BB5-Lite TECHNICAL MANUAL

Similar documents
Touchpad User Guide (Model: C-LCD-122-TL)

Touchpad User Guide. National Sales. Product Support. Freecall: Ph:

Measure & Control Temperature & CO2 levels with analog & digital I/O

Microprocessor based Temperature / CO2 Controller c/w 365 Day Time Switch & Modbus Communication.

TEMPERATURE CONTROLLER 2 HEAT/ 2 COOL with Digital Room Temperature Display. Made in Australia 100% Australian Owned Company

PC2004 PRESSURE CONTROLLER

Dip Switch settings.

MiG2 CONTROLLERS. 2 & 4 Stage General Purpose Controllers, with Air-conditioning Facilities

Viconics VT76x6W Water-source Heat Pump Controllers Engineering Guide Specification

M1000 INTELLIGENT ZONE CONTROL SYSTEM

INDOOR UNIT CONTROLLER (IUC) Operation Manual

FCU-4 FAN COIL CONTROLLER

FCU-4 FAN COIL CONTROLLER

INTRODUCTION. FX-1 Operations Manual. Standard Features. Optional Features. Read This Manual Completely Before Proceeding!

lnvertek Drives.com ct,ve ELECTRICAL SUPPLIERS LTD

Features and Benefits of XeteX Controls. Other Unit Control Functions. Energy Recovery Functions

RT12-240V/2.4kW Rectifier Specification

FX-2 Control Board ASY-360-XXX Setup and Configuration Guide

IQ-MP Gateway. Version apr Electrocom Rødeledsvej 95 DK-5700 Svendborg Denmark Tel :

Universal Controller

Standard Options. Model 4100 Position Indicating Meter. Three Phase Motor Control. Positran Transmitter

Temperature controller Ducted systems

AirTouch 2 Zone Control System

FCU-MULTI Modbus Fan Coil Unit Controller

TEC Heat Pump Multi-Stage Controller. Control Applications. Accessories. Product Description. Product Numbers. Warning/Caution Notation

NT10 Series RS485 Modbus RTU Networking LCD Fan Coil Thermostat

BACnet PTEC Heat Pump Multi-Stage Controller. Control Applications. Product Description. Product Numbers. Warning/Caution Notation

Temperature Controller (Heat Pumps)

Product Manual SZ2141

Fast Route to Reliable Energy Savings ZIP Economizer

Installation and Operation. Tracer MP501 Controller CNT-SVX08B-EN

32MP Gateway. Overview and Configuration Manual

FX-2 Control Board ASY-360-XXX Setup and Configuration Guide

2.) Cabinet setup and preset data shall, as standard, be fully user programmable on a per cabinet or system wide basis.

4-step Chiller and Heat Pump Controller

CONTROLLER INSTALLATION OPERATION & QUICK START

CCM-204 MULTI-PURPOSE TEMPERATURE CONTROLLER

User Guide. Multipipe Units CMAA / RTMA CNT-SVU004B-GB

IO-INTERFACE. Procon. INSTALLATION MANUAL Version 1.01 MITSUBISHI ELECTRIC FOR INSTALLERS

pco 3 Controller User Manual ASPX Digital Scroll, Air Packaged Chiller For Version MCDSV_A02

FX2-CHILLER. Digital Control. Operations Manual

ZONETOUCH DAMPER CONTROL SYSTEM Operation Manual

SMM Series 3G and GSM Modems. Quick Start Guide. Document Number: Version: 1.2 (20 October, 2015)

Custom Controller Installation Instructions

ETM-2050/ETM-2051 Service Manual

User Guide. For controller on CXAO / RTXB heat pumps CGCM / CXCM 2 circuit units. CNT-SVU005C-GB Original instructions

RT4F-120V/20A-WAC RECTIFIER

X47.CE Product Guide

RT4B-110V/12A RECTIFIER

VLT 2800 DRIVE SPECIFICATIONS

Optidrive Applications Support Library

UNIT CONTROLLER 7 (UC7) Operation & Installation. Hydronic Units

LTEC Heat Pump DDC Controller

RT4F-110V/25A RECTIFIER

RXM39.1. PL-Link IO Block. Desigo TRA. Use with PXC3 series room automation station

TAC Xenta 121-HP Programmable Heat Pump Application

Product Catalog. Tracer Controller MP501 BAS-PRC008-EN. May 2012

RWD68U Universal Controller

Suitable for a wide range of installations with wall-mount, flush-mount and hand-held remote control options.

Proportional Control Unit (PCU)

RT4F-48V/50A-WAC RECTIFIER

SSW06. Soft Starters.

System 450 Series Modular Controls

NEUROLOGIC RESEARCH CORPORATION MODEL 2500

Andover ContinuumTM Infinet II

ECON-ZIP-BASE. ZIP Economizer Base Module

Powered to Perform. Everyday Reliability. Exceptional Value. Expertise and Support

Desigo RXA Room controllers without bus communications Range overview. CA2S3880en_ Building Technologies

Application Engineering

Technote. Frese OPTIMA Compact actuators DN10-DN32. Application. Features thermic actuators. Features motoric actuators. Approval.

NT50 Series RS485 Modbus RTU Networking LCD Fan Coil Thermostat

Electrical Actuators

System 450 Series Reset Control Modules with Real-Time Clock and Relay Output

UNT1100 Series. Binary Output Jumpers AO2 AO1 AO3 AO4 AOCM AOCM AOCM AOCM AO1. AI Switches Job Information N2 Address. Ref N2+ N2- ADDR 0 = ALL OPEN

SED2 VFD NEMA Type 3R Bypass/Air Conditioner

RTD-RA. realtime. Installation Instructions. English A B. Installation Instructions Control Systems LEDS ALL DIMENSIONS IN MM

Master room unit for RRV controllers

RCF-230CAD. Communicating room controller for fan-coil applications with two analogue V DC outputs

SECTION SOLID-STATE REDUCED VOLTAGE STARTERS

Communicative controller for VAV systems

FX 2 Instruction Manual

Electrical Demand Specification (Reference SOP: )

SSW06. Soft Starters. Applications. Standard Features. Pumps Fans Blowers Compressors Crushers Saws Grinders Mixers.

MICROFUSION FEATURES OPTIONS CERTIFICATIONS (PENDING) THREE PHASE SCR POWER CONTROLLERS

SERIES CMT CARBON MONOXIDE GAS TRANSMITTER

PHASETRONICS. SCR Power Control Specialists. EP1 Series Power Control Single Phase SCR Amps OPERATION & SERVICE MANUAL

QUICK START. Installation & Programming Guide

Built-in features Built-in simplicity Built for fans & pumps

Removal of Hardware ESD, Independent of Safety Logic Solver

Indoor Unit Controller (IUC) Quick Reference and Fault Diagnosis

Tracer Controls. Tracer ZN517 Unitary Controller BAS-PRC012-EN

Supplementary operating instructions for your air curtain system Controller TMC 500

Instruction Manual CTC-1

Carrier ComfortChoice Touch ZigBee Certified Thermostat Technical Specifications

DESIGO RX Individual room controllers. for fan-coil systems, chilled ceilings and radiators, with LONMARK-compatible bus communications

Appendix C: HVAC PRO Modules

THERMOSTATS & CONTROLLERS

Room Temperature Controller

RCF-230CTD. Room controller for fan-coil applications with outputs for two thermal or one 3-position actuator or function for an electric heater

Product Catalog. Tracer Controls Tracer ZN517 Unitary Control BAS-PRC012-EN. August 2010

Transcription:

BB5-Lite TECHNICAL MANUAL Product Support 1800 354 434 CC - BB5 - LITE LITE with Plug & Play technology www.blackbox.net.au Designed by IAS in Brisbane Made in Australia Product Support 1800 354 434 www.ias.net.au support@ias.net.au National Sales 1300 306 125 sales@ias.net.au

Publisher Innovative Air Systems Pty Ltd (IAS) Phone 1300 306 125 Fax 07 3890 8270 Internet www.ias.net.au Email info@ias.net.au Revision 06.02 This Technical Reference Manual describes the specifi cations and operation of the BlackBox BB5-Lite control module. Copyright This publication is Copyright 2006 Innovative Air Systems Pty Ltd (IAS). All rights reserved. No part of this publication may be reproduced, stored in any retrieval system or transmitted, in any form or by any means, electronic, mechanical, photocopying, recording or otherwise, without the prior written permission of Innovative Air Systems Pty Ltd. Disclaimer IAS reserves the right to make changes and improvements to any of the products described in this document without prior notice. Under no circumstances shall IAS be responsible for any loss of income or any special, incidental, consequential or indirect damages howsoever caused. Warranty The contents of this document are provided as is. Except as required by applicable law, no warranties of any kind, either express or implied, including, but not limited to, the implied warranties of merchantability and fi tness for a particular purpose, are made in relation to the accuracy, reliability or contents of this document. IAS reserves the right to revise this document or withdraw it at any time without prior notice. Sourcing Proudly designed and manufactured in Australia by Innovative Air Systems Pty Ltd, an independent Australian-owned company. Product support Freecall 1800 354 434 (Australia-wide) Page 2

Contents 1 Overview 1.1 BB5-Lite Control Module...5 1.2 Personality...6 1.2.1 Personality Matrix... 6 1.2.2 Economy Cycle Controller... 7 1.3 Standard Control Settings...7 1.4 Advanced Control Settings...8 1.5 Hardware Settings...10 1.5.1 DIP switches... 10 1.5.2 Pump Override Jumper Block... 10 1.6 Universal Inputs...10 1.6.1 Message Library...11 2 Specifications 2.1 Hardware Specification...12 2.2 Dimensions...13 2.3 Hardware Layout...14 3 Connection Diagrams 3.1 311...15 3.2 122...15 Page 3

1 Overview This manual describes the specifications and operation of the BlackBox BB5-Lite HVAC controller. The BB5-Lite is suitable for use on systems utilising any of the following HVAC strategies. Direct Expansion Confi gure for either reverse cycle or electric heat. Up to 3 stages of cooling / heating. 0-10v output on cooling call for modulating zone damper. 0-10v output on heating call for time proportional heating. Chilled Water Dedicated pump call. Dedica ted proof of flow input to prevent system damage. 0-10v output for modulating chilled water valve. Staged electric heat outputs. 0-10v output for time proportional or staged heating. Water Cooled Air Cooled Pump call output. Dedicated proof of flow input to prevent system damage. Staged cooling outputs. Staged heating outputs. 0-10v output for time proportional electric heating. Staged cooling outputs. Staged heating outputs. 0-10v output for time proportional electric heating. Economy Cycle 0-10v output for modulating both outside air and return actuators Dedicated outside air sensor. Fully automatic economy change over. Staged heating output. 0-10v output for time proportional electric heating. Page 4

1.1 BB5-Lite Control Module The BB5-Lite control module is a microprocessor driven HVAC plant controller. The BB5-Lite is ideal for both stand alone (external interface module required) and networked applications (Refer to HMI Technical Manual). Features: 5 x relay outputs 2 x analog outputs 1 x digital inputs 2 x universal inputs optional programmable multi-channel annual timeclock All terminals are protected by terminal covers which are mechanically fastened. Product Support 1800 354 434 CC - BB5 - LITE LITE with Plug & Play technology www.blackbox.net.au Designed by IAS in Brisbane Made in Australia Page 5

1.2 Personality Plug and play outputs make the BlackBox series the most flexible controller in its class. The control module outputs are allocated to the appropriate HVAC plant resources according to the personality imposed on the control module during the initialisation sequence when power is applied to the controller. The BB5-Lite controller personality must be imposed by an external interface module (refer to HMI Technical Manual). If a compatible interface module is detected at initial power up, the device(s) transmits its personality to the control module, and when the initialisation sequence has successfully completed, the controller begins normal operation. A control module can support multiple interface modules [optional interface expansion module(s) may be required]. Where more than one interface is connected, they may have different interface types but must have the same personality. If a personality confl ict is detected during the initialisation sequence, the control module will enter Safety Mode and no relays will be energised until the issue is resolved. BlackBox personalities are represented by a numerical code comprising of three digits, each from the range 0-3, and an optional fourth alphanumeric character to indicate special options. The personality coding is directly referenced to the control modules relay outputs and is always in the following order: 1. Fan Outputs: The fi rst digit represents the number of fan outputs. 2. Cooling Outputs: The second digit represents the number of cooling/compressor outputs. 3. Heating Outputs: The third digit represents the number of heating/reversing valve outputs. Interface devices containing a numerical component in the product code are able to impose the corresponding personality on a control module. If relay output 5 is not assigned to cooling or heating resources, it is automatically assigned as a pump call relay. Remove the shunt from the pump override jumper block at JP1 to enable fl ow proving via the digital input. 1.2.1 Personality Matrix The following table details some common personalities for applications that are covered by the BB5-Lite. Personality Code BB5-Lite Controller Output Allocation Relay 1 Relay 2 Relay 3 Relay 4 Relay 5 003 Heat Heat Heat Unassigned Pump 1 012 Cool Heat Heat Unassigned Pump 1 013 Cool Heat Heat Heat Pump 1 013E Cool Heat Heat Heat Pump 1 021 Cool Cool Heat Unassigned Pump 1 022 Cool Cool Heat Heat Pump 1 023 Cool Cool Heat Heat Heat 030 Cool Cool Cool Unassigned Pump 1 031 Cool Cool Cool Heat Pump 1 103 Fan Heat Heat Heat Pump 1 111 Fan Cool Heat Unassigned Pump 1 112 Fan Cool Heat Heat Pump 1 113 Fan Cool Heat Heat Heat 121 Fan Cool Cool Heat Pump 1 122 Fan Cool Cool Heat Heat Page 6

Personality Code BB5-Lite Controller Output Allocation Relay 1 Relay 2 Relay 3 Relay 4 Relay 5 130 Fan Cool Cool Cool Pump 1 131 Fan Cool Cool Cool Heat 131E Fan Cool Cool Cool Heat 202 Low Fan High Fan Heat Heat Pump 1 203 Low Fan High Fan Heat Heat Heat 211 Low Fan High Fan Cool Heat Pump 1 212 Low Fan High Fan Cool Heat Heat 220 Low Fan High Fan Cool Cool Pump 1 221 Low Fan High Fan Cool Cool Heat 230 Low Fan High Fan Cool Cool Cool 301 Low Fan Med. Fan High Fan Heat Pump 1 302 Low Fan Med. Fan High Fan Heat Heat 310 Low Fan Med. Fan High Fan Cool Pump 1 311 Low Fan Med. Fan High Fan Cool Heat 320 Low Fan Med. Fan High Fan Cool Cool 1. Relay 5 is automatically assigned to pump call function. 1.2.2 Economy Cycle Controller 013E and 131E are economy cycle personalities that use outside air to provide the fi rst cooling stage when conditions are suitable. During economy mode the controller shifts the cooling relay stages 1 degree away from their normal activation points and uses the V1 (0-10V) cooling output to modulate an outside air damper. The controller will only enter economy mode if the outside air sensor is connected to the sensor 2 terminals (S2 & SC), and, the outside air temperature will assist the cooling call (S2 temperature is 2 C lower than S1 temperature). 1.3 Standard Control Settings Following is a list of adjustable settings and their default values. An external interface module is required to adjust these settings. For details refer to the HMI Technical Manual. Setpoint (Default = 22.5 C) Setpoint is the temperature the controller will try to maintain. Mode (Default = Auto) Mode controls the operating mode of the system. Select from auto, cool, heat or vent. In auto mode the controller changes from heating to cooling as dictated by the ambient conditions. Fan Speed (Default = Low) Fan Speed controls the indoor fan speed. Select from low, medium, high or auto. Auto fan decreases the fan speed as the temperature approaches setpoint. Heat Fan (Default = Continuous) Heat Fan controls the indoor fan operation in heating mode. Select from continuous or auto/cyc. Auto/Cyc causes the indoor fan to switch off between heating calls. If EDH has been selected (Refer to 1.5 - Hardware Settings) there is a fixed 4 minutes fan run on. RunTimer (Default = Disabled) Run Timer counts down run hours from a preset limit. Select a time between 10 minutes and 24 hours in 10 minute increments to enable the Run Timer. At the end of the timer period the system switches off. Page 7

SetBack (Default = Disabled) The setback function is used to maintain temperature within preset limits at all times. If the temperature moves outside these limits the controller will turn on the HVAC plant and heat or cool as required to keep the temperature within the preset limits. These limits are separate and distinct from the normal setpoint. 1.4 Advanced Control Settings Following is a list of advanced system settings and their default values. An external interface module is required to adjust these settings. For details refer to the HMI Technical Manual. Delays (Default = 4 minutes) The delay variable controls the length of time between compressor cycles - on and off. Adjustable to 4 seconds or 4 minutes (see Hardware Settings) Deadband (Default = 0 C) Deadband variable defi nes the temperature range on each side of the setpoint where no corrective action takes place. A deadband value other than 0 results in the creation of separate virtual heating and cooling setpoints, either side of the controller setpoint, offset by half of the deadband value. Adjustable in 1 C increments to maximum 3 C. 100% Deadband = 0 Setpoint System Conditioning Capacity Proportional Heating Band Proportional Cooling Band 0% Temperature 100% Deadband = X System Conditioning Capacity Proportional Heating Band Virtual Heating Setpoint = Setpoint - (X/2) Virtual Cooling Setpoint = Setpoint + (X/2) Proportional Cooling Band 0% Temperature Page 8

Control Band (Default = 0.5 C per stage) Control Band defi nes the width of the cooling and heating proportional bands of the 0-10 volt outputs. There is a separate control band for cooling and heating operation, starting from the virtual cooling and heating setpoints dictated by the deadband. For multi-stage applications the value of both the stage separation and the switching differential is equal to the control band value divided by the number of stages. 100% Deadband Virtual Heating Setpoint Virtual Cooling Setpoint System Conditioning Capacity Proportional Heating Band Proportional Cooling Band 0% Temperature 100% Stage 3 Virtual Heating Setpoint Deadband Virtual Cooling Setpoint Stage 3 System Conditioning Capacity Stage 2 Stage 2 Stage 1 Stage 1 0% Temperature Service Timer (Default = Disabled) The Service Timer monitors the system run time and at the end of the time period displays a selectable message on any external LCD interface display. Select from 0-990 hours in 10 hour increments. Universal Input message - S1 open (Default = S1 open) A message is displayed on any external LCD interface display when sensor 1 is open circuit. The default message can be replaced by one from the message library (see Universal Inputs). Universal Input message - S1 closed (Default = S1 closed) A message is displayed on any external LCD interface display when sensor 1 is closed (short) circuit. The default message can be replaced by one from the message library (see Universal Inputs). Universal Input message - S2 closed (Default = S2 closed) A message is displayed on any external LCD interface display when sensor 2 is closed (short) circuit. The default message can be replaced by one from the message library (see Universal Inputs). Service Timer message (Default = Service Required) The default message displayed on any external LCD interface display when the service timer expires can be replaced by one from the message library (see Universal Inputs). Custom message (Default = Service Required) The message library contains one entry of 2 lines of 8 characters that can be edited as required (see Universal Inputs). Page 9

1.5 Hardware Settings The BB5-Lite control module has the following hardware confi guration settings. Refer to 2.3 - Hardware Layout for the location of each. 1.5.1 DIP switches The following table details the function of the hardware confi guration DIP switches. DIP # Control module DIP/SIP switch settings Function 1 Compressor Delay 2 3 Memory Lock (Diagnostic Use Only) Restore Factory Default Settings OFF (Factory Default) Software Selectable (4 minute default) Disabled Disabled 4 Heat Type Reverse Cycle ON 4 seconds max (overrides software) Memory locked. Settings changes are discarded. Restore factory defaults at next reboot. Electric Duct Heat (EDH) or Cool Only 1.5.2 Pump Override Jumper Block Create a short circuit at jumper block JP1 using the shunt provided to override the automatic pump call function (refer to Personality Matrix for affected personalities). Remove shunt to enable fl ow proving via digital input. Proof of fl ow is required before compressor outputs can energise. 1.6 Universal Inputs Analogue inputs S1 and S2 provide additional digital inputs for feedback loops in the fol low ing manner (voltage free clean contacts required): S2 Closed Circuit = System Fault Short circuit analogue input 2 ter mi nals (S2 and SC) to shut down all conditioning relays (compressors and electric duct heaters). The fan relay will remain energised only if the system is On. For 3 speed fan models in auto fan mode the controller will default to low fan speed. Manual changes to fan speed will be accepted. LCD touchpads emit an audible warning (2 beeps every 16 seconds). Press MENU button to stop audible warning. S1 Closed Circuit = Remote On/Off Short circuit analogue input 1 terminals (S1 and SC) to shut down all relays. S1 Open Circuit = Forced Vent Mode Open circuit analogue input 1 terminals (S1 and SC) to shut down all conditioning relays (compressors and electric duct heaters), the fan and any reversing valve relays will remain energised. If the system is Off, the relay for the currently selected fan speed will be energised. For 3 speed fan models in auto fan mode the controller will default to low fan speed. Manual changes to fan speed will be accepted. All connected LCD interfaces will display a message on the screen for each digital input trigger and the service timer trigger. If multiple trigger events occur at the same time the message displayed is based on the following priority. 1. SYSTEM FAULT 2. SERVICE TIMER 3. REMOTE ON/OFF 4. FORCED VENT Page 10

1.6.1 Message Library The message library contains a selection of entries that may be used provide a clear indication of the function of each universal input. A LCD interface is required to display or alter these messages. The same message may be linked to more than one trigger. The library contains one custom entry of 2 x 8 character lines. Abbreviated version displayed on message selection screen Message displayed on screen after trigger is activated <Blank> SERVICER (Default Custom Message) DoorOpen VentMode RemoteOf RemoteSh CleanFil ServiceR (Default Service Timer Message) NoWaterF FanOverl FireShut ACPlantF HPFault LPFault HP/LPFau S1OpenCi (Default Forced Vent Input Message) S1Closed (Default Remote On/Off Input Message) S2Closed (Default System Fault Input Message) SERVICE REQUIRED Door Open Vent Mode Remote Off Remote Shutdown Clean Filters Service Required No Water Flow Fan Overload Fire Shutdown AC Plant Fault HP Fault LP Fault HP/LP Fault S1 Open Circuit S1Closed Circuit S2Closed Circuit Page 11

2 Specifications 2.1 Hardware Specification Product Code Environmental Transport Operation Temperature Range CC-BB5-Lite 0-80 C Humidity 10-80 % Temperature Range 0-50 C Humidity 10-80 % Altitude 0-2000 m Supply Voltage 240VAC ± 10% Electrical Power Supply Frequency 50-60Hz Connection Type 3 x Terminal Communications IASNet Bus - to external interfaces Connection Type Cable Type Data Refresh Rate 5 x Terminal / 1 x InnoCab socket (RJ12) 4 Core + 1 Shield / 5 Core + Shield (flat) 1s Microwire Bus - to clock module Connection Type Data Refresh Rate IDC10 1s Inputs Analogue (see 2.1.1 - Universal inputs) Digital Number 2 Type NTC Thermistor - 47 kω @ 25 C Connection Type Cable Type Data Refresh Rate 2 x Terminal 2 Core + 1 Shield Number 1 Connection Type Operation 1s 2 x Terminal Latched Mode (Close for fl ow - Open for no fl ow) Number 5 Outputs Relay Maximum Load Connection Type Status Indication 7 A (Inductive) 3 x Terminal (Common, Normally Open, Normally Closed) External LCD interface or software HMI Annual Timeclock Analogue Number 2 Type 1 x 0-10 VDC spanning cooling Control Band 1 x 0-10 VDC spanning heating Control Band Optional Physical Characteristics Enclosure Material Weight Dimensions ABS 560 g 174 (L) x 117 (W) x 56 (H) Page 12

2.2 Dimensions 116.5 112.0 92.5 55.4 39.6 150.0 161.9 174.0 35.5 57.2 29.0 Product Support 1800 354 434 CC - BB5 - LITE LITE 77.4 92.0 with Plug & Play technology www.blackbox.net.au Designed by IAS in Brisbane Made in Australia Mounting lugs are easily removed to reduce package size for switchboard mounting. Page 13

2.3 Hardware Layout ON 1 2 3 4 Analogue output terminals. Universal input terminals. Product Support 1800 354 434 CC - BB5 - LITE Hardware configuration DIP switches. Optional clock socket. LITE with Plug & Play technology www.blackbox.net.au Designed by IAS in Brisbane Made in Australia Digital input terminals - Short circuit for flow. Green LED indicates flow proved. JP1 - Pump override jumper block. Open circuit to enable proof of flow via digital input. IASNet terminals. IASNet InnoCab connection. Relay output terminals - Common, Normally Closed and Normally Open. 240 VAC Line in terminals. Refer to Connection Schematics for connection details. Page 14

3 Connection Diagrams 3.1 311 The following connection diagrams detail two typical applications of the BB5-Lite. IASnet RJ and terminals, digital and analogue input / output terminals Optional Touchpad D1 D2 V- V+ Hardware Configuration DIP switches Return Air Sensor Analogue Output Common Analogue Output 1 0-10V Cooling Ramp Analogue Output 2 0-10V Heating Ramp SH D1 D2 V- V+ I1 IC ON SH S1 SC S2 VC V1 V2 IASNET RJ JP1 240VAC Line in and relay output terminals 240V AC Maximum load through each relay is 7 A (inductive) A1 N1 E1 C1 R1 Q1 C2 R2 Q2 C3 R3 Q3 C4 R4 Q4 C5 R5 Q5 240V Active 240V Neutral Earth Fan Control Active Low Fan Medium Fan High Fan Cool Control Active Compressor Heat Control Active Rev. Valve / EDH 3.2 122 IASnet RJ and terminals, digital and analogue input / output terminals Optional Touchpad D1 D2 V- V+ Hardware Configuration DIP switches Return Air Sensor Analogue Output Common Analogue Output 1 0-10V Cooling Ramp Analogue Output 2 0-10V Heating Ramp SH D1 D2 V- V+ I1 IC ON SH S1 SC S2 VC V1 V2 IASNET RJ JP1 240VAC Line in and relay output terminals 240V AC Maximum load through each relay is 7 A (inductive) A1 N1 E1 C1 R1 Q1 C2 R2 Q2 C3 R3 Q3 C4 R4 Q4 C5 R5 Q5 240V Active 240V Neutral Earth Fan Control Active Fan Cool Control Active Compressor 1 Compressor 2 Heat Control Active Rev. Valve / EDH 1 Rev. Valve / EDH 2 Page 15

Product Support Freecall 1800 354 434 www.ias.net.au support@ias.net.au National Sales Phone: 1300 306 125 sales@ias.net.au Designed and manufactured in Australia by Innovative Air Systems Pty Ltd