MANUAL MODULAR SEGMENT PROTECTOR

Similar documents
MANUAL Surge Protectors

PROCESS AUTOMATION MANUAL FIELDBUS POWER HUB INVENSYS

PROCESS AUTOMATION INSTRUCTION MANUAL FIELDBUS SURGE PROTECTOR F*-LBF-I1.32 F*-LBF-D1.32

PROCESS AUTOMATION. MANUAL Z-System. Zener Barriers ISO9001

PROCESS AUTOMATION. MANUAL Compact Fieldbus Power Hub, Common Interface

Segment Protector for Cabinet Installation R2-SP-IC* Features. Assembly. Function. Connection. Trunk, Ex na non-arcing. Spur.

Segment Protector for Cabinet Installation R2-SP-IC* Features. Assembly. Function. Connection. Trunk, Ex na non-arcing. Spur.

MANUAL Functional Safety

MANUAL Functional Safety

FACTORY AUTOMATION MANUAL ODZ-MAH-B15-M3

MANUAL LML-P, LML-S, LML-Ex

FACTORY AUTOMATION MANUAL WCS-MBG110 WCS MODBUS RTU INTERFACE MODULE

MANUAL SEGMENT CHECKER

MANUAL FieldConnex Basic Segment Coupler

PI-EX-ME-2NAM/COC-24VDC

MANUAL VAA-2E2A-G12-SAJ/EA2L Original Instructions Version 1.0

PHOENIX CONTACT - 12/2007

MANUAL Functional Safety

PI-EX-ME-2NAM/COC-120VAC

5 Fieldbus Technology

FACTORY AUTOMATION. MANUAL VAA-2E-G4-SE Original Instructions Version 1.1

RAD-DO8-IFS. I/O extension module, eight digital transistor outputs. Data sheet. 1 Description

SAFETY MANUAL SIL Switch Amplifier

Redundancy unit CP-A RU

Operating Manual / IEC. Explosion-Proofed Junction Boxes, Polyester. Wallücker Bahndamm 7 DE Kirchlengern

PROCESS AUTOMATION MANUAL F2-SP-IC*

FACTORY AUTOMATION MANUAL PMI360D-F130-IE8-V15 INDUCTIVE POSITIONING SYSTEM

MINI MCR-SL-RPS-I-I. Repeater power supply, active. Data sheet. 1 Description

Operating Instructions

DI561 Digital Input Module

PROCESS AUTOMATION MANUAL. Temperature Trip Amplifier. KFD2-GU-(Ex)1 ISO9001

Operating instructions. Switching amplifier DN0210 DN / / 2015

RAD-DI8-IFS. I/O extension module with 8 digital inputs or 2 pulse inputs. INTERFACE Data sheet. 1 Description

TU531, TU532 Terminal Unit

PROCESS AUTOMATION MANUAL. Universal Transmitter Power Supply. KF**-CRG2-(Ex)1.D ISO9001

MINI-PS AC/10-15DC/8

RAD-DOR4-IFS. I/O extension module, 4 digital relay outputs. INTERFACE Data sheet. 1 Description

RTU500 series Data Sheet Power Supply CP-E 24/2.5

SYSTEM DESCRIPTION H-System

Siemens Spares. Preface 1. Scope of Delivery 2 SIPLUS CMS4000. Product Characteristics 3 ION PROFIBUS DP SPY T001 Installation and Maintenance 4

QUICK START GUIDE ODT-HH-MAH300 Handheld

Operating instructions AS-i SmartLine module AC3200 AC /00 06/2016

Part No. Description Product Life Cycle Phase *) unit, 24 VDC, spring terminals. unit, 24 VDC, spring terminals, XC version

DI572 Digital Input Module

AI561 Analog Input Module

PROCESS AUTOMATION MANUAL. Universal Temperature Converter KCD2-UT2-(Ex)1 ISO9001

FLEX Ex Spring Clamp Terminal Base

TF501, TF521 Terminal Bases

Operating instructions. Speed monitor D / / 2014

Assembly. Front view. LED yellow: Relay output. LED red: LB/SC Power Rail

DC561, digital input/output module,

DC562, digital input/output module,

ETD-BL-1T-OFF-CC- 10S

INSTRUCTION MANUAL WCS-Interface Module, DeviceNet

MANUAL Temperature Multi-Input Device

PHOENIX CONTACT - 05/2007

Electronic timer CT-ERD.12

DX561 Digital Input/Output Module

MINI MCR-SL-UI-2I. Configurable signal duplicator. Data sheet. 1 Description

Operating instructions. Standstill monitor A / / 2011

TRIO-DIODE/12-24DC/2X10/1X20

AO523 Analog Input Module

Instruction Manual. T3110 T3110L T3110Ex

Assembly MAU. MUX 4 Channels 8 Channels Zone 1

MACX MCR-EX-SD LP(-SP)

Zener Barriers Bulletin 937Z

Signal processor MS96 for flow sensors MS96-11EX0-R/230VAC

INSTRUCTION MANUAL. Universal AC Input Switching Power Supply 24 Vdc Output DIN-Rail Models PSD1000, PSD1000F PSD PSD1000F

MANUAL HART Multiplexer System

AO561 Analog Output Module

MINI MCR-SL-PT100-UI(-SP)(-NC)

MINI MCR-SL-PT100-UI-200

MINI MCR-SL-CVS NC

CM592 PROFIBUS Communication Module

REDUNDANCY MODULE TSP-REM360 AND TSP-REM600

Installation manual plugs and connectors with screw connection (16/32 A)

CompactBlock Guard I/O EtherNet/IP Safety Modules

Description. SIMATIC Sensors. RF systems Wide-range power supply unit for SIMATIC RF systems. Operating Instructions 11/2007 J31069-D0169-U001-A4-7618

PROCESS AUTOMATION MANUAL. Temperature Converter. HiC2081, HiD2081, HiD2082 ISO9001

DT1102 V (PS) Fully Configurable Galvanic Isolator. Operating Instructions

PTB 01 ATEX 2064 U, IECEx PTB U. Example / Beispiel / Exemple: Type Operating Instructions

Operating Instructions (Translation) 3. Safety Information. 1. Description. 2. Explosion Protection. Supply module Type 17-21BB-170x

FACTORY AUTOMATION INSTRUCTION MANUAL. AS-Interface Safety at Work VAA-2E-G4-SN. Version 1.2

FACTORY AUTOMATION. MANUAL OHV-F230-B17 PROFINET Gateway for OHV Handheld

PROCESS AUTOMATION YOUR PARTNER FOR INDUSTRY-SPECIFIC INSTALLATION SOLUTIONS FIELD JUNCTION BOX

MINI MCR-SL-PT100-UI. Active resistance thermometer measuring transducer. Data sheet. 1 Description

Operating instructions

Electronic timer CT-AHD.22

Power supply CP-E 48/1.25 Primary switch mode power supply

SUBCON-PLUS-PROFIB...

ADAMCZEWSKI. Ordering data AD-STVEX 710 GVD Option: Factory-software configuration as per customer specifications.

Power supply CP-C 24/5.0

Operating instructions Safe AS-i input module ASIM-C-M About this document. Content

Rhino Buffer Module PSM24-BFM600S. Operating Instructions

MANUAL AS-INTERFACE Handheld

MANUAL Functional Safety

Operating Manual. English. Digital-Analog Converter DACON8-UMB.

PHOENIX CONTACT - 08/2009. Features. DANGER OF EXPLOSION! Only remove equipment when it is disconnected and not in the potentially explosive area.

Operating Instructions

FACTORY AUTOMATION MANUAL PMI360DV-F130-IU2E2- V15

Transcription:

PROCE AUTOMATION MANUAL MODULAR EGMENT PROTECTOR RM-P*

With regard to the supply of products, the current issue of the following document is applicable: The General Terms of Delivery for Products and ervices of the Electrical Industry, published by the Central Association of the Electrical Industry (Zentralverband Elektrotechnik und Elektroindustrie (ZVEI) e.v.) in its most recent version as well as the supplementary clause: "Expanded reservation of proprietorship"

Contents 1 afety... 4 1.1 Validity...4 1.2 ymbols used...4 1.3 ystem Operator and Personnel...4 1.4 Pertinent Laws, tandards, Directives, and further Documentation...5 1.5 Delivery, Transport and torage...5 1.6 Marking...5 1.7 Intended Use...5 1.8 Installation and Commissioning...6 1.8.1 egment Protectors pecial Mounting Requirements...6 1.8.2 Requirements Zone 2...6 1.8.3 Ex nl...6 1.9 Housing...7 1.10 Repair and Maintenance...7 1.11 Disposal...7 2 Product pecifications... 8 2.1 Functional description...8 2.2 Device Component Overview...9 2.2.1 tatus and error messages...9 2.3 Technical Data...10 3 Installation and Commisioning... 11 3.1 Mounting...11 3.2 Demounting...13 3.3 RM-PTM-N2 Connection Layout...14 3.4 RM-PEM-N4 Connection Layout...15 3.5 Grounding / hielding of Fieldbus Transmission Lines...16 3.6 eries Connection and Termination...17 4 Appendix... 18 4.1 Ordering Information...18 4.2 Electromagnetic Compatibility Verification in Accordance with EC Council Legislation Directive 2004/108/EC...18 4.3 Referenced Documents...19 3

afety 1 afety 1.1 Validity pecific process and instructions in this document require special precautions to guarantee the safety of personnel. 1.2 ymbols used This document contains information that you must read for your own personal safety and to avoid property damage. The warning signs are displayed in descending order depending on the hazard category, as follows: afety-relevant symbols Danger! This symbol indicates a warning about a possible danger. In case of ignoring the consequences may range from personal injury to death. Warning! This symbol indicates a warning about a possible fault or danger. In case of ignoring the consequences may cause personal injury or heaviest property damage. Caution! This symbol warns of a possible fault. In case of ignoring the devices and any connected facilities or systems may be interrupted or fail completely. Informative symbols Note! This symbol brings important information to your attention. Action This symbol marks an acting paragraph. 1.3 ystem Operator and Personnel The plant owner is responsible for its planning, installation, commissioning, operation, maintenance and disassembly. Mounting, commissioning, operation, maintenance and dismounting of any devices may only be carried out by trained, qualified personnel. The instruction manual must be read and understood. 4

afety 1.4 Pertinent Laws, tandards, Directives, and further Documentation Laws, standards, or directives applicable to the intended use must be observed. In relation to hazardous areas, Directive 1999/92/EC must be observed. The corresponding data sheets, declarations of conformity, EC Type-examination certificates, certificates and Control Drawings if applicable (see data sheet) are an integral part of this document. You can find this information under www.pepperlfuchs.com. 1.5 Delivery, Transport and torage 1.6 Marking Check the packaging and contents for damage. Check if you have received every item and if the items received are the ones you ordered. Keep the original packaging. Always store and transport the device in the original packaging. Always store the device in a clean and dry environment. The permitted storage temperature (see data sheet) must be considered. The modules are product-specifically marked with: RM-PTM-N2 RM-PEM-N4 Pepperl+Fuchs GmbH Pepperl+Fuchs GmbH 68301 Mannheim/Germany 68301 Mannheim/Germany Trunk Module Extension Module RM-PTM-N2 RM-PEM-N4 TÜV 11 ATEX 081152 X TÜV 11 ATEX 081152 X 1.7 Intended Use II 3 G Ex na [nl] IIC T4 II 3 G Ex na [nl] IIC T4 The RM-P-N* egment Protectors are couplers for fieldbus according to IEC 61158-2 to connect field devices through spurs to the trunk of a fieldbus segment. Each spur individually limits the current in case of a failure ensuring that the remaining segment is not affected. The egment Protector provides a certified Ex nl energy limitation at each spur connection. The devices are only approved for appropriate and intended use. Ignoring these instructions will void any warranty and absolve the manufacturer from any liability. The device must only be operated in the ambient temperature range and at the relative humidity (non-condensing) specified. 5

afety 1.8 Installation and Commissioning 1.8.1 egment Protectors pecial Mounting Requirements The device is designed for installation on a 35 mm DIN mounting rail in accordance with DIN EN 60715. Take the cable parameters to be used from the installation instructions of the corresponding Fieldbus system and from the tatement of Conformity. During installation of egment Protectors, the following parameters must be strictly followed: The permissible core cross-section is 0.2 mm² to 2.5 mm². The insulation stripping length of strands is 7 mm. Whenever finely stranded conductors must be used, the strand ends must be protected from fraying, for example by using end splices. The following identifying values must be observed when connecting Fieldbus transmission lines: Tightening torque for the screw terminals should be 0.5... 0.6 Nm. The connectors are qualified for pulling and plugging at temperatures higher than -40 C. Within a segment, the physically last egment Protector has to be equipped with a fieldbus terminator type M-FT. 1.8.2 Requirements Zone 2 1.8.3 Ex nl Connection or disconnection of energized non-intrinsically-safe circuits is only permitted in the absence of a hazardous atmosphere. The devices may only be installed and operated in zone 2 if they have been mounted in an enclosure with degree of protection IP 54 according to IEC/EN 60529. The enclosure must have a declaration of conformity according to 94/9/EC for at least category 3G. egment Protectors Zone 2 pecial Requirements pecial care must be taken if power supply modules are to be used in conjunction with Pepperl+Fuchs segment protectors for energy limited Ex nl field wiring. A check must be made to ensure that the correct type of power supply module is used in relation to its output values. For example, the output voltage must be equal or less than the maximum voltage of the connected field devices. Requirements for all used fieldbus products in Zone 2 installations are summarized in the manual: "Using Pepperl+Fuchs fieldbus equipment in Zone 2 hazardous area environment". This document is available separately. Circuits of type of protection " Ex nl" (limited energy) that are operated with circuits of other type of protections must not be used as "Ex nl" circuits afterwards. 6

afety 1.9 Housing If additional housings are needed for installation in hazardous areas, the following points must be considered / evaluated: Degree of protection as per IEC/EN 60529 Light resistance as per IEC/EN 60079-0 Impact strength as per IEC/EN 60079-0 Chemical resistance as per IEC/EN 60079-0 Heat resistance as per IEC/EN 60079-0 Electrostatics as per IEC/EN 60079-0 To ensure the IP degree of protection: all seals must be undamaged and correctly fitted all screws of the housing / housing cover must be tightened with the appropriate torque only cable of the appropriate size must be used in the cable glands all cable glands must be tightened with the appropriate torque all empty cable glands must be sealed with sealing plugs 1.10 Repair and Maintenance 1.11 Disposal The devices must not be repaired, changed or manipulated. If there is a defect, the product must always be replaced with an original device. Disposing of devices, packaging material, and possibly contained batteries must be in compliance with the applicable laws and guidelines of the respective country. 7

Product pecifications 2 Product pecifications 2.1 Functional description The Modular egment Protector is a smart wiring interface for fieldbus distribution with short circuit protection at each output. It is designed for fieldbus systems according to IEC 61158-2 such as FOUNDATION Fieldbus H1 or PROFIBU PA. Communication and power distribution share the same two-wire cable using Manchester Bus Powered (MBP) coding. The modules of the egment Protector can be snapped side-by-side on the DIN rail. A system plug which clips on the DIN-Rail interconnects individual modules. The fieldbus trunk is connected to the Trunk Module RM-PTM-N2. It also provides two outputs for field devices named spurs. Extension Modules RM- PEM-N4 add four spur connections each to the Trunk Module. Tailored solutions can easily be engineered and built. egment extension is possible for a total of 26 purs per Trunk Module. The egment Protector is specifically suited for control cabinet installation. Any grounding and shielding concept is supported allowing optimal segment design. The egment Protector is certified for installation in Zone 2. egment Protectors in conjunction with power supplies such as the basic power supply KLD2-FBP-1.25.360 implement the High-Power Trunk concept. This concept enables maximum cable lengths and highest number of devices in any explosive area: The egment Protector provides Ex nl energy limitation at each spur connection. Utilizing egment Protectors, field devices can be installed in Zone 2 and maintained while the system is energized. Field instrumentation is connected one per spur connection. Each spur is equipped with short-circuit current limitation at 58 ma. If a short circuit or overload should occur at a spur, the fieldbus trunk and all other field devices remain in operation. When the fault is repaired, the egment Protector automatically resumes operation of the spur. This feature and the over voltage protection at 39 V make fieldbus segments extremely reliable. A fieldbus terminator with high-availability circuitry is included with each Trunk Module. There is a well-defined place, the open trunk output connector at the last module on the segment where the terminator is installed. Termination is clearly visible to installation personnel. This design further increases availability of fieldbus in two ways: The connection is secured by screws; and proper termination resulting in good quality signal levels is ensured. One LED each indicates bus communication activity, yellow and flashing and power on the trunk, green. Each output is equipped with a red LED for indication of a short-circuit condition or fault at the spur. The Modular egment Protector is best suited for cabinet installation and applications where frequent changes and modifications are expected. It protects fieldbus segments from short-circuit conditions at each spur and features energy limitation for hazardous area Zone 2. Electronic design further contributes to superior plant availability. 8

Product pecifications 2.2 Device Component Overview 1 3 2 4 O + I + Trunk IN/OUT 4 + 3 + purs RM-PTM-N2 RM-PEM-N4 PWR COM 5 6 7 ERR4 ERR3 PWR 94 (3.8") ERR1 ERR2 5 ERR1 ERR2 purs purs 1 + 2 + 1 + 2 + 17,5 (0.7") 58,6 (2.4") 4 4 8 69,5 (2.8") 1 Trunk Module RM-PTM-N2 2 Extension Module RM-PEM-N4 3 Trunk connection 4 pur connection 5 LED pur (Error) 6 LED PWR (Power) 7 LED COM (Communication) 8 Fixing strap All dimensions in millimeters (mm) and inch ('') without tolerance indication 2.2.1 tatus and error messages LED ERR LED COM LED PWR Red, short-circuit Yellow flashing, bus activity Green, Fieldbus Power present 9

Product pecifications 2.3 Technical Data Fieldbus Interface Power loss typ. Trunk: Rated Voltage Rated Current purs: Rated Voltage Rated Current hort-circuit current RM-PTM-N2 0.2 W 0.1 W 9...31 VDC 4.5 A 31 VDC 43 m A 58 m A RM-PEM-N4 Current consumption typ. 7 ma 3.5 ma Voltage drop trunk/spurs 1.3 V Terminator 100 Ohm external urge protection: Trunk overvoltage protection typ. 39 V, max. 41 V Ambient conditions -40...70 ºC (233...343 K) Operating temperature torage temperature -40...85 ºC (233...358 K) Mechanical Data crew terminals, removable Connection type Core cross-section 2.5 mm² Note! For characteristic values in conjunction with hazardous areas, please refer to the data sheet Note! Calculations for Total ystem Values Total power loss = 0.2 W + n * 0.1 W Total current consumption = 7 ma + n * 3.5 ma n = number of Extension Modules RM-PEM-N4 10

Installation and Commisioning 3 Installation and Commisioning 3.1 Mounting Note! Read chapter afety see chapter 1, especially all relevant sections for your kind of use before performing any work. The mounting of the Modular egment Protector is performed in two steps: 1. Preparing and mounting of the Bus Connector Modules. 2. Mounting of one Trunk Module and the several Extension Modules Preparing and Mounting the RM-BP Bus Connector Module 1. Plug the Bus Connector Modules together. Each Trunk and Extension Module requires one Bus Connector Module. 2. Attach the connected Bus Connector Modules to the DIN rail. 11

Installation and Commisioning Mounting the RM-P* Trunk and Extension Modules on the DIN rail Caution! Communication Loss Communication problems may occur while mounting and dismounting modules under live conditions. 1. Place the Trunk Module above the mounted Bus Connector Modules on the DIN rail. 2. Carefully lock in place the module. Click! 3. Repeat step 1 and 2 with all Extension Modules. O + I + TrunkIN/OUT RM-PTM-N2 4 + 3 + purs RM-PEM-N4 ERR4 4 3 + + purs RM-PEM-N4 ERR4 ERR3 ERR3 PWR PWR PWR COM ERR1 ERR1 ERR1 ERR2 ERR2 ERR2 purs 1 + 2 + purs 1 + 2 + purs 1 + 2 + The DIN rail mounting of the egment Protectors must mesh securely with the rail. The egment Protectors must be fixed firmly on the rail. 12

Installation and Commisioning 3.2 Demounting Dismounting is performed in the reverse order. Demounting the RM-P* 1. Use a screw driver to loose the fixing trap and remove the module from the DIN rail. 2. Repat step 1 with all modules. Demounting the RM-BP Push the combined Bus Connector Moduls sideways out of the DIN rail. 13

Installation and Commisioning 3.3 RM-PTM-N2 Connection Layout 4 3 2 1 1 pur Connection 1 2 pur Connection 2 3 Trunk In Connection 4 Trunk Out Connection Terminal Assignment hield connection - Channel - + Channel + 14

Installation and Commisioning 3.4 RM-PEM-N4 Connection Layout 4 3 2 1 1 pur Connection 1 2 pur Connection 2 3 pur Connection 3 4 pur Connection 4 Terminal Assignment hield connection - Channel - + Channel + 15

Installation and Commisioning 3.5 Grounding / hielding of Fieldbus Transmission Lines All shields of the Fieldbus transmission lines (trunks and spurs) are connected together inside the egment Protector, they have no connection to ground/din rail. Warning! Wrong Wiring Practice Connection of signal poles of the spur lines to the earth potential or the cable shield may cause major damage. Do not connect any signal poles of spur lines to earth potential or cable shield. O + I + TrunkIN/OUT RM-PTM-N2 4 + 3 + purs RM-PEM-N4 ERR4 4 3 + + purs RM-PEM-N4 ERR4 ERR3 ERR3 PWR PWR PWR COM ERR1 ERR1 ERR1 ERR2 ERR2 ERR2 purs 1 + 2 + purs 1 + 2 + purs 1 + 2 + Figure 3.1: tylized composition of the shield lines within the egment Protector If the shield of the trunk or of the spurs of a Fieldbus transmission line is grounded due to EMC considerations, the EN 60079-14 and the corresponding sections of the PROFIBU PA User and Installation Guideline, or of the FOUNDATION Fieldbus Application Guides, should be closely observed. 16

Installation and Commisioning 3.6 eries Connection and Termination The RM-PTM-N2 Trunk Module offers two Trunk connection terminals on the devices top side (Trunk in and Trunk out). This two connectors can be used to realize a series connection of several egment Protector groups by connecting the Trunk line from one Trunk Module to the next one. For good Termination practice a Fieldbus Terminator comes with each RM-PTM- N2 Trunk Module which fits into a free Trunk terminal (mostly on the last egment Protector within the row). M-FT Trunk Figure 3.2: tylized series connection and termination Note! As wrong termination may cause communication problems make sure that each trunk is terminated with exactly two Terminators. 17

Appendix 4 Appendix 4.1 Ordering Information Designation RM-PTM-N2 RM-PEM-N4 RM-BP M-FT Description Trunk Module Expansion Module Bus Connector Module, (packaging unit = 3 pieces) One RM-BP comes with each Trunk Module RM-PTM-N2 and Expansion Module RM-PEM-N4 Fieldbus Terminator M-FT, (packaging unit = 3 pieces) One Terminator comes with each Trunk Module RM-PTM-N2 4.2 Electromagnetic Compatibility Verification in Accordance with EC Council Legislation Directive 2004/108/EC Compatibility in accordance with EN61326-1:2006 and Namur NE21:2006 recommendation. The electromagnetic compatibility EMC requirements applicable for electrical equipment for measurement, control and laboratory use in general are anchored in the European tandard EN 61326. Three different performance criteria are distinguished in this standard: A category A device operates as intended during the test. This device can withstand the immunity tests without any noticeable performance degradations within the specification limits of the manufacturer. A category B device operates as intended after the test. The device shows temporary degradation or loss of function of performance during the test but selfrecovers from that state when the exposures are ceased. A category C device has loss of function, may need manual restoration. During the test a temporary loss of function is allowed as long as an operator can restore the device back to operation. The requirements of the association for standard and control and regulations of the German chemical industries, defined in the NE21 recommendation, are partly higher compared to the test levels and failure criteria defined in EN61326-1. For the product qualification, failure criteria and test levels have been selected, representing always the worst case conditions. EN61000-4, as a generic standard, defines the test setups for the specific required test for EN61326-1 and NE21. Applied standards: CE-Conformity 2004/108/EC EN61000-4, July 2007 EN61326-1, October 2006 EN55011, March 2007 NE21, Mai 2006 18

Appendix Conducted EMC tests: Immunity tandard Type Test Level Category EN 61000-4-2 EN 61000-4-3 EN 61000-4-4 EN 61000-4-5 EN 61000-4-6 EN 55011 Electrostatic discharge, direct contact Electrostatic discharge, indirect, air Electromagnetic field radiated, radio frequency Fast transients burst on signal lines Fast transients burst on power lines low transient surge on signal lines low transient surge on shielded lines Conducted immunity, radio frequency RF conducted emission RF radiated emission 6 kv A 8 kv A 10 V/m A 1 kv A 2 kv A 1 kv B 2 kv B 10 V A Class A _ Class A _ 4.3 Referenced Documents Manual: "Using Pepperl+Fuchs fieldbus equipment in Zone 2 hazardous area environment" 19

PROCE AUTOMATION PROTECTING YOUR PROCE Worldwide Headquarters Pepperl+Fuchs GmbH 68307 Mannheim Germany Tel. +49 621 776-0 E-mail: info@de.pepperl-fuchs.com For the Pepperl+Fuchs representative closest to you check www.pepperl-fuchs.com/pfcontact www.pepperl-fuchs.com ubject to modifications Copyright PEPPERL+FUCH Printed in Germany 200059 TDOCT-1215D_ENG 04/2010