Wall mounted units. Please read carefully and thoroughly this manual before operating this unit and save it in a safe place for future reference.

Similar documents
REMOTE CONTROLLER CS244-R OWNER S MANUAL

Chilled Water REMOTE CONTROLLER OPERATION MANUAL MAN-O-CRC4AH intensity.mx

REMOTE CONTROL USER MANUAL QUICK CONNECT MINI-SPLIT

Portable Room Air Conditioner Remote Control for:

Owner s Manual RBC-AX32U(W)-E RBC-AX32U(WS)-E AIR CONDITIONER (SPLIT TYPE) Wireless remote controller kit. Model name: English.

Part 6 Control System

OPERATION INSTRUCTIONS

NOTE CONTENTS NOTE-CONTENTS

REMOTE CONTROLLER OWNER'S MANUAL AIR CONDITIONER OWNER'S MANUAL ATI/AOU-53HPR1 ATI/AOU-105HPS3 ATI/AOU-140HPS3

Wireless Remote Controller Kit

REMOTE CONTROLLER RG57 Function Selection Manual

Owner's Manual. Carrier TOSH BA REMOTE CONTROLLER FOR AIR CONDITIONER (SPLIT TYPE) Wireless remote controller kit TCB-AX21 UL

Wired Controller Operation & Installation Manual

Ασύρματο Τηλεχειριστήριο YB1FA

V0STAT51P-2 Programmable Wired Controller

Operation 6035 ENGLISH PROG MENU

Communicating Wall Control Owner s Manual TSTAT0101SC

Model Instruction Manual. Heat Stress Meter. reedinstruments. www. com

OWNER S MANUAL WIRE CONTROLLER OF AIR CONDITIONER. MODEL: KJR-12B/DPBG(T)-E Brivis Part No:B026000

PLXRMM1605. Wall Mounted. FT-A Series. COOLING ONLY [50Hz] V

REMOTE CONTROL OPERATING INSTRUCTIONS

WIRED REMOTE CONTROLLER OPERATION MANUAL

76 F. Ductless Split Air Conditioner. YR-E16b Wired Controller User Manual WARNING

Digital Room Thermostat

Model: Available in : Sapphire Black and Glacier White

S-Series Digital Thermostat

Daikin HVAC Controls Guide Specification

Central Controller Operation & Installation Manual

SHUTTERBOSS VERSION II USER MANUAL

Installation Manual RB-RWS20-E. Lite-Vision plus Remote Controller. Model name: English

Model: Available in : Sapphire Black and Glacier White

S-Series Digital Thermostat

M U L TI - SP ORT SCOREBOARD

ADVANCED REMOTE CONTROL

REMOTE CONTROL INSTALLATION & OPERATING INSTRUCTIONS

QUICK REFERENCE. Remote controller BRC1E51

UC102 basic version with display and knob UC102BL version with display, knob and backlight UC102DK version without knob and display

Instruction Book. English. CITY MULTI Control System and Mitsubishi Mr. Slim Air Conditioners MA Remote Controller PAR-31MAA

USER MANUAL SMART AC. CW058IU-AWIFI midea.com. version B C (PREVIEW01)

SHUTTER WORLD. PerfectTilt RF Motorized Shutter. User Manual

Please scan the QR code to download the latest App software.

Model FP700 Owner s Instructions

Operation Guide CT32 ENGLISH

Handheld Odor Meter OMX-ADM. Operation Manual. Ver

RBC-AMS55E-ES RBC-AMS55E-EN

Installation, Start-up and Operating Instructions

Pocket Quick Reference Guide On the TOSHIBA

CONTENTS DECLARATION OF CONFORMITY

smartentry Wireless Video Doorphone User Manual

Daikin HVAC Controls Guide Specification

INTERFACE SPECIFICATION

Digital Timer Outlet Model No.: EDT-1USA. Questions or Concerns? (855)

Wireless 7 Day Programmable Room Thermostat

OPERATION MANUAL. Room thermostat EKRTW

Deluxe In/Out Remote Thermometer with Trend Chart

CONTENTS. Smart phone Environment and Wi-Fi Module...1 Downloading and Installing the App...2 Activate and Welcome screen...4

Installation Instructions

HOBO Light On/Off Data Logger (UX90-002x) Manual

CONTENTS. Introduction to WI-FI fuctions. Download and install the control software. Reset AC WI-FI module

Dryer. M720 Programming and Operation Manual. July 15, 2015 Revision 1.51

IntesisBox SMS - Mitsubishi Electric air conditioners

Operation Guide CT101

AirTouch 2 Zone Control System

IS-ZW-RC-1 Remote Control Installation Sheet

Single phase. Technical Support Division

IO-INTERFACE. Procon. INSTALLATION MANUAL Version 1.01 MITSUBISHI ELECTRIC FOR INSTALLERS

RF-Link 2.4GHz Digital Wireless Color Security/Baby Monitor. Model: ABM-4161 User's Manual

Forward. Product Introduction. Specifications

ARTiPRO. User Manual. (Model 910 & 920)

Super Digital Inverter / RAV Series 2010 Technical training

CA001U-APP(G3) A

Model: Touchpad (TFT) Model: TFT

3. Alignment and Adjustments

Operation Guide CT100

Wifi Smart. Thank you for choosing our product. For proper operation, please read and keep this manual carefully.

DT810 STOPWATCH WITH PRINTER INSTRUCTION MANUAL. BK233 Printed in China 第一頁

COMFORT CONTROL CENTER SERVICE INSTRUCTIONS

Instruction Book. English. CITY MULTI Control System and Mitsubishi Mr. Slim Air Conditioners MA Remote Controller PAR-30MAA

AirPatrol WiFi Version 2 Full Manual V4.2

Wireless LAN control

Alphanumeric Pager User Manual

DT800 Lane Timer Manual

MultiTherm Shaker. Operations Manual Item: H5000-H and H5000-HC

technical data Systems Individual control systems

Taurus Super-S LCM. Dual-Bay RAID Storage Enclosure for two 3.5 Serial ATA Hard Drives. User Manual July 27, v1.2

1GB/2GB/4GB MP3 Player. Instruction Manual L1GMP309 L2GMP309 L4GBMP310

High Performance Infrared Thermometer with High D:S Ratio, Adjustable Emissivity, and Built-in Laser Sighting

HOBO Occupancy/Light Data Logger (UX90-005x/-006x) Manual

Central Controller G-50A/GB-50 Web Browser Operation Manual (For Managers)

ST9100A User Guide. Features

Quick Start. MyAir4 User Manual. This section will give you a brief description about each of the buttons found on the home screen.

TTL Wireless Flash Trigger FOR CANON. Instruction Manual. Made In China

Instruction Manual. Electronic Horizontal & Vertical Self-Leveling Rotary Laser Level Model Nos , ,

USER'S MANUAL. WiFi MODULE WIFI SMART APP SWM-02

PORTABLE VETERINARY X-RAY EQUIPMENT INSTRUCTION MANUAL

Wired Cycle Computer Instruction Manual

USER'S MANUAL ZOOM SERIES WIFI SMART APP

Obtaining Documentation and Submitting a Service Request, page xvii Safety Warnings, page xvii Safety Guidelines, page xx

Ultra-Slim Bluetooth keyboard with Touchpad (ZW-51012BT) User Manual

INSTRUCTION MANUAL VOLTAGE REGULATOR MAXBEC2D PLUS EX

Transcription:

OWNERS' MANUAL REMOTE CONTROLLER Wall mounted units Please read carefully and thoroughly this manual before operating this unit and save it in a safe place for future reference.

Warning. Be sure there are no barriers between the remote controller and the receiver of indoor unit otherwise the air conditioner will not work.. Keep the Remote Controller away from all liquids.. Protect the Remote Controller from high temperatures and exposure to radiation.. Keep the indoor receiver out of direct sunlight or the Air Conditioner may malfunction.. Keep controller away from EMI (Electro-Magnetic Interference) supplied by other household appliances. CONTENTS Remote Controller Specifications--------------------------------------- Performance Features----------------------------------------------------- Introduction of Function Buttons on the Remote Controller--- Names and Functions of indicators on Remote Controller---- Operating the Remote Controller--------------------------------------- Warning--------------------------------------------------------------------------

Remote Controller Specifications Model Rated Voltage Lowest Voltage of CPU Emitting Signal Reaching Distance Environment Temperature Range Performance Features.0V.0V RA/E 8m (when using.0 voltage, it Gets m) - C 0 C ~. Operating Mode: COOL HEAT DRY FAN only and AUTO.. Timer Setting Function in hours.. Indoor Setting Temperature Range : C~0 C.. LCD (Liquid Crystal Display) of functions. Introduction of Function Buttons on the Remote Controller SET TEMP On/Off Mode. To set the STOPPING time.. Push the Timer off button and the remote controller will show OFF TIMER, the last set time for the stopping operation and the signal "Hr" will be shown on the Timer display area. You are now ready to reset the time of the STOP operation.. Push the Timer off button again to set the time you want to stop the operation.. After setting the Timer off,there will be a one-half second delay before the remote controller transmits the signal to the air conditioner.. Set the starting & stopping time. Push the Timer on button, the remote controller will show ON TIMER, the last set time for START operation and the signal "Hr" will be shown on the Timer display area. You are now ready to readjust the Timer on to start the operation.. Push the Timer on button again to set the time you want to start the operation.. Push the Timer off button, the remote controller will show OFF TIMER, the last set time for STOP operation and the signal "Hr" will be shown on the Timer display area. You are now ready to reset the time to STOP operation.. Push the Timer off button again to set the time you want to stop the operation.. After setting the TIMER, there will be a one-half second delay before the remote controller transmits the signal to the Air Conditioner. ON TIMER Off TIMER Fan Sleep/ Swing Air Direction Timer On Timer Off If the same time is set for both START and STOPPING settings, the stopping time will automatically increase 0.hr(the set time displays less than 0Hr) or one hour (the set time displays 0Hr or more). To change the Timer on/off time, just press the corresponding TIMER button and reset the time. The setting time is relative time. That is the time set is based on the delay of the current time. Fig.

COOL, HEAT, and FAN ONLY Operation. If the AUTO mode is not comfortable, you may manually override the settings by using COOL, DRY, HEAT( HEAT PUMP units only), or FAN ONLY modes.. Push the or button to set the desired room temperature. When in COOLING mode, the most comfortable settings are C or above. When in HEATING mode, the most comfortable settings are 8 C or below.. Push the Fan button to select the FAN mode of AUTO, HIGH, MED or LOW.. Push the On/off button. The operation lamp lights and the air conditioner starts to operate per your settings. Push the On/off button again to stop this unit operation. The FAN ONLY mode cannot be used to control the temperature. While in this mode, only steps and may be performed. DRY OPERATION. Push the Mode button to select DRY.. Push the or button to set the desired temperature from C to 8 C.. Push the On/off button. The operation lamp lights and the air conditioner starts to operate in the DRY mode. Push the On/off button again to stop this unit operation. Due to the difference of the set temperature of the unit and the actual indoor temperature, the Air Conditioner when in DRY mode will automatically operate many times without running the COOL and FAN mode. TIMER OPERATION Push Timer on/off button to set the on and off times of the unit. The effective operation time set by the remote controller for the timer function is limited to a period of between 0. and less than hours.. To set the STARTING time.. Push the Timer on button, then the remote controller shows ON TIMER, the last set time for the starting operation and the signal "Hr" will be shown on the Timer display area. You are now ready to reset the time to START the operation.. Push the Timer on button again to set desired unit start time.. After setting the Timer on,there will be a one-half second delay before the remote controller transmits the signal to the air conditioner. On/off Button: Push this button to start the unit operation. Push the button again to stop the unit operation. Mode Button: Each time you press the button, a mode is selected in a sequence that goes from AUTO COOL DRY HEAT and FAN only as the following figure indicates: AUTO COOL DRY HEAT FAN : HEAT only for Heat Pump Button : Push the button to increase the indoor temperature setting to 0. Button : Push the button to decrease the indoor temperature setting to. Fan Button: This button is used for selecting Fan Speed. Each time you press the button, a fan speed is selected in a sequence that goes from AUTO LOW MED to HIGH, then back to. When you select the AUTO or DRY mode, the fan speed will be automatically controlled and you can not set the fan speed. Sleep/ Button: Press this button to select SLEEP or TURBO mode. Each time you press the button, the operation mode is shifted in the direction of the arrow. When the operation mode is either DRY or FAN only, this function can not be used. SLEEP SLEEP OFF TURBO TURBO OFF Swing Button: Press the SWING button to activate the swing feature. Push the button again to stop. 8 Air direction Button: Press this button to change the swing o angle of the louver. The swing angle of the louver is C for each press. When the louver swing at a certain angle which would affect the cooling and heating effect of the air conditioner, it would automatically change the swing direction. No symbol will appear in the display area when press this button. 9 Timer on Button: Press this button to initiate the auto-on time sequence. Each press will increase the auto-timed setting in 0 minutes increments. When the setting time displays 0Hr, each press will increase the auto-timed setting 0 minutes increments. To cancel the auto-timed program, continue pressing the button until nothing displays. 0 Timer off Button: Press this button to initiate the auto-off time sequence. Each press will increase the auto-timed setting in 0 minutes increments. When the setting time displays 0Hr, each press will increase the auto-timed setting 0 minutes increments. To cancel the auto-timed program, continue pressing the button until nothing displays.

Names and Functions of indicators on Remote Controller Display Panel SET ON Off TEMP TIMER TIMER Fig. TRANSMISSION Indicator: This indicator lights when remote controller transmits signals to indoor unit. MODE indicator: Displays the current operation modes. Including AUTO( ), COOL( ), DRY( ), HEAT( ) or FAN( ). HEAT only available for heat pump model. TEMPERATURE indicator: Displays the temperature settings( to 0 ). FAN SPEED indicator: Displays the selected fan speed, AUTO( ) and three fan speed levels LOW( ), MED( ), HIGH( ). Displays (flashing) when the operating mode is either AUTO or DRY. SLEEP/TURBO indicator: Each time the Sleep/ button is pushed, the signal displays in the following sequence: Nothing SWING indicator: This indicator lights up when the SWING button is pressed. TIMER indicator: The time set for timer operation is indicated. (0. ~ hours) : All items are shown in the Fig. for the purpose of clear presentation But during the actual operation only the relative functional items are shown on the display panel. Nothing Nothing appears when the operating mode is either DRY or FAN only Operating the Remote Controller Install / Replace Batteries Use two alkaline dry batteries (R0/LR0X). Do not use rechargeable batteries. () Remove the battery cover by pulling it according to the arrow direction. () Insert new batteries making sure that the (+) and (-) of battery are installed correctly. () Reattach the cover by sliding it back into position.. When replacing batteries, do not use old batteries or a different type battery. This may cause the remote controller to malfunction.. If you do not use the remote controller for several weeks remove the batteries. Otherwise battery leakage may damage the remote controller.. The average battery life under normal use is about months.. Replace the batteries when there is no answering beep from the indoor unit or if the Transmission Indicator light fails to appear. AUTOMATIC OPERATION When the Air Conditioner is ready for use, switch on the power and the OPERATION indicator lamp on the display panel of the indoor unit starts flashing.. Use the Mode select button to select AUTO.. Push the or button to set the desired room temperature. The most comfortable temperature settings are between C to 8 C.. Push the On/off button to start the air conditioner. The OPE- RATION lamp on the display panel of the indoor unit lights. The operating mode is AUTO. The FAN SPEED is automatically controlled.. Push the On/off button again to stop the unit operation.. In the AUTO mode, the air conditioner can logically choose the mode of COOL, FAN, HEAT and DRY by sensing the difference between the actual ambient room temperature and the set temperature on the remote controller.. If the AUTO mode is not comfortable for you, the desired mode can be selected manually.