Field Update Guide. for Raven Viper Pro

Similar documents
Cruizer II Snow Depth Feature

Note: These installation instructions are only for the 4430/4440 Sprayer. For other SPX models please refer to P/N , &

RAM Rail Mount Kit RAM 201U 5 Arm RAM 2461U Monitor Mount RAM 235U Base, Double U-Bolt

RAM Rail Mount Kit RAM 201U 5 Arm RAM 2461U Monitor Mount RAM 235U Base, Double U-Bolt

DirectCommand Installation RoGator Model Year Ag Leader Technology

DirectCommand Installation CASE IH SPX Ag Leader Technology. PN: Rev. E January 2014 Page 1 of 19

DirectCommand Installation RoGator 864/874/1064/1074 (MY 2006 & Earlier) Ag Leader Technology

Ag Leader Technology. DirectCommand Installation RoGator Model Years

Quick Reference Guide

Quick Reference Guide

DirectCommand Installation Hardi Spray Box II 39-pin Kit. Ag Leader Technology. PN: Rev. E January 2014 Page 1 of 16

Ag Leader Technology. DirectCommand Installation Hardi 20-pin Interface Kit (Sprayer Chassis Mount)

Part Name/Description Part Number Quantity

DirectCommand Installation DirectCommand Complete Wiring Harness

Jaguar F-TYPE CAM Dual Camera interface for select 14+ Jaguar vehicles NTV-KIT589

Part Name/Description Part Number Quantity

Barracuda Video in Motion for select GM vehicles NTV-KIT211

Miller Nitro 4000 Series

Ag Leader Technology. DirectCommand Installation Miller Nitro 5000 & 6000 ISO Kit

9-3 M03-06, radio/navigation... page M07-, radio... page M07-, navigation... page M06-, radio/navigation...

Installation and Operation Guide

TM LOCKPICK C8 INSTALLATION OPTIONS COPYRIGHT 2011 COASTAL ELECTRONIC TECHNOLOGIES, INC. UNPLUG ORIGINAL RADIO CONNECTORS THEN PLUG IN HERE

Jaguar F-TYPE CAM 16. Dual Camera interface for select 16+ Jaguar vehicles NTV-KIT746 BHM 05/31/16 NTV-DOC259

Installation Manual. Flow Max 110

PS/IO Circuit Board Retrofit

INSTALLATION INSTRUCTIONS

INSTRUCTION BULLETIN

EMC 10T "CE" Mechanical Upgrade Procedure

If technical support is required, please contact Advent Technical Support at

EH50 ATTENTION: SECURITY COVERS ARE NO LONGER INCLUDED IN THE HEADREST KITS AS OF

Power Supply and Fan Module Installation

PoE/FPR Kit for Auto-Sync Time Clock. The Auto-Sync Time Clock is a validated time system with a Web interface and auto discovery.

GEN 6 LOCKPICK INSTALLATION OPTIONS COPYRIGHT 2010 COASTAL ELECTRONIC TECHNOLOGIES, INC.

Ag Leader Technology Insight. Direct Command Installation Spra-Coupe 7000 Series

DirectCommand Installation 5 Channel Spreader Control Module Technology

Raven Adapter Harness

Installation Instructions

INSTALLATION INSTRUCTIONS

TOYOTA SIENNA Dual Headrest Video

QUICK START INSTALLATION GUIDE

INSTALLATION INSTRUCTIONS

M101M4 Tablet PC Quick Start Guide V1.0

NTG3-SL NTV-KIT142. Overview Mercedes-SL. Backup camera / AV input / RSE / Video In Motion interface. Kit Contents. NTG3 Module NTV-ASY171

GM2 FIM LOCKPICK INSTALLATION OPTIONS COPYRIGHT 2012 COASTAL ELECTRONIC TECHNOLOGIES, INC.

Note: Indented items indicate parts included in an assembly listed above

Removing and Replacing Parts

Installation Guide. Wyse R Class Conversion to WES7. Wyse USB Firmware Tool TM Release Issue: PN: L Rev. B

MCH WIRE HARNESS WITH QUICK DISCONNECT REPLACEMENT Initial Release 1/31/2013

SIR-PCM3 955/997 SIRIUS Satellite Radio interface for Porsche PCM 3 radios NTV-KIT266/285

TM C8 LOCKPICK PRO STEERING WHEEL CONTROLS * OPERATIONS WHILE MENUS ARE DISPLAYED ON INSTRUMENT CLUSTER CONTROLS ON BACK OF STEERING WHEEL BACK

Date: Order No.: Supersedes: Group:

Coastal Electronic Technologies, Inc. GM LOCKPICK GMX-320 Installation and Operation Instructions

Installing and Removing SDRAM and DRAM

Floppy Disk To USB. Converter Installation and. Operation Manual

Installing the upgrade memory kit in the G450 and G430 Media Gateway

MTX-D Ethanol Content and Fuel Temperature Gauge User Manual

ADDITIONAL CAM POWER REVERSE CAM POWER BLUETOOTH MUTE AUDIO + IN AUDIO - IN 12V ACC OUTPUT 12V CONSTANT GROUND

INSTALLATION INSTRUCTIONS

WARNING SPECIAL HANDLING REQUIRED!!!

Removal and Installation8

PRECAUTIONS: Please read before you start the installation

Please read thoroughly before starting installation and check that kit contents are complete.

Revised: Page 1

Marine User Guide. USBT202 Series High Power USB Charging Port

EPX Touchscreen and Display Replacement Assemblies

MTX-A Temperature Gauge User Manual

Navigation interface for Jeep GC 5 RA2 NTV-KIT581

Jippo Play - Installation Manual Page 1 INSTALLATION MANUAL. Intro Camera Operation Installation - Wrangler JK... 2

E1135C PDU and Pod Upgrade Procedure

Installation Instructions

CRESCENDO /7200 G3. Quick Start Guide for Crescendo /7200. Processor Upgrade Card for Power Macintosh 7200/8200 Computers

Toshiba Satellite A105-S4011 Touchpad

Section. Service & Maintenance. - Core & Hard Disk Drive (HDD) - Amplifier - Monitor - UPS - Dollar Bill Acceptor - Fan Filter G - 1

Ag Leader Technology. DirectCommand Installation Rogator 900/1100/1300 Sprayers

UCTv2-W. 18 Wrangler uconnect 4.0 (CarPlay/Android Auto) Dual Camera Interface NTV-KIT851 BHM 01/19/18 NTV-DOC308

TrueNAS Z SERIES NODE SATADOM REPLACEMENT KIT. August 2017 Edition

*000IPODIG* ipod Installation Guide. Tools Needed: (depending upon vehicle) 000IPODIG IMPORTANT

Job Aid: Replacing the Field Replaceable Units (FRUs) for the Avaya G430 Media Gateway

Installation Guide. HP J2437A 4-Port Token Ring Interface for the HP Router 650

MyTouch FIM LOCKPICK INSTALLATION OPTIONS COPYRIGHT 2013 COASTAL ELECTRONIC TECHNOLOGIES, INC.

Instruction Sheet Updating SmartPAC 2 Firmware

PTDT V Quick Installation & Reference Guide. Ver Battery Management Solutions by. PowerDesigners

TOYOTA TUNDRA/ BENCH IPOD INTERFACE Part Number: Accessory Code: R13

Removing and Replacing FRUs from the Cisco ASR 1001-X Router

Integrated Battery Control System LBCS Step-by-Step Setup Guide

GMNAV1 Advent Integrated Navigation

INSTALLATION INSTRUCTIONS

CHRY MULTI-CAM. Dodge/Jeep uconnect (RA4) Interface with 6 video inputs NTV-KIT764 BHM 09/25/17 NTV-DOC266

CONSOLE CONNECTOR KIT 9501 INSTALLATION INSTRUCTIONS

Microprocessor Module Replacement Kit for Multi-Zone Leak Monitors Instruction Manual

imac Intel 27" EMC 2639 Hard Drive

BD Laser User Guide * IMPORTANT * PLEASE READ THE FOLLOWING INSTRUCTIONS CAREFULLY AS IMPROPER USE MAY DAMAGE THE MACHINE AND VOID THE WARRANTY.

CHRY UNI-CAM v2. Chrysler/Dodge/Jeep uconnect (RA4/RA3/RA2) Dual Camera/Control in Motion Interface NTV-KIT759

BP Brine Pro Brine Maker Software Update. Installation Instructions. Original Instructions CAUTION

itech Training Courses iphone 5S LCD Assembly Replacement Guide

Gazer VI700A-NTG45 and VI700W-NTG45 INSTALLATION MANUAL

W205-N RVC NTV-KIT703

Written By: John Sutton

Installing TAM Air Assistant Software TM

Upgrade Instructions Printer Terminal Holder

Transcription:

Field Update Guide for Raven Viper Pro

Introduction The field update kit (P/N 117-0171-467) is designed to allow the Raven Viper Pro to utilize the automatic power down feature without returning the console to Raven Industries. The procedures in this document are intended for use on Case IH application equipment but may be used as a reference if the Viper Pro is installed on other equipment. For additional assistance with the field update kit, please contact a local Raven dealer. Important: Do not modify contents of the supplied USB flash drive. Files stored on the provided flash drive are configured from the factory and should not be removed until the field update process is complete. Note: The firmware update program required to complete the field update is only compatible with CAN firmware versions later than 15. Any systems operating with firmware versions 15 or earlier will need to be returned to Raven Industries for update. Contact a local Raven dealer for assistance. Important Safety Information NOTICE Read the following procedures carefully before installing the field update kit and follow all safety information presented within this guide. CAUTION Do not reverse the power leads. Doing so could cause severe damage to the equipment. Always make sure that the power leads are connected to the correct polarity as described in the following procedures. It is recommended to disconnect the Raven Viper Pro from the interface harness before rewiring the cable to prevent damage to the field computer. Kit Contents The following should be provided with the field update kit. Table 1: Field Update Kit (P/N 117-0171-467) Contents Qty. Description Part Number 1 USB Flash Drive, 4 GB 063-0173-427 2 Terminal, Ring 405-0200-053 1 Terminal, 1/4 Male Quick Disconnect 405-2001-016 1 Wire Cutter/Stripper 321-0000-393 1 Amp Extraction Tool 321-0000-392 1 Viper Pro Field Update Kit Guide 016-0171-530 Be sure all of the above items are available before beginning the installation of the update kit. 1

Rewiring the Viper Pro Harness The following procedure is required to reroute the Viper Pro interface cable to allow the automatic power down feature to function correctly. CAUTION Damage to electrical equipment or electrical shock may occur when working around exposed wiring or when cutting power and ground wires. Disconnect the vehicle battery, use insulated tools or wear rubber gloves as appropriate. 1. Power down the Viper Pro field computer. 2. Disconnect the two round connectors from the back of the Viper Pro to prevent damage to the field computer. Interface Connectors 3. Locate the instrument panel with the product pump and hydraulic shut off switch in the vehicle cabin. Remove the 4 screws and carefully lift the instrument panel. Pump Instrument Panel 2

4. Locate the factory power and ground wire cluster under the instrument panel. The factory wire cluster is spliced into power and ground wires which lead to the accessory port or cigarette lighter in the vehicle cabin. Factory Wire Splice 5. Trace wires to help identify the power (red) and ground (white) wires used to power the Viper Pro field computer. 6. Using the supplied wire cutter/stripper (P/N 321-0000-393), cut the power and ground leads powering the field computer approximately 2 in [5 cm] from the factory splice. CAUTION Damage to electrical equipment or electrical shock may occur when cutting power and ground wires. Disconnect the vehicle battery, use insulated tools or wear rubber gloves as appropriate. Note: A crimp connector will be installed on the red (power) wire still connected to the factory splice later in this process. 7. Locate the knockout below the instrument panel and route the leads cut from the factory splice through an open port. Knockout Location 8. Crimp the supplied ring terminals (P/N 405-0200-053) onto each of the lead wires. 3

9. Route and connect the red power wire to the positive post located next to the radar speed sensor. Positive Post Radar Speed Sensor 10.Route and connect the white ground wire to the negative post located in the right, rear corner below the cabin Negative Post 11.Open the panel on the front side of the console along the right side of the vehicle cabin. Grey Wire with Quick Disconnect Terminal 12.Locate the grey wire with the female 1/4 quick disconnect terminal. 13.Locate the red (power) lead wire cut previously in step 6. 4

14.Use the supplied wire cutter to strip back the insulation on the lead wire and connect the supplied male 1/4 quick disconnect terminal (P/N 405-2001-016). 15.Route the grey wire in the front panel to the red wire underneath the instrument panel and connect the quick disconnect terminals. 16.Carefully replace the console front panel. Note: Do not replace the pump instrument panel until the Viper Pro Firmware Update section on page 6 is completed. Re-pin the Viper Pro Harness The Viper Pro interface cable must be modified to take advantage of the automatic power down feature on the field computer. Review the following procedure to complete the installation of the field update kit. 1. Locate the round, 16-pin cable connector (female pins) disconnected from the back of the Viper Pro. 16 Pin Interface Connector 2. Remove the two screws on the connector retainer and carefully unscrew the shroud from the connector. It may be necessary to use a set of pliers to help unscrew the connector. Be careful not to damage the plastic connector or shroud. 3. While looking at the face of the connector, locate pin locations 2 and 14. 4. Insert the supplied Amp pin extractor tool (P/N 321-000-392) into the pin 2 location and depress the plunger to remove the pin. 5

5. Carefully pull the grey wire to remove the Amp pin from the connector. 6. Reinsert the pin into the pin 14 location on the cable connector. Carefully push the wire to fully seat the pin into the connector. 7. Test that the pin is properly seated by gently tugging on the grey wire. 8. Replace the connector shroud and replace the retainer and lock screws. 9. Reconnect the interface cable to the Viper Pro field computer. Viper Pro Firmware Update To complete the field update of the Viper Pro, the following procedure must be performed to update the field computer firmware. 1. Locate the 4-pin Deutsch connector labeled CAN under the pump switch instrument panel. The connector should be located near the factory power and ground cluster found earlier in the field update process. 2. Disconnect the 4-pin connectors. To help prevent failure of the firmware update, these connectors must remain disconnected throughout the firmware update process to prevent. 3. Disconnect the cable connections on the back of the Raven CAN switch box or Switch Pro. To help prevent failure of the firmware update, these connectors must remain disconnected throughout the firmware update process. 4. Insert the provided USB flash drive (P/N 063-0173-427) into the Viper Pro. 5. Press the power button on the Viper Pro to power up the field computer. 6. When the Initializing Viper prompt is displayed, select the Load XP Desktop option. 6

7. When the XP desktop is displayed on the Viper Pro field computer, select the Start button in the lower, left corner of the display and touch the My Computer icon in the displayed menu. 8. Select the Removable Disk (E:) icon displayed on the screen with a double tap to display the disk contents. 9. Double click on the ViperST10 Programmer.exe icon to begin the update process. The update may take approximately 15 seconds to begin. When the update is in progress, the Viper Pro will display a Tx and Rx window on the screen. Note: If the update is proceeding very slowly, shut down the Viper Pro and restart the procedure. If the Viper Pro will not shut down, remove the main connector from the back of the field computer for at least 10 seconds and then reconnect. 7

10.When the update is complete, the following prompt will be displayed. 11.Touch the OK button and then select the Start button and Shut Down from the displayed menu. 12.Select Restart to reboot the Viper Pro field computer. Note: If the Viper Pro fails to restart, remove the main interface cable connector for at least 10 seconds. Reconnect the cable and press the power button to restart the Viper Pro. 13.Start the Viper Pro management system. 14.From the main Viper Pro screen, select the Menu button in the lower, right corner of the display and select About. 15.Verify that CAN firmware version 22 is shown. If so, the firmware update has been successful. 16.Check the software version displayed on the screen. a. If the software version is 3.5.0.21 or newer, no software update is necessary to utilize the automatic power down feature. Continue with the following steps to return the field computer to operational status. b. If the software version is lower than 3.5.0.21, a software update is required before the automatic power down feature may be used. Continue with the following steps and then complete the Viper Pro Software Update section on page 9. 17.Shutdown the Raven Viper Pro field computer. 18.Reconnect the Raven CAN switch box or Switch Pro. 19.Reconnect the 4-pin CAN connectors located below the pump switch instrument panel. 20.Carefully replace the instrument panel. 8

Viper Pro Software Update Note: Software version 3.5.0.21 or newer is required to utilize the automatic power down feature with the field computer. The USB flash drive (P/N 063-0173-427) provided in the field update kit contains a software update file compatible with the automatic power down feature. Software updates are also available from the Raven Applied Technology Division web site: www.ravenhelp.com Refer to the Viper Pro Installation and Operation Manual for additional information on applying software updates obtained from the web site. 1. Insert the provided USB flash drive (P/N 063-0173-427) into the Viper Pro. 2. Press the power button on the Viper Pro field computer. 3. Touch the Display Program List button when the following prompt is displayed. 4. On the Program Selection Menu, touch the Install Viper Pro option. Allow the field computer the field computer to complete the software update. 5. Restart the Viper Pro management system. 6. From the main Viper Pro screen, select the Menu button in the lower, right corner of the display and select About. 7. Verify that software version 3.5.0.21 or newer is shown. If so, the software update has been successful. Review the Viper Pro Installation and Operation Manual for more information on the automatic power down feature. 9

Viper Pro Field Update Guide (P/N 016-0171-530 Rev A 1/12 E18895) Raven Industries Applied Technology Division Toll Free (U.S. and Canada): (800)-243-5435 P.O. Box 5107 or Outside the U.S. :1 605-575-0722 Sioux Falls, SD 57117-5107 Fax: 605-331-0426 www.ravenprecision.com www.ravenhelp.com Notice: This document and the information provided are the property of Raven Industries, Inc. and may only be used as authorized by Raven Industries, Inc. All rights reserved under copyright laws.