FCD-E1LC, FCD-T1LC Managed E1/T1 or Fractional E1/T1 Access Units

Similar documents
FCD-E1, FCD-T1 E1/T1 or Fractional E1/T1 Access Units

FCD-E1E Managed E1 and Fractional E1 Access Device

Modular E1 or Fractional E1 Access Unit. Dial-out for alarm report The E1 main link can be supplied with the following options:

ASMi-52. 2/4-Wire SHDSL Modem FEATURES

2/4-wire SHDSL Modem/Multiplexer

ASMi-52 2/4-wire SHDSL Modem/Multiplexer

FCD-155. STM-1/OC-3 Terminal Multiplexer FEATURES

ASMi-54L. Data Sheet. SHDSL.bis Modem

ASMi-54L SHDSL.bis Modem

RICi-E1, RICi-T1 Fast Ethernet over E1/T1 Intelligent Converters

Vmux-400 GSM A-bis/A-ter Optimization Gateway

Where to buy > Product page >

ASMi-54 SHDSL.bis Modem

FCD-155 STM-1/OC-3 Terminal Multiplexer

E1/T1 or Fractional E1/T1 Modular Access Device with Integrated Router

MARKET SEGMENTS AND APPLICATION

FOMi-40 Fiber Optic Modem with Remote Management

ASMi-54 SHDSL.bis Modem

Optimux-34, Optimux-25

Kilomux-2100/2104 KVF.6 E1/T1 Voice Compression Module

Optimux-34 Fiber Optic Multiplexer

Optimux-108, Optimux-106

IPmux-11. TDMoIP Gateway DESCRIPTION FEATURES

This provides an easily configurable solution, flexible enough to meet the specific requirements of a broad range of applications.

FCD-155. STM-1/OC-3 Terminal Multiplexer DESCRIPTION FEATURES

E1/T1 or Fractional E1/T1 Access Unit with Integrated Router

Optimux-1553 STM-1/OC-3 Terminal Multiplexer

IPmux-1E TDM Pseudowire Access Gateway

IPmux-16 TDM Pseudowire Access Gateway

Gmux Modular TDMoIP Gateway FEATURES

Optimux-4T1 Four-Channel T1 Multiplexer

Optimux-108, Optimux-106

Vmux-110. Voice Trunking Gateway FEATURES

Optimux-1553 E3/T3 STM-1/OC-3 Terminal Multiplexer

Multiservice Network Termination Unit

LA-140. Advanced ATM IAD FEATURES

Vmux-210 Analog Voice Trunking Gateway

IPmux-14. TDM Pseudowire Access Gateway FEATURES

Optimux-1032, Optimux-1025

Vmux-2120 Voice Trunking Gateway

FCD-155 STM-1/OC-3 Terminal Multiplexer

FCD-155 STM-1/OC-3 Terminal Multiplexer

RICi-16 Ethernet over Bonded PDH Network Termination Unit

IPmux-1E. TDMoIP Gateway FEATURES

IPmux-14. TDMoIP Gateway FEATURES DESCRIPTION

Megaplex-2100/2104. Data Sheet. Modular Integrated Access Multiplexers

Optimux-108, Optimux-106 Four-Channel E1/T1 and Ethernet Multiplexers

ETX-102 Carrier Ethernet Demarcation Device

Kilomux-2100/2104. Data, Voice, Fax and LAN Integrating Modular Multiplexer

Vmux-110 Voice Trunking Gateway for Remote Sites

PSEUDOWIRE PERFORMANCE

RICi-16 Ethernet over Bonded PDH Network Termination Unit

FCD-155E STM-1/OC-3 Add/Drop Multiplexer

FCD-155E STM-1/OC-3 Add-Drop Multiplexer

ACE-2002, ACE-2002E. Multiservice Access Concentrators/ ATM Network Termination Units FEATURES

Megaplex-2100/2104 Modular Integrated Access Multiplexers

Kilomux-2100/2104. Data, Voice, Fax and LAN Integrating Modular Multiplexer FEATURES

IPmux-24 TDM Pseudowire Access Gateway

Optimux-108, Optimux-106

DXC /1/0 modular multiservice cross connect access node up to 1.2 Gbps matrix. Data Sheet. Multiservice Access Node. The Access Company

Kilomux-2100/2104. Data, Voice, Fax and LAN Integrating Modular Multiplexer FEATURES

HS-2. MEGAPLEX-2000/2100 Module. 2-Channel High Speed Data Module DESCRIPTION FEATURES

IPmux-4LGE TDM Pseudowire Gateway

IPmux-2L, IPmux-4L. IPmux-2L, IPmux-4L are a TDM pseudowire. also serves as an Ethernet-based access device.

ETX-201A Carrier Ethernet Demarcation Device

OPERATION MANUAL INSTALLATION AND ML-8E1, ML-8T1. 8-Port Main Link E1 and T1 Modules. Megaplex-2100/2104 Version 12. The Access Company

Product page > Link-layer OAM according to IEEE 802.3ah is used for fault indication and loopback activation response.

LRS-12. "Last Mile" SNMP Modem Rack FEATURES

Atrie WireSpan 620. User's Manual

FMUX1001 Modularized 16E1/T1 + 4x GbE Managed Fiber Multiplexer FMUX101 Modularized 16E1/T1 + 4x FE Managed Fiber Multiplexer

IPmux-216 TDM Pseudowire Access Gateway

Loop-O9330 Fiber Optical Mux

LA-110 Advanced Integrated Access Device

F8008. Fiber Modem for up to 4E1 /8E1 +RS232+Ethernet. + optional V.35/QFXS/QFXO

ACE-202/2002/2002E ATM STM-1, STM-4, IMA and ATM UNI Modules

Installation and Operation Manual VF-30/VF-60. Single/Dual E1 Digital Voice Compression Modules. Megaplex-2100 Version 11 MEGAPLEX-2100 MODULES

HS-RN. 4-Channel Low Speed Data Module with End-to-End Signaling OPERATION MANUAL INSTALLATION AND

F8016. Fiber Modem for up to 4E1 /8E1/12E1/16E1 + RS232+Ethernet+ optional V.35/QFXS/QFXO

Kilomux-2100/2104 KVF.8 8-Channel Analog Voice Compression Module

MEGAPLEX-2100 MODULE LS-2A. 10/6-Channel Sync/Async Low Speed Data Module for X.50, X.58 or SDM Multiplexing Installation and Operation Manual.

Kilomux Accessories KM-Ringer, Ringer-2000, Ringer-2200N DC Feed and Ring Power Supplies for Voice/Fax and ISDN Modules

Data Sheet SRM-6A. Short-Range Asynchronous Modem. The Access Company

Note: IPmux-155L equipped with the AC or 48 power supply modules supports up to 16 MiRICi-E3T3 units.

4xT1/E1 i nline probe ASE With LinkSafe capabilities

Loop-O 9300 Fiber Optical Mux

RADview. Element Management System Optimux-4E1, Optimux-4T1 Optimux-4E1L, Optimux-4T1L RAD Data Communications Publication 07/05

Data Sheet SRM-3A. Ultra-Miniature Isolated Short-Range Async Modem. The Access Company

ACE-3000 Family ACE-3100 Cell-Site Gateway

V C ALIANT OMMUNICATIONS. Product Brochure & Data Sheet

ISO 9001:2000 Certified Company

T3 Interface Converters

V C ALIANT OMMUNICATIONS. VCL-4 E1 + Ethernet PDH Optical Multiplexer. Data Sheet U.K. INDIA U.S.A. Valiant Communications (UK) Ltd

Gmux-2000 Hub-Site Pseudowire and Voice Trunking Gateway

ACE-3000 Family ACE-3105 Cell-Site Gateway. 2G, 3G and HSDPA cellular traffic over packet-switched networks (PSNs) and ATM, using DSL uplinks

ATM OVER PACKET CAPABILITIES

SFP Transceivers Small Form-Factor Pluggable Transceivers

Protocol/interface converter series

ACE-3000 Family ACE-3200 Cell-Site Gateway

ETX-203AX Carrier Ethernet Demarcation Device

Megaplex-2100/2104. Modular Integrated Access Multiplexers

Transcription:

Data Sheet FCD-E1LC, FCD-T1LC Managed TDM multiplexers for access to full or fractional E1/T1 services Managed access units for E1/T1 or fractional E1/T1 service E1/T1 main link and sublink support framed and unframed signals One or two data ports with selectable sync data rates: n 56 kbps or n 64 bps Serial data port interfaces: V.24, V.35, V.36/RS-449, RS-530, or X.21 Optional sub-e1/t1 drop-and-insert port for PBX connectivity Optional Ethernet 10/100BaseT bridge with VLAN support, or V.24 serial interface (second user port) FCD-E1LC and FCD-T1LC are managed access units that convert rates and interfaces for full or fractional E1/T1 services. These units support a single or dual serial n 56 kbps or n 64 kbps data user interface. The second serial data interface port can be replaced by an Ethernet LAN interface to allow LAN-to-LAN connectivity over TDM media. The FCD-E1LC and FCD-T1LC units interconnect with RAD modular DXC, Megaplex products and E1/T1 equipment from other vendors to support multilink star applications such as access to SDH networks. All these products DXC, FCD, and Megaplex operate together under centralized SNMP network management. The Access Company

FCD-E1LC, FCD-T1LC The E1 interface is compatible with virtually all carrier-provided E1 services and meets ITU recommendations G.703, G.704, G.706, G.732, G.823, and G.826. It supports both 2 and 16 frames per multiframe, with or without CRC-4. The E1 interface also accepts a 2048 kbps data stream and converts it to an ITU-T Rec. G.703 unframed signal for transport over the E1 main link and sublink. Line code is HDB3. The integral LTU ensures a range of up to 2 km (1.2 miles) and is software-selectable. The T1 interface is compatible with virtually all carrier-provided T1 services, including ASDS from AT&T. It complies with TR-62411 and TR-62421 and supports D4 and ESF framing formats. Zero suppression over the line is software-selectable for either transparent, B7ZS or B8ZS. The software-selectable integral CSU ensures a range of up to 2.1 km (1.3 miles). The optional sub-e1 port can be configured to work without CRC-4, while the E1 main link is working with CRC-4. This enables connection of E1 equipment not supporting CRC-4, over an E1 network that is working with CRC-4. The optional sub-t1 port can be configured with D4 or ESF framing, while the T1 main link framing is ESF. This enables connection of T1 D4 equipment over an ESF T1 network. The FCD-E1LC and FCD-T1LC units can be programmed to assign data automatically from each data port into consecutive timeslots. The user can also assign timeslots manually. Timing for the E1/T1 main link and sublink may come from the recovered receive clock, an internal oscillator, or one of the data ports. This multiple clock source selection ensures maximum flexibility for supporting different applications. Front panel LEDs indicate alarms, E1/T1 signal loss, and diagnostic loopback operation. Rear panel LEDs on the Ethernet interface modules indicate LAN status and activity. FCD-E1LC and FCD-T1LC are compact standalone units. A rack mount adapter kit enables installation of one or two (sideby-side) units in a 19-inch rack. USER INTERFACES The FCD-E1LC and FCD-T1LC units feature the following user interfaces: Serial data interfaces: V.24, V.35, V.36/RS-449, RS-530, X.21 Ethernet 10/100BaseT LAN interface module with a built-in bridge (IR-ETH/QN). The synchronous data ports of FCD-E1LC operate in the following clock modes: DCE: The FCD units provide both transmit and receive clocks to the user equipment, with optional sampling of the incoming data with an inverted clock DTE1: The FCD units provide the transmit clock, while the transmit clock is provided by the attached user equipment DTE2: The attached user equipment provides both transmit and receive clocks. The IR-ETH/QN interface module has a 10/100BaseT interface that supports VLAN frames, autonegotiation, fault propagation, and automatic learning and aging. The module transparently connects FCD-E1LC and FCD-T1LC to remote LANs over E1/T1 links. It filters Ethernet frames and forwards only frames that are destined for the WAN.

MANAGEMENT & MAINTENANCE Status and diagnostic information is defined, configured, and monitored using one of the following methods: ASCII terminal connected to the async control port SNMP management Telnet. All models support an internal SNMP agent that is managed by any generic SNMP station or by the RADview SNMP-based management application. FCD-E1LC and FCD-T1LC support both dial-in and dial-out modem connections through the serial RS-232 port, by using SLIP or PPP protocol or a command line interpreter on an ASCII terminal. These out-of-band connections can be used for remote configuration and monitoring, as well as for sending callout alarm messages. Up to 100 time-stamped alarms are available for retrieval through the supervision terminal, a Telnet host, or a RADview management station. Inband management can be performed either by dedicated timeslot using standard Frame Relay protocol (RFC 1490), or by using the spare S a bits on timeslot 0 for FCD-E1LC or FDL bits for FCD-T1LC. This allows the user to setup, monitor, and run diagnostics on the remote unit. The spare bits on TS0 or FDL that are used for inband access must be passed transparently end-to-end. Maintenance capabilities include user-activated local and remote loopbacks on the E1/T1 main link, sublink, and data ports. The user can activate a BER test on the main link. Also, the main link responds to an ANSI FT1 RDL (T1.403) inband loop code, or a user-configured pattern generated by a remote FCD-E1LC, FCD-T1LC, or DXC in a specific bundle of timeslots allocated only to that port. The user can also define BER or inband tests to run on any timeslot of the main link. E1 network statistics are stored in memory, according to RFC 1406. Statistical information can be retrieved locally through the control port. T1 network statistics are stored in memory, according to ANSI and AT&T standards. The statistical information may be retrieved by the service provider (ANSI only) or locally through the control port. Figure 1. Extended Ethernet Management over E1/T1 Network

Data Sheet Specifications E1 MAIN LINK AND SUBLINK Framing 256N (no MF, CCS) 256N (no MF, CCS) with CRC-4 256S (TS16 MF, CAS) 256S (TS16 MF, CAS) with CRC-4 Unframed Bit Rate 2.048 Mbps Line Code AMI Zero Suppression HDB3 Line Impedance 120Ω, balanced 75Ω, unbalanced Transmit Timing Locked to the system clock Signal Level Receive: 0 to 10 db without LTU 0 to 36 db with LTU Transmit: ±3V (±10%), balanced ±2.37V (±10%), unbalanced Jitter Performance As per ITU G.823, ETSI TBR-12 and TBR-13 Connectors RJ-45, 8-pin, balanced Two BNC coaxial, unbalanced, using adapter cable Compliance ITU G.703, G.704, G.706, G.732, G.823, G.826 Performance Monitoring Local support of CRC-4 Full statistical diagnostics according to RFC-1406 T1 MAIN LINK AND SUBLINK Framing D4 ESF Unframed (main link only) Bit Rate 1.544 Mbps Line Code AMI Zero Suppression Transparent, B7ZS, B8ZS Line Impedance 100Ω, balanced Transmit Timing Locked to the system clock Signal Level Receive: 0 to 10 db without CSU 0 to 36 db with CSU Transmit: 7.5, 15, 22.5 db with CSU ±3V, ±10% soft adjustable at 0 to 655 ft without CSU T1 Jitter Performance As per AT&T TR-62411 Connector RJ-45, 8-pin, balanced Compliance AT&T TR-62411, AT&T 54016, AT&T TR-62421, ANSI T1.403 Performance Monitoring Local support of ESF diagnostics according to AT&T PUB 54016 Full statistical diagnostics according to ANSI T1.403-198 DATA PORTS Connectors D-type, 25-pin, RS-530, female (converted via adapter cables to V.35, X.21, V.36/RS-449) Additional connectors for second user port: D-type, 25-pin, female for V.24, RJ-45 for ETH Data Rate n 56/64 kbps (n=1 to 24) for T1 n 64 kbps (n=1 to 31) for E1 n 64 kbps (n=1 to 2) for V.24 port Clock Modes DCE: Rx and Tx clock to user device DTE1: Rx clock to user device; Tx clock from user device (not for X.21 and V.24) DTE2: Rx and Tx clock from user device (not for X.21 and V.24) Control Signals CTS follows RTS or constantly ON, softselectable DSR constantly ON, unless in test mode DCD constantly ON, unless in sync loss

FCD-E1LC, FCD-T1LC ETHERNET BRIDGE PORT Interface and Connector 10/100BaseT (UTP) with shielded RJ-45 Maximum Frame Length 1536 bytes LAN Table 2048 MAC addresses Throughput 4,000 pps Latency 300 μsec (64-byte frame size, 2M LAN rate) Buffer 120 frames Line Code 10BaseT: Manchester 100BaseT: MLT3 WAN Protocol HDLC DIAGNOSTICS Main E1/T1 link Local loopback Remote loopback BER test Code-activated inband loopback per data port Code-activated T1 network loopback (FCD-T1LC only) Sublink Local loopback Remote loopback Code-activated T1 network loopback (FCD-T1LC only) Data Port Local loopback Remote loopback GENERAL System Clock Internal clock: ±50 ppm Loopback timing: ±130 ppm External timing from data port: ±130 ppm Management Port Interface: RS-232, 9-pin D-type, female Format: asynchronous Baud rate: 1.2 115.2 kbps, autobaud Character: 8-bit no parity, 7-bit odd or even parity Timeslot Allocation Consecutive (bundled) User-defined Indicators General: PWR (green), TST (yellow), ALM (red) Main/sub-E1: LOC SYNC LOSS (red), REM SYNC LOSS (red) Main/sub-T1: RED ALARM (red), YEL ALARM (yellow) Physical Height: 4.4 cm (1.7 in) Width: 21.7 cm (8.5 in) Depth: 17.0 cm (6.7 in) Weight: 0.8 kg (1.8 lb) Power AC/DC: 100 to 240 VAC, 48 to 60 VDC, nominal Power consumption: 5W max. Environment Temperature: 0 50 C (32 122 F) Humidity: Up to 90%, non condensing Table 2. FCD Comparison Table Features FCD-E1/T1 FCD-E1L/T1L FCD-E1LC/T1LC Total user ports 3 2 3 Interface types RS-530, V.35, V.36, X.21, Ethernet bridge (10BaseT with VLAN support), Sub-E1 RS-530, V.35, V.36, X.21, Ethernet bridge (10/100BaseT with VLAN support), ETH router RS-530, V.24, V.35, V.36, X.21, Ethernet Bridge (10/100BaseT with VLAN support), Sub-E1 E1/T1 line type Copper/Fiber Copper Copper LCD panel Auto-configuration SNMP management Interoperability Megaplex, DXC Megaplex, DXC Megaplex, DXC

FCD-E1LC, FCD-T1LC Data Sheet Ordering FCD-E1LC/&/*/% E1 or fractional E1 access unit FCD-T1LC/&/*/% T1 or fractional T1 access unit Legend & Data port interface: 530 RS-530 V35 V.35 X21 X.21 V36 V.36/RS-449 * S Optional drop-and-insert E1/T1 sublink % Optional second data port interface: 530 RS-530 V35 V.35 X21 X.21 V36 V.36/RS-449 V24 for V.24 ETQN 10/100BaseT Ethernet bridge with VLAN support SUPPLIED ACCESSORIES Power cord and AC/DC adaptor plug The following cables are supplied for each data port interface specified for operating in DCE clock mode: CBL-HS2/V/1 for 34-pin V.35 CBL-HS2/R/1 for 37-pin V.36/RS-449 CBL-HS2/X/1 for 15-pin X.21 OPTIONAL ACCESSORIES RM-33-2 Hardware for mounting one or two units in a 19-inch rack CBL-DB9F-DB9M-STR Control port cable CBL-RJ45/2BNC/E1/X RJ-45 to BNC adaptor cable (for unbalanced main link interface) CBL-RJ45/2BNC/E1 RJ-45 to BNC adaptor cable (for unbalanced sublink interface) CBL-HS2/*/# Adaptor cables for DB-25 channel connectors, for operation in the DTE1 and DTE2 clock modes Legend * Interface, clock mode: V/2 34-pin V.35, DTE1 V/3 34-pin V.35, DTE2 R/2 37-pin V.36/RS-449, DTE1 R/3 37-pin V.36/RS-449, DTE2 # Cable connector type F female M male 389-100-12/07 Specifications are subject to change without prior notice. 1988 2007 RAD Data Communications Ltd. All other trademarks are the property of their respective holders. International Headquarters 24 Raoul Wallenberg Street Tel Aviv 69719, Israel Tel. 972-3-6458181 Fax 972-3-6498250, 6474436 E-mail market@rad.com www.rad.com North America Headquarters 900 Corporate Drive Mahwah, NJ 07430, USA Tel. 201-5291100 Toll free 1-800-4447234 Fax 201-5295777 E-mail market@radusa.com The Access Company