DECam PFC Power Distribution Chassis (Production Version)

Similar documents
Smoke Detection and AC Power Distribution / Interruption for NOνA Near Detector Surface Building Electronics Racks

Electrical Demand Specification (Reference SOP: )

SPECIAL INSTRUCTIONS FOR CAPACITORS COMPACT GENERATORS

Installing the Cisco AS5400XM Universal Gateway

Cisco CRS 16-Slot Chassis Power Systems

1993 SPECIFICATIONS CSJ , ETC. & SPECIAL SPECIFICATION ITEM 6132 ARTERIAL TRAFFIC MANAGEMENT SYSTEM

Site Preparation CHAPTER

ANT CNTR DC ALRM LNB RX DC ALRM +18V OFF

User's Manual: A LD360 DMX LD360 DMX HP. Rev. 1.0 Software Version 1.0 1/17/95

SED2 VFD NEMA Type 3R Bypass/Air Conditioner

User s Manual. ACS550-PD Stock 3R Irrigation Packaged Drive Supplement to ACS550-U1 User s Manual

Basketball Shot Clock Set LX2180 Manual

Connecting a Cisco Output Module

Chassis Power Supplies

PFC Mini TM Power Factor Corrected AC-DC Switchers

STATE OF NEW JERSEY BUREAUS OF ITS ENGINEERING AND SAFETY & DATA DEVELOPMENT DEPARTMENT OF TRANSPORTATION TRENTON, NEW JERSEY 08625

Installation & Operation Guide

3a. IEM Indoor Metal Clad Medium Voltage Switchgear 25KV a. Section INDOOR METAL CLAD MEDIUM VOLTAGE SWTICHGEAR (Std.

This Datasheet for the IC670MDL VDC Pos/Neg Logic Input 16 Pt. Grouped.

4/8/ nd Annual OTCO WW Workshop W/WW Product Overview ACQ550. ABB Slide 1

Enhanced Mini-Chansim Model VCS-232

9926 Series Branch Rated Circuit Breakers AC Version

SECTION WIRING DEVICES

CDN502 HIGH DENSITY I/O ADAPTER USER GUIDE

Overvoltage Protection

RE-82 RACK MOUNT DIMMER OWNERS MANUAL. 8 X 2400Watts. Revision /29/2007

Research Concepts RC2500 Antenna Interface Unit (AIU) Board Set

P522 Signal Processor

Switched Mode Power Supply Operating manual PAP800

PDI Modular Compact Remote Power Panel

MFJ-1164B AC Line RFI Filter

SECTION WIRING DEVICES PART 1 - GENERAL 1.1 RELATED DOCUMENTS

MULTI 9 System Catalog UL Recognized NC100H Supplementary Protectors

MONITOR Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free

Installing Power Modules

Model DMX8DIM Installation and Operations Manual

MULTI 9 System Catalog UL Recognized C60N Supplementary Protectors

ASCO 920 Remote Control (RC) Switches

This Datasheet for the IC697CHS790. Rack, 9 Slots, Rear Mount.

MAJOR VA Power Inverter

Instruction Manual HPH-8

Uninterruptible Power Supplies

Emery County Senior Center Green River 06/07

This Datasheet is for the IC693CBL300. I/O Bus Expansion Cables.

Two-hand relay modules SRB 201ZH 44 Schmersal Industrial switching systems

AVR Manual. Isolate. Restore. Inspire! Audio / Video Power Isolation Units with Automatic Voltage Regulation. 19 Pro Series Rack Mount (RM) Faceplate

Digital Lighting Systems, Inc.

Junos WebApp Secure 5.0 Hardware Guide

FX-2 Control Board ASY-360-XXX Setup and Configuration Guide

920 Remote Control (RC) Switches

PV Rapid Shutdown device

Rack- and Panel-Mount Power Distribution Units (PDUs)

PIX 515/515E. PIX 515/515E Product Overview CHAPTER

MAXIMA + Series ROTARY LEVEL CONTROL

M5 and M10 Routers Power Supply and Power Cord Component Replacement Instructions

CDN503 HIGH DENSITY I/O ADAPTER USER GUIDE

SIMATIC. ET 200S distributed I/O Power module PM-E DC24..48V/AC V (6ES7138-4CB11-0AB0) Preface. Properties 1. Parameters 2.

Instruction Manual. Electrical Management System (EMS) EMS-HW30C & EMS-HW50C

Basics of Industrial Electricity and Troubleshooting Electrical Control Circuits

E-Series General Specifications

Surge Protection for Surveillance Systems

G5 PDU Installation Guide

2.) Cabinet setup and preset data shall, as standard, be fully user programmable on a per cabinet or system wide basis.

EA500. Installation Instructions Transponder

NetSure 802 SERIES DC POWER SYSTEM

4300 WINDFERN RD SUITE 100 HOUSTON TX VOICE (713) FAX (713) web: IMPORTANT!!!

Strand Lighting Specification

PGR-6101 MANUAL GROUND-FAULT & INSULATION MONITOR

Model Number Electrical Compatibility Module Connector Type M LL-S22 M LL-S22-NA M LL-S23 M LL-S23-NA

Advanced Distribution Cable Junction Box For Spectra RMS Molded-Case Circuit Breakers with Advanced Feature microentelliguard TM Trip Units

alid portable power cart epcc panel ccts EPCC-60 40" 60A, 120/208V 3PH 24 EPCC " 100A, 120/208V 3PH 24

Owner s Manual. Isolate. Restore. Inspire! Power Conditioners Audio / Video Power Isolation Units Rack Mount / Consumer Series

Integrated Battery Control System LBCS Step-by-Step Setup Guide

Type VR Electrically Operated Ground and Test Device

AC-DC Converter REC K10

Power Supply Installation

Electrical Integration of PV Systems. Ridha Hamidi, Ph.D.

User s Manual. ACS550-PD 3R Irrigation Packaged Drive Supplement to ACS550-U1 User s Manual

DTS 310. DIN Rail Mounted, Indoor Rated Revenue Grade Electrical Sub-meter. Page 1. Measurlogic MQ A

IES User Manual. 8 FE + 1 MM SC Unmanaged Switch -40 to 75, DIN-rail. v

Model 7705 Control Module

PGR-4300 MANUAL GENERATOR GROUND-FAULT RELAY

This Datasheet for the IC670MDL VDC Pos/Neg Logic Input 16 Pt. Grouped.

Rack- and Panel-Mount Power Distribution Units (PDUs)

IMS Control & EPR, We keep your motors running ABB s new control & protection devices up to 18.5 kw / 20 hp

The General Provisions of the Contract, including General, Supplementary and Special Conditions, apply to the work specified in this Section.

Innovative Circuit Technology Ltd.

OTPC 150/225/260 Amp Transfer Switch

CLR-102 CAMERA LINK REPEATER. User s Manual. Document # , Rev 0.1, 11/26/2010 (preliminary)

Single Phase Systems-North American PC125/PC420 Series

Control IT. Features and Benefits. Overview. Modular Power System III. Inputs: 120/240 VAC or 125 VDC power feeds allowing mixed AC and DC operation.

TECHNICAL PRODUCT DATASHEET

STATUS Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free

ELECTRO-MECH SCOREBOARD CO.

PGR-3200 MANUAL INSULATION MONITOR

Wiring diagrams. Content. Information for reading and graphic symbols... 5/2. Wiring diagrams of the circuit-breakers... 5/3

SLATE. Digital I/O Module INSTALLATION INSTRUCTIONS R8001D4001

Introduction Circuit Protection

MG24434 Supplementary Protector SUPPLEMENTARY PROTECTOR, 240VAC, 16A, CIRCUIT BREAKER TYPE: STANDARD

This document describes the procedure for doing a power trace on the SM5 and Gauntlet Stepmills.

Transcription:

DECam PFC Power Distribution Chassis (Production Version) Steven Chappa 04 October 2011 (Revised: 24 November 2011) General Description: The chassis described is used for delivering AC and DC power to the DECam s Prime Focus Cage (PFC) during normal operations when mounted on the 4-meter Blanco telescope. The primary AC power input is from a dedicated 3-phase, 208/120 VAC, 30-Amp circuit. From this input, multiple 120 VAC single-phase branch circuits are distributed and dedicated to power various electronic and utility equipment within the PFC. Also, five dedicated DC supply voltages, with provisions for a spare DC power output, are generated and distributed to dedicated pieces of equipment. In addition to the power distribution, there are provisions included to allow for remote power cycling of several circuits, the remote monitoring of various status voltages via LEDs, and an interlock feature which is determined by a series of up to three smoke detectors. Power Input: The input power is supplied to the Power Distribution Chassis (PDC) by a dedicated 208/120 VAC, 30-Amp circuit fed from a safety shut-off switch box. A shielded power cable, divided into three segments for a total of 275 feet, is used to transport this power. Input to the chassis is via a Hubbell twist-lock inlet connection rated at 30 amps. Also, since power is transported to the PFC via a shielded, continuous-flex power cable, the cable s shield is connected to the chassis main ground bus bar using a bolted connection. All power and grounding connections, under normal operation conditions, for the PFC, is implemented through this cable s conductors and shield connection. From the power input connector, the three-phase power is directly connected to a three-phase surge suppressor (with the appropriate supplemental protection device) and to a three-phase inline power filter with earth choke. From the output of this filter, the power is split up into two, dedicated, 120VAC single-phase circuits and to the 3-pole main circuit breaker with interlock (under-voltage release) function. Main power cable: Igus Chainflex shielded power cable, 4-conductor with Ground, 8- AWG, Part No. CF31-100-05 Two segments at 125 feet each. End power cable: Igus Chainflex shielded power cable, 4-conductor with Ground, 10-AWG, Part No. CF31-60-05 One segment, reduced diameter, 25 feet 1

Chassis connector: Cable connector: Hubbell Twist-Lock flanged inlet, 30-amp, 120/208VAC, Hubbell part No. HBL2815, NEMA configuration L21-30P Hubbell Twist-Lock power cord receptacle, 30-amp, 120/208VAC, Hubbell part No. HBL2813, NEMA configuration L21-30R AC Power Circuits (interlocked): There are 9 dedicated 120 VAC branch power circuits within the chassis. Each circuit has its own branch circuit breaker and the circuit number below indicates the breaker s position as looking from left-to-right as seen on the PDC s inner panel. All of the circuits below are through the main 30-amp circuit breaker and thus are interlocked. Descriptions below indicate the Circuit Breaker (CBxx) designation and the Bulkhead Outlet (BOLxx) connector designation as listed in the schematic. AC circuit 1: AC circuit 2: AC circuit 3: AC circuit 4: AC circuit 5: AC circuit 6: AC circuit 7: For FEE crate 1, 120 VAC single-phase with a 10-amp breaker, Powers a single Hubbell miniature Twist-Lock bulkhead mount receptacle, 125 VAC at 15-amp, Hubbell Part No. HBL7954, (CB3, BOL5) For FEE crate 2, 120 VAC single-phase with a 10-amp breaker, Powers a single Hubbell miniature Twist-Lock bulkhead mount receptacle, 125 VAC at 15-amp, Hubbell Part No. HBL7954, (CB4, BOL6) For FEE crate 3, 120 VAC single-phase with a 10-amp breaker, Powers a single Hubbell miniature Twist-Lock bulkhead mount receptacle, 125 VAC at 15-amp, Hubbell Part No. HBL7954, (CB5, BOL8) For FEE HTR crate, 120 VAC single-phase with a 10-amp breaker, Powers a single Hubbell miniature Twist-Lock bulkhead mount receptacle, 125 VAC at 15-amp, Hubbell Part No. HBL79, (CB6, BOL7) Powers the seven DC power supplies, 120 VAC single-phase circuit with a 10-amp breaker, (CB7) AC power for three cooling fans/exchangers within the PFC, 120 VAC with a 6-amp breaker. Powers a single Hubbell miniature Twist-Lock bulkhead mount receptacle, 125 VAC at 15-amp, Hubbell Part No. HBL79, (CB8, BOL10) Auxiliary AC power, 120 VAC with a 10-amp breaker, Powers a set of two NEMA 5-15R bulkhead receptacles (Cooper 4Q3V3) rated at 125 VAC at 15-amp. Circuit also is controlled by a solid state relay (rated for 120/240 VAC at 25amp) for remote power cycling, (CB9, BOL3, BOL4) 2

AC circuit 8: AC circuit 9: Diagnostic/Instrument AC power, 120 VAC with a 10-amp breaker, Powers a duplex outlet receptacle (NEMA 5-20R) mounted in the inner panel (access only with the cover down), (CB10, DOL1) AC power dedicated for a piece of equipment called F8, 120 VAC with a 10-amp breaker. Powers a single Hubbell miniature Twist-Lock bulkhead mount receptacle, 125 VAC at 15-amp, Hubbell Part No. HBL79, (CB11, BOL9) AC Power Circuits (direct): There are 2 additional dedicated 120 VAC branch power circuits within the chassis. These circuits listed below are NOT through the main 30-amp circuit breaker and thus are NOT interlocked. The branch circuit breakers are fed directly from the 3-phase filter output via 10- AWG wire. Again, the Circuit Breaker s (CBxx) designation is indicated as looking from left-toright on the PDC s inner panel. AC direct circuit 1: Internal control DC power supply and the chassis cooling fan, 120 VAC with a 2-amp breaker, Powers the 24 VDC power supply, maximum output current of 4.3 amps, that is used for the smoke detector interlock and for the remote power cycling and monitor functions, (CB1) AC direct circuit 2: Non-interlocked, auxiliary AC power, 120 VAC with a 10-amp breaker, Powers a set of two NEMA 5-15R bulkhead receptacles (Cooper 4Q3V3) rated at 125 VAC at 15-amp, (CB2, BOL1, BOL2) DC Power Circuits: There are 7 separate DC power supplies that supply output power for six dedicated DC output circuits. Four of them have a maximum output current of 4.3 amps. One supply provides 36 VDC and the other three provides 24 VDC. All have isolated DC outputs. The three smaller DC power supplies have a maximum output current of 2.1 amps and they also have isolated outputs. DC circuit 1: DC circuit 2: Labeled Shutter PWR (CC4), 36 VDC at 4.3 amps. Powers an output connector used for the shutter controller, circular bulkhead connector, 6- socket (contact rating is 5 amps), circuit output controlled by a solid state relay (Crydom DC60S5, rated for 60 VDC at 5 amps) for remote power cycling. Labeled Filter Control PWR (CC5), 24 VDC at 4.3 amps, Powers an output connector used for the filter changer controller, circular bulkhead connector, 6-socket (contact rating is 5 amps), circuit output controlled by 3

a solid state relay (Crydom DC60S5, rated for 60 VDC at 5 amps) for remote power cycling. DC circuit 3: DC circuit 4: DC circuit 5: DC circuit 6: Labeled Compact RIO PWR (CC6), 24 VDC at 4.3 amps, Powers an output connector used for a NI crio instrumentation crate, circular bulkhead connector, 6-socket (contact rating is 5 amps), circuit output controlled by a solid state relay (Crydom DC60S5, rated for 60 VDC at 5 amps) Labeled Compact FP PWR (CC7), 24 VDC at 4.3 amps, Powers an output connector used for NI cfp instrumentation crate, circular bulkhead connector, 6-socket (contact rating is 5 amps), circuit output controlled by a solid state relay (Crydom DC60S5, rated for 60 VDC at 5 amps) for remote power cycling. Labeled Focal Plate Photodiode Power (CC8), +/-12 VDC at 2.1 amps, Powers an output connector used for the photodiode detectors within the Imager vessel, circular bulkhead connector, 6-socket (contact rating is 5 amps). Circuit output is NOT controlled by a solid state relay. Thus, cannot be remotely power cycled. Labeled BCam or Auxiliary Power (CC9), +24 VDC at 2.1 amps, Powers an output connector originally intended for the BCam DC power. If not used, it can be used as a spare 24 VDC power source. Circular bulkhead connector, 6-socket (contact rating is 5 amps), circuit output controlled by a solid state relay (Crydom DC60S5, rated for 60 VDC at 5 amps) for remote power cycling. Interlock Function: The main 3-pole circuit breaker is equipped with an under-voltage release that operates at 24 VDC. The interlock is provided through a series of up to three smoke detectors. The detector bases are equipped with auxiliary relay contacts that change upon an alarm. The relays are connected in series to provide a return path for the 24 VDC interlock control voltage. Any one detector that detects smoke will break this return path and thus drop the interlock, tripping the main breaker. If a smoke detector is not used, a shorting plug must be used to maintain the circuit s return path. Since the smoke detector base relay contacts are rated for 2-amps maximum, the interlock circuit power within the chassis is protected using a 2-amp slow-blow fuse (F1). The interlock function can be disabled through the use of a SPDT locking lever switch. In the DISABLE position, the switch will short the path of the series-connected relay contacts and thus provide a continuous path for the under-voltage relay s control voltage. Note: The 24 VDC control voltage power supply and the direct AC circuit output (AC direct circuit 2) will not be affected by the interlock being dropped. 4

Remote Power Cycling Function: One AC power branch circuit (AC circuit 7) and five DC power circuits (DC circuits 1-4, and 6) are controlled using a set of six solid state relays (described above). These SSR control circuits route the SSR s return path of the control voltage through the remote cable connector. Another chassis, called the Power Distribution Control Chassis (PDCC), contains locking-lever SPDT switches (one for each controlled output) and these are used to control this return path. The PDCC s switch is moved in the UP position to complete this return path (to enable the output) or moved in the DOWN position to break this return path (to disable the output). In this way, the direct 24 VDC control power is not directly connected to the cable conductors and thus limit the possibility of a direct short. The cable used is a 13-pair, 24-AWG shielded cable. The remote functions can also be enabled or disabled through the use of the two 3PDT locking lever switches accessible via the PDC s inner panel. Each switch controls the operation of three SSRs (three SSRs on the top mounting plate, Plate1, and three SSRs on the bottom mounting plate, Plate2). In the DISABLE position, the switches provide a direct return path for the SSR control voltage and thus bypassing the remote cable connection to the PDCC. In the ENABLE position, control of the SSR s control voltage return path is routed through the remote cable connection and thus to the PDCC. It is important to note that the individual DC and AC power circuits cannot be power cycled individually when the remote power cycling switches, on the PDC inner panel, are in the DISABLE position. For example, the 24 VDC power for the Compact RIO slow controls crate cannot be power cycled individually. This feature exists only when the power distribution control chassis (PDCC) unit is connected to the power distribution chassis (PDC). Remote Monitoring Function: There are nine LEDs, mounted on the Power Distribution Control Chassis (PDCC) front panel, that monitor the state of all six of the DC output voltages of the Power Distribution Chassis (PDC) and three internal control voltages. These three internal control/status voltages are: 1) the under-voltage release control voltage status, 2) the status of the control voltage s power supply output, and 3) the status of the surge suppressor s operation (via a set of relay contacts). Each monitoring or output voltage connection to the remote control/monitoring cable connector is through a resistor (appropriately sized for the supply voltage) that enables an LED, mounted in the remote control/monitoring chassis, to be driven. Thus, there is no direct connection of any cable conductor to a power supply output. However, in the remote chance a direct supply output contact is made to a cable conductor, the conductor size is 24-AWG and the maximum available DC current is 4.3 amps. Therefore, no conductor fusing is implemented. 5

To Turn ON or Power Up: 1) If connecting up the main AC power cord, make sure that all breakers in the OFF position. Plug in the 3-phase power cord in the inlet connector and connect up the shield strap to the grounding block. 2) Turn ON the surge suppressor s 4-pole protection breaker. 3) Move the Smoke Detector Interlock switch to the DISABLE position. 4) Turn ON the control/interlock breaker labeled CNTR PWR SUPP. The cooling fan should now be running. Note: This CNTR breaker must remain ON at all times. If this breaker is turned OFF, the PDC s control DC power supply s output will go to zero volts and this will cause the under-voltage release relay to trip the main 3-pole breaker. 5) Turn ON the main 3-pole breaker. 6) If the smoke detector interlocks function is not desired or needed, leave the Smoke Detector Interlock switch in the DISABLE position and proceed to step (7). If the interlocks function is desired, at this time, move the interlocks switch to the ENABLE position. The Main breaker should still be ON. If it trips, there may be a problem with the smoke detectors (cable not hooked up) or with the interlock circuit. 7) Now, turn ON the branch circuit breakers as needed. Note: To remotely cycle the DC power output circuits or the interlocked AC power circuit, move the Remote Power Cycle switches to the ENABLE position. The SSR Plate1 switch enables the outputs for the 1) shutter, 2) filter changer controller, and 3) the Compact RIO crate. The SSR Plate2 switch enables the 1) Compact FP crate, 2) BCam or Auxiliary DC power, and 3) interlocked AC circuit 7. This will enable the individual power cycling of the described circuits. However, if the remote control/monitoring cable is not plugged in or the PDCC is not utilized, the power will not be present at the outputs. If remote power cycling is not desired, leave the switches in the DISABLE position. To Turn Power OFF: 1) Turn OFF all the branch circuit breakers FIRST. 2) Turn the main 3-pole breaker OFF. 3) Lastly, turn OFF the CNTR breaker. 6

To Clear a Smoke Detector Interlock Trip: 1) Turn OFF the 2-amp CNRT breaker to cut power to the smoke detectors. Wait 5 seconds. 2) Turn OFF all the branch circuit breakers. The Main breaker should already be in the OFF position from the trip. 3) Proceed with the Power Up procedure described, starting with step (3). 7

Power Distribution Chassis Assembly and Panel Pictures: AC Power Inlet: Power Filter Output: AC Outlet Wiring: AC Outlet Wiring: Main Circuit Breaker: Branch Circuit Breakers: 8

Solid State Relay Wiring: Controls Wiring: Finished Inside Wiring: Inner Panel Mounting: Inlet Side of PDC: Power Outlet Side of PDC: 9