Float Switches with Permanent Magnet For Vertical Installation Model RSM

Similar documents
Float Switches with Permanent Magnet For Horizontal Installation Model HIF

Magnetic float switch For vertical installation Model FLS

Float switch For the process industry

Float switch For the process industry, lateral installation with external chamber Model ELS

Level sensor Magnetostrictive, high-resolution measuring principle Models FFG-P, FFG-T, FFG-TP, FLM-H

Level sensor with reed measuring chain Model FLR, for the process industry

Float switch For industrial applications Model RLS-1000

Level sensor for monitoring the level of liquid media

Level sensor Stainless steel version Model RLT-1000, for industrial applications

Reed sensor For bypass level indicators Model BLR

Level measurement. Applications. Special features. Description

Gas-actuated thermometer Stainless steel version Model 73

Thermocouples Model TC200, for Additional Thermowell

Resistance thermometer With spring-loaded tip Model TR55

Threaded resistance thermometer Miniature design Model TR10-D

Threaded thermocouple Miniature design Model TC10-D

LS 5000 series Vibration Level Switch for liquids

Magnetic field sensor Magnetic-inductive Proximity Sensor BIM-M12E-Y1X

Electronic pressure switch with display For sanitary applications Model PSA-31

Application The DA03 serves as indicator of differential. Follow mounting instructions in accordance to application.

Magnetic Field Sensor Magnetic-inductive Proximity Sensor BIM-EG08-Y1X

NIVOSWITCH VIBRATING FORK LEVEL SWITCHES

Level gauges Series LS Level indicator, switch and transmitter for liquids

Bourdon tube pressure gauge with electrical output signal Stainless steel, safety version, NS 63 Model PGT23.063

Electronic pressure switch with display For sanitary applications Model PSA-31

LMP 308. Separable Stainless Steel Probe. Stainless Steel Sensor. accuracy according to IEC 60770: standard: 0.35 % FSO option: 0.25 % FSO / 0.

Miniaturised pressure sensor Model M-10, standard version Model M-11, version with flush diaphragm

Inductive sensor BI5-EM18-Y1X-H1141

Level Transmitter. Table of dimensions see page 4. Total length B Installation length A SW55 Ø 55 Ø 75

Adapter system for measuring instruments with G1 hygienic connection Model process adapter

Precision digital pressure gauge Model CPG1500

Electronic pressure switch with display Model PSD-4

Inductive sensor NI3-EG08K-Y1-H1341

ProcessCalibrator Model CPH6000

Magnetic Field Sensor Magnetic-inductive Proximity Sensor BIM-M12E-Y1X-H1141

Dual differential pressure sensor For ventilation and air-conditioning Model A2G-52

FOR LIQUIDS AND SOLIDS

Pressure sensor For highest pressure applications to 15,000 bar Model HP-2

General Specifications

Micro calibration bath Models CTB , CTB

Magnetic Field Sensor Magnetic-inductive Proximity Sensor BIM-EG08-Y1X-H1341

General Specifications

Threaded resistance thermometer Model TR10-C, with protection tube

Threaded resistance thermometer With protection tube Model TR10-C

Inductive sensor BI1.5-EG08-Y1-H1341

Resistance thermometer For additional thermowell Model TR10-B

Bayonet resistance thermometer Model TR53

Capacitance level switches LS 210 LS 220

Inductive sensor Dual sensors with extended temperature range NI4-DSU35TC-2Y1X2/S97

Differential pressure sensor For ventilation and air-conditioning Model A2G-50

5 Fieldbus Technology

Operating Instructions

Vane wheel probe BFA25 for flow measurement of gases and liquids with integrated, configurable transducer UFA in Ex-d housing

Inductive sensor BI1.5-EG08-Y1-H1341

LMP 307. Stainless Steel Probe. Stainless Steel Sensor. accuracy according to IEC 60770: standard: 0.35 % FSO option: 0.25 % / 0.

DS 201P. Electronic Pressure Switch. Pressure Port With Flush Welded Stainless Steel Diaphragm. accuracy according to IEC 60770: 0.

PI-EX-ME-2NAM/COC-24VDC

Indication and Adjustment Product Information VEGADIS 61. Level Switching Pressure

97100 NAMUR series, 3/2 & 5/2 Indirect solenoid actuated spool valve

Standard reference resistor Model CER6000

Inductive sensor with analog output BI15-M30-LI-EXI

LMP 308i. Separable Stainless Steel Probe Precision. Stainless Steel Sensor. accuracy according to IEC 60770: 0.1 % FSO

PI-EX-ME-2NAM/COC-120VAC

Precision thermometer Model CTR5000

Pressure transmitter for highest pressure applications Up to 217,500 psi (15,000 bar) Model HP-2

Inductive dual sensor For rotary actuators NI4-DSU35TC-2Y1X2/S933

standard, short, preferential, top

Precision hand-held pressure indicator Model CPH6400

LMP 308i. Separable Stainless Steel Probe Precision. Stainless Steel Sensor. accuracy according to IEC 60770: 0.1 % FSO.

Electronic pressure switch with display For sanitary applications Model PSA-31

CombiTemp TFRN/TFRH. Operating instructions. Temperature sensor. Operating Instructions: EN.

Safety instructions VEGATOR 121, 122

Operating Instructions. Intrinsically Safe Isolation Relay for Switches Model: REL manual_rel-6_0505

Inductive sensor For rotary actuators NI4-DSU35TC-2Y1X2

Series DiTemp Series SolarTemp. Digital Thermometers

Inductive sensor For rotary actuators NI4-DSU35TC-2Y1X2/S933

M E M O R A N D U M I.S.

SYSTEM COMPONENTS SYSTEM COMPONENTS MODULES

97105 NAMUR. Technical data. Ordering information and accessories See page 6 and 7

Separating and protective. Separating and protective instruments. VEGATRENN 149AEx Separator type KFDO Barrier type Product Information

Float Flow Meter. Flow measurement for translucent liquids and gases DN10 to DN65 mm. Technical data Orifice DN 10 to 65

TFR5. Room or outdoor temperature sensor. Operating instructions for temperature sensor. English page 1...5

Indicating Digital Transmitter for Differential Pressure and Flow. Media 6 with LCD Media 6 with LED

Flow Measurement SITRANS F M. Transmitter MAG 6000 I/6000 I Ex de. 3/46 Siemens FI

Electronic pressure switch with display Model PSD-30, standard version Model PSD-31, with flush diaphragm

Hand-held thermometer, precision version Model CTH6500 Model CTH65I0, Ex version

Variable Area Flowmeter DATASHEET

Hand-held thermometer, industrial version Model CTH6300 Model CTH63I0, Ex version

Programming unit VIATOR HART modems Model PU-H

Temperature dry-well calibrator Models CTD , CTD

Inductive sensor For rotary actuators NI4-DSU35-2Y1X2-H1140

DMP 333 DMP 333. Industrial Pressure Transmitter For High Pressure. Stainless Steel Sensor. Pressure Transmitter. Industrial

selection of special materials is available to handle almost any fluid.

PHOENIX CONTACT - 12/2007

Precision digital pressure gauge Model CPG1500

HERION SERIES Indirect solenoid actuated spool valves

Portable Multi-Function Calibrator Model CEP6000

Pneumatic Control/Feedback

Pneumatic Control/Feedback

Linear Luminaire with LED Series EXLUX 6002/1 Version IIB+H2

Transcription:

Level Measurement Float Switches with Permanent Magnet For Vertical Installation Model RSM WIKA Data Sheet LM 30.01 Applications Level measurement for almost all liquid media Pump/level control and monitoring for defined filling levels Chemical industry, petrochemical industry, natural gas, offshore, shipbuilding, machine building, power generating equipment, power stations Process water and drinking water treatment, food and beverage industry Special Features Large scope of application due to the simple, proven functional principle For harsh operating conditions, long service life Operating limits: - Operating temperature: T = -196... +300 C - Working pressure: P = vacuum to 100 bar - Limit S. G.: ρ 400 kg/m 3 Wide variety of different electrical connections, process connections and materials Explosion-protected versions Description A float with a permanent magnet moves reliably along with the liquid level on a guide tube. Within the guide tube is fitted a reed contact (inert gas contact), which is energised, through the non-magnetic walls of the float and guide tube, by the approach of the float magnet. By using a magnet and reed contact the switching operation is non-contact, free from wear and needs no power supply. The contacts are potential-free. WIKA float switches with permanent magnets are also available with several switch points. Float Switches with Permanent Magnet, for vertical installation, Model RSM Fig. left: Stainless steel version, mounting thread Fig. right: Plastic version, flange connection The switch functions always refer to a rising liquid level: normally open / normally closed / change-over contacts. Through the use of a float for a max. of switch points a bistable switch operation can be achieved, meaning that the switching status also remains available, when the filling level continues to rise above or drop below the switch point. The float switch is simple to mount and maintenance-free, so the costs of mounting, coissioning and operation are low. WIKA Data Sheet LM 30.01 01/010 Page 1 of 14 Data Sheets showing similar devices: Float Switches with Permanent Magnet, horizontal installation; Model HIF; see data sheet LM 30.0 Float Switches with Permanent Magnet, lateral mounting; Model RSB; see data sheet LM 30.03

Further special features Process connection, guide tube material and float made of stainless steel 1.4571 or plastic Universal signal processing: connection direct to a PLC is possible, NAMUR connection, signal amplification / contact protection relays Works independently of foaming, conductivity, dielectricity, pressure, vacuum, temperature, steam, condensation, blistering, boiling effects and vibrations Multiple functionality in a single instrument - up to 8 potential-free contacts Exact repeatability of the switch points Float switches with permanent magnets qualify as passive electrical equipment in accordance with DIN IEC 60 079-11 and can be installed in 'Zone 1' hazardous areas without certification, so long as the equipment is operated in a certified intrinsically safe circuit with a minimum explosion protection of EEx ib Options Customer-specific solutions Specific designs for interface layer detection -ρ 50 kg / m 3 Process connection, guide tube material and float made of stainless steel 1.4435, 1.4539, titanium, Hastelloy (others on request) Page of 14 WIKA Data Sheet LM 30.01 01/010

Application examples Level switch (EEx i) Intrinsically safe Intrinsically safe Intrinsically safe relay e.g.: KR 4 Ex Intrinsically safe relay e.g.: KR 4 Ex Ex zone non Ex zone Ex zone non Ex zone Level control (min.-max. control) Contact protection relay e.g.: KR 30 Contact protection relay e.g.: KR 4 Product prograe Selection of process connection, material and design further information on the indicated pages. Process connection Material Explosion-protected Material Stainless steel version PVC / PP / PVDF (without terminal box) G 1/8"... G " Page 4 Page 5 (adjustable guide tube) Page 7 (Mini float) - Page 8 G 1/"... G " Page 4 Page 5 (adjustable guide tube) Page 7 (Mini float) Page 6 Page 8 Flange DN 50... DN 00 PN 6... PN 100 Page 4 Page 5 (adjustable guide tube) Page 9 (E-CTFE coated) Page 6 Page 8 Float versions: page 10 and 11 Contact protection measures: page 1 Connection diagrams: page 13 and 14 WIKA Data Sheet LM 30.01 01/010 Page 3 of 14

Standard version Process connection, guide tube material and float made of stainless steel 1.4571 Connection cable (without terminal box) Flange Electrical connection Process connection Connection cable PVC grey PVC blue Silicone PUR upwards G 3/8" (others on request) G 1/" (others on request) downwards G 1 1/" or G " Aluminium 64 x 58 x 34, with 1 contact Aluminium 80 x 75 x 57, or more contacts Option: Polypropylene, polyester, stainless steel Mounting flange DIN DN 50... DN 00, PN 6... PN 100 ANSI "... 8", Class 150... 600 Guide tube diameter 1 or 14 18 1 or 14 18 1 or 14 18 Guide tube length L max. 3000 6000 3000 6000 3000 6000 Float Temperature range standard Material stainless steel 1.4571 (Option: Buna, titanium) Float diameter from 44... 10 Float selection depending on guide tube diameter and process conditions (see page 10 and 11) PVC / PUR cable -10... +80 C Silicone cable -30... +150 C -30... +150 C Option: High temperature version: +150... +300 C Option: Low temperature version: -196... -30 C Switch function Max. number of contacts Switch position Distance between switch points Optionally contact makes S, contact breaks O or change-over U - at increasing level PVC cable 6 x S or O, or 4 x U Silicone cable 5 x S or O, or 3 x U 6 x S or O, or 4 x U Dimensions L 1, L, L 3... (from sealing face, starting from top) Minimum 0 (depending on the selection of the float and the contacts, see page 10 and 11) Contact rating Contact makes 30 V AC; 100 VA; 1 A 30 V DC; 50 W; 0.5 A Contact breaks 30 V AC; 100 VA; 1 A 30 V DC; 50 W; 0.5 A Please observe contact protection measures (see page 1)! Change-over 30 V AC; 40 VA; 1 A 30 V DC; 0 W; 0.5 A Mounting position Vertical ± 30 Attention: Versions without protective earth conductor - operation only at safety extra-low voltage e.g. WIKA contact protection relay or external earthing Ingress protection IP 65 per EN 60 59 / lec 59 Page 4 of 14 WIKA Data Sheet LM 30.01 01/010

Version with adjustable guide tube Process connection, guide tube material and float made of stainless steel 1.4571 guide tube adjustable by loosening union nut Connection cable 7 flats guide tube adjustable by loosening union nut 7 flats guide tube adjustable by loosening union nut 7 flats 14 G 1/" (without terminal box) Flange Electrical connection Process connection Guide tube diameter Guide tube length L max. Float Nominal pressure Temperature range standard Switch function Max. number of contacts Switch position Distance between switch points Connection cable PVC grey PVC blue Silicone PUR upwards G 1/" (others on request) 1 3000 Aluminium 64 x 58 x 34, with 1 contact Aluminium 80 x 75 x 57, or more contacts Option: Polypropylene, polyester, stainless steel downwards G 1 1/" or G " (others on request) Material stainless steel 1.4571 (Option: Buna, titanium) Float diameter from 44... 83 Float selection depending on guide tube diameter and process conditions (see page 10 and 11) 5 bar PVC / PUR cable -10... +80 C Silicone cable -30... +150 C -30... +150 C Optionally contact makes S, contact breaks O or change-over U - at increasing level PVC cable 6 x S or O, or 4 x U Silicone cable 5 x S or O, or 3 x U 6 x S or O, resp. 4 x U Dimensions L 1, L, L 3... (from sealing face, starting from top) Minimum 0 (depending on the selection of the float and the contacts, see page 10 and 11) Mounting flange DIN DN 50... DN 00, PN 6... PN 100 ANSI "... 8", Class 150... 600 Contact rating Contact makes 30 V AC; 100 VA; 1 A 30 V DC; 50 W; 0.5 A Contact breaks 30 V AC; 100 VA; 1 A 30 V DC; 50 W; 0.5 A Please observe contact protection measures (see page 1)! Change-over 30 V AC; 40 VA; 1 A 30 V DC; 0 W; 0.5 A Mounting position Vertical ± 30 Attention: Versions without protective earth conductor - operation only at safety extra-low voltage e.g. WIKA contact protection relay or external earthing Ingress protection IP 54 per EN 60 59 / lec 59 IP 65 per EN 60 59 / lec 59 WIKA Data Sheet LM 30.01 01/010 Page 5 of 14

Explosion-protected version, intrinsically safe II 1/G EEx ia IIC T3-T6 KEMA 09 ATEX 018X II D T80 C IP6X Process connection, guide tube material and float made of stainless steel 1.4571 X X Process temperature Raised terminal box X < 60 C 0 < 135 C 60 < 180 C 80 Flange Electrical connection Aluminium 80 x 75 x 57 Option: Polyester, stainless steel Process connection downwards G 1 1/" or G " (others on request) Mounting flange DIN DN 50... DN 150, PN 6... PN 64 ANSI "... 6", Class 150... 600 Guide tube diameter 1 or 14 18 1 or 14 18 Guide tube length L max. 3000 6000 3000 6000 Float Temperature class Process temperature Ambient temperature at terminal box Material stainless steel 1.4571 (Option: Buna, titanium) Float diameter from 44... 10 Float selection depending on guide tube diameter and process conditions (see page 10 and 11) T3 T4 T5 T6 Max. 180 C 130 C 95 C 80 C Max. 60 C 60 C 60 C 60 C Switch function Max. number of contacts Switch position Distance between switch points Contact rating Optionally contact makes S, contact breaks O or change-over U - at increasing level 6 x S or O, or 4 x U Dimensions L 1, L, L 3... (from sealing face, starting from top) Minimum 0 (depending on the selection of the float and the contacts, see page 10 and 11) Only for connection to a certified intrinsically safe circuit with U max 36 V, I max 100 ma Mounting position Vertical ± 30 Ingress protection IP 65 per EN 60 59 / lec 59 Options Temperature resistance Pt100 or Pt1000 Bimetal thermal contact 40... 10 C (in 5 degree steps) Page 6 of 14 WIKA Data Sheet LM 30.01 01/010

Mini float version Process connection and guide tube material made of stainless steel 1.4571 Coupler connector ASC4 M1 x 1 Connection cable 1 G 1/8" 7 flats (without terminal box) Electrical connection Connection cable PVC grey PVC blue Silicone PUR Aluminium 64 x 58 x 34 Coupler connector ASC4, C 164-3-F-4P Coupler connector M1 x 1 Process connection upwards G 1/8" (others on request) downwards oder G 1" (others on request) Guide tube diameter 8 Guide tube length L max. 500 Float Temperature range Switch function Max. number of contacts Material stainless steel 1.4571 (Option: Buna, polypropylene, titanium) Float diameter from 3... 9 Float selection depending on guide tube diameter and process conditions (see page 10 and 11) -10... +100 C (Float material stainless steel or titanium) -10... +80 C (Float material Buna or polypropylene) Optionally contact makes S, contact breaks O or change over U - at increasing level 3 x S or O, or 1 x U Contact rating Contact makes 50 V AC; 10 VA; 0.5 A 50 V DC; 5 W; 0.5 A Contact breaks 50 V AC; 10 VA; 0.5 A 50 V DC; 5 W; 0.5 A Please observe contact protection measures (see page 1)! Change-over 8 V AC; 6 VA; 0.6 A 8 V DC; 3 W; 0.3 A Mounting position Vertical ± 30 Attention: Versions without protective earth conductor - operation only at safety extra-low voltage e.g. WIKA contact protection relay or external earthing Ingress protection IP 54 per EN 60 59 / lec 59 IP 65 per EN 60 59 / lec 59 WIKA Data Sheet LM 30.01 01/010 Page 7 of 14

Plastic version Process connection, guide tube material and float made of PVC, polypropylene or PVDF Guide tube Ø 1 Connection cable 1 G 3/8" flats M0 x 1.5 M0 x 1.5 Guide tube Ø 16 Connection cable 14 G 1/" 7 flats Guide tube Ø 0 Connection cable 4 G 1" 3 flats (without terminal box) Flange Electrical connection Process connection Guide tube diameter Guide tube length L max. Connection cable PVC grey PVC blue PUR, upwards G 3/8" (Guide tube Ø 1 ) G 1/" (Guide tube Ø 16 ) G 1" (Guide tube Ø 0 ) (others on request) Polypropylene 80 x 8 x 55, downwards G 1 1/" or G " (others on request) 1, 16 or 0 (16 and 0 : strengthened with a metallic inner tube) 500 (Guide tube Ø 1 ) 3000 (Guide tube Ø 16 ) 5000 (Guide tube Ø 0 ) Mounting flange DIN DN 50... DN 15, PN 10, Form A ANSI "... 5", Class 150 FF Float Material PVC Polypropylene PVDF Float diameter from 44... 80 Float selection depending on guide tube diameter and process conditions (see page 11) Temperature range PVC 0... +60 C Polypropylene -10... +80 C PVDF -10... +100 C Switch function Optionally contact makes S, contact breaks O or change-over U - at increasing level Max. number of 4 x S or O (PP max. 3) resp. 3 x U (PP max. ) contacts Switch position Dimensions L 1, L, L 3... (from sealing face, starting from top) Distance between Minimum 0 (depending on the selection of the float and the contacts, see page 11) switch points Contact rating Contact makes 30 V AC; 100 VA; 1 A 30 V DC; 50 W; 0.5 A Contact breaks 30 V AC; 100 VA; 1 A 30 V DC; 50 W; 0.5 A Please observe contact protection measures (see page 1)! Change-over 30 V AC; 40 VA; 1 A 30 V DC; 0 W; 0.5 A Attention: Versions without protective earth conductor - operation only at safety extra-low voltage e.g. WIKA contact protection relay or external earthing Mounting position Vertical ± 30 Ingress protection IP 54 per EN 60 59 / lec 59 IP 65 per EN 60 59 / lec 59 Page 8 of 14 WIKA Data Sheet LM 30.01 01/010

Stainless steel version, E-CTFE coated Process connection, guide tube material and float made of stainless steel 1.4571, E-CTFE coated Flange (Guide tube diameter 1 ) Flange (Guide tube diameter 18 ) Electrical connection Aluminium 64 x 58 x 34, with 1 contact Aluminium 80 x 75 x 57, or more contacts Option: Polypropylene, polyester, stainless steel Process connections Mounting flange DIN DN 50... DN 00, PN 6... PN 40 ANSI "... 8", Class 150... 300 Guide tube diameter 1 18 Guide tube length L max. 000 4000 Float Temperature range Switch function Max. number of contacts Switch position Distance between switch points Material stainless steel 1.4571 (E-CTFE coated) Float diameter from 45... 11 Float selection depending on guide tube diameter and process conditions (see page 10) Depending on medium Optionally contact makes S, contact breaks O or change-over U - at increasing level 3 x S or O, resp. x U Dimensions L 1, L, L 3... (from sealing face, starting from top) Minimum 0 (depending on the selection of the float and the contacts, see page 10) Contact rating Contact makes 30 V AC; 100 VA; 1 A 30 V DC; 50 W; 0.5 A Contact breaks 30 V AC; 100 VA; 1 A 30 V DC; 50 W; 0.5 A Please observe contact protection measures (see page 1)! Change-over 30 V AC; 40 VA; 1 A 30 V DC; 0 W; 0.5 A Mounting position Vertical ± 30 Attention: Versions without protective earth conductor - operation only at safety extra-low voltage e.g. WIKA contact protection relay or external earthing Ingress protection IP 65 per EN 60 59 / lec 59 WIKA Data Sheet LM 30.01 01/010 Page 9 of 14

Spherical floats (K) Ø C D E B D = Limit S. G. of the medium iersed float volume 85 % E = Nominal S. G. of the medium iersed float volume 50 % Ø A Material Suits guide tube Ø Ø A B Ø C Max. working pressure bar Max. operating temperature C Limit S. G. 85 % kg/m 3 Nominal S. G. 50 % kg/m 3 Stainless steel 1.4571 8 9 8 9 6 100 977 1660 8 9 8 9 5 100 1069 1817 1 5 5 15 40 300 769 1307 1 6 61 15 3 300 597 1015 1 83 81 15 5 300 408 693 18 80 76 3 5 300 679 1155 18 98 96 3 5 300 597 1016 18 105 103 3 5 300 533 907 18 10 117 3 5 300 389 661 Titanium 3.7035 8 9 8 9 30 100 8 1397 1 5 5 15 5 300 707 101 1 5 5 15 60 300 85 1448 1 5 5 15 80 300 1060 180 1 6 6 15 5 300 505 859 1 83 81 15 5 300 78 473 18 80 76 3 5 300 665 1130 18 98 96 3 5 300 495 841 18 105 103 3 5 300 369 67 18 10 117 3 5 300 39 560 Stainless steel 1.4571 1 53 53 14 5 depending on medium 745 166 E-CTFE coated 1 63 6 14 5 depending on medium 591 1005 1 84 8 14 5 depending on medium 403 685 18 81 77 5 depending on medium 718 10 18 99 97 5 depending on medium 675 1148 18 106 104 5 depending on medium 633 1076 18 11 118 5 depending on medium 459 781 Note: The optimum float will be selected after a feasibility test carried out by WIKA. Page 10 of 14 WIKA Data Sheet LM 30.01 01/010

Cylindrical floats (Z) Ø C D E B D = Limit S. G. of the medium iersed float volume 85 % E = Nominal S. G. of the medium iersed float volume 50 % Ø A Material Suits guide tube Ø Ø A B Ø C Max. working pressure bar Max. operating temperature C Limit S. G. 85 % kg/m 3 Nominal S. G. 50 % kg/m 3 Stainless steel 1.4571 8 7 31 10 16 100 787 1338 1 44 5 15 16 300 818 1390 Titanium 3.7035 1 44 5 15 16 300 70 14 Buna 8 0 0 9 3 80 939 1597 8 3 5 9 3 80 80 1364 8 5 14 9 3 80 787 1337 8 30 45 13 3 80 683 1161 1 40 30 15 3 80 581 988 1 40 10 15 3 80 409 694 18 50 45 19 3 80 498 847 PVC 1 44 44 14 3 60 651 1107 16 55 54 3 60 798 1357 0 55 80 6 3 60 919 1563 16 55 70 3 60 674 1145 0 80 79 5 3 60 573 974 Polypropylene 8 7 9 9 3 80 755 184 8 35 33 9 3 80 675 1148 1 44 44 14 3 80 478 81 16 55 54 3 80 58 989 0 55 80 6 3 80 669 1137 0 80 79 5 3 80 431 73 PVDF 1 44 55 14 3 100 78 139 16 55 69 3 100 81 1396 0 55 80 6 3 100 1140 1938 0 80 79 5 3 100 681 1157 Stainless steel 1.4571 E-CTFE coated 1 45 53 14 16 depending on medium 78 139 Note: The optimum float will be selected after a feasibility test carried out by WIKA. WIKA Data Sheet LM 30.01 01/010 Page 11 of 14

Contact protection measures To ensure reliable operation of sensors with reed switches and highest possible service life, we recoend using one of the following circuits. Inductive load AC S1 Surge current measurement with oscilloscope S1 C R E 4-30V AC R C RC modules depending on operating voltage see table Example: C = 0.33 µf/4 V DC 4 V DC R M Inductive load DC + 4-50V DC S1 Shunt diode e.g. 1N4007 I (A) 4 3 1 3-10 without current limitation with current limitation not allowed allowed Current limitation with capacitive load e.g. PLC, DCS and cables > 50 m Protective RC modules t (? µ s) + 4 V DC S1 R S C 1 SPS Rs = Ohm (47 Ohm with 0 VA contacts) C 1 = internal capacitance RC modules are, depending on the operating voltage, to be used exclusively according to the table below. D L D = Ø 16 - Ø 5 L = 6-58 Current limitation with electronic timers 00 wire + 30 V AC S1 R S C 1 time Zeitrelais relay Rs = 0 Ohm (30 V AC) C 1 = internal capacitance For inert gas contacts from 10... 40 VA Capacitance Resistance Voltage 0.33 µf 100 Ohm 4 V AC 0.33 µf 0 Ohm 48 V AC 0.33 µf 470 Ohm 115 V AC 0.33 µf 1500 Ohm 30 V AC For inert gas contacts from 40... 100 VA Capacitance Resistance Voltage 0.33 µf 47 Ohm 4 V AC 0.33 µf 100 Ohm 48 V AC 0.33 µf 470 Ohm 115 V AC 0.33 µf 1000 Ohm 30 V AC Other types than the RC modules specified here might lead to destruction of the reed contact. Page 1 of 14 WIKA Data Sheet LM 30.01 01/010

Connection diagrams Colour coding per IEC 757 PVC cable Silicone cable Contact makes or breaks Change-over Contact makes or breaks Change-over Contact makes or breaks Change-over switch points 3 switch points 4 switch points L4 5 switch points VT L4 L5 switch points 3 switch points / 4 switch points / VT / L4 switch points 3 switch points switch points 1 switch points 1 3 4 3 switch points 1 3 4 5 6 4 switch points 1 3 4 5 6 7 L4 8 5 switch points 1 3 4 5 6 7 L4 8 VT 9 L5 CLEAR 10 1 3 switch points 1 3 4 5 6 3 switch points 1 OG 3 4 5 6 7 8 9 4 switch points 1 OG 3 4 5 6 7 8 9 10 VT 11 L4 CLEAR 1 6 switch points 6 switch points / / VT L4 L5 L6 1 3 4 5 6 7 8 VT 9 CLEAR 10 11 OG 1 L4 L5 L6 WIKA Data Sheet LM 30.01 01/010 Page 13 of 14

Connection diagrams Colour coding per IEC 757 Coupler connector ASC4 Coupler connector M1 Contact makes or breaks Change-over 1 1 3 1 4 3 3 switch points 1 3 1 3 4 5 PE 1 4 Float switches with thermal contacts PVC or silicone cable or terminal box PVC cable Silicone cable or terminal box PVC or silicone cable or terminal box PVC cable 1 Thermal contact Thermal contacts Thermal contacts 1 Thermal contact Thermal contacts Thermal contacts 1 3 4 ϑ ϑ 55 C ϑ 75 C 1 3 4 5 6 ϑ 55 C ϑ 75 C 1 3 4 5 ϑ / ϑ 55 C ϑ 75 C 1 OG 3 4 5 6 7 ϑ 55 C ϑ 75 C Coupler connector ASC4 Coupler connector M1 Coupler connector M1 1 Thermal contact 1 3 ϑ 1 Thermal contact 1 3 4 ϑ 1 Thermal contact 1 3 4 5 ϑ Ordering information Model / Version / Electrical connection / Process connection / Guide tube diameter / Guide tube length L / Information about contact (switch function, number of switch points, switch position) / Process details (operating temperature and pressure, Limit S. G.) / Options Modifications may take place and materials specified may be replaced by others without prior notice. Specifications and dimensions given in this leaflet represent the state of engineering at the time of printing. Page 14 of 14 WIKA Data Sheet LM 30.01 01/010 WIKA Alexander Wiegand SE & Co. KG Alexander-Wiegand-Straße 30 63911 Klingenberg/Germany Tel. (+49) 937/13-0 Fax (+49) 937/13-406 E-mail info@wika.de www.wika.de 01/010 GB