E:COUNT LT MODEL MCR-09 SPECIFICATIONS & INSTALLATION REFERENCE

Similar documents
MID:COM THE ONE THAT WORKS!

MID:COM E:COUNT. Operators Reference Guide. Reference Guide for Operating the. MID:COM E:Count Electronic Register

INSTALLATION INSTRUCTIONS

PanelView Plus/VersaView CE Terminals and Display Modules

Scanner 2000 microefm QuickStart. Installing the Scanner Remote Mount. Direct Mount NUFLO. Part No , Rev. A

Vorne Industries. 2000S Series Serial Input Alphanumeric Display User's Manual

Installation and Operating Instructions

over time. Improper wiring practices could result in drive malfunction due to loose terminal connections. Control Circuit Terminal Block Functions Dri

Panel Indicators. NEW 4~20mA Panel Display. Process Indicators INTECH INSTRUMENTS.

CONTROL MICROSYSTEMS and 5407 Relay Output Module. Hardware Manual

SHPFI Smart Frequency to Current Converter & Pulse Scaler Installation and Operating Instructions

LAUREL. MAGNA Series Large Digit Displays for Counter / Totalizer Pulse Input ELECTRONICS, INC. Features. Description

12-36 VDC/12-24 VAC Power Option 4-Digit Display, 0.56 (14.2 mm) or 1.20 (30.5 mm)

Table of Contents 1 ABOUT THIS GUIDE CONTACT INFORMATION ANTENNA INSTALLATION... 4

Trident and Trident X2 Digital Process and Temperature Panel Meter

7511 / / / 711 / / 731 / Preset 27

CONTROL MICROSYSTEMS High Speed Counter Input Module. Hardware Manual

CONTROL MICROSYSTEMS Analog Output Module. Hardware Manual

485DRCI. Industrial RS-232 to RS-422/485 Converter PRODUCT INFORMATION B&B ELECTRONICS. Specifications Serial Technology

485DRCI. Industrial RS-232 to RS-422/485 Converter B&B ELECTRONICS PRODUCT INFORMATION. Specifications Serial Technology

PD765 TRIDENT. Trident Series Process & Temperature Meters.

OilCop Component Wiring Installation Manual

MTII4200 Level Transmitter Installation, Operation & Maintenance Instructions

Clamp-On Ultrasonic Flow- and Energy Meter For Liquids

CONTROL MICROSYSTEMS and 5402 Digital I/O Module. Hardware Manual

Differential Pressure ( P) Transducer US Patent

Level-Lance Model 5400A

CONTROL MICROSYSTEMS Differential Analog Input Module. Hardware Manual

CONTROL MICROSYSTEMS Analog Input Module. Hardware Manual

PD765 TRIDENT. Trident Series Process & Temperature Meters.

895/896M Frequency Output Math Modules

PACSystems* RX3i and Series IC693MDL940 / IC694MDL940

DIGITAL DISPLAY. for Industry Applications. Series WAY-SSI. Key-Features:

Output Signal Active Note DC V. Electrical Data Power Supply DC V, ±10%, 1.4 W

High Voltage DC Meter

CONTROL MICROSYSTEMS and 5404 Digital Input Module. Hardware Manual

LAUREL ELECTRONICS, INC.

SFY Functional Safety Frequency-to-DC Transmitter with Display

Installation, Operation

CONTROL MICROSYSTEMS Thermocouple Analog Input Module. Hardware Manual

User's Manual: Series 250T Potentiometer/Slidewire Input, Two-Wire Transmitters

SCADAPack Modbus multivariable transmitter

DINALOG A 144 x 36 A1400 Light-Strip Indicator

HIGH-VOLTAGE DC METER

Description. Green. Red. Orange

24/48/120 VAC Interface Card Instruction Manual

EP/2 Installation Instructions

This Datasheet for the IC697CHS790. Rack, 9 Slots, Rear Mount.

P522 Signal Processor

Rhino Buffer Module PSM24-BFM600S. Operating Instructions

H704-42(H)(E), H704-42/1(H)(E)

Y800 Plus Frequency, Rate & Period Meter With dual, independently field-scalable channels

Autoranging True RMS Multimeter User Manual

LAUREL ELECTRONICS, INC.

SINGLE-CHANNEL PROCESS CONTROLLERS & TEMP. DISPLAYS D3820/D3830 Series

MODEL SST3-MV INSTALLATION INSTRUCTIONS FOR FEDERAL MODEL SST3-MV SELECTABLE SIRENTONE-MULTI VOLT

Incremental encoders Solid shaft with clamping or synchro flange pulses per revolution

PowerLogic High Density Metering System 1-Meter Enclosure

Perle IDS-108F(XT) Unmanaged 10/100 Ethernet Switches. Installation Guide. P/N (Rev G)

MAXIMA + Series ROTARY LEVEL CONTROL

BMS BULK METERING SYSTEMS INSTALLATION GUIDE. PAGE 1 KrausGroup Inc. Bulk Metering Systems Installation Guide (236AY00.PRG R001)

6222 Two Door Module Technical Operations Manual

Installation Manual Rev D MiniProx Readers - Wiegand 5365B and Clock and Data 5368B

Installation and Operating Manual FM50 IOM 2-18 DRAFT

2 Table of Contents 1. TABLE OF CONTENTS. 1. Table of Contents Introduction Wiring Diagram Terminals Review...

NF770 Temperature Compensation Liquid Flow Computer

Programming and Installation Manual

Do not open when energized or when an explosive atmosphere is present. Electrostatic hazard, clean only with damp cloth.

Optical Encoders. Sold & Serviced By: Toll Free Phone: Toll Free Fax:

Carbon Monoxide Sensor - ModBus

DD1590 Series Proximity Driver. Connection Technology Center, Inc. Vibration Analysis Hardware. DD1590 Series. Proximity Probe Driver.

Installing Your 1394 Drive Interface Module

KOBOLD TDA Series Digital Temperature Transmitter

Scanner 2000 Steam Mass Flow Transmitter

Model 720 Electromechanical Hour Meter

Flow Meters. Model B Flow Monitor. Model B2800. Flow Monitor

OPERATING INSTRUCTION

MAXIMA+ Series Rotary Level Indicator

MegaTrak MCU-9000 Harness Wiring

RSTI-EP Slice I/O. PROFINET Scanner EPXPNS001. GFK-2965C November 2017

DUAL-LINE TEMPERATURE METER

MODBUS RTU I/O Expansion Modules - Models C267, C277, and C287. Installation and Operations Manual Section 50

PACSystems RX7i IC698CHS009/119

Universal Safety Photo Eye UL MONITORED DEVICE

Digital ac/dc (24V) Input Module

Honeywell Model 700/800 Signal Processor and Viewing Head

User's Guide. MiniTec TM Series Model MN25 MultiMeter

MAXIMA + Series ROTARY LEVEL CONTROL

Korry 1380 high-performance switch with oversized display for master caution and warning systems

OPERATING INSTRUCTIONS

Installation and Operation Manual. ETV Platinum Plus. Electronic Tempering Valve with Safeguard WARNING

S-14 S-14. Compact Digital Multimeter. Compact Digital Multimeter

RSTI-EP Slice I/O. EtherCAT Network Adapter Module EPXETC001. GFK-2967B Septembery 2016

DIGITAL DISPLAY. for Industry Applications. Series WAY-D. Key-Features:

Quick Start Guide MC-III TM Flow Analyzer

Adapter Kit - Remote QSI Electronics Installation Instructions

FieldLink process networking

Batch Controller with numerical keypad, remote control inputs and 3 control / alarm / pulse outputs

MODEL: R1M-P4. PC Recorders R1M Series. SPECIFICATIONS OF OPTION: Q COATING (For the detail, refer to M-System's web site.)

PLC Racks IC697CHS782/783

Transcription:

Mounting: The E:Count LT uses a four bolt (1/4-20) mounting pattern on the foot of the unit. If the unit is to be mounted directly to the flowmeter and uses the internal pulser the appropriate mounting flange adapter and drive shaft must be ordered for the particular model and size of meter. The adapter kits are provided with cross drilled seal bolts so that the unit can be Weights & Measures sealed after mounting. If the unit is to be remotely mounted from the meter and an external pulser used, no additional hardware is required besides the 4 bolts. Electrical Wiring: SUITABLE FOR USE IN CLASS 1, DIVISION 2, GROUPS C,D HAZARDOUS LOCATIONS OR NONHAZARDOUS LOCATIONS ONLY. WARNING EXPLOSION HAZARD DO NOT DISCONNECT EQUIPMENT WHILE THE CIRCUIT IS LIVE OR UNLESS THE AREA IS KNOWN TO BE FREE OF IGNITABLE CONCENTRATIONS. WARNING EXPLOSION HAZARD SUBSTITUTION OF ANY COMPONENT MAY IMPAIR SUITABILITY FOR CLASS 1, DIVISION 2. WARNING TO PREVENT IGNITION OF EXPLOSIVE ATMOSPHERES, DISCONNECT POWER BEFORE SERVICING. All wiring must be accordance with the National Electrical Code NFPA 70. In particular, if the unit is to be used in a Class 1, Division 2 hazardous location the installation and wiring must be in accordance with Article 500 of this publication. Wire size: (refer to Field Wiring Connector Designations) Power in, Ground, and Solenoid Connections (J1-1 to 2) (J9-1 to 6): All other connections: 18-16 AWG 22-18 AWG Terminal Blocks: The unit uses screw type terminal blocks that offer a good connection with vibration and temperature cycling. Prepare the wire by stripping off about.3 inches of insulation. Twist the strands tightly together. Make sure contact opening is clear, insert the wire and securely tighten the screw. Check for loose strands and pull on the wire to make sure of a good connection. Power Supply Fusing: A UL Listed JDYX fuse rated at 5A or less MUST be provided in the output of the DC power supply circuit. (Littlefuse series 233/234 or equivalent). Page 1 of 6

Power: J1-1 Power In... RED* J1-2 Power Ground In... BLACK* J1-3 Authorization Input J1-4 Ground J1-5 Auxiliary Input J1-6 Ground Safety Ground - Green Screw Adjacent To Hub... GREEN* Pulse Outputs: J13-1 Power Out (+12V DC) J13-2 Pulse Output 1... YELLOW* J13-3 Pulse Output 2 J13-4 Ground J11 Pulse Output 1 Pullup Resistor Jumper J12 Pulse Output 2 Pullup Resistor Jumper 470 Ω to +5 VDC 1 kω to +12 VDC No Jumper or Side Jumper (Default) Pull-up Resistor in FMS RS-232 Communication: RTD Probe: J2-1 TX Printer J2 - Compensator Board J2-2 RX Printer J2-3 Signal Ground Printer J2-4 TX Host J2-5 RX Host J2-6 Signal Ground Host External Encoder (pulser): Valve Outputs: J3-1 Channel B... WHITE* J9-1 Preset valve stage 1 J3-2 +5V DC Power Output RED* J9-2 Preset valve stage 2 J3-3 Channel A... GREEN* J9-3 Auxiliary valve/relay 1... GREY* J3-4 Signal ground... BLACK* J9-4 Auxiliary valve/relay 2... WHITE* J9-5 Ground... BLACK* J9-6 Ground... BLACK* * WIRE COLOR IF PREWIRED FROM FACTORY Page 2 of 6

Physical: Height: 6.00 + Shaft (~9/32 ) Width: 8.175 (8 3/16 ) Depth: 2.85 (3.85 including conduit hubs, possibly more for conduits) Weight: 3 pounds Mounting: Pulse drive: Housing: Bezel: Fasteners: 2.5 square pad with 1.5 Square ¼-20 bolt pattern mounts to MID:COM or user supplied adapter plates for any meter manufacturer. ½ slotted shaft. Receives MID:COM or user supplied cross-pinned tube shaft adapter for any meter. Case Aluminum with powder coat finish 0.125 thick with powder coat finish 303 or 316 Stainless Steel Keyboard/Display Lens: Display: Environmental: Outdoor Use Altitude: ENDURO membrane keyboard with LEXAN lens Supertwist black/white 6-digit 16 segment LCD, Alpha-numeric Backlit with High Brightness White LEDS Viewing angle +/- 60 degrees left/right, -10 + 80 degrees down/up High Contrast, readable in bright sunlight and total darkness. Up to 2000 M - 40º C to 60º C Temperature: Relative Humidity: 0-100% Enclosure: NEMA 4 Electrical: Typical Supply Voltage: Typical Supply Current: Maximum Load Current: Maximum Rated Control Output: Maximum Rated Signal I/O s: Pulse Input: Analog Input: Communication: External connections: Internal connections: 10-16 VDC Max <0.2 A (without optional solenoid valve/relay drivers active) 4.5 A (with solenoid/relay drivers active) 16 VDC, 3A, Pilot Duty 16 VDC, 6 ma 0-5 VDC 100 Ω Platinum RTD RS-232 ½ NPT listed conduit hubs Screw type terminal blocks Electrical Ratings: Temperature rating code: T4 For use in Class 1, Division 2, Hazardous Locations. Pulse Input: Internal: 256 PPR non-contact, non-optic, dual-channel quadrature output pulser. Pulser Manufacturer: MID:COM External: Dual or Single Channel Input Max Pulse Freq.: 5 khz Page 3 of 6

Inputs (2): Authorization Input: Auxiliary Input: J1-3, see below J1-5, Reserved for future use Authorization Input: The Authorization input disables the START/STOP from initiating a delivery and will end a delivery if one has been initiated. The Authorization input can be either HIGH (greater than 3 volts) or LOW (ground) depending on the HIGH or LOW selections under HWAUTH(or AUTHR) in the Setup menu. The factory default is HIGH so that no connection to this input allows an internal pull-up resistor to authorize the delivery at all times. This input uses a relay contact closure or an open-collector/drain output. Outputs (4): Output 1: Preset Stage 1: J9-1 Output 2: Preset Stage 2: J9-2 Output 3: Valve/Relay 1: J9-3, Energized at start of reset cycle Output 4: Valve/Relay 2: J9-4, Energized at end of reset cycle Software modifications available. Calibration: Automatic or Manual Entry Input Pulse Prescale: 1-99 (divides input stream) Calibration Range: 0.0000 to 1.9999 (1 part in 10,000) Temperature Compensator: (optional) Temperature Range: -40º - +63º C (-40º - +160º F) Temperature Probe Type: 100 Ω Platinum RTD Correction Method: API Table Lookup Correction Occurrence: Each 0.1 Increment in Registration Available API Tables: Approvals: UL, cul Control #3UJ9 NTEP COC 06-031 Count Capacity: Displayed: 99999 (6 digits) Printed: 99999999 (8 digits) Totalizer: 999999999999 (12 digits) Decimal: 1, 2, None Propane, Fuel Oil, Gasoline, Lube Oils, Methanol, JetA, JetB, Ethanol, NH3, Aviation Gasoline Printer Interface: Communications: Serial RS-232 Various models of impact and thermal printers, includes MID:COM, Epson, and others. External Communications: Parameters: 9600 Baud 8, 1, N Software Updates Field Programmable Page 4 of 6

LT & FUEL MANAGEMENT SYSTEM (FMS) WIRING Document No. MCR-09D Fuel Management Systems (also known as CardLocks, KeyLocks, etc.) have been available for a long time from a number of manufacturers. There are many different models that share some commonality but they can have distinct differences. It is beyond the scope of this document to describe how to connect to any specific device but instead this document will describe how the inputs and outputs of the LT work and show some examples of the hookup to different generic types of FMS inputs and outputs. In the simplest form the connections between the FMS and LT allow for the FMS to authorize the LT to start a delivery (and also end it if necessary) as well as allow the LT to send volume pulses to the FMS so that it can record the delivery. PULSE OUTPUT FROM LT The LT outputs one pulse for each increment of the right-hand digit of the display regardless of decimal position. For example, if there are 2 decimals on the display each pulse represents 0.01 units of volume (gallons or liters). If there is only one decimal then each pulse represents 0.1 units of volume. Typically dispensers use 2 decimals. As depicted in the figure below each pulse is in a "high" state for 5 ms. The pulse output is in a "low" state for a period of time determined by the flow rate but will not be less than 5 ms at maximum flow rate. The pulse output is configured as an "open collector" or "open drain" transistor with header J11 allowing for pull-up resistors to either +5 VDC or +12 VDC. The default from the factory is that the jumper is included but not installed. For this configuration to work properly the FMS must have its own pull-up resistor on the pulse input line or the installer may install one in the FMS from the pulse input line to the FMS DC power supply or one of the pullups in the LTIS may be used. It is very important not to have both a pull-up in the FMS and LT. To determine if the FMS does not have a pull-up resistor first visually look for one connected to the pulse input terminal and if none is found do a voltmeter check. With the meter set to DC Volts check between the pulse input line and the Common terminal (usually ground). If little or no voltage is seen then there is no pull-up resistor. Figure 1. PULSE OUTPUT PULL-UP RESISTOR AND TIMING DIAGRAM 470 Ω to +5 VDC 1 kω to +12 VDC No Jumper or Side Jumper (Default) Pull-up Resistor in FMS Pin 2 of J13 is the pulse line and Pin 4 (ground) is the return line for the pulse line and all other inputs and outputs. The "low" state voltage is less than 0.05 VDC under any conditions and typically near 0 VDC. The "high" state voltage depends on the J11 jumper placement and whether or not the FMS has a pull-up resistor on its pulse-input line. (continued) Page 5 of 6

PULSE OUTPUT FROM LT (continued) Document No. MCR-09D The return line (LT ground, J13 PIN 4) must be connected to the FMS return line. This line in the FMS may or may not be independent of the FMS power supply ground and is typically labeled "common or COM". The installer needs to determine what is the FMS signal return line and insure that it is connected to the minus side of the FMS DC power supply. It is important to note that return line connections can be the cause of serious signal degradation and electrical noise due to "Ground Loops". The LT logic and power ground is bonded to Earth ground. For solid operation it may be necessary to bond the FMS return line to Earth ground. Most FMS systems are compatible with old-style mechanical Reed Switch pulsers as well as electronic pulsers. Reed Switch pulsers exhibit "switch bounce" which the FMS has to filter out. The FMS will have a de-bounce feature that may be called "filter" or "high speed/low speed", etc. This is usually selectable with jumpers, dip-switches, or software settings. It is very important that the FMS be set for no filter, high speed, or "electronic" pulser; otherwise some or all of the pulses from the LTIS will be lost or filtered out. Page 6 of 6