ekorrps MULTIFUNCTIONAL PROTECTION UNIT CONFIGURATION AND GENERAL CHARACTERISTICS LIB

Similar documents
ekorsoft CONFIGURATION SOFTWARE FOR PROTECTION AND INTEGRATED CONTROL UNITS

ekor.rps Multifunctional protection unit Volume 3 of 3: ekor.rps-tpc General instructions IG-150-EN, version 04, 03/10/16 LIB

INTRODUCTION. The PL-50 MO and PM-250 families represent the. PM-250-H: Horizontal box. PM-250-V: Vertical box

INGEPAC DA-CU. Control Unit. Data Sheet ZY8932IMA01E 31/03/2016

Residual overvoltage relay

Relion 611 series. 611 series Type Test Certificate

Earth-fault Relay SPAJ 110 C. Product Guide

Sensitive Earth-fault Relay SPAJ 111 C. Product Guide

Arc protection relay. Features Three-phase overcurrent function. Application

Voltage regulator. SPAU 341 C 1MRS MBG Issued: July 1998 Status: Revised Version: C/ Data subject to change without notice

ekor.stp Programmable transfer unit General instructions IG-164-EN, version 04, 06/04/2017 LIB

AI561 Analog Input Module

TF501, TF521 Terminal Bases

Communication Gateway COM 610. Product Guide

RTU511. Binary Output 23BO62. Characteristics. Application. Data Sheet Binary Output 23BO62. The binary output is made via relay contacts.

AO561 Analog Output Module

INSTRUCTION MANUAL TRIP CIRCUIT SUPERVISION RELAY GKAD1

DI572 Digital Input Module

Part No. Description Product Life Cycle Phase *) unit, 24 VDC, spring terminals. unit, 24 VDC, spring terminals, XC version

AO523 Analog Input Module

Feeder protection relay SPAA 121 C. Product Guide

SIPROTEC easy 7SJ45 Numerical Overcurrent Protection Relay Powered by CTs

TU531, TU532 Terminal Unit

RTU500 series Data Sheet Power Supply CP-E 24/2.5

CM597 Ethernet Communication Module

AI531 Analog Input Module

IPD163C. Single-Phase Multifunction Meter User Manual Version: V1. August 20, 2017

EM132 EM132. Main Features. Multi-functional 3-Phase Transducer. Energy Meter

DI561 Digital Input Module

Type MVTT 14 and MVTT 15: Static Digital Time delay relays

AX522 Analog Input/Output Module

CEM M-RS485 INSTRUCTION MANUAL (M014B A)

AX521 Analog Input/Output Module

CI504 PROFINET Communication Interface Module

DC562, digital input/output module,

MC 11 EB-2 Power supply cabinet with external bus, AC version

Synchro-check relay. Application

DC561, digital input/output module,

RE48ATM12MW on-delay timing relay s..300 h V AC - 2 OC

DC541 Digital Input/Output Module

OTB1E0DM9LP I/O distributed module OTB - Ethernet TCP/IP m

Content. Time delay relays mounting position. Multifunctional time delay relay Clock-pulse generator time delay relay... 3.

RE22R1QMQ star-delta timing relay - 230VAC/440VAC - 1 C/ O

Technical Requirements for High-voltage DC Power Feeding Interfaces of ICT equipment

Binary output and supervision 520CSD01 Data sheet

CEM M-ETH INSTRUCTION MANUAL (M060B A)

Sensitive definite time or inverse time earth-fault stage for back-up residual earthfault

Arc protection relay. Features Three-phase overcurrent function. Application

P3-SCM. General Specifications

TM221M16R controller M IO relay

CM589 PROFINET Communication Module

PROTECTION RELAYS THE ULTRA LINE NUMERICAL MULTIFUNCTION INTELLIGENT DEVICE FOR PROTECTION, SUPERVISION, METERING AND CONTROL

CM589 PROFINET Communication Module

02/11/2015

CM579-PNIO PROFINET Communication Module

DC522 Digital Input/Output Module

PRO-1250D CT MID DIN rail three phase four wire energy meter.

Output Voltage* (nom.)(adjustable)

NJ-Series Power Supply Unit NJ-PA/PD

CM592 PROFIBUS Communication Module

TM3SAF. Main. Device short name

Combined Overcurrent and Earth-fault Relay SPAJ 140 C. Product Guide

Multifunctional time delay relay MFT U31S, MFT U41SE

RE7RB13MW adjustable off-delay timing relay s V AC DC - 2OC

DX561 Digital Input/Output Module

Power supply CP-C 24/5.0

Voltage Transducer UMT516 / MT516

OTB1S0DM9LP I/O distributed module OTB - Modbus non isolated serial link m

Protection and control. Sepam range Sepam 100 RT. Merlin Gerin Square D Telemecanique

PMC 530 Series Advanced Multifunction Meter

OTB1E0DM9LP I/O distributed module OTB - Ethernet TCP/IP m

Output Voltage* (nom.)(adjustable)

LXEM145 SERIES Lanx Australis single Phase KWh Meter 45Amp. User manual

Contact protection relay

Directional or Non-Directional Earth-Fault Relay REJ 527. Product Guide

ATV310HU30N4E variable speed drive ATV310-3 kw - 4 hp V - 3 phase

Tap Position Indicator - PI

TM221CE40T controller M IO transistor PNP Ethernet

CI542 PROFIBUS Communication Interface Module

Control Panel CP600-eCo CP604, CP604-B

TM221CE24R controller M IO relay Ethernet

Power supplies.

SDM120 SERIES. SDM120 series User Manual. Single phase two wire DIN rail energy meter (One module)

Combined Overcurrent and Earth-fault Relay SPAJ 141 C. Product Guide

OTB1E0DM9LP I/O distributed module OTB - Ethernet TCP/IP m

CD522 Encoder, Counter and PWM Module

LOGIC CONTROLLER INSTALLATION MANUAL NTR 756 B /E

Multifunction Transducer MT440

Technical specifications

COGNEX. Checker SensorView. Quick Reference Guide

RE7YA12BU time delay relay for star-delta starter s - 24 V AC DC - 2OC

TM3TI4 module TM3-4 inputs temperature

General Specifications. P2-SCM Serial Communications

RE17LAMW on-delay timing relay - 1 s..100 h V AC/DC - solid state output

TM221ME32TK controller M IO transistor PNP Ethernet

Operating Manual. English. Digital-Analog Converter DACON8-UMB.

Power supply CP-E 48/1.25 Primary switch mode power supply

Control Panel CP600 CP651, CP651-WEB

EOS-6000 Series Optical A/B Switch User Manual DC Version

This annex is valid from: to Replaces annex dated: Location(s) where activities are performed under accreditation

Transcription:

MO-067-EN Operation Manual MULTIFUNCTIONAL PROTECTION UNIT CONFIGURATION AND GENERAL CHARACTERISTICS LIB Transformer Substations Secondary Distribution Switchgear Primary Distribution Switchgear Protection and Automation Protection Low and Voltage Automation Boards Distribution Transformers

CAUTION! When MV equipment is operating, certain components are live, other parts may be in movement and some may reach high temperatures. Therefore, the use of this equipment poses electrical, mechanical and thermal risks. In order to ensure an acceptable level of protection for people and property, and in compliance with applicable environmental recommendations, Ormazabal designs and manufactures its products according to the principle of integrated safety, based on the following criteria: Elimination of hazards wherever possible. Where elimination of hazards is neither technically nor economically feasible, appropriate protection functions are incorporated in the equipment. Communication about remaining risks to facilitate the design of operating procedures which prevent such risks, training for the personnel in charge of the equipment, and the use of suitable personal protective equipment. Use of recyclable materials and establishment of procedures for the disposal of equipment and components so that once the end of their service lives is reached, they are duly processed in accordance, as far as possible, with the environmental restrictions established by the competent authorities. Consequently, the equipment to which the present manual refers complies with the requirements of section 11.2 of the forthcoming IEC standard 62271-1. It must therefore only be operated by appropriately qualified and supervised personnel, in accordance with the requirements of standard EN 50110-1 on the safety of electrical installations and standard EN 50110-2 on activities in or near electrical installations. Personnel must be fully familiar with the instructions and warnings contained in this manual and in other recommendations of a more general nature which are applicable to the situation according to current legislation.. The above must be carefully observed, as the correct and safe operation of this equipment depends not only on its design but also on general circumstances which are in general beyond the control and responsibility of the manufacturer. More specifically: The equipment must be handled and transported appropriately from the factory to the place of installation. All intermediate storage should occur in conditions which do not alter or damage the characteristics of the equipment or its essential components. Service conditions must be compatible with the equipment rating. The equipment must be operated strictly in accordance with the instructions given in the manual, and the applicable operating and safety principles must be clearly understood. Maintenance should be performed properly, taking into account the actual service and environmental conditions in the place of installation. The manufacturer declines all liability for any significant indirect damages resulting from violation of the guarantee, under any jurisdiction, including loss of income, stoppages and costs resulting from repair or replacement of parts. Guarantee The manufacturer guarantees this product against any defect in materials and operation during the contractual period. In the event that defects are detected, the manufacturer may opt either to repair or replace the equipment. Improper handling of this equipment and its repair by the user shall constitute a violation of the guarantee. Registered Trademarks and Copyrights All registered trademarks cited in this document are the property of their respective owners. The intellectual property of this manual belongs to the manufacturer. In view of the constant evolution in standards and design, the characteristics of the elements contained in this manual are subject to change without prior notification. The validity of these characteristics, as well as the availability of components, are subject to confirmation by Ormazabal s Technical - Commercial Department.

MO-067-EN OPERATION MANUAL CONTENTS 1. GENERAL DESCRIPTION... 4 1.1. USER INTERFACE... 4 1.1.1. Local... 4 1.1.2. Remote... 5 1.2. HARDWARE CONFIGURATION... 5 1.3. ENVIRONMENTAL CONDITIONS... 7 1.4. TESTS... 7 1.4.1. Electrical Tests... 7 1.4.2. Climatic Tests... 7 1.4.3. Mechanical Tests... 7 2. HARDWARE... 8 2.1. CONSTRUCTIONAL CHARACTERISTICS... 8 2.2. REAR TERMINALS... 9 2.3. REAR COMMUNICATION OUTPUT OPTIONS... 10 2.3.1. Single output... 10 2.3.2. Double output... 10 3. TECHNICAL CHARACTERISTICS... 12 3.1. AUXILIARY POWER SUPPLY VOLTAGE... 12 3.2. OUTPUT CONTACTS... 12 3.3. ANALOGUE OUTPUTS... 13 3.4. PHASE AND NEUTRAL CURRENT CIRCUITS (STANDARD RATING 1 A)... 13 3.5. SENSITIVE NEUTRAL OR ISOLATED NEUTRAL CURRENT CIRCUITS (STANDARD RATING 0.025 A)... 13 3.6. PHASE AND NEUTRAL CURRENT CIRCUITS (SPECIFIED RATING 1/5 A)... 13 3.7. SENSITIVE NEUTRAL OR ISOLATED NEUTRAL CURRENT CIRCUITS (SPECIFIED RATING 0.25 / 0.025 A)... 13 3.8. VOLTAGE CIRCUITS... 14 3.9. ACCURACY OF MEASUREMENTS... 14 3.10. OPERATING FREQUENCY... 14 3.11. PHASE ORDER... 14 Page Page 3 3 of of 1516 15

OPERATION MANUAL MO-067-EN 1. GENERAL DESCRIPTION units are multifunctional protection relays of numeric technology, and constitute the basic element of protection measurement and control for cogeneration installations or MV electric bays. They can be used as autonomous protection, control and measurement elements of electric bays, or incorporated into an integrated protection and control system. Different models are available, each having a distinct aspect of hardware or functionality. A common aspect to all the models is the firmware; the functions available to the user of each model are defined in the circuit of a programmable logic device (PLD), which cannot be configured by the user. 1.1. USER INTERFACE 1.1.1. Local The front board has: 4 2 1 3 5 Figure 1.1: Front mimic diagram 1 2 16-key keyboard 4 signalled push-buttons : Circuit-breaker closing : Circuit-breaker opening : Local / Remote : Validates three other push-buttons in order to prevent unintended operations. It must be pressed at the same time as the other buttons to take effect. NOTE:. In order to consider these push-buttons active, they must be pressed for at least half a second. In order for them to take effect, the "Enable push-buttons" configuration must be set to "Yes". 3 4 5 2-row, 16-character display 7 red LED lights and one green/red RS-232 connector for direct connection to a PC via Procome Protocol. Page 4 of 15 Page 4 of 16

MO-067-EN OPERATION MANUAL 1.1.2. Remote Depending on the model, there is a rear board consisting of 1 or 2-way glass optical fibre (ST type connector), plastic optical fibre, RS-232 o RS-485 for a PC, modem or substation control unit connection (in integrated systems). Protocol available is: Procome, DNP 3.0, MODBUS, IEC 870-5-101 or IEC 870-5-103. Models with an Ethernet port (optical fibre or RJ-45) are available with TCP/IP Procome protocol. 1.2. HARDWARE CONFIGURATION The different hardware possibilities that define a model are: Hardware Configuration Box type Horizontal Terminal type Unit power supply voltage Pin-type termination Eyelet termination 125 / 220 V DC 24 / 48 V DC Voltage range of digital inputs Extended (low) 18 to 160 V ( DC * ) Extended (high) 86 to 280 V ( DC * ) Restricted 24 V DC 18 to 34 V ( DC ** ) Restricted 48 V DC 36 to 60 V ( DC ** ) Restricted 125 V DC 85 to 150 V ( DC ** ) Restricted 220 V DC 165 to 264 V ( DC ** ) ( * ) Single-directional inputs (with polarity) ( * ) Two-way inputs (without polarity) Page Page 5 5 of of 1516 15

OPERATION MANUAL MO-067-EN Number of digital inputs/outputs Analogue inputs [3] Standard Extended: adds to the standard Extended (option 2): adds to the standard Rear communication [2] Hardware Configuration 8 inputs (5 independent, 3 with a common point) 7 outputs (4 independent, 3 with a common point) 9 inputs (6 independent, 3 with a common point) 7 outputs (4 independent, 3 with a common point) 5 independent inputs 6 outputs (4 independent, 2 with a common point) 2 analogue outputs (0 to 5 ma) [1] Glass optical fibre (GOF) Plastic optical fibre (POF) RS-232 RS-485 GOF + GOF POF + POF RS-232 + RS-232 RS-485 + RS-232 GOF + RS-232 GOF + Ethernet (RJ-45) GOF + Ethernet (OF) RS-232 + Ethernet (RJ-45) RS-485 + Ethernet (RJ-45) Input number Application 1 I A phase current metering 2 I B phase current metering 3 I C phase current metering 4 I N sensitive neutral current metering Not available 5 [4] I N sensitive neutral current metering V 0 zero-sequence voltage metering 6 V A phase voltage metering 7 V B phase voltage metering 8 V C phase voltage metering Not available 9 [4] V 0 zero-sequence voltage metering V 0 zero-sequence voltage metering for the syncrocheck function [1] For other ranges, please consult the Ormazabal Technical - Commercial Department. [2] In the event of rear two-way ports, the one indicated in second place is in parallel with the front RS-232 (they occupy the same port). [3] The unit can have up to 9 analogue inputs (via a transformer). [4] Depending on the model, the input possibilities vary. Page 6 of 15 Page 6 of 16

MO-067-EN OPERATION MANUAL 1.3. ENVIRONMENTAL CONDITIONS Operation temperature - 10 to + 55 ºC Storage temperature - 40 to + 85 ºC Relative humidity up to 95% with no condensation 1.4. TESTS 1.4.1. Electrical Tests Dielectric rigidity acc. to IEC 255-5, C series (2 kv, 1 min) Insulation resistance acc. to IEC 255-5, > 10 GΩ at 500 V dc Pulse (lightning impulse) acc. to IEC 255-5, appendix E., class III HF disturbances acc. to IEC 255-22-1, class III Fast transients (bursts) acc. to IEC 61000-4-4, class IV Electrostatic discharges acc. to IEC 61000-4-2, class IV Overvoltage pulses (surge) acc. to IEC 61000-4-5, class IV Voltage dips acc. to IEC 60870-2-1, 100 ms at 110 V dc Radiated electromagnetic interference acc. to EN 61000-6-4 Immunity to radiated fields acc. to IEC 61000-4-3, class III Immunity to induced signals acc. to IEC 61000-4-6, class III radiofrequency Immunity to magnetic fields acc. to low frequency IEC 61000-4-8 1.4.2. Climatic Tests Cold acc. to IEC 68-2-1 (-40ºC) Dry heat acc. to IEC 68-2-2 (+85ºC) Humid heat acc. to IEC 68-2-3 (+70ºC, 93% Relative humidity) Thermal shock acc. to IEC 68-2-14 (-20º/70ºC. 2 4-hour cycles) Operating range - 10ºC to + 55ºC 1.4.3. Mechanical Tests Vibration tests acc. to IEC 255 21-1 class I Shock and bump tests acc. to IEC 255-21-1 class I Page Page 7 7 of of 1516 15

OPERATION MANUAL MO-067-EN 2. HARDWARE 2.1. CONSTRUCTIONAL CHARACTERISTICS Horizontal box (-H). Figure 2.1: External dimensions of the unit [mm] Figure 2.2: Panel cut-off [mm] Page 8 of 15 Page 8 of 16

MO-067-EN OPERATION MANUAL 2.2. REAR TERMINALS Figure 2.3: Standard (all for pin-type termination) Figure 2.4: Eyelet-type termination terminal option for analogue inputs Page Page 9 9 of of 1516 15

OPERATION MANUAL MO-067-EN 2.3. REAR COMMUNICATION OUTPUT OPTIONS 2.3.1. Single output Figure 2.5: OF (glass or plastic) Figure 2.6: RS-485 Figure 2.7: RS-232 2.3.2. Double output Figure 2.8: OF + OF Figure 2.9: RS-485 + RS-232 Figure 2.10: RS-232 + RS232 Page 10 of 15 Page 10 of 16

MO-067-EN OPERATION MANUAL Figure 2.11: OF + RS-232 Figure 2.12: Ethernet OF + OF Figure 2.13: Ethernet RJ45 + OF Figure 2.14: Ethernet RJ45 + RS-232 Figure 2.15: Ethernet RJ45 + RS-485 Page Page 11 11 of of 151615

OPERATION MANUAL MO-067-EN 3. TECHNICAL CHARACTERISTICS 3.1. AUXILIARY POWER SUPPLY VOLTAGE 24 and 48 V dc models Operating range: 18 to 60 V dc 125 and 220 V dc models Operating range: 86 to 280 V dc Consumption: 8 W minimum 18 W maximum 3.2. OUTPUT CONTACTS Relays 1 to 6 and 8 to Passage of current (permanent) + 5 A to + 25 ºC 13 Max. inrush current (0.5 s) 30 A Breaking capacity 220 V dc 0.4 A 125 V dc 1 A 48 V dc 3 A Breaking capacity 220 V dc 0.2 A (L/R=40 ms) 125 V dc 0.3 A 48 V dc 0.5 A Relays 7 and 14 Passage of current (permanent) + 5 A to + 25 ºC Max. inrush current (0.5 s) 30 A Breaking capacity 220 V dc 0.15 A 125 V dc 0.4 A 48 V dc 2 A Breaking capacity 125 V dc 0.25 A (L/R=40 ms) 48 V dc 0.5 A Page 12 of 15 Page 12 of 16

MO-067-EN OPERATION MANUAL 3.3. ANALOGUE OUTPUTS Range: 0 to 5 ma Accuracy: ±1% of full scale Maximum load: 1200 Ω Insulation: 1 kv 3.4. PHASE AND NEUTRAL CURRENT CIRCUITS (standard rating 1 A) Phases full scale 40 A Neutral full scale 20 A Thermal Capacity Continuous 20 A Short duration 500 A (1 s) Consumption I r = 1 A < 0.02 VA 3.5. SENSITIVE NEUTRAL OR ISOLATED NEUTRAL CURRENT CIRCUITS (standard rating 0.025 A) Full scale 1 A Thermal Capacity Continuous 3 A Short duration 60 A (1 s) Consumption I r = 0.025 A < 0.015 VA 3.6. PHASE AND NEUTRAL CURRENT CIRCUITS (specified rating 1/5 A) Thermal Capacity Continuous 20 A Short duration 500 A (1 s) Very short duration 1250 A (half cycle) Consumption I r = 5 A < 0.2 VA Consumption I r = 1 A 0.02 VA 3.7. SENSITIVE NEUTRAL OR ISOLATED NEUTRAL CURRENT CIRCUITS (specified rating 0.25 / 0.025 A) Thermal Capacity Continuous 20 A Short duration 500 A (1 s) Consumption I r = 0.025 A 0.015 VA Page Page 13 13 of of 151615

OPERATION MANUAL MO-067-EN 3.8. VOLTAGE CIRCUITS Thermal Capacity Continuous 2 U r Short duration 5 U r (1 s) 3.5 U r (1 min) Consumption 63.5 V 0.015 VA Consumption 100 V < 0.03 VA NOTE: units preferably have standard rating current circuits. Specified rating current circuits can be provided optionally after confirmation from the Ormazabal Technical - Commercial Department. 3.9. ACCURACY OF MEASUREMENTS Current Range (0 to 1.2*I r ) For I r =1: class 1 (1% of I r ) For I r =5: class 0.5 (0.5% of I r ) Protection range (0.1 to 200 A) 1% of the real value, for I> 1 A 3% of the real value, for I> 1 A (in areas where the measurement range and the protection range overlap, the accuracy is the best one of both of them) Voltage Accuracy 0.5% of rated voltage U r to 1.2*V r Phase difference angles Accuracy ±1º Active power Range (0 to 1.2*I r *1.2*V r ) For I r = 1: class 1 (1% of P r ) For I r = 5: class 0.5 (0.5% of P r ) 3.10. OPERATING FREQUENCY Rated: 50 or 60 Hz (programmable) Operating range: f r ± 5 Hz 3.11. PHASE ORDER ABC or CBA (programmable) Page 14 of 15 Page 14 of 16

MO-067-EN OPERATION MANUAL NOTES Page Page 15 15 of of 151615

OPERATION MANUAL MO-067-EN TECHNICAL - COMMERCIAL DEPARTMENT: www.ormazabal.com Page 16 of 15 Page 16 of 16