MANUFACTURER RamSoft Incorporated , Adelaide St E Toronto, ON M5C 3E4 CANADA

Similar documents
RamSoft Client Integration Specification (6.0)

RamSoft Platform Specifications Version 6.0

emix Implementation Steps

Opal-RAD Admin Guide. Table of Contents

Media Server Installation & Administration Guide

Opal-RAD Admin Guide. Viztek, LLC US Highway 70 East Garner, NC Opal-RAD Admin Guide 2.

PACSgear Core Server

CTIMUX for Panasonic TSP

Upgrading the Secure Access Unified ID System to Equitrac Office Equitrac Corporation

NBC-IG Installation Guide. Version 7.2

PACSgear Core Server

OmniArchive Installation & User Manual

Table of Contents. HotSpot Installation. Windows 7, 8.1 and 10. Windows Server OS. DNS Web Filter Setup. Windows Configuration. Antamedia HotSpot?

efolder BDR for Veeam Hyper-V Continuity Cloud Guide Setup Continuity Cloud Import Backup Copy Job Restore Your VM

aasamco Launcher User Guide

Installation Guide. Contents

INSTALLATION GUIDE Spring 2017

Installing ProjectSpec from the ProjectMatrix DVD

Business Connect Secure Remote Access Service (SRAS) Customer Information Package

SecureGuard VMS. SecureGuard All-In-One Quick Install Guide V. 2.5

SET UP VPN FOR WINDOWS 10

Installing Act! for New Users

Select the Akeni Pro Server installation file that matches your operating system and double-click on the file.

Site License Installation Guide

CDR DICOM Quick Start Guide

Assureon Installation Guide Client Certificates. for Version 6.4

Embedded Connector for IKON DocSend Setup Guide

EntraPass WebStation. Reference Manual DN

APC-100. IEEE g Wireless USB Adapter. User s Guide v1.0

Veritas Backup Exec Quick Installation Guide

10ZiG Technology. Thin Desktop Quick Start Guide

CaseMap Server Installation Guide

Table of Contents. Introduction... 3 System Requirements... 3 Tutorial Videos... 3 Installing Racknet... 4 Support... 10

Equitrac Embedded Connector for EFI SendMe. Setup Guide Equitrac Corporation Equitrac Corporation

Lasso CDP. Lasso. Administration Tool Guide. August 2005, Version Lasso CDP Administration Tool Guide Page 1 of All Rights Reserved.

KYOCERA Device Manager Installation and Upgrade Guide

AppSpace Installation Guide. Release 4.1.1

Installing CaseMap Server User Guide

PACS ADMIN. Quick Reference Guide

Installing CaseMap Server User Guide

LiveNX Upgrade Guide from v5.1.2 to v Windows

1 Overview. 2 Installation. exacqvision-entrapass Installation Guide.

BROWSER-BASED SUPPORT CONSOLE USER S GUIDE. 31 January 2017

Kernel for Exchange Server. Installation and Configuration Guide

Installation & Configuration Guide

AnySite. Australia. Install Guide. AnySite v9.1 Install Guide

Intel Small Business Extended Access. Deployment Guide

Upgrading to Act! v20 from ACT! 3.x, 4.x, 5.x (2000), or 6.x (2004)

CKHS VPN Connection Instructions

Installing CaseMap Server User Guide

AWUS036NHR Long-Range Indoor IEEE n USB Adapter User Manual

KYOCERA Device Manager Installation and Upgrade Guide

efolder BDR for Veeam VMware Continuity Cloud Guide

DS2 Support. DS2 / inet System Installation Scenario 2. Scenario 1: - Windows 2003 Server - Utilizing an External SQL Server

Installing the WinSCP Secure FTP Client

December P Xerox FreeFlow Core Installation Guide

MedDream MedDream SendToPACS USER S MANUAL (version 1.16)

DCMSYS Image Generator User Manual

NET SatisFAXtion TM Configuration Guide For use with AT&T s IP Flexible Reach Service And IP Toll Free Service

Quick Start Program Installation Guide

VIN Service: Multiple Connections. Mac

1. Initial Setting and Installation of ActiveVisor... 1

Equitrac Integrated for Konica Minolta

Citrix administator guide

Software Version 6.0 DICOM Conformance Statement

APP NOTES Onsight Rugged Smart Camera Wireless Network Configuration

Guide Citrix administrator guide

Integrated for Océ Setup Guide

Avalanche Remote Control User Guide. Version 4.1

Equitrac Integrated for Océ

DefendX Software Control-QFS for Isilon Installation Guide

Installing and Configuring vcenter Multi-Hypervisor Manager

WA2583 React JavaScript Programming. Classroom Setup Guide. Web Age Solutions Inc.

DefendX Software Control-Audit for Hitachi Installation Guide

MedDream SendToPACS. USER S MANUAL (version )

HySecure Quick Start Guide. HySecure 5.0

NTP Software File Auditor for Windows Edition

Avigilon Control Center Server User Guide

Integrated Information Technology Services (IITS)

dotdefender for IIS Installation Guide

USER GUIDE. CTERA Agent for Windows. June 2016 Version 5.5

Troubleshooting Microsoft Windows XP-based Wireless Networks in the Small Office or Home Office

Disclaimer. The names of actual companies and products mentioned herein may be the trademarks of their respective owners TOPS Software

EntraPass WebStation. Installation Manual DN

Symantec Endpoint Protection Installation Guide

BLUEPRINT TEAM REPOSITORY. For Requirements Center & Requirements Center Test Definition

HR-Lite Database & Web Service Setup Guide

Getting Started with Soonr

Status Web Evaluator s Guide Software Pursuits, Inc.

SynapSense Software. Installation Manual. Release 7.1 Issue 1

SonicWall Global VPN Client Getting Started Guide

Lasso Continuous Data Protection Lasso CDP Client Guide August 2005, Version Lasso CDP Client Guide Page 1 of All Rights Reserved.

OrthoFlow 1.1 Server Installation Manual

Veritas System Recovery 18 Management Solution Administrator's Guide

Symantec Backup Exec Quick Installation Guide

Enterprise Vault.cloud CloudLink Google Account Synchronization Guide. CloudLink to 4.0.3

U3 Encryption Utility User Guide

IEEE g Wireless PC Card. User s Guide

McAfee Install Instructions: Windows Vista

DICOM DIRECTOR. User Manual for. DICOM Director Gateway. DICOM Director Team Version 1.0

Transcription:

All Information provided in this document and in the accompanying software is subject to change without notice and does not represent a commitment on the part of RamSoft. RamSoft assumes no responsibility for any errors or consequential damages that may result from the use or misinterpretation of any information in this document. No part of this document may be reproduced in any form or by any means, electronic or mechanical, including photocopying and recording, for any purpose without the express written permission of RamSoft. MANUFACTURER RamSoft Incorporated 700 60, Adelaide St E Toronto, ON M5C 3E4 CANADA Toll Free: (888) 343-9146 Phone: (416) 674-1347 Fax: (416) 674-7147 Email: support@ramsoft.com Web Site: http://www.ramsoft.com RamSoft, RamSoft PACS are registered trademark of RamSoft Inc. PowerServer, PowerReader, PowerCache and Gateway are registered trademarks of RamSoft Inc. Microsoft and Windows are registered trademarks of Microsoft Corporation. M*Modal Speech Understanding is a registered trademark of MModal IP LLC. Dragon Medical is a registered trademark of Nuance Communications, Inc.

RamSoft Gateway Router 6.0 Quick Start Guide Contents 1 EXECUTIVE SUMMARY... 4 2 RECOMMENDED SYSTEM REQUIREMENTS... 4 2.1 Less than 30,000 studies per year... 4 2.2 More than 30,000 studies per year... 5 3 STEPS TO A QUICK START... 6 3.1 Installation... 6 3.2 Maintenance Settings... 6 3.3 Gateway Router Configuration... 8 3.4 Configuring Other DICOM Stations... 10 3.5 Simple Routing Rule Trigger Setup & Example... 10 4 SETTING UP A SECURE DICOM COMMUNICATION... 12 3

1 EXECUTIVE SUMMARY This guide is meant to help the users with setting up and starting a RamSoft Gateway Router 6.0 2 RECOMMENDED SYSTEM REQUIREMENTS 2.1 Less than 30,000 studies per year Required Hardware Requirements Operating System CPU RAM Hard Drive(s)/Primary Storage Network Bandwidth (LAN) Software Requirements Antivirus Remote Access Recommended Hardware Microsoft Windows 10 Pro (64-Bit) Recent CPU (less than 5 years old) with at least 4 Cores 8 GB RAID1, 2 x 500 GB Hybrid HDD, Database and Image storage sized appropriately 1,000 Mbps Recommended Software Windows Defender AVG Antivirus Business Edition AVG CloudCare LogMeIn will be supplied by RamSoft for the exclusive use of RamSoft Support. Optional Software Hard Drive Imaging Server Monitoring Recommended Software Windows Backup LogMeIn Pro 4

2.2 More than 30,000 studies per year Required Hardware Requirements Operating System CPU RAM Hard Drive(s)/Primary Storage Network Bandwidth (LAN) Software Requirements Antivirus Remote Access Recommended Hardware Windows Server 2016 Standard with Hyper-V Recent CPU (less than 5 years old) with at least 4 Cores 8 GB RAID1, 2 x 500 GB Hybrid HDD, Database and Image storage sized appropriately 1,000 Mbps Recommended Software AVG Antivirus Business Edition AVG CloudCare LogMeIn will be supplied by RamSoft for the exclusive use of RamSoft Support. Optional Software Hard Drive Imaging Server Monitoring Recommended Software Windows Backup, Veeam Backup & Replication (for Hyper-V) LogMeIn Pro 5

3 STEPS TO A QUICK START Increase productivity and maximize your resources in your fast paced medical imaging facility. RamSoft Gateway Router offers the features required to meet the present and future demands of an increasingly demanding operating environment. 3.1 Installation 1. Double-click on the Gateway Router Installer file. 2. At the Install Shield Wizard welcome screen, click Next. 3. Click the radio button I accept the terms in the license agreement. Click Next. 4. Type in the User Name and Organization. Click Next. 5. For the Database, Image, and Destination folders, use the default folder and click Next. 6. Click Install to begin the installation. 7. When the Install Shield Wizard has completed, click Finish. 8. When prompted to restart, click Yes. 3.2 Maintenance Settings 1. Launch the RamSoft PACS Maintenance application. 3. If you are on the evaluation version, a popup is displayed requesting you to either Purchase, Activate or use the Evaluation version. Make your selection. 4. When prompted for the Password, type in @dmin4m@int. 5. Go to Communication > DICOM > DICOM Configuration. 6

6. Type in the appropriate Local Station Name and Local AE Title. 7. If you do not wish to accept DICOM connections with all stations, uncheck the Allow receiving without verifying AE Title credentials (Promiscuous Receiving) option. 7

8. The RamSoft Software requires the AE title and Station Name to communicate with other DICOM stations. However, if you do not wish to define the Station Name and AE Title, then the Promiscuous Receiving option should be enabled. Enabling this option allows the RamSoft software to communicate with all DICOM devices. Warning: It is not recommended to enable Promiscuous mode for DICOM communication with other devices for a prolonged period of time. This mode should be only used for testing purposes. 9. Go to Services > Local Services > Restart. 10. After the services have been restarted, click OK. 11. Close the Maintenance module. 3.3 Gateway Router Configuration 1. Double-click the Gateway Router 6.0 shortcut on the desktop. 2. A form will be displayed requesting you to either purchase, activate or use the evaluation version. Make your selection. 3. When prompted for the User Name and Password, type in ADMIN and @dm!n4ps. 4. Go to Settings > Password. 5. Type in the Old Password @dm!n4ps and type in the desired custom password and confirmation. Click OK to commit changes. 6. Go to Settings > Server Settings > Station List. 7. In the Station List window, click New Station. 8

8. Type in the Station, IP Address, Port, and AE Title of the station you are going to connect with. This will be known as the Second Station. 9. Click Test Connection to test the connection. 10. Click Apply to commit changes and click OK again to close the window. 9

3.4 Configuring Other DICOM Stations 1. Launch the other DICOM station to which the Gateway router is to be connected. 2. Enter the Station, IP Address, Port, and AE Title of the Gateway Router. 3. Click the Test Connection button to ensure the DICOM connection succeeded. 4. Click OK to close the pop-up and click OK to close the window. 3.5 Simple Routing Rule Trigger Setup & Example 1. Go to Settings > Server Settings > Workflow. 2. By default, the Triggers tab appears. 3. Under Trigger Rules, click New. 4. Select the appropriate Rule Name, Status (after COMPLETED), Modality, and Body Part from the drop-down lists. The % symbol represents all selections. 5. Type in the appropriate Facility, Reading Physician, Referring Physician, and Origin AE Title. Click Save to commit changes. 6. Under Settings for the Selected Trigger Rule, select Routing. 7. Under the Destinations tab, click New. 8. Under Type, select Dicom/Replication Station. 9. Under Destination, select name of the second station. Click Save to commit changes. 10. Click OK to close the window. 11. Launch the other DICOM station (the one you wish to connect the Gateway Router with). 12. Create or modify a patient (e.g. Last name: GATEWAY, First name: ROUTER). 10

13. Enter the Facility, Reading Physician, and Referring Physician as entered in Step 5. 14. Modify the study Modality and Body Part to the ones in Step 4. 15. Send the study to the Gateway Router. 16. Go to the Gateway Router. Search for the patient study and open the Study Information form. Verify that the study information is the same (the Status may be different). 17. Change the Status to the Status in Step 4. Click OK to commit changes and close the window. 18. Go to Settings > Logs > Communication. Under the Transmit Log tab, under Pending, verify that the study has been placed in the queue. 19. Once transmission has been completed, go to the other DICOM Station. Search for the patient study and double-click to open the study. Verify that the patient, study information and the images are correct. 20. Close the study. 11

4 SETTING UP A SECURE DICOM COMMUNICATION Gateway Router allows encrypted DICOM communication using TLS encryption. DICOM communication encryption and authentication is done through SSL keys and certificates. By providing each machine with a copy of the public certificate, the need for using a third party Certificate Authority is eliminated, making this a fully secure authentication system where the only concerned parties are the two machines performing a DICOM transaction. Note: TLS communication should only be set up if DICOM communication is taking place across an unsecured channel, such as the Internet. If the DICOM machines are all enclosed within a secure Local Area Network or a VPN, TLS does not need to be setup as it is not necessary. The following procedure describes the setup of a secure DICOM communication: 1. Go to %\RamSoft\GatewayRouter\Tools. 2. Execute Makecert.bat in Command Prompt. 3. Enter the prompted information. 4. The utility will create a private key (pacs.key) and a public certificate (pacs.crt); both are placed in the tools directory. 5. Place the certificate (pacs.crt) in the %\RamSoft\GatewayRouter\Certificates folder on every machine that will be involved in the DICOM communication. This eliminates the need for a Local Certificate Authority. 6. Launch Maintenance. 7. Go to Communication > Dicom > Dicom Configuration. 8. Point the certificate field to the pacs.crt file that was created. 9. Point the key field to the pacs.key file that was created. 10. Point the Peer Certificates field to the Certificates folder. 12

11. Click OK. 12. DICOM Services should be restarted at this point at Services > Local Services > Restart 13. Open Gateway Router. 14. Go to Settings > Server Settings > Station List. 15. Change the default unencrypted port 104 to the TLS encrypted port 2762 for the station you wish to connect to. Note: For each station in the list, the default unencrypted port is 104 and the default TLS encrypted port is 2762. 15. Select the DICOM tab. 16. For each station using encryption, enable the Encrypt Data (TLS) option. 17. Click on the Test Connection button. 18. If the steps above have been followed properly, the communication should be successful. 1994-2018 RamSoft, Inc. All Rights Reserved. 06/18C RamSoft, Inc. reserves the right to make changes to specifications and features contained herein or discontinue the product described without notice or obligation. 13