. 199 Fremont Street San Francisco, CA Phone Fax

User Manual of 11ac 1200Mbps Outdoor CPE NWA220

2) INSERT THE SETUP CD

Table of Contents. CRA-200 Analog Telephone Adapter 2 x Ethernet Port + 2 x VoIP Line. Quick Installation Guide. CRA-200 Quick Installation Guide

System Configuration. Browser Requirements on a second system. HP Z1 G2 Workstation with Intel vpro Technology Setup & Use Guide

NM6000 User's guide v1.2

PQM4000 and PQM4000 PQM4000RGW. Class A DIN 192x144 power quality analyzer for CTs. Class A certified in compliance with IEC/EN :2015 Ed.

LP Manual in PTP and MTP Mode.

WebNMS IoT Cloud Gate Deployment Guide

I-Fly Wireless Broadband Router

F3102 / F3107 / F3110 / F3115 / F3210 / F3215 PN: 86085K K

[Pick the date] DS-300 Configuration Guide v 5.7

ThingsPro Software User s Manual

KACCTV4CHA Networking Guide

Use of the TCP/IP Protocols and the OSI Model in Packet Tracer

1 Introduction to the software

Model XS1000 TCP/IP to RS232/422/485 Device Server User s Manual

HooToo IP Camera User Manual(part two)

Quick Network Setup Guide

Revenue Grade General Specifications

Transcription:

Accessing the AXM-WEB at Admin level This document will provide a brief overview of accessing the AXM-WEB at Admin level. In this level users will be able to read and view meter information as well as configure and control settings on the meter. To view the web interface of the AXM-WEB, an Ethernet connection is needed. Open an internet browser and type in the IP address of the meter in the browser search bar and hit the Enter key. The meter's web login page will display as followed: Figure 1 Login to the web page as 'Admin'. The default password is 'admin'. Upon successfully logging in you will be redirected to the Dashboard where a brief report of data from the meter will display. The Dashboard will also display how long the AXM-WEB has been up and communicating.

Figure 2 To view more data click on 'Metering'. This will display a list of parameters that can be viewed from the AXM-WEB. Click on the sub-section that corresponds to the data you would like to view: Basic Metering: This page will show the real-time readings such as voltage, current, power and etc. Power & Energy: This page will show the energy readings such as the import energy, export energy, total energy as well as the demand readings. Min/Max: This page shows the maximum and minimum statistics that the meter has recorded since the lifetime of the meter or from the last reset of the min/max statistics. THD: This page will show the power quality data such as the THD, THFF, crest factor and etc. for both voltage and current. Harmonics: This page will show the harmonics of the voltage and current waveform. It will display the harmonics of each phase in graphical and tabular format. Select between voltage and current to view their respective harmonics as well as between the 2 nd -31 st harmonics or 32 nd -63 rd. Phase Angles: This page will show the phase angles of the voltage and current waveform. Sequence: This page will show the positive, negative and zero components of the voltage and current waveform.

Figure 3 To view meter information/status click on the `Status' tab and select the information you would like to view: Device Information: This page will display meter information such as the model, serial number, firmware version and device address of the meter. It will also provide the serial number, firmware version, hardware version and MAC address of the AXM-WEB module. Alarm Status: This page will display the alarm log of the meter. It will provide the status of up to 16 alarm events indicating the parameter, value and timestamp of the alarm event. I/O: This page will show the status of the I/O Modules that are connected and their values. I.E. Relay Output status(on/off), DI status and etc. SOE: This page shows the Sequence of Event log for the enabled I/O module with timestamps. Figure 4

Basic meter settings can be configured through the web interface by clicking on the 'Settings' tab and selecting the configurations to change from the list that appears. Note: After making any changes in the settings tab, the AXM-WEB must be rebooted through the web interface by going to the 'Management' page. Figure 5 To configure settings such as the voltage, current wiring as well as the PT and CT ratios, select 'Meter' from the 'Settings' tab.

Figure 6 Voltage Wiring: Select how the meter's voltage input terminal is wired by selecting a configuration from the drop down list. I.E. for a three phase three wire configuration without a neutral, select 3LL. Current Wiring: Select the number of CT's that are connected to the meter's current input terminal by selecting a number from the drop down list. PT1: Enter the rated input of the potential transformer that is connected to the meter. Possible range is from 50 to 50000V. CT1: Enter the rated input of the current transformer that is used with the meter. Possible ranges for the CT1 is from 1 to 50000A. PT2: Enter the rated output of the potential transformer. Possible range is from 50 to 400V. CT2: Select the rated output of the current transformer from the drop down list. By default this setting is already configured. Click 'Save' after changing any settings. The AXM-WEB will also need to be rebooted from the 'Management' page. To configure settings related to the network select the 'Communication' option from the 'Settings' tab. The page you will be directed to is for configuring the meter's network settings. Other functions can be configured by clicking on the corresponding tab such as emails, SNTP and HTTP/FTP Post. These functions will be discussed in more details in separate documents.

Figure 7 Network Settings: You can change the configurations of your network parameters. DHCP: Select 'Manual' to manually configure the IP address to access the meter. If set to 'Manual', you'll also need to set the Subnet Mask and Gateway. Select 'Auto' to have the meter assigned a IP address automatically. With this selection the Subnet Mask, Gateway and DNS servers will also be automatically assigned. Note: After changing DHCP to Auto, check the display of the meter to obtain the new IP address that was assigned. IP Address: If the DHCP is configured to Manual, the IP address can be configured from this page. Subnet Mask: If the DHCP is configured to Manual, the Subnet Mask can be configured from this page. Gateway: If the DHCP is configured to Manual, the Gateway can be configured from this web page. DHCP DNS Server 1: Enter the address of the DNS 1 server in this page. DHCP DNS Server 2: Enter the address of the DNS 2 server in this page. HTTPS Port: Enter the HTTPS port number of the meter. By default, this setting is configured to 443. The range can be from 6000 to 9999. Modbus TCP Port: Enter the Modbus port number of the meter. By default, this setting is configured to 502. The range can be from 2000 to 5999.

Click 'Save' after changing any settings. The AXM-WEB will also need to be rebooted from the 'Management' page. Management: This page can be used to reset parameters such as the Demand, Energy, Max/Min, alarm records and etc as well as setting or changing the password for the access levels. This page is also where the AXM-WEB can be rebooted so that all changes can take effect. Figure 8 Firmware: This page is used for updating the firmware version on the AXM-WEB module. If you would like to update the firmware, please contact Technical Support with the current firmware version of the AXM-WEB module.

Figure 9