SHIMPO INSTRUMENTS. ST-320BL LED Stroboscope Array Operation Manual

Similar documents
ST-329 LED Stroboscope Array Operation Manual

Operation Manual DT-326. LED Stroboscope

Model DT-315P DIGITAL STROBOSCOPE INSTRUCTION MANUAL

DT-900 Techstrobe Operation Manual

SHIMPO INSTRUMENTS. FG-7000T Digital Torque Gauge Operation Manual

FG-7000 Digital Force Gauge Operation Manual

TTC Series Torque Tool Tester Operation Manual

FG-7000L Digital Force Gauge Operation Manual

NIDEC-SHIMPO INSTRUMENTS

FG-3000R Digital Force Gauge Operation Manual

FG-3000 Digital Force Gauge Operation Manual

-Direct.com FG-3000 Digital Force Gauge Operation Manual

Series FGE-XY Force Gauges Operation Manual

NIDEC-SHIMPO INSTRUMENTS

NIDEC-SHIMPO INSTRUMENTS

Cheetah Light LLC. (214) Instruction Manual

DT-311J Digital Stroboscope Operation Manual

Pocket LED Strobe Portable LED Stroboscope

A4950 Stroboscope pocket guide

Pressure Switch CE40. Digital settings available via IR data communication without actually applying pressure to the unit

Operating Manual. AdirPro HV8RL Red Beam Horizontal/Vertical Laser level

E102 - Advanced Strain Gauge Transducer Display Interface. Contents

CALOG CALOG - LC DISPLAY. Loadcell Display. English Users Manual. Rev. 1.10

impact INSTRUCTIONS LiteTrek 4.0 Monolight lighting equipment and accessories

E101 - Strain Gauge Transducer Display Module. Contents

MONARCH INSTRUMENT. TACH-4A / TACH-4AR Programmable Optical Tachometer. Instruction Manual Rev 2.0

Model ST-FT1 DIGITAL FORCE / TORQUE INDICATOR. User s Guide

TEL: / FAX:

Absolute Encoders Multiturn

TITAN S8. Portable Data Acquisition Logger. Product User Guide

Rackmount LCD Console - 1U - 17in Screen - US Keyboard p

LDM M LASER DISTANCE MEASURER

Cheetah Light LLC. (214) Instruction Manual

Fast-charge your mobile devices

Nova-Strobe DBL and Nova-Strobe PBL Deluxe and Phaser LED Stroboscopes

Instruction Manual. Electronic Horizontal & Vertical Self-Leveling Rotary Laser Level Model Nos , ,

Nova-Strobe DBL and Nova-Strobe PBL

1U 17" HD 1080p Dual Rail Rackmount LCD Console w/ Fingerprint Reader and Front USB Hub

Revo 120. User Manual

HCS-3600 / 3602 / 3604 Laboratory Grade & High RFI Immunity Switching Mode Power Supply with Rotary Encoder Control

Nova-Strobe PBL Deluxe and Phaser LED Stroboscopes

Nova-Strobe BBL Basic Battery LED Stroboscope

HDAF800 HD 1080p Digital Microscope USB drive for Image Capture

2 Product Overview. 5 User Interface. 14 Logging Data. 17 Viewing Data. 19 Managing Data. 24 Device Settings. 26 Specifications.

USER MANUAL Video Particle Counter with built in Camera Model VPC300

PIECAL 322 Automated Thermocouple Calibrator Operating Instructions. Product Description. Practical Instrument Electronics

TNP Digital Torque Meter Operation Manual

VPC-64/ VPX-64 VIDEO POLE CAMERA OPERATION MANUAL

LED Accu Penta 9x12W RGBWAU

Dimensions. Outline. Features. Accessories. HD VD External Sync. C Lens Mount. BLACK-and-WHITE VIDEO CAMERA MODULE XC-EU50/EU50CE.

NTP-5521/5531/5561 SWITCHING MODE POWER SUPPLY

ADC7520 SERIES. 1600W Battery Chargers and Power Supplies

Anemometer SD Card Datalogger. Instruction Manual

Installation and Operation Back-UPS BR1000G-IN / BR1500G-IN

Digital Torque Tester

PM-204A/B. Power Meter. Operation Guide

Visible Light SD Card Datalogger

Tech doc ENGLISH Infinity ib-16r Ordercode: 41532

Introduction CLASS 1 LED PRODUCT

10-Port USB 3.0 Hub with Charge and Sync Ports - 2 x 1.5A Ports

5.6" Multi-function Monitor

interfit S1 Battery-Powered TTL/HSS Flash

Track-It Pressure Logger with Display and Current Transmitter

Delivery. Connection. C. AA+BB Helicoidal cable 2. Radial M12 8p CCW. 3. Radial M23 12p CCW

CONTROL MICROSYSTEMS High Speed Counter Input Module. Hardware Manual

XC-EU50/EU50CE. Dimensions. Outline. Features HD VD. C Lens Mount B/W VIDEO CAMERA MODULE. 1/2 Type CCD. VS Output 44 XC-EU50/EU50CE.

RH/Temperature SD Card Datalogger. Instruction Manual

Dual 4K Monitor Mini Thunderbolt 3 Dock with HDMI

Instruction Manual Pocket LED Strobe Portable LED Stroboscope

Digital Torque Screwdriver

USER MANUAL. IST channel speed calibrator

User s Guide. OM-CP-PRHTEMP2000 Pressure, Humidity and Temperature Data Logger with LCD

Back-UPS RS 550 Installation & Operation

Nearus USB2.0 Camera Manual NU-350-USB2PTZ-B

PIECAL 520B & 521B Thermocouple Source Operating Instructions

USB-C Multiport Adapter for Laptops - 4K HDMI - GbE - USB-C - USB-A

Temperature & Humidity Datalogger

Installation and Operation Back-UPS Pro 900

X-Beam Waterproof Action Camera Light USER GUIDE

UMTI [UMTI USER MANUAL] User s Manual. Handheld Surveillance Thermal Camera

testo 476 Instruction manual 99 Washington Street Melrose, MA Phone Toll Free Visit us at

TPE 1464 Series Pressure Transducer

Refurbished 1U 19in Rackmount LCD Console with Integrated 8 Port KVM Switch

PM-100 SERIES. Operation Guide. Power Meter V

SCHOTT FLM 4 Fiber Lighting Modul. Operating Instructions


7511 / / / 711 / / 731 / Preset 27

SORDS ELECTRIC ~ MA7200. Sensorless Vector AC Inverter.

User s Guide. Series 2 DIGITAL FORCE GAUGES

DMT345 and DMT346 Dewpoint Transmitters

COT220-APK01. 22" Open-Frame Monitor with 4mm/6mm. Dust proof SAW Touchscreens. DongGuan CJTOUCH Electronic Co., Ltd. PUBLISHED DATE:

Product User Guide PR2000. PR2000 Pressure Data Logger with LCD

DTW 400/DTW Digital Torque Tester/Screwdriver User s Guide

Portable Conductivity Meter M1410. User Manual 1.002

USB-C Docking Station for Laptops - 4K HDMI - 85W Power Delivery - USB 3.0

Led Illuminator and Light Stimulator. Model # LSD-1. Ver

DTT Series Digital Torque Testers User Manual

PIECAL 510B/511B RTD Simulator Operating Instructions

USER GUIDE. Video Particle Counter with built in Camera. Model VPC300

HuddleCamHD 10X-USB2

Transcription:

ST-320BL LED Stroboscope Array Operation Manual SHIMPO INSTRUMENTS Use in flammable environments is prohibited. Use in this manner may result in fire or explosive. Don t look directly into the LED light Source. This may result in eye injury. Don t use or store in the following environments. Direct sunshine condensation, dust or caustic. Do not alter, or modify of improperly. Such action may cause damage and void warranty. Operate with 0-35 C (32-95 F), 35-85% RH. Use outside of this range may alter operation of the unit. Case may become excessively hot when used continuously for more than 2 hours. Mount unit on a tripod or other fixed device. The ST-320BL is a portable or permanent mount stroboscope. Utilizing super bright high-powered black light CREE LED lamps, these stroboscopes are perfect for UV ink printing applications. The ST-320BL s LED array provides a bright, stable strobe light over a wide measurement range with a lifetime far exceeding xenon lit stroboscopes. Operation is simple with the 8 button keypad and quick rate adjustment dial, combined with large, backlit LCD display. Phase shift, flash duration, plus flash rate are all quickly adjustable. The unit can work off user adjusted flash frequency or from a remote sensor s signal which will automatically adjust to corresponding process fluctuations. The ST-320BL is designed for speed and frequency measurements in the printing, packaging, textile, automotive, cable, mining, steel, chemical, optical and medical industries in various applications. SPECIFICATIONS Flash Rate Range: 60 to 120,000 FPM ; 1-2000 Hz Accuracy: 0.01%±1 digit of F.S. @ 77 F (25 C) Lamp Lifetime: Approximately 3~5 years depending on usage. Display: Backlit LCD Resolution: 60 ~12,000 FPM = 0.1 FPM; 12,001~120,000 FPM = 1 FPM; 1~200 HZ = 0.01 Hz; 201~2000 = 0.1 Hz Flash Duration: 0.1-2.5 Phase Shift: 0-359 Power Requirement: ST-320BL-1: 100-120 VAC; ST-320BL-2: Rechargeable Battery. Battery: (ST-320BL-2) Lithium DC 10.8V 2000mA Battery Life: (ST-320BL-2): Approx. 12 hrs depending on settings Input Signal: 12 V Pulse Input; 3 pin M-12 Input Signal Range: 60-120,000 FPM (1-2000 Hz) Input Pulse Width: Over 50 µs Input Signal Flash Delay: 0-999 ms; 0-359 Temperature Limits: 32-95 F (0-35 C) Humidity Limits: 35 to 85% RH Enclosure: Aluminum & ABS Mounting: 1/4-20 UNC Thread Enclosure Rating: IP54 Product Weight: ST-320BL-1: 1.85 lb (0.84 kg); ST-320BL-2: 1.98 lb (0.90 kg) Package Weight: ST-320BL-1: 4.40 lb (2.0 kg); ST-320BL-2: 5.73 lb (2.6 kg) Approvals: CE Warranty: 1 year Included Accessories: Carrying Case, ST-320BL-1: 6.5 (2 m) AC power cord; ST-320BL-2: Power Recharging Adapter with cord. Operation Panel Located on Control Enclosure POWER: Power on and off. MODE: Select mode of operation or Parameter Menu: Internal/ External/Parameter Settings SET: Change Units (FPM to Hz); In Parameter Menu scroll through parameter settings, Store setting values. x2: Multiplies the flash rate/frequency by a factor of 2. 1/2: Divides the flash rate/frequency by a factor of 2. RATIO: Adjusts flash duration (flash pulse width) in Internal/External modes. + : Advance image forward 3 degrees at a time in internal mode. In parameter setting mode, adjusts setting values. - : Retard image backwards 3 degrees at a time in internal mode. In parameter setting mode, adjusts setting values. Dial: Set flash rate or frequency. CW: Increase flash rate/frequency. CCW: Decrease flash rate/frequency. (Turn dial quickly to drastically change value; Turn dial slowly to change value by 1 digit.) In parameter setting mode, CW or CCW rotation changes the setting value. *Dial located on side of unit.

LCD Display Parameter Icons Sub Data Display Main Data Display Units FUNCTION INSTRUCTIONS Mode Selection - To switch between INTERNAL, EXTERNAL and PARAMETER menu, press and release the MODE key. For details about Parameter setting mode, please refer to Parameter setting menu section. Main Data Display Flash rate value will be displayed in internal flashing or External trigger mode. Display will indicate P or LCD (in ON/OFF setting of LCD backlight) in *Parameter setting mode. Internal Flashing Mode *For details about Parameter setting mode, please refer to Parameter setting mode. Sub Data Display Internal Mode Phase Shift will indicate degrees of phase shift in internal flashing mode. To change the degrees of phase shift, press + or - keys. The display will reflect the cumulative angle of phase shift. The flash duration time will be displayed when the RATIO key is pressed. The flash duration time can then be increased or decreased with the dial from 0 to 2.5 (0~2.5 ) degrees. External Mode In external trigger mode, the display will show the settings of delay time. For details about changing these settings, please see external trigger mode section. Changing Units of Measure in Internal Mode - To change the measuring units from FPM to Hz, press and release the SET key. Units will alternate with each press and release. Flash Rate (Frequency Setting) in Internal Mode - You can set the flash rate by turning the dial in the center of the unit. To increase the flash rate, turn the dial in the clockwise direction. To decrease the flash rate, turn the dial in the counter-clockwise direction. For small adjustments, turn the dial slowly. For quick adjustments, rotate the dial quickly. The flash rate range and resolution will be different according to the selected measuring range. One function of a stroboscope is to provide a stopped image of a rotating target when the flash rate of the stroboscope has matched the rotational speed of the target object. The stroboscope will show a single image when the flash rate is set to a lesser multiple of the true RPM (1/2,1/3,etc.) When the flash rate is increased to a higher multiple (2,3,etc.), multiple images will appear. To find the true RPM of the target object, reduce the flash rate to a lower multiple until only one image appears. 2

Stopped Image: Flash Duration (Brightness) Settings The flash duration, RATIO key, can be set within the range of 0.1-2.5 over a 360 period with a resolution of 0.1. 1/3 Example True Rotational Speed of Target Object (rpm) 900 rpm Flash Rate of Stroboscope (fpm) 3600 2700 1800 900 450 300 Multiple of True Rotational Speed 4 times 3 times 2 times 1 time 1/2 times 1/3 times Number of Stopped Images 4 3 2 1 1 1 When the flash duration is lengthened, the brightness of the flash will be increased, however the image of the target object may appear slightly out of focus. When the flash duration is shortened, the brightness will be decreased, yet the image of the target object will become more focused. To change the flash duration in either Internal or External modes, first press the RATIO key. Once pressed, Flash Time will appear with the current flash pulse duration ratio in the sub display. The flash pulse duration can now be modified. Multiple/Divide by 2 Function - The flash rate can be doubled or halved by x2 and 1/2 keys on the operation panel. 1. Doubling the flash rate(x2) Press x2 key to multiply the current flash rate by a factor 2. Note: The use of the x2 key will have no effect when multiplication of the current flash would result in a value that exceeds the maximum flash rate range. After the flash rate changes, it becomes the new value based on the set display resolution. Therefore, the rate may likely not return to the original frequency, even if the 1/2 key is pressed. 2. Having the flash rate(1/2) Press 1/2 key to divide the current flash rate by a factor of 2. Operation Indication To set the flash pulse duration while in the modifiable mode; press + key, or turn the dial in the clockwise direction to increase the flash pulse duration by 0.1 increments. Press - key, or turn the dial in the counter clockwise direction to decrease the flash pulse duration by 0.1 increments. Note: The use of the 1/2 key will have no effect when the division of the current flash rate would result in a value that goes below the minimum flash rate. After the flash rate changes, it becomes the value based on the set display resolution. Therefore, the rate may likely not return to the original, even after pressing the x2 key. Phase Shift (Angle) - First, press SET key, then enter this mode. When the rotation speed of the target object and the flash rate of the ST-320BL becomes equal, the phase shift function can be used to delay the flash so that the image will appear to rotate incrementally. The phase shift angle can be increased or decreased 3, each time the + or - keys are pressed or the adjustment dial is turned CW or CCW. The sub display will show the cumulative angle of the phase shift. 3

External Trigger Mode External trigger mode will allow the flash rate of the ST-320BL stroboscope to be controlled by an external signal, such that the flash rate will automatically increase or decrease when the signal is altered, so that it may remain in unison with the speed of a changing target. Connector of External Input/Output Charging round socket: positive 16V, negative 16V External synchronous USB port: 1.+12V output 2. OUT external pulse input 3.-12V output External Pulse Input: The input signal will have the following characteristics. Connector: 3 pin M-12. Input frequency: 60-12,000 fpm (1-2000Hz) Input pulse width: over 50 µs. Delay angle: 0-359 (every 1 ) Delay time: 0-999 ms (every 1ms) Note: When the external sensor is used, use the AC power adapter power supply. Additionally, there are several settings that can be adjusted in External Trigger mode, including phase shift, delay time, and flash duration. The flash timing can be set by using the positive or negative edge of an external trigger signal. Also the delay of the flash timing can be set by time in (msec) or degrees ( ). Press mode once and the unit enters EXTER 1. In this mode, frequency (HZ) or speed (FPM) automatically flash according to the external trigger signal. After setting the parameters, generally the detected object has an advanced or lag phenomenon. To adjust, press the + or - for fine-tuning, change the perimeter parameters, so that detected object achieves a still image. In this setting process, the unit will automatically save the last setting. External Trigger Mode: LCD Display Information The frequency of the external signal is measured each period, while the latest external frequency measurement is updated every 50 ms. External Trigger Flash Delay Setting A flash angle delay can be programmed into the ST-320BL to delay the flash after an external trigger signal is detected. The unit of delay can be set to time (msec) or degree ( ). Use + or - key to alternate between the settings of delay angle or delay time. Delay Time Setting The delay time can be set to incorporate a delay from the external pulse input to the flash output. The delay can be set from 0-999 ms with a resolution of 1 ms. Note: Because of the existence of a delay in internal calculation, the ST-320BL flashes 60 µs after the external signal input. This results in the actual setting delay time having approximately +60 µs added to the delay. Example Trigger: positive edge + _ Delay Time: 10 ms The ST-320BL does not flash at the 1st trigger pulse as shown below in the diagram, ST-320BL flashes from the external trigger after 10 ms. 4

If the period of the external input is less than the setting of the delay time, the delay time is ignored and the ST-320BL flashes as if the delayed time equals 0. To adjust the delay time, press the + or - key. Or turn the dial to set the delay time. Delay time will increase as the dial is turned clockwise, and decrease as it is turned counter clockwise. Delay Angle Setting As the period of the external input is 360, the delay angle can be set from 0 to 360, by every 3. Since the internal calculation time is 60 µs, the actual delay time is as follows: Delay angle setting/360 x period of external input + appox. 60 µs. The ST-320BL does not flash at the 1st trigger pulse as shown below in the diagram. Example: Trigger: positive Delay Angle: 36 36/360=10 Parameter Settings To enter parameter setting menu, press MODE until the LCD displays P. When the display shows P, press the SET key to cycle between the various parameter settings available (range, trigger edge, delay time, LCD backlight, Auto Shut-off, Initial). To store the settings and return to measuring modes, press the MODE key. Measuring Range Setting You can adjust the flash setting from the home view and also in parameter mode if desired. Trigger Edge Setting (External Modes) In external mode, the trigger edge parameter will allow for selecting either the leading edge or trailing edge of the input pulse to trigger the stroboscope flash. In parameter mode, use the SET key to cycle to the Trigger Edge setting parameter mode. To set the trigger edge as Down Edge (trailing), press - key or turn the dial clockwise. To set the trigger edge as Up Edge (leading), press + key or turn the dial clockwise. If the current period of external trigger input changes, the time of the flash is not accurate, because the time is calculated based on the previous measurement period. If the current period of external trigger input is less than the previous period and the next trigger input occurs before the flash time, the delay angle setting is ignored and the ST-320BL flashes at the delay angle=0. To adjust, press the + or - key. You may also use the adjustment dial. The delay angle increases as the dial is rotated to the right. The angle settings will go to 0 as the angle increases past 359. When trigger edge setting is set to up edge. The flash will occur on the leading edge of the input pulse (when delay setting is zero). External Pulse Signal from Machine/Sensor vs. Stroboscope Flash Up Edge When trigger edge setting is set to down edge. The flash will occur on the trailing edge of the input pulse (when delay setting is zero). External Pulse Signal from Machine/Sensor vs. Stroboscope Flash Delay angle decreases as the dial is rotated to the left. The settings will eventually go to 0 as the angle decreases past 359. Down Edge 5

Back Light Setting The LCD display of the ST-320BL stroboscope has a backlight that can be turned on or off in the parameter settings. Turning off the backlight will conserve battery power. To adjust the backlight setting, enter parameter mode and use the SET key to cycle to LCD setting. Press + key to turn on the backlight. Press - key to turn off the backlight. Mounting To mount permanently, remove the two screws holding the trigger handle. The threaded adapter will now be visible. Discard screws and handle. With appropriate 1/4-20 UNC male thread connection, attach to stroboscope s female threaded adapter. Hand tighten to secure. Note: If the backlight is set to on, as a power saving feature, it will automatically shut off after the set minutes if no keypad or dial operation has occurred. The LCD backlight will turn back on with keypad or dial operation. Automatic Power-Saving Settings Auto Power Off: The unit will automatically turn off after 1 to 1000 minutes depending on settings if no keypad or dial operation occurs when using battery power. Flashing will resume with either a dial (rotation) movement or a keypad operation. The LED auto shutoff will not occur in External trigger mode, while a signal is being received by the unit. The LED flashing will automatically turn off after the set 2 minutes of no external pulse input. LCD Back Light Off: If the backlight is set to on, as a power saving feature, it can be adjusted to automatically shut off from 1 to 1000 seconds, if no keypad or dial operation has occurred. The LCD backlight will turn back on with keypad or dial operation. Factory Reset (Initial) To reset unit to factory values choose Yes under Initial in the parameter setting mode. Then press SET.