See instructions to download and install the latest version of LinkBoxMB and the user's manual at

Similar documents
See instructions to download and install the latest version of LinkBoxMB and the user's manual at

See instructions to download and install the latest version of LinkBoxMB and the user's manual at

See instructions to download and install the latest version of LinkBoxMB and the user's manual at


See instructions to download and install the latest version of LinkBoxEIB and the user's manual at

See instructions to download and install the latest version of LinkBoxEIB and the user's manual at

See instructions to download and install the latest version of LinkBoxEIB and the user's manual at


See instructions to download and install the latest version of LinkBoxLON and the user's manual at

IntesisBox Modbus Server Panasonic

IntesisBox Modbus Server Fidelio IP

IntesisBox Modbus Server KILSEN KSA-7xx. User s Manual 08/2013 r1.2 eng

IntesisBox Modbus Server - Honeywell XLS 80

Modbus Server SIEMENS Algorex (printer port)

IntesisBox BACnet/IP Server DALI

IntesisBox KNX SAMSUNG NASA Air Conditioners

IntesisBox KNX - BACnet/IP Client

IntesisBox Modbus Server - BACnet/IP Client

IntesisBox Modbus Server KNX

IntesisBox Modbus Server LG Air Conditioning. User s Manual Issue Date: 06/2016 r1 eng

IntesisBox Modbus Server Siemens Synova FC330A

IBOX Modbus Server ESSER 8xxx/IQ8/FlexES fire panels

Modbus Server - M-Bus (EN ) Gateway for the integration of M-BUS meters with Modbus RTU and TCP based control systems.

---- IntesisBox KNX Modbus RTU Master and Modbus TCP Client

Gateway for integration of Modbus RTU slave devices into BACnet IP based systems.

IntesisBox BACnet IP Server - M-Bus

IntesisBox Modbus Server M-Bus

Modbus Server - Mitsubishi Electric G50

IntesisBox Modbus Server - LON

ASCII Server - BACnet/IP Client. Gateway for integration of BACnet IP devices into ASCII enabled control systems.

Modbus Server - Mitsubishi Electric G50

8-Port IP40 IEEE802.3af PoE Unmanaged Industrial Switch User s Manual

IntesisBox KNX - BACnet/IP Client

Modbus Server - Mitsubishi Electric G50

IntesisBox KNX - AIRZONE

IntesisBox ME-AC-BAC-1

IntesisBox BACnet/IP Server Modbus RTU Master

IntesisBox BACnet/IP Server Modbus TCP Master

IntesisBox. KNX - Mitsubishi Electric G50. Gateway for integration of Mitsubishi Electric City Multi air conditioners into KNX control systems.

DKG-210 UNIVERSAL INTERNET GATEWAY UNIT

IntesisBox BACnet/IP Server M-Bus meters

IntesisBox ASCII Server - KNX

IntesisBox KNX - Mitsubishi Electric G50

F1000 User's Manual. (Version: V1.01)

IntesisBox LON - KNX

IntesisBox Modbus Server BACnet MSTP and BACnet/IP client

Mid-span 802.3af PoE Injector. Installation Guide KPOE-100

IntesisBox Modbus Server Mitsubishi Electric Centralized Controller TCP/IP XML. User Manual Issue Date: 01/2018 r1.0 EN

OTB1E0DM9LP I/O distributed module OTB - Ethernet TCP/IP m

OTB1E0DM9LP I/O distributed module OTB - Ethernet TCP/IP m

Fieldgate SFG500. Technical Information. Intelligent Ethernet/PROFIBUS gateway

RAD-DO8-IFS. I/O extension module, eight digital transistor outputs. Data sheet. 1 Description

INSTRUCTION MANUAL. Universal AC Input Switching Power Supply 24 Vdc Output DIN-Rail Models PSD1000, PSD1000F PSD PSD1000F

4 10/100/1000T Mini-GBIC with 4 IEEE 802.3at High Power PoE Industrial Wide Temperature Switch. User Manual SISTP LRT

IntesisBox. v.0.1. User Manual Issue Date: 12/2017 r1.3 EN

Hypercable injecteur HPOE - Industrial IEEE 802.3at Gigabit PoE Injector. User Manual. v.1.0 Jun Mail :

DIRIS Digiware D and C Communication and control power interfaces

Lantech. IPES /100TX with 4 PoE Injectors 24~48VDC Industrial Switch. User Manual

Hardened Ethernet to VDSL2 Extender. User Guide. Revision History. Industrial Ethernet to VDSL2 Extender with Wide Operating Temp. Rev.1.

D6030S - D6030D INSTRUCTION MANUAL. D SIL 3 Switch/Proximity Detector Repeater Relay Output. Models D6030S, D6030D

RAD-DI8-IFS. I/O extension module with 8 digital inputs or 2 pulse inputs. INTERFACE Data sheet. 1 Description

TCNM-ACBB1 Installation Manual

Rhino Redundancy Module PSM24-REM360S. Operating Instructions

Rhino Buffer Module PSM24-BFM600S. Operating Instructions

RAD-DOR4-IFS. I/O extension module, 4 digital relay outputs. INTERFACE Data sheet. 1 Description

8 10/100/1000T Industrial Switch. User Manual MS655208(X)

4-port 10/100TX + 1 or 2-port 100FX Industrial Switch. User Manual

IntesisBox Modbus Server BACnet/IP Client

IntesisBox PA-AW-MBS-1 v.2.0

Industrial 5-Port Fast Ethernet Switches with SFP Slot and optional 4 PoE PSE Ports. Basic Model: KSD-541 PoE Model: KSD-541-P. Installation Guide

Industrial 5-Port Fast Ethernet Switches. with SFP Slot and optional 4 PoE PSE Ports. Basic Model: KSD-541. PoE Model: KSD-541-HP. Installation Guide

SATEL-LP-AI4. I/O extension module, 4 analog current inputs. Data sheet. 1 Description

KFC-200. Installation Guide

Industrial Ethernet Switch

OTB1E0DM9LP I/O distributed module OTB - Ethernet TCP/IP m

16- or 24-port Managed Switching Hubs

User Manual Entry Line Industrial Gigabit Ethernet High Power 60/95 W PoE Injector

MVS RAIL ELECTRONIC FAN SPEED CONTROLLER. Mounting and operating instructions

Installation manual for for Schleifenbauer DPM3

XPSMF35. Product data sheet Characteristics. Preventa safety PLC compact - Profibus DP protocol. Main. Complementary. Safety module name

ProData DATA LOGGER. Chapter 03 ProData data logger. Ethernet. Pulse inputs and Pulse outputs. Modbus-Ethernet gateway. Thermistor input.

MC 11 EB-2 Power supply cabinet with external bus, AC version

XPSMCMCO0000EM Modbus TCPIP diagnostic expansion module with screw term

CLIMATIX STEQ, STCM DATASHEET FOR CONTROLLING, SWITCHING AND MONITORING FUNCTIONS. POWER SUPPLY RELAY OUTPUTS. Power supply. 4.

DPOM8-24/20 DIN RAIL POWER OVER MODBUS MODULE. Mounting and operating instructions

IntesisBox SMS - Mitsubishi Electric air conditioners

RXTH DUAL ROOM SENSOR / SWITCH

RST ROOM TEMPERATURE TRANSMITTER. Mounting and operating instructions

RXTP ROOM TEMPERATURE

KSD-800 Series. Installation Guide. Industrial 8-Port Fast Ethernet Switches with Fiber Connectivity DOC A -1-

Artistic Licence. Rail-Demux. User Guide. Rail-Demux User Guide. Version 2-7

IEC-0101FT Industrial 10/100TX to 100M-FX Slim Type Converter User Manual

XPSMF40. Main. Safety module name. Monitoring safety detection discrete input Monitoring safety dialogue discrete output

User Manual. MS657140X Industrial Fast Ethernet Switch 8x 10/100Base-TX

XBR V4 INSTALLATION AND USER GUIDE

CoolPlug CooLinkHub HVAC Bridge. Quick Installation Guide

G.SHDSL NTU with Fixed Serial Interfaces

INSTRUCTION MANUAL. SIL 3 Relay Output Module DIN-Rail Models D1092S-069, D1092D-069 D1092S D1092D-069

CoolPlug CooLinkHub HVAC Bridge. Quick Installation Guide

ProData data logger. Ethernet. Pulse inputs and Pulse outputs. Thermistor input. Modbus-Ethernet gateway. Memory 32 MB. Threshold value monitoring

Transcription:

Safety Instructions WARNING Follow carefully this safety and installation instructions. Improper work may lead to serious harmful for your health and also may damage seriously the IntesisBox and/or any other equipment connected to it. IntesisBox must be installed by accredited electrician or similar technical personnel, following all the safety instructions given here, and in accordance always with the country legislation for installation of electric equipment. IntesisBox can not be installed outdoors or exposed to direct solar radiation, water, high relative humidity or dust. IntesisBox must only be installed in a restricted access location In case of wall mount, fix firmly IntesisBox on a not vibrating surface following the instructions below. In case of DIN rail mount fix IntesisBox properly to the DIN rail following the instructions below. Mounting on DIN rail inside a metallic cabinet properly connected to earth is recommended. Disconnect always power of any wires before manipulating and connecting them to IntesisBox. A power supply with a NEC Class 2 or Limited Source (LPS) and SELV rated is to be used. Respect always the expected polarity of power and communication cables when connecting them to IntesisBox. Supply always a correct voltage to power IntesisBox, see details of voltage range admitted by the device in the technical characteristics below. This device was designed for installation in an enclosure. To avoid electrostatic discharge to the unit in environments with static levels above 4 kv precautions should be taken when the device is mounted outside an enclosure. When working in an enclosure (ex. making adjustments, setting switches etc.) typical anti-static precautions should be observed before touching the unit Installation instructions Disconnect from mains the power supply before connecting it to IntesisBox. Disconnect power of any bus or communication cable before connecting it to IntesisBox. Mount IntesisBox on the wall or DIN rail following the instruction given below, respecting the safety instructions given above. Connect a NEC Class 2 or Limited Source (LPS) and SELV rated power supply to IntesisBox, respect the polarity if DC power or Line and Neutral if AC power. Apply always a voltage within the range admitted by IntesisBox and of enough power (see technical characteristics). Circuit-breaker must be used before the power supply. Rating 250V-6A Connect the communication cables to IntesisBox, see details on the user's manual. IntesisBox and the rest of devices connected to it. Configuration and setup Use the software LinkBoxMB to configure IntesisBox, follow the instructions of the user's manual for more details. See instructions to download and install the latest version of LinkBoxMB and the user's manual at /down/mb/linkboxmb.html 1 / 5

Wall mount 1. Separate the fixing clips in the bottom of the box, pushing them to the outside until hear the "click" which indicates that now the clips are in position for wall mount, see in the figure below. Botton view of the box Clips in their original position, for DIN rail mount Clips in position for wall mount 2. Use the holes of the clips to fix the box in the wall with screws. Use the template below for the wall holes. 61 mm Ø 3 mm Top view of the box IntesisBox www.intesis.com 100 mm DIN rail mount With the clips of the box in their original position, insert first the box in the upper edge of the DIN rail and later insert the box in the down part of the rail using a small screwdriver and following the steps in the figure below. Side view of the box 1 DIN Rail 3 2 2 / 5

Connections Modbus TCP See Note 1 Notifier Panel See Note 3 Ethernet RJ45 - + CMN 24Vac 9-30Vdc Max.125 ma 24Vac Max.127mA 50-60Hz Ethernet Modbus TCP IntesisBox www.intesis.com Notifier ID3000 EIA485 EIA485 - + PC Console LinkBoxMB Only for configuration See Note 4 Console cable 1.8 m. DB9 Female - DB9 Male standard. Supplied. Notes: 1. Must use NEC Class 2 or Limited Source (LPS) and SELV rated power supply. If using DC power supply: Respect polarity applied of terminals (+) and (-). Be sure the voltage applied is within the range admitted (9 to 30 Vdc). The power supply can be connected to earth but only through the negative terminal, never through the positive terminal. If using AC power supply: Make sure the voltage applied is of the value admitted (24 Vac). Do not connect any of the terminals of the AC power supply to earth, and make sure the same power supply is not supplying any other device. 2. Modbus connection. Only one type of modbus connection can be used simultaneously, Modbus TCP, EIA485, or, the type of Modbus connection to use must be selected within the configuration software LinkBoxMB. Modbus TCP connection: This connection with the Modbus TCP master device can be done directly using a ethernet CAT5 crossover cable, or through the LAN of the building, in this case use a ethernet CAT5 straigh cable to connect to a switch or hub of the LAN, check with the network administrator that the TCP traffic and the port used (502 by default) are allowed through all the LAN path used. EIA485 connection: Connect the EIA485 bus to the connector EIA485 of IntesisBox. Respect the polarity. Remember the characteristics of the standard EIA485 bus: maximum distance of 1200 meters, maximum 32 devices connected to the bus, and in each end of the bus it must be a termination resistor of 120 ohms. IntesisBox has an internal bus biasing circuit that incorporates the termination resistor, if you install IntesisBox in one of the ends of the bus then do not install an additional termination resistor in that end. connection: Connect the serial cable coming from the master to the connector Modbus RTU of IntesisBox, this is a DB9 male (DTE) connector in which only the lines TX, RX and GND are used, see details of the pinout in the user's manual. Respect the maximum distance of 15 meters in this serial line. 3. Connection with the Notifier panel: Connect the serial cable coming from the Notifier panel to the connector Notifier ID3000 of IntesisBox, this is a DB9 male (DTE) connector in which only the lines TX, RX and GND are used. In the Notifier panel, it can be connected either to the connector of the main board or to the additional ISO- board, see details of this connection in the user's manual. Respect the maximum distance of 15 meters in this serial line. 4. Use the software LinkBoxMB to configure IntesisBox. See the user's manual for details. 3 / 5

Technical characteristics Plastic, type PC (UL 94 V-0). Enclosure Dimensions: 107mm x 105mm x 58mm. Colour Light Grey. RAL 7035. 9 to 30Vdc +/-10%, Max.: 125mA. 24Vac +/-10% 50-60Hz, Max.: 127mA Must use a NEC Class 2 or Limited Source (LPS) and SELV rated power supply. Plug-in terminal block for power connection (2 poles). Terminal wiring (for power supply and low-voltage signals) Mounting Modbus TCP port ports Notifier port LED indicators Per terminal: solid wires or stranded wires (twisted or with ferrule) 1 core: 0.5mm 2 2.5mm 2 2 cores: 0.5mm 2 1.5mm 2 3 cores: not permitted Wall. DIN rail EN60715 TH35. 1 x Ethernet 10Base-T RJ45. 1 x. DB9 male connector (DTE). SELV 1 x EIA485. Plug-in terminal bloc (2 poles). SELV 1 x. DB9 male connector (DTE). SELV 1 x. 2 x Notifier port activity (Tx, Rx). 2 x port activity (Tx, Rx). 2 x Ethernet port link and activity (LNK, ACT). Console port. DB9 female connector (DCE). SELV Configuration Via console port. 1 Firmware Operational temperature Operational humidity Protection RoHS compliance Norms and standards Allows upgrades via console port. 0 C to +70 C 5% to 95%, non condensing IP20 (IEC60529). Compliant with RoHS directive (2002/95/CE). CE conformity to EMC directive (2004/108/EC) and Low-voltage directive (2006/95/EC) EN 61000-6-2 EN 61000-6-3 EN 60950-1 EN 50491-3 1 Standard cable DB9male-DB9female 1,8 meters long is supplied with the device for connection to a PC COM port for configuring and monitoring the device. The configuration software, compatible with Windows operating systems, is also supplied. 4 / 5

Dimensions External dimensions. + Ethernet port Notifier port 58 mm ports Console port 107 mm 105 mm Free space recommended to install the device, with spacing enough for external connections. 100 mm 115 mm 130 mm 5 / 5