MP-2000 Dual Channel LVDT/RVDT Readout/Controller

Similar documents
Dual Channel LVDT/RVDT Readout/Controller

ED-21 Analog Output Series Magnetic Encoder

MICRO SERIES PROCESS DISPLAYS LARGE DIGIT MODELS

PRODIS. PD-ADC Digital Process Meter for analog Sensors. Digital Process Meters. Datasheet

Model 8042 Submersible Accelerometer

LAUREL. Laureate Digital Panel Meter for Process and Ratiometric Signals ELECTRONICS, INC. Features. Description

LAUREL ELECTRONICS, INC.

The IQ300 wall mount load cell indicator is a precision digital indicator for load cell and strain gauge applications.

DXP-40 FEATURES APPLICATIONS DESCRIPTION CONFIGURATION

FPS2800B12C4 Fluid Property Sensor Module

Model SC500. Programmable Single-Channel Transducer Indicator/Conditioner DESCRIPTION FEATURES

Wide Bandwidth Strain Gage Input 3B18 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

Isolated Wideband Voltage Input 3B40 / 3B41 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

Isolated Voltage Input 7B31 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

U7100 Pressure Transducer

The IQ240 panel mount load cell indicator is a precision digital indicator for load cell and strain gauge applications.

T600 TACHOMETER MultiTasker - a measurement & monitoring instrument with 2 frequency and 1 analog inputs

Isolated Voltage Input 3B30 / 3B31 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

Isolated Process Current Input with Loop Power 7B35

LAUREL. Laureate RTD Temperature Panel Meter / Controller ELECTRONICS, INC. Features. Description. Specifications

OBSOLETE. Isolated, Linearized, Thermocouple Input 3B47 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

LAUREL. Laureate Dual-Channel Pulse Input Totalizer With Two Independently Scalable Input Channels & Presets ELECTRONICS, INC. Features.

Isolated, Voltage or Current Input 7B41 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

Isolated Process Current Input 7B32 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

The PM1000 series is a universal 4 digit LED plug-on display for transmitters with 4-20mA 2 wire output and fitted with DIN43650 connector.

M5100 Heavy Industrial Pressure Transducer

TC Type Range Conformity Error. J -210 C to +760 C (-347 F to F) ±0.09 C (±0.16 F) K -244 C to C (-408 F to F) ±0.1 C (±0.

LAUREL. Laureate Digital Panel Meter for Load Cell & Microvolt Input ELECTRONICS, INC. Features. Description

Isolated Process Current Output 3B39 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

OPERATION MANUAL PML-1000

Isolated, Voltage or Current Input 7B30 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

MYRIAD QLC 4-CHANNEL MONITOR/CONTROLLER INSTRUCTION MANUAL

Y800 Plus Frequency, Rate & Period Meter With dual, independently field-scalable channels

MYRIAD LC1 LEVEL CONTROLLER INSTRUCTION MANUAL

INSTALLATION MANUAL. LC 200 Electronic Overload Guard. Software versione PW0501 R 0.3

MODCELL 2050R Single Loop Controllers

DFI 7000 DIGITAL FORCE INDICATOR USER S GUIDE 1.0 INTRODUCTION 2.0 DESCRIPTION. 2.1 Configuration. 2.2 Specifications

Isolated, Process Current Output 7B39 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

High Voltage DC Meter

The LT1300 wall mount load cell indicator is a precision digital indicator for load cell and strain gauge applications.

Cole-Parmer Instrument Company

MODEL 9250 Preliminary data sheet

HIGH-VOLTAGE DC METER

Batch Controller with numerical keypad, remote control inputs and 3 control / alarm / pulse outputs

ORDERING INFORMATION # of Ports Pressure Type Device Name

ph/orp 300 (Cat. No ) MICROCOMPUTER BASED OPERATION MANUAL ph /ORP/ Temperature CONTROLLER Phone: , Fax:

D-Series Inclinometer

M7100 Pressure Transducer

Si 2035 Programmable Stepper Drive

Standard Options. Model 4100 Position Indicating Meter. Three Phase Motor Control. Positran Transmitter

LAUREL. Laureate Pulse or Analog Input Batch Controller Automatic batch control for repetitive liquid fill operations ELECTRONICS, INC.

Amplifiers, Counters, Timers & Controls

GFC114. Low Power Flow Computer FEATURES

D1000M SERIES FOR MODBUS SENSOR TO COMPUTER INTERFACE MODULES

TURCK Process Automation IS Interface Technology. Interface Modules. IM Series Cabinet

System StrainSmart Data Acquisition System. Micro-Measurements FEATURES DESCRIPTION MODEL 5100B SCANNER SPECIFICATIONS

Operation Manual TX10 1/8 DIN Microcomputer Based ph/orp Controller

Eco Sensors OZONE CONTROLLER Model OS-6 Instructions for Use. General and New Features

TABLE OF CONTENTS INTRODUCTION. 3. Analog Input Analog Output Digital Input Digital Output OPERATIONAL DESCRIPITON.. 7 PROGRAMMING AND INITIAL SETUP.

USER MANUAL EAZY-CAL LVC-4000 LVDT Signal Conditioner

12-36 VDC/12-24 VAC Power Option 4-Digit Display, 0.56 (14.2 mm) or 1.20 (30.5 mm)

StrainSmart Data Acquisition System

SINGLE-CHANNEL PROCESS CONTROLLERS & TEMP. DISPLAYS D3820/D3830 Series

EAZY-CAL LVC-4000 LVDT Signal Conditioner User Manual

Peak/Valley Hold Unit (PVHU) User Manual V3.00

Freescale Semiconductor Data Sheet: Technical Data

LAUREL. Laureate Rate Meter & Totalizer with Functions A+B, A-B, AxB, A/B, A/B-1 ELECTRONICS, INC. Features. Description

1.6. Counters, Panel Meters, Tachometers and Timers. Contents Description Fusion Integrated Machine Control Standards and Certifications...

DPL/DPN-Series Inclinometer

Process displays For current and voltage

INTRINSICALLY SAFE INSTRUMENTATION FOR HAZARDOUS AREAS

MPXHZ6130A, 15 to 130 kpa, Absolute, Integrated Pressure Sensor

Eco Sensors OZONE CONTROLLER Model OS-6 Instructions for Use. General and New Features

MTS-2000 USER S MANUAL

ES-600 Ozone Controller Operation Manual

SA SERIES Arlingate Lane, Columbus, Ohio (614)

5450 NW 33rd Ave, Suite 104 Fort Lauderdale, FL Fruitland Ave Los Angeles, CA SST7000 SST7100. Speed Switch / Transmitter

LAUREL ELECTRONICS, INC.

MPXH6300A, 20 to 300 kpa, Absolute, Integrated, Pressure Sensor

Panel Indicators. NEW 4~20mA Panel Display. Process Indicators INTECH INSTRUMENTS.

OZONE SWITCH Model OS-6. OS-6 Features

NFC110. Flow Computer For Low Pulses FEATURES

NPA. Amphenol Advanced Sensors. Surface-Mount Pressure Sensor Series. Features

dual-line 6-dIGIt process MeteR

MODEL USB-DA12-8E Eight Channel Digital to Analog Converter USER MANUAL

APPLICATION GUIDE. Interface Modules IM Series.

Weight Indicator. Model Intuition 22i FEATURES APPLICATIONS DESCRIPTION OPTIONS CONFIGURATION

H3 Series. Nanmac Corporation. Dual-Line 6-Digit Temperature Meter.

SGJ Cable Actuated Sensor Industrial CANBus J1939

D7000 SERIES MODBUS TCP/IP ETHERNET INTERFACE MODULES

PD765 TRIDENT. Trident Series Process & Temperature Meters.

Temperature, Process &

Isolated, Field Configurable Analog Input 6B11 / 6B11HV FEATURES APPLICATIONS PRODUCT OVERVIEW

LAUREL. MAGNA Series Large Digit Displays for Counter / Totalizer Pulse Input ELECTRONICS, INC. Features. Description

MP3V5050, 0 to 50 kpa, Differential, and Gauge Pressure Sensor

NF760 Batch Controller

BXD17 Series. Features. Analytical instrumentation for your measurement applications.

E101 - Strain Gauge Transducer Display Module. Contents

Display and Monitoing Units

CSI 6300 SIS Overview

Transcription:

Large backlit dual channel display Menu driven setup and calibration 100 to 240 VAC line powered MIN, MAX, TIR, A+B and A-B functions 2.5, 3.3, 5 and 10kHz selectable excitation Analog and RS232 outputs Four user programmable set-points Splash-proof front panel with status LEDs ¼ DIN standard panel mounting DESCRIPTION The MP-2000 is a dual channel, microprocessor based readout and set-point controller designed for industrial and process control applications utilizing any LVDT/RVDT-based measurement device. In addition to displaying real-time readings of LVDTs, RVDTs and gage heads, the MP2000 is also capable of displaying values such as MIN, MAX, TIR (Total Indicated Run-out), A+B (sum of two channels) and A-B (difference between two channels). A 17-bit analog-to-digital converter provides excellent performance and resolution, while a standard 9- pin RS-232 communications interface provides serial data output to a PLC or PC COM port. The MP-2000 features four user-programmable, opto-isolated, open-collector set-point outputs, which can be used to monitor any display parameter. Any combination of high or low set-points may be selected, while programmable high and low hysteresis values may be used to create set-point dead band for prevention of control relay chatter. For the control of external relays, an optional Relay Board with a current handling capability of 5A per relay is available and highly recommended. A front panel pushbutton permits auto-zeroing (tare) over the full range. Auto-calibration eliminates calculation of slope or gain factors. All calibration and setup parameters are stored in nonvolatile memory for retention on power down or interruption. The zero and min/max reset functions can be hard wired for remote control. The large, easy to read, bit-mapped display provides user-friendly, menu driven prompts for simple push-button system setup, calibration, and monitoring of inprocess measurement parameters. A real-time scaled analog output, proportional to the digital readout is provided for each LVDT channel. An RS-232 output is provided for data transfer to a computer at 1200 to 19.2K baud. Also see our other LVDT/RVDT signal conditioner models: LiM-420 LVM-110 LDM-1000 ATA-2001 IEM-422 PML-1000 24VDC supply, 4-20mA (3-wire) output, open circuit board ±15VDC supply, ±10 and 0 to 10VDC outputs, open circuit board 10 to 30VDC supply, DC voltage and 4 to 20mA outputs, DIN rail mountable Line powered, DC voltage and current outputs, push-button programmable Line powered, 4-20mA output, NEMA-13 rated enclosure AC or DC supply, DC voltage, current and RS485 outputs, 1/8 th DIN panel meter, Measurement Specialties, Inc. (NASDAQ MEAS) offers many other types of sensors and signal conditioners. Data sheets can be downloaded from our web site at: http://www.meas-spec.com/datasheets.aspx MEAS acquired Schaevitz Sensors and the Schaevitz trademark in 2000. FEATURES APPLICATIONS Versatile dual channel display Pass/fail part sorting Software selectable gain and excitation Concentricity/roundness gaging 4 user-programmable set-points with LED indicators Press cycle control Master/Slave sync input/output for multiple MP-2000s Part classification Remote zero and min/max reset Material thickness measurement Rugged extruded aluminum housing Industrial process control 1/5

PERFORMANCE SPECIFICATIONS Power requirements ELECTRICAL SPECIFICATIONS 100 to 240 VAC ±10%, 47 to 63Hz Display Digits (5) 0.4 [10] high, bitmapped LCD, electroluminescent backlit Range ±99999 Decimal point position User selectable Annunciator lights (LED) Each of the four set-points, zero, and preset Voltage Oscillator frequency Current drive capability Transducer type Full scale output Input (primary) impedance Input sensitivity range Input impedance Non-linearity Unipolar voltage output Bipolar voltage output Response Description Hysteresis (dead band) Outputs Relay board (optional and highly recommended Type Speed Transducer excitation 1 or 3Vrms (user selectable) 2.5, 3.3,5 or 10kHz (user selectable) 25mA maximum per LVDT Transducer requirements LVDT or RVDT with 5 or 6 electrical connections 0.36 to 1.2VRMS 40Ω min with 1VRMS excitation; 120Ω min with 3VRMS excitation Amplifier characteristics (transducer input) High gain: 0.36 to 0.6VRMS; Low gain: 0.72 to 1.2VRMS 100kΩ minimum ±0.02% of FSO, maximum Analog output 0 to +10VDC ±5VDC (may be over-ranged to ±10VDC) 20mS Set-points 4 user programmable, high or low, with LED indicators User programmable Opto-isolated, open collector logic outputs, 5VDC, 4mA per set-point Four relays, NO and NC contacts Maximum switching capability (each relay): 50VAC/30VDC, 5A Serial communications RS232 1200, 2400, 4800, 9600, or 19200 baud (user selectable) ENVIRONMENTAL AND MECHANICAL SPECIFICATIONS Operating temperature range Mounting Depth behind panel (installed) +32 F to +131 F [0 C to +55 C] ¼ DIN panel mount 7.7 [196] with optional relay board installed (plugged into J4 connector) Note: All values are nominal unless otherwise noted Dimensions are in inch [mm] FSO (Full Scale Output) is the largest absolute value of the outputs measured at the range ends 2/5

CONNECTIONS (REAR PANEL) See operation manual for details: http://www.meas-spec.com/downloads/mp_2000_operating_instructions.pdf DIMENSIONS Dimensions are in inches [mm] 3/5

RELAY BOARD (SOLD SEPARATELY) RACK ADAPTOR (SOLD SEPARATELY) Accommodates up to four MP-2000 Readout/Controllers Dimensions are in inches (mm) 4/5

ORDERING INFORMATION Description Part Number MP-2000 Dual Channel LVDT/RVDT Readout/Controller 02291335-000 Rack Adaptor for up to 4 readout/controllers 05290032-000 (optional - MP-2000 readout/controllers not included) Relay Board (optional and highly recommended) 74170000-000 Operation manual: http://www.meas-spec.com/downloads/mp_2000_operating_instructions.pdf TECHNICAL CONTACT INFORMATION CANADA Durham Instruments 900 McKay Road, Unit 3 Pickering, ON L1W 3X8 Tel: 905-839-9960 Fax: 905-839-4325 Email: sales@disensors.com The information in this sheet has been carefully reviewed and is believed to be accurate; however, no responsibility is assumed for inaccuracies. Furthermore, this information does not convey to the purchaser of such devices any license under the patent rights to the manufacturer. Measurement Specialties, Inc. reserves the right to make changes without further notice to any product herein. Measurement Specialties, Inc. makes no warranty, representation or guarantee regarding the suitability of its product for any particular purpose, nor does Measurement Specialties, Inc. assume any liability arising out of the application or use of any product or circuit and specifically disclaims any and all liability, including without limitation consequential or incidental damages. Typical parameters can and do vary in different applications. All operating parameters must be validated for each customer application by customer s technical experts. Measurement Specialties, Inc. does not convey any license under its patent rights nor the rights of others. 5/5