Precision Cooling Mission Critical Air Handling Units

Similar documents
STULZ Micro DC. with Chip-to-Atmosphere TM Liquid to Chip Cooling

Chilled Water Computer Room Air Handler (CRAH) Critical Infrastructure for the World s Leading Data Centers

CLIMATE. CUSTOMIZED. CyberHandler2 from 30KW to 520 KW. The indirect evaporative free-cooling Air Handling Unit

Air-Side Economizer Cycles Applied to the Rejection of Data Center Heat

Product Brochure DENCO Close Control Units Row-DENCO. High Density Cooling for Data Centres

Your Solution For Energy and Cost Savings. McQuay Packaged Chiller Plant

IT COOLING EVAPORATIVE COOLING SYSTEM. 2 STAGE INDIRECT ADIABATIC COOLING SYSTEM FOR LARGE DATA CENTERS FROM 80 TO 320 kw

Cooling. Highly efficient cooling products for any IT application. For More Information: (866) DATA CENTER SOLUTIONS

Ecoflair Air Economizers

IT Air Conditioning Units

Mission Critical Facilities & Technology Conference November 3, 2011 Cooling 101. Nick Gangemi Regional Sales Manager Data Aire

Schneider Electric Cooling Portfolio. Jim Tubbesing Heath Wilson APC/Schneider North Texas Rep Tubbesing Solutions

Reducing Data Center Cooling Costs through Airflow Containment

Rack cooling solutions for high density racks management, from 10 to 75 kw

Total Modular Data Centre Solutions

Thermal management. Thermal management

InPac 600 Series Fully configurable severe duty and explosion proof HVAC and building pressurization systems 2 5 ton ::

Regulations Determining Computer Room Cooling Selection

FREECOOLING, EVAPORATIVE AND ADIABATIC COOLING TECHNOLOGIES IN DATA CENTER. Applications in Diverse Climates within Europe, Middle East and Africa

CHILLED WATER. HIGH PRECISION AIR CONDITIONERS, FROM 7 TO 211 kw

IT Cooling Solutions. The Whole Range of. Data Center Cooling Solutions

A Data Center Heat Removal System That Saves... 80% Discover Inertech s Award-winning Data Center Heat Removal System

PEX+ High Efficiency, Low Operating Cost Precision Solution for Data Centers

DATA CENTER AIR HANDLING COOLING SOLUTIONS

Industry leading low energy evaporative fresh air cooling.

Evaporative free air cooling technology Providing evaporative free air cooling solutions.

Trailblazer AGZ-E air-cooled scroll chillers

Air Handling Units. With Intelligence

Liebert Economizer Cooling Solutions Reduce Cooling Costs by up to 50% Without Compromising Reliability

IT COOLING AIR CONDITIONERS FOR HIGH DENSITY RACKS AND BLADE SERVERS. RACK COOLING SOLUTIONS FOR HIGH DENSITY RACK MANAGEMENT, FROM 4 TO 75 kw

Precision Cooling. Precision Cooling Advantages

Welcome Association of Energy Engineers to the Microsoft Technology Center

ZTE ZXCR Series DX In-Row Air Conditioning Product Description

Liebert. PDX from 15 to 165 kw. Direct Expansion Solution for Small and Medium Data Centers

Liquid Cooling Package LCP Cooling Systems

Digital Realty Data Center Solutions Digital Chicago Datacampus Franklin Park, Illinois Owner: Digital Realty Trust Engineer of Record: ESD Architect

PEX (R410A) High Efficiency, Green Solution Precision Cooling for Data Centers

Liebert. AFC from 500 to 1700 kw. The Adiabatic Freecooling Solution with Top-Tier Availability

Reliability and extended operation

Liebert PDX from 15 to 120 kw

Future of Cooling High Density Equipment. Steve Madara Vice President and General Manager Liebert Precision Cooling Business Emerson Network Power

InRow Chilled Water. Up to 70kW. Close-coupled, chilled water cooling for medium to large data centers. Row-Based Cooling.

Liebert PDX from 15 to 120 kw

MSYS 4480 AC Systems Winter 2015

DATA CENTER EFFICIENCY: Data Center Temperature Set-point Impact on Cooling Efficiency

Data Center Energy Savings By the numbers

7 Best Practices for Increasing Efficiency, Availability and Capacity. XXXX XXXXXXXX Liebert North America

Aquaflair. Uniflair TRAC, TRAF and TRAH. Air-cooled chillers, free-cooling chillers and heat pumps with scroll compressors.

STULZ Custom Indoor AHU

Liebert. AFC from 500 to 1450 kw. The Adiabatic Freecooling Solution with Top-Tier Availability CERTIFIED HVAC-HYGIENE.

Ecotel Free Cool 5-15kW

Liebert AFC from 500 to 1450 kw. The Adiabatic Freecooling Solution with Top-Tier Availability

COOLING SOLUTIONS. SmartRack Close-Coupled Cooling for IT Environments

Close-coupled cooling

HIGH EFFICIENCY Central Chiller

Liebert. EFC from 100 to 350 kw. The Highly Efficient Indirect Evaporative Freecooling Unit

REPORT. Energy Efficiency of the San Diego Supercomputer Center and Distributed Data Centers at UCSD. Prepared for:

Retro-Commissioning Report

Liebert. icom Thermal System Controls Greater Data Center Protection, Efficiency & Insight

Efficiency of Data Center cooling

Introducing the Heat Wheel to the Data Center

Data center cooling evolution. The hottest way to save energy. Lucio Bustaffa: Product Development Manager BlueBox Group

Is Data Center Free Cooling Feasible in the Middle East? By Noriel Ong, ASEAN Eng., PMP, ATD, PQP

Passive RDHx as a Cost Effective Alternative to CRAH Air Cooling. Jeremiah Stikeleather Applications Engineer

Liebert AFC from 500 to 1450 kw. The Adiabatic Freecooling Solution with Top-Tier Availability

innovations in ENVIRONMENTAL CONTROL THE SOLUTIONS OF CHOICE FOR ALL THE REASONS THAT MATTER

AireFlow kW DX AIR. Data Centre Cooling Product of the Year. Indirect Adiabatic AHU

CTC Low Temperature Process Chillers

Running Your Data Center Under Ideal Temperature Conditions

Data Center Optimized Controls

Globally Close to You Precision Control

DUCTED SPLIT SYSTEMS With Scroll compressors

HIGH EFFICIENCY 15 and 17 SEER TWO STAGE HEAT PUMP ENVIRONMENTALLY SOUND R 410A REFRIGERANT. Min. Circuit Ampacity

SmoothAir Modular Precision Cooling

Rittal Cooling Solutions A. Tropp

Liebert. DCL up to 35 kw. Modular Rack Cooling

Liebert. DCL up to 35 kw. Modular Rack Cooling

INNOVATE DESIGN APPLY.

INNOVATE DESIGN APPLY.

DCC Commercial. Submittal Data Form Tons Packaged Air Conditioners

Implications of Current Thermal Guidelines

Liquid Cooling Package LCP Cooling Systems

Motivair MLC-SC Air-Cooled Scroll Chillers Tons

Impact of Air Containment Systems

Excool Indirect Adiabatic and Evaporative Data Centre Cooling World s Leading Indirect Adiabatic and Evaporative Data Centre Cooling

glide glider kw R134a air cooled liquid chillers AND free cooling chillers FREE COOLING SHELL A C CLASS E C Energy Class RCGROUP SpA

YORK SOLUTION AIR HANDLING UNITS

IEC DATA CENTRE INDIRECT EVAPORATIVE COOLING SYSTEM

Min. Circuit Ampacity. Max. Fuse or Breaker. Ship / Operating Weight lbs. (kg) C4H524GKD 2 24,

Liebert. HPC-S Free Cooling Chiller Designed for the Efficient Cooling of Small Data Centers

ENCLOSURE HEAT DISSIPATION

M+W Group s Visionary Delta Datacenter

Precision Cooling for Business-Critical Continuity. Liebert HPC-S. Designed for the Efficient Cooling of Small Data Centers

CASE STUDIES ENERGY EFFICIENT DATA CENTRES

Aquaflair. BREC & BREF kW 380V/3ph/60Hz - 460V/3ph/60Hz. Air-cooled chillers and free-cooling chillers with double screw compressors

T66 Central Utility Building (CUB) Control System Reliability, Optimization & Demand Management

Aquaflair. BREC/F and BCEC/F kw

Cabinet Level Containment. IsoFlo Cabinet. Isolated Airfl ow Cabinet for Raised Floor Data Centers

Cooling solutions for imaging systems. Reliable. Global. Customer-specific.

i-accurate_gb_ High precision air-conditioners for data centres cooling, with new inverter technology and R-410A refrigerant, from 6 to 150 kw

Transcription:

M I S S I O N C R I T I CA L C O O L I N G Precision Cooling Mission Critical Air Handling Units

Global Expertise for Precision Cooling Solutions STULZ is a privately owned, global manufacturer of highly efficient temperature and humidity management technology. STULZ engineers a full line of air conditioners, air handling units, ultrasonic humidifiers, desiccant dehumidifiers and custom solutions, specifically for industrial, commercial and secure mission-critical applications. The global STULZ Group includes two major divisions, seven production plants, and hundreds of sales and service partners around the world. Wherever you are, we have a presence and an innovative solution designed to meet your specific needs.

Custom Outdoor AHU STULZ CyberHandler Controls and Monitoring STULZ CyberHandler is specifically designed to free up space in the data center, allowing more room for IT equipment. Utilizing proven precision technology from STULZ, CyberHandler satisfies the exacting requirements of outdoor, rooftop or at grade mounted mission critical applications. Capacity Airflow STULZ CyberHandler (ASM) DX or CW kw (MBH) 120-460 (420-1,560) Tons 35-130 m3/hr 20,400-93,500 CFM 12,000-55,000 STULZ CyberHandler combines decades of experience building rugged outdoor air handling equipment and data center cooling design expertise to create a unit ideally suited for harsh outdoor conditions, while providing mission critical design elements. STULZ state-of-the-art E 2 Microprocessor with a range of BMS interface options EC fan array with variable airflow Direct free cooling options including direct adiabatic Environmentally friendly R410A refrigerant Modular design Variety of installation configurations, including roof and at-grade No maintenance work inside the data center (safety, cleanliness, time-saving and security) Large capacity range Coil bypass design reduces air pressure drop under low load conditions Powder coated aluminum panels with a variety of insulation options Various voltages available in 50/60 Hz designs Dual power supply available with Automatic Transfer Switch Filter options available in MERV7 to MERV14 Ease of access for service and maintenance Meets global standards

Indirect Evaporative AHU STULZ IeCE - Indirect Evaporative STULZ IeCE is a purpose built AHU designed to meet the demands of modern IT loads while maximizing the use of highly efficient free cooling and indirect evaporative technologies. STULZ IeCE can operate in any combination of dry, wet, or mechanical trim cooling modes based on external environmental conditions. STULZ IeCE Indirect Evaporative Cooling Equipment Purpose built solutions ranging up to 60,000 cfm (102,000 m 3 /hr) per unit. Using an air-to-air heat exchanger, STULZ IeCE keeps the conditioned space free from outside contaminants while achieving potential savings of up to 75% over traditional mechanical cooling methods. STULZ state-of-the-art E 2 Microprocessor with a range of BMS interface options EC fan array with variable airflow DX & CW trim cooling or 100% back-up cooling options - Environmentally friendly R410A refrigerant Variety of installation configurations - including roof and at-grade Three modes of operation: Dry Mode, Wet Mode, DX & CW Assist Mode Provides tremendous energy savings vs standard Direct Expansion (DX) or Chilled Water (CW) only Lower OPEX Various voltages available in 50/60 Hz designs Dual power supply available with Automatic Transfer Switch Filter options available in MERV7 to MERV14 Ease of access for service and maintenance Meets global standards 11

STULZ CyberCon Packaged Rooftop STULZ CyberPack Pre-Engineered Controls and Monitoring Modular Cooling STULZ CyberPack provides a self-contained, DX air-cooled rooftop system, designed specifically for continuous operation in mission critical environments. Capacity Airflow STULZ CyberPack kw (MBH) 40-105 (140-360) Tons 12-30 m 3 /hr 9,000-20,400 CFM 5,300-12,000 Capacity data based on 80.0 F (26.7 C) db / 67.0 F (19.4 C) wb For Reference Only Built designs are driven by customer specification. STULZ CyberPack was designed specifically for data centers, with solid construction, proven cooling technology and flexible controls. STULZ state-of-the-art E 2 Microprocessor with a range of BMS interface options 100% Air-Side Economizer option to achieve lower OPEX Robust all aluminum cabinet construction for long term operation Highly efficient scroll compressor technology with multi-circuit and staged configurations Environmentally friendly R410A refrigerant -30 F to 115 F (-34 C to 46 C) ambient operation EC fans offer considerable energy cost savings and maintenance free operation Condenser fan speed control via system controller without the use of VFD s Functional operations: cooling, dehumidification and filtration Various voltages available in 50/60 Hz designs Filter options available in MERV7 to MERV14 Meets global standards

Custom Indoor AHU STULZ Custom AHU Controls and Monitoring The STULZ Custom AHU is a purpose built solution that meets users unique requirements for indoor mounted environments. STULZ works closely with our customers to design the optimal unit for their specific needs, ensuring the right solution, everytime. STULZ Custom AHU Purpose built solution based on user requirements. Custom air handling units are engineered to order solutions that meet today s cutting edge data center design requirements. By using proven STULZ technology, custom AHU s provide the efficiency and performance that users and operators demand. STULZ state-of-the-art E 2 Microprocessor with a range of BMS interface options 3rd party controls integration available Controller UPS available for keep-alive Robust, extruded aluminum construction with various panel thickness, including a thermal break option EC fan array with variable airflow Extensive range of capacities and cooling configurations - Direct Expansion - Chilled Water - Direct Adiabatic - Free Cooling: air-side and water-side economizer solutions Various voltages available in 50/60 Hz designs Dual power supply available with Automatic Transfer Switch Custom horizontal and vertical orientation to fit any space Flexibility to be mounted on pad, steel, curb, or floor stand structures with lifting points for rigging Filter options available in MERV7 to MERV14 Ease of access for service and maintenance Meets global standards

Horizontal AHU The horizontal AHU, available with direct expansion (DX) and chilled water (CW) cooling, is designed specifically to meet customer requirements. A specialized fan wall array ensures uniform airflow while meeting low power consumption requirements. Counterbalanced fan inlet backdraft dampers minimize air recirculation. Modular Split AHU The modular split AHU is available with DX and CW cooling. A vertical center split allows the modular AHU to fit in service elevators and maneuver within tight spaces. Its modular design allows easy reassembly and rewireing on-site using minimal labor (via frame and electrical connectors). The unit can also be deployed and/or operated as a half unit by only utilizing one side, therefore increasing redundancy. Horizontal Stackable Fan/Coil Unit Stackable chilled water fan coil unit reduces total footprint while maintaining unit serviceability. Designed to easily stack units securely. Electrical connectors provided between stacked units to reduce on-site installation time and cost. Horizontal Split Sectional AHU The horizontal split sectional AHU is available with DX and CW cooling. It is sized and split to fit in a standard freight shipping container for intermodal transportation. Unit can be easily reassembled and rewired on site using minimal labor (via frame and electrical connectors). Air discharge sound attenuators provided for low sound applications.

Solutions Portfolio Precision Cooling and Ultrasonic Humidification Indoor Cooling Outdoor Cooling Retrofit and Humidification Perimeter Custom Air Handler Row Ceiling Custom Air Handler Indirect Evaporative Air Handler Packaged Rooftop Modular EC Fan Retrofit Drop-in Replacement Ultrasonic Humidification Direct Expansion (DX) Economizers Chilled Water (CW) Air-Side Economizer Water-Side Economizer Controls and Monitoring Service and Parts For further information, please visit our website at www.stulz-usa.com Designed & Manufactured at STULZ USA Contact STULZ USA Headquarters STULZ AIR TECHNOLOGY SYSTEMS (STULZ USA), INC. 1572 Tilco Drive Frederick, MD 21704 Tel.: 301.620.2033 Fax: 301.662.5487 info@stulz-ats.com www.stulz-usa.com Technical documentation subject to change without notice QC-IAH0101