TLC SCANNER. Model ~ HY-3 TRACER METHODOLOGY IN PET LABS, BIOCHEMISTRY, BIOMED AND CLINICAL LAB, RADIOPHARMACY & NUCLEAR MEDICINE

Similar documents
AIR or STACK MONITOR GAS, GROSS BETA-GAMMA PARTICULATE, & IODINE

WELL COUNTERS AND ACCESSORIES LIST OF CONTENTS:

Table of contents. Document Number Station1\D1:\TriathlerManuals\Triathler Catalogue Transfer.doc

Model ST370 Radiation Counter

DOSE CALIBRATOR LIST OF CONTENTS: CRC -55tR Dose Calibrator 2 CRC -55tWDose Calibrator/Well Counter.5. CRC -55tPETDose Calibrator 9

stand, set connector on the electronics unit and plugg it in an outlet. supply to the

Model ST360 Radiation Counter

Fits you like no other

MULTI COUNTER - timer, counter, freq, geiger

1/4 Specifications Hidex 300 SL automatic TDCR liquid scintillation counter

Fits you like no other

SDI-5510 Vertical Flat Through Transmission Inspection System. Technical Specification

Hidex 300 SL automatic TDCR liquid scintillation counter

Electronic SD1, AS 8, ASR 14, ASR 20

DX-D 300. Flexible Direct Radiography System

SVG3 (Basic Equipment)

Falcon Portable HPGe-Based Radionuclide Identifier. Radiation Safety. Amplified. KEY FEATURES DESCRIPTION.

LB 134 Universal Monitor II ID No.: 62688BA2 Rev. No.:

Thermo Scientific Automatic 60 mm Sample Changer FHT 770 G-60 Technical Specification ZT-215E-1202

LUDLUM MODEL ALPHA/BETA DETECTOR. August 2015

IEEE Nuclear Power Engineering Standards Collection VuSpec - Active Only

Chapter 3. Experimental Procedure

Introduction to Positron Emission Tomography

ORTEC ISO-CART. A Complete In-Situ NDA Gamma-Ray Analysis for a Wide Variety of Samples. Mobile Assay System

PRODUCTS RS-500 AIRBORNE RS-700 AIRBORNE

UCS 10. Operating Manual. Spectrum Techniques, Inc. Oak Ridge, Tenn. USA. Universal Computer Spectrometer. August 1996

ERG Model 102 F/W Scanning Systems

Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment

EElectronic Devices and Systems. EK-87 Electronic Volume Corrector. This product is discontinued!

IDM-200 -V. Interchangeable HPGe Detector Module (IDM) for Systems Integrators

DX-D 300. Flexible Direct Radiography System

UCS-20. Operating Manual Macintosh Edition. Spectrum Techniques, Inc. Oak Ridge, Tennessee USA. Universal Computer Spectrometer.

Cherenkov Radiation. Doctoral Thesis. Rok Dolenec. Supervisor: Prof. Dr. Samo Korpar

FLEXIBLE DIRECT RADIOGRAPHY SYSTEM DX-D 300

EAG SYSTEM SIGNAL ACQUISITION SYSTEMS

High-Speed Data Acquisition System

ISO-CART-II. Mobile Assay System. An optimized transport system for in-situ waste measurements.

DX-D 300 FLEXIBLE DIRECT RADIOGRAPHY SYSTEM DX-D 300

IS-3000-LS-ABB INFRARED SCANNER

ED-1100 PORTABLE VARIABLE EDDY CURRENT INSTRUMENT

CHAPTER 11 NUCLEAR MEDICINE IMAGING DEVICES

Performance Evaluation of 3-Axis Scanner Automated For Industrial Gamma- Ray Computed Tomography

Philips SPECT/CT Systems

Using the Bruker Tracer III-SD Handheld X-Ray Fluorescence Spectrometer using PC Software for Data Collection

DX-D 300 FLEXIBLE DIRECT RADIOGRAPHY SYSTEM DX-D 300 DR SYSTEM

ORTEC. Alpha Aria. Alpha Duo. Alpha Ensemble. Alpha Suite All-In-One Integrated Alpha Spectrometers

BENCHMIKE PRO NEW. The Industry s leading off-line ID/OD/Wall measurement system

TEL-218DRV TEL-X-Driver

Cronos -1 Gamma Object / Tool Monitors

BENCHMIKE 283 SERIES. BETA LaserMike. Off-Line ID/OD/Wall measurement systems for pipe and tube samples

HIGH-VOLTAGE. browse our website for complete specifications. Your Source for Low & High Voltage Power Solutions

Eberline Smart Portable Technical Manual

AB Axis Industries. Use

One (1) acoustic and three (3) seismic channels. Three (3) component velocity output. All units are interchangeable with accuracy within two percent.

Continuation Format Page

Interface Module IM-ME 40 for Counter ME40.xx

Cronos -4 and Cronos -11 Gamma Object / Tool Monitors

Validation of GEANT4 for Accurate Modeling of 111 In SPECT Acquisition

TTS Series of Computer Controlled Universal Testing Machines Specification Sheets

Mediso AnyScan S Single-Head and Dual-Head SPECT

SigmaCheck. Fully Featured Eddy Current Conductivity Meter ET NDE

The smaller, simpler, safer alternative to radioisotope irradiators. Precision s MultiRad160 is ideal for irradiating larger cell cultures and/or

LECTURE 15. Dr. Teresa D. Golden University of North Texas Department of Chemistry

analysette 18 particle size analysis quality control sieving for your lab Heavy Duty Analytical Sieve Shaker

Mediso AnyScan. Single-Head and Dual-Head SPECT

MEDICAL IMAGING 2nd Part Computed Tomography

Versatile. Innovative. Customizable M CVAF Mercury Analyzer

Model ISOXSHLD ISOCS Shield Systems

MICRO BURN IN PRODUCTS LISTED IN MODEL NUMBER ORDER FOLLOWED BY A BRIEF DESCRIPTION

MAESTRO 7. Multichannel Analyzer (MCA) Application Software

Surgical Probe CXS-OPSZB Control Unit CXS-SG03

The BF200 Blown Film Gauge. SolveTech, Inc.

DX-D 100 with wireless detector

BENCHMIKE 283 SERIES. Off-Line ID/OD/Wall measurement systems for pipe and tube samples

Hardness Tester Micro-Vickers Type HM-100

SL2400 Compact Monitor

SNIC Symposium, Stanford, California April The Hybrid Parallel Plates Gas Counter for Medical Imaging

NF760 Batch Controller

Panel Indicators. NEW 4~20mA Panel Display. Process Indicators INTECH INSTRUMENTS.

RAM-ION Ion Chamber OPERATING MANUAL. Wide Range Gamma, X-Ray, and Beta Radiation Measurement

Fujifilm DR Solution. FDR AcSelerate. The new pinnacle in diagnostic imaging from Fujifilm ISS. CsI. Dynamic Visualization. Technology.

Counting On Your Process Preset Counters

DISI-A Automatischer Tablet. DISI-A Automatic. high accuracy. Precise measuring reliable results

Thermal OEM Laser Heads

D-R300 / D-R320 / D-R 800 DATASHEET

idim Standalone idim idim Sense (316) (Master ) idim Ballast s idim Sol o Multisensor (312), (PIR extension) idim Sense (316) (PIR extension)

Accumeasure TM Capacitance Probes

PCM 770 SYSTEM. for Signal Conditioning, Data Acquisition and PCM Encoding. Lancaster

DX-D 100 with WITH ITS EXCELLENT IMAGE QUALITY AND

1. Introduction... 3 Features... 4 Main Panel Controls Operation... 6 Survey Meter Modes... 6 USB/TTL Adapter... 7 Graphing Software...

Micro-UF6. Portable UF6 Cylinder Verification System

User Manual. Low-level beta GM multicounter system Model Risø GM-25-5A

Fischerscope X Ray CIRCULARS 07/01

MPT-250A SPECIFICATIONS AND OPERATING INSTRUCTIONS

1. Introduction... 3 Features... 4 Main Panel Controls... 5 USB/TTL Adapter... 6

The Original Green LED Incorporated Digital Micrometer

Quantum MCA2500R SYSTEM MANUAL

Introduction to Emission Tomography

LUDLUM MODEL GEO-EXPLORATION COUNTER. April 2018 Serial Number and Succeeding Serial Numbers

Timken Lubrication Delivery Systems. Friction management solutions SM to keep systems running smoothly

Transcription:

FEATURES ACCEPTS PAPER CHROMATOGRAMS, TLC PLATES, & ELECTROPHORESES ULTRA SENSITIVE SCANS UP TO SIX TRACES SIMULTANEOUSLY THREE DETECTOR TYPES FOR ANY NUCLIDE GM OR GAS FLOW OR SCINITLLATION DETECTORS BETAS: H-3, C-14, P-32, etc... GAMMAS: Fe-55, I-125, Tc-99m, HY-3 etc... HIGH PRECISION AT ALL SPEEDS DUE TO DIGITAL DRIVE WILL DETECT LOWER LEVELS THAN ANY PREVIOUS SCANNER QUANTITATIVE EASY INTEGRATION OF AREA UNDER PEAK MAY BE INTERFACED TO COMPUTER OR COMPUTING INTEGRATOR LARGE 10 X 20 TABLE HY-3 ELECTRONICS & TABLE SCANNER APPLICATION: TRACER METHODOLOGY IN PET LABS, BIOCHEMISTRY, BIOMED AND CLINICAL LAB, RADIOPHARMACY & NUCLEAR MEDICINE DESCRIPTION: The HY-3 allows samples & standards to be spotted on the same TLC and plotted together on the same strip chart, thus giving exact comparison between peak locations & heights in the samples and standards. It also allows up to six paper strips to be counted simultaneously, thus substantially decreasing the time as compared to serial paper strip counters. Use in electrophorogram scanning grants the same benefits. Sensitivity is extremely broad. Travel increment and dwell time of the sample under the detector are controllable over a broad range. This system is useful for any isotope and allows unattended scanning of even very low level chromatograms. The HY-3 is an automatic scanner for TLC s, gels, paper chromatograms & electrophoreses. A moving 10 x 20 table carries two 20cm x 20 cm TLC s or other samples in controlled steps under a bridge, examines traces on the sample and transfers information to printer or strip chart recorder. Detectors are interchangeable. TF-1212 gas flow detectors are standard & sensitive to all Betas except Tritium. Also available are the thin window scintillation detectors which are highly sensitive to low energy Gammas (such as those from I-125, Tc-99m, etc...) and are also very sensitive to Betas above 200KeV.

FEATURES: ULTRA-SENSITIVE - WILL DETECT LOW LEVELS OF: H-3 C-14 P-32 I-131 SPARTIAL RESOLUTION: 1MM A unique feature is the digital step control of movement. The sample (as well as the strip chart) is advanced a preset distance (1, 2, 5, or 10mm), then counted for a time presettable from one second to 3000 seconds (1, 3, 10, 30, 100, 300, 1000, 3000 sec.), allowing variations from a very rapid scan to a slow scan for the greatest accuracy even in extremely low level samples. Readout may be via a 10 wide Chart Recorder with all parallel samples presented on one chart, or may be as numbers in a digital printer, or interfaced with a data processor or computer. Another unique feature is the ability to read out digitally, in addition to, or instead of, chart recorder readout. With low activity samples, the count time may be as long as 3000 seconds per position. A set of collimators is furnished with each detector giving resolution from 1mm to the full 6mm diameter of the detector. Wider detectors for streak scanning are also available. The strip chart readout is presented in the form of a histogram allowing rapid quantitation so other type summation is not necessary. The digital scaler which is an integrating strip chart recorder is available. The digital system utilizes the most frequently used fully computer compatible bus for direct hook-up to micro-processor, computing integrator or computer. Each scanner consists of four primary functional sections: 1. The moving table and its control mechanism (all modular) together with the detector mounting bridge and locating mechanism. 2. The modular electronics package consisting of bias supplies for detectors, plus amplifiers, signal conditioners, ratemeters, and counters for detectors. 3. The detectors themselves, which may be sealed thin-end window GM tubes, gas flow counters, or thin window scintillators. The proper choice of detector allows excellent counting efficiency for practically all nuclides. 4. The hard copy presentation and its interface; consisting of multichannel strip chart recorder or digital printer or output to computer or data processor.

SPECIFICATIONS: I. TABLE AND CONTROL MECHANISMS: Samples accepted: one to two 20cm plates in series, one to six strips up to 40cm long in parallel, or up to 12 strips up to 20cm long. Table Dimensions: Case Dimensions: Weight: Modules and Components: Housed in Table Transport 25.4cm x 50.8cm 53cm x 30cm D x 30cm H 20 kg. MSP-5 Power Supply. MCL-5 Motor Drive Control Logic Table & Cabinet: MTM-5 Translator-Controller exactly synchronizes motors of table and chart recorder; step lengths 1, 2, 5, 10mm (equivalent table speeds are from 3mm/sec to 1.2mm/hr), or table can be moved manually in a continuous fashion. MTR-5 Digital Drive Motor. Table and Drive Chain. Detector Mounting Bridge Case. II. MODULAR COUNTING-ELECTRONICS PACKAGE: Dimensions: Weight: Modules: Ratemeter Systems: Digital Systems: III. DETECTORS: Three Basic Detector Types: Mounting: Distance Above TLC: Lateral Position: 21 W x 16 D x 11 H. 20 lbs All modules are T/A s standard FM-9 modules as follows: MVR-5R High Voltage bias supply continuously variable 0-2000 V exactly resettable, also supplies operating voltages for the various modules 12V, 5V. MPT-5E times. Count times (same as table and recorder dwell times): 1, 3, 10, 30,100, 300 1K, 3k seconds. Additional optional FM-9 modules may be added: MGA-5 single channel analyzer. MAM-5 Ratemeter (one for each detector) ranges: 0-500, 5000, 50000, 500000 cpm full scale. Time Constants: Continuous variable to 20sec. MSM-5 Scales (one for each detector) 5 digits plus overflow indicator; counts to 199,999. GM, Gas Flow, Scintillation. 1 to 6 detectors mount on detector bridge directly above chromatogram. Continuously and repeatable adjustability by screwdriver from 2cm down to contact between detector face and chromatogram. Continuously and repeatable adjustability along 26cm long linear track, and firmly held in place.

See Detector Chart for complete Specifications. IV. HARD COPY READOUTS: Strip Chart Recorder - Model RCR-5 8 wide, digital drive, travel distance linear to TLC traverse rate. Stepping Speeds: Same as Sample Table see I. TABLE AND CONTROL MECHANISMS: Dwell Time: Outputs: Same as Sample Table. I. TABLE AND CONTROL MECHANISMS: Can drive additional distant meter or chart recorder. Pulse train information for a counter Transfer pulses. Timing information. Digital Printer for One or Two Channel System - Model MPM-5 Date: Position: Outputs: 4 digits plus overflow. 2 digits reads in mm. Rs-232 serial output. Parallel Line BCD. Pulse Train. Presettable contact closure if peak exceeds a certain value. Digital Printer for Three to Six Channel System - Model MPD-40. Complete Computer Analysis System: Separate, independent counters for each detector on Data acquisition module. Complete data acquisition, analysis, display, recording, and printing. OVERALL SYSTEM SPECIFICATIONS: Power Requirements: 50-60 hz 110 VAC (220 VAC optional).

DETECTOR CHART MODEL: T-1212 GF-1212 PGS-7 DETECTOR: GM Gas Flow* Na(Tl) Scintillation SENSITIVE DIAMETER: T-1212 T-1210 6mm 25mm 6mm 6mm WINDOW THICKNESS: 1.5-2.0mg/cm windowless 5mil Al; 35mg/cm SENSITIVE MATERIAL: Halogen Quenched Geiger Gas Any Standard Proportional or Geiger Counting Gas NaI(Tl): PGS-7, 2mm thick PGS-76, 6mm thick Better for gamma >200KeV MAX NUMBER DETECTORS MOUNTABLE ON SINGLE BRIDGE: 6 6 4 TYPICAL BACKGROUND COUNT RATE IN.02mR/hr FIELD (very low): T-1212 T-1210 1/2 mm 1cpm 20cpm 1/2-1cpm PGS-7 140cpm PGS-76 400cpm RADIATIONS DETECTED & MINIMUM ENERGIES: Alpha, Beta (140KeV), Gamma <1% efficiency Alpha, Beta (40KeV), Gamma <1% efficiency Beta (200KeV), Gamma (5Kev) TYPICAL NUCLIDES DETECTED: C-14 Co-57 P-32 Ca-45 H-3 C-14 and all nuclides shown for T-1212. Fe-55 I-125 Tc-99m I-131 COLLIMATORS AVAILABLE: 1mm dia. 2mm dia. 4mm dia. 1mm slot Other on Request 1mm dia. 2mm dia. 4mm dia. 1mm slot Other on Request 1mm dia. 2mm dia. 4mm dia. 1mm slot Other on Request SHIELDING: Available Available Available *For Geiger or Proportional Use. Wider detectors with longer slot collimators are available for scanning streaked plates. Gases available from Technical Associates or any large gas company.

ISOTOPES & SENSITIVITY ISOTOPE C-14 P-32 I-131 H-3** C-14** I-125 Tc-99m APPROX. SYSTEM SENSITIVITY: 10-20% 38% 32% 1/2-3% 30-40% 15% PGS-7: 5% PGS-76: 10% APETURE MINIMUM QUANTITIES DETECTABLE IN picoci: 5mm (3) 1mm (3) 5mm (4) 1mm (4) 60-120 1,200 3 0.01 60 600 1.5 0.005 60 600 1.5 0.005 700-4200 7,000-42,000 80 0.3 1,200 2,000 150 0.45 1,600 2,600 100 0.3 **Self-absorption in the chromatography medium it the limiting factor in sensitivity for C-14 and Tritium. (3) Minimum activity which can be quantitatively measured with good accuracy in an overnight scan. (4) Minimum activity which can be detected with 95% confidence in an overnight scan. GM - Betas: All Betas that penetrate the window will count. Gas Flow - Betas: All Betas that go into the detector will count.