ABSTRACT 1. INTRODUCTION

Similar documents
Real-time self-calibration of a tracked augmented reality display

Intraoperative Ultrasound Probe Calibration in a Sterile Environment

Enabling Technologies for Robot Assisted Ultrasound Tomography

We are IntechOpen, the world s leading publisher of Open Access books Built by scientists, for scientists. International authors and editors

Introduction to Digitization Techniques for Surgical Guidance

3D Ultrasound System Using a Magneto-optic Hybrid Tracker for Augmented Reality Visualization in Laparoscopic Liver Surgery

Real-Time Data Acquisition for Cardiovascular Research

A New Approach to Ultrasound Guided Radio-Frequency Needle Placement

CALIBRATION ALGORITHM FOR FREEHAND ULTRASOUND

Mech. Engineering, Comp. Science, and Rad. Oncology Departments. Schools of Engineering and Medicine, Bio-X Program, Stanford University

Calibration Method for Determining the Physical Location of the Ultrasound Image Plane

Intraoperative Prostate Tracking with Slice-to-Volume Registration in MR

Skull registration for prone patient position using tracked ultrasound

Validation System of MR Image Overlay and Other Needle Insertion Techniques

Monitoring electromagnetic tracking error using redundant sensors

Real-time transverse process detection in ultrasound

The team. Disclosures. Ultrasound Guidance During Radiation Delivery: Confronting the Treatment Interference Challenge.

Ultrasound Calibration Framework for the Image-Guided Surgery Toolkit (IGSTK)

Prototyping clinical applications with PLUS and SlicerIGT

Towards webcam-based tracking for interventional navigation

Active Echo: A New Paradigm for Ultrasound Calibration

Improved temporal calibration of tracked ultrasound: an open-source solution

DESIGN OF A FLEXIBLE OPTICAL TRACKER FOR ORTHOPAEDIC NAVIGATION

Image Thickness Correction for Navigation with 3D Intra-cardiac Ultrasound Catheter

An Automated Ultrasound Calibration Framework Incorporating Elevation Beamwidth for Tracked Ultrasound Interventions

Projection-Based Needle Segmentation in 3D Ultrasound Images

Lecture 6: Medical imaging and image-guided interventions

Development of Pseudo 3D Visualization System by Superimposing Ultrasound Images

University of Cambridge Department of Engineering Trumpington Street Cambridge CB2 1PZ United Kingdom

3D-printed surface mould applicator for high-dose-rate brachytherapy

Which Pivot Calibration?

A model-based approach for tool tracking in laparoscopy

Step-wise identification of ultrasound-visible anatomical landmarks for 3D visualization of scoliotic spine

Trackerless Surgical Image-guided System Design Using an Interactive Extension of 3D Slicer

Ultrasound Probe Tracking for Real-Time Ultrasound/MRI Overlay and Visualization of Brain Shift

A Novel Phantom-Less Spatial and Temporal Ultrasound Calibration Method

Position accuracy analysis of the stereotactic reference defined by the CBCT on Leksell Gamma Knife Icon

C-mode Real Time Tomographic Reflection for a Matrix Array Ultrasound Sonic Flashlight

Sensor-aided Milling with a Surgical Robot System

Novel Reconstruction and Feature Exploitation Techniques for Sensorless Freehand 3D Ultrasound

A Novel Laser Guidance System for Alignment of Linear Surgical Tools: Its Principles and Performance Evaluation as a Man Machine System

Virtual Touch : An Efficient Registration Method for Catheter Navigation in Left Atrium

SlicerRT Image-guided radiation therapy research toolkit for 3D Slicer

INTRODUCTION TO MEDICAL IMAGING- 3D LOCALIZATION LAB MANUAL 1. Modifications for P551 Fall 2013 Medical Physics Laboratory

Out-of-plane motion estimation based on a Rician-Inverse Gaussian model of RF ultrasound signals: speckle tracking without fully developed speckle

Use of Ultrasound and Computer Vision for 3D Reconstruction

Augmented reality visualization for orthopedic surgical guidance with pre- and intra- operative multimodal image data fusion

An Accuracy Approach to Robotic Microsurgery in the Ear

INVESTIGATION OF THE POTENTIAL OF LOW COST POSITION TRACKING USING PERMANENT MAGNETS

Vision-based endoscope tracking for 3D ultrasound image-guided surgical navigation [Yang et al. 2014, Comp Med Imaging and Graphics]

Direct Co-Calibration of Endobronchial Ultrasound and Video

NIH Public Access Author Manuscript Proc Soc Photo Opt Instrum Eng. Author manuscript; available in PMC 2014 July 28.

Fractional labelmaps for computing accurate dose volume histograms

University of Cambridge Department of Engineering Trumpington Street Cambridge CB2 1PZ United Kingdom.

NA-MIC National Alliance for Medical Image Computing SlicerRT Extension

Navigated and Robotized Transcranial Magnetic Stimulation based on 3D Laser Scans

Dynamic management of segmented structures in 3D Slicer

Open-source software for collision detection in external beam radiation therapy Vinith M. Suriyakumar, Renee Xu, Csaba Pinter, Gabor Fichtinger

Photoacoustic Image Guidance for Robot-Assisted Skull Base Surgery

Endoscopic Navigation for Minimally Invasive Suturing

Image-Guided Interventions Technology and Applications. Organizers: Emad Boctor, Pascal Fallavollita, Ali Kamen, Ziv Yaniv

Confidence Weighted Local Phase Features for Robust Bone Surface Segmentation in Ultrasound

Real-time Tissue Tracking with B-Mode Ultrasound Using Speckle and Visual Servoing

Using Registration Uncertainty Visualization in a User Study of a Simple Surgical Task

Fully Automatic Endoscope Calibration for Intraoperative Use

Multisensor Coordinate Measuring Machines ZEISS O-INSPECT

Introducing Computer-Assisted Surgery into combined PET/CT image based Biopsy

A 3D photographic capsule endoscope system with full field of view

(b) (a) 394 H. Liao et al. Fig.1 System configuration

arxiv: v1 [cs.cv] 31 Jul 2016

Thin Plate Spline Feature Point Matching for Organ Surfaces in Minimally Invasive Surgery Imaging

Thank-You Members of TG147 TG 147: QA for nonradiographic

Robot-assisted MRI-guided prostate biopsy using 3D Slicer

Image Guided Navigation for Minimally Invasive Surgery

EFFECTS OF KEY SIZE AND SPACING ON THE COMPLETION TIME AND ACCURACY OF INPUT TASKS ON SOFT KEYPADS USING TRACKBALL AND TOUCH INPUT

A Robust Meshing and Calibration Approach for Sensorless Freehand 3D Ultrasound

Software Strategy for Robotic Transperineal Prostate Therapy in Closed-Bore MRI

A Study of Medical Image Analysis System

Precise Ultrasound Bone Registration with Learning-based Segmentation and Speed of Sound Calibration

SYSTEM LINEARITY LAB MANUAL: 2 Modifications for P551 Fall 2013 Medical Physics Laboratory

Computed Photography - Final Project Endoscope Exploration on Knee Surface

PCMM System Specifications Leica Absolute Tracker and Leica T-Products

PCMM System Specifications Leica Absolute Tracker and Leica T-Products

Real-Time 4D Ultrasound Mosaicing and Visualization

Development and validation of a short-lag spatial coherence theory for photoacoustic imaging

A laboratory-dualsphysics modelling approach to support landslide-tsunami hazard assessment

4D Shape Registration for Dynamic Electrophysiological Cardiac Mapping

A fast breast nonlinear elastography reconstruction technique using the Veronda-Westman model

Precision and repeatability analysis of Optotrak Certus as a tool for gait analysis utilizing a 3D robot

A New Method for CT to Fluoroscope Registration Based on Unscented Kalman Filter

3D Slicer Overview. Andras Lasso, PhD PerkLab, Queen s University

Towards an Ultrasound Probe with Vision: Structured Light to Determine Surface Orientation

Hybrid Analysis of a Spherical Mechanism for a Minimally Invasive Surgical (MIS) Robot - Design Concepts for Multiple Optimizations

Freehand Spatial-Angular Compounding of Photoacoustic Images

Suturing in Confined Spaces: Constrained Motion Control of a Hybrid 8-DoF Robot

연구용유방초음파질관리 원광대학병원김혜원

USING A TRACKING LASER INTERFEROMETER TO CHARACTERIZE THE PLANARITY OF A PLANAR NEAR-FIELD SCANNER

Response to Reviewers

Industrial Metrology. Multisensor Measuring Machines O-INSPECT 322/442

PRODUCT CATALOGUE May 2008

Transcription:

Tracked ultrasound calibration studies with a phantom made of LEGO bricks Marie Soehl, Ryan Walsh, Adam Rankin, Andras Lasso, Gabor Fichtinger Queen s University, Kingston ON, Canada ABSTRACT PURPOSE: In this study, spatial calibration of tracked ultrasound was compared by using a calibration phantom made of LEGO bricks and two 3-D printed N-wire phantoms. METHODS: The accuracy and variance of calibrations were compared under a variety of operating conditions. Twenty trials were performed using an electromagnetic tracking device with a linear probe and three trials were performed using varied probes, varied tracking devices and the three aforementioned phantoms. The accuracy and variance of spatial calibrations found through the standard deviation and error of the 3-D image reprojection were used to compare the calibrations produced from the phantoms. RESULTS: This study found no significant difference between the measured variables of the calibrations. The average standard deviation of multiple 3-D image reprojections with the highest performing printed phantom and those from the phantom made of LEGO bricks differed by 0.05 mm and the error of the reprojections differed by 0.13 mm. CONCLUSION: Given that the phantom made of LEGO bricks is significantly less expensive, more readily available, and more easily modified than precision-machined N-wire phantoms, it prompts to be a viable calibration tool especially for quick laboratory research and proof of concept implementations of tracked ultrasound navigation. Keywords: Tracked ultrasound, calibration, phantom. N-wire phantom 1. INTRODUCTION Real-time tracked ultrasound imaging is a non-invasive and safe approach to facilitate needle-based interventions such as biopsy, drug delivery and surgical ablation. These procedures require a degree of accuracy maintained by an accurate and consistent spatial and temporal calibration that relates the image pixels of the ultrasound to the coordinate system of the tracked probe. An object of known geometry (calibration phantom) is frequently used for spatial calibration of tracked ultrasound probes (Mercier et al. 2005). One family of phantoms, the so called N-wire phantoms (Chen et al. 2009, Carbajal et al. 2013), have a rigid structure that typically supports a wire configuration of known position within the coordinate system of the phantom. The ultrasound beam intersects with each N motif of the phantom in three locations. Because the relative position of the N motifs are known and because the position of the ultrasound probe is tracked, the spatial orientation of the ultrasound image can be found. Through this method of calibration, the spatial calibration is obtained for every degree of freedom of the ultrasound probe. The N-wire configuration is achieved by placing three wires in an N pattern parallel to each other across the center of the phantom, such as shown in Figure 1 and 2.

Figure 1. N-wire configuration. Figure 2. Ultrasound image plane intersection with wires at the three labeled locations. N-wire phantoms require accurate manufacturing, where 3-D printing may be used to achieve a minimized tolerance necessary in the implementation and segmentation of the wires seen in Figure 2. The calibration phantoms fcal-2.0 and fcal-3.1, shown in Figure 3 and Figure 4, are examples of 3-D printed N-wire phantoms. The protocols and software used with the fcal-2.0/3.1 phantoms by Carbajal were used in this study and are available on the open source Public software Library for Ultrasound research software toolkit (http://www.plustoolkit.org). Grids on opposing sides of the phantom, which the wires pass through, allow for a variety of wiring configurations with easily described locations. The fcal-2.0, with internal dimensions of 4.0 x 10.0 cm and a depth of 3.5 cm, and the fcal-3.1, with internal dimensions of 4.0 x 12.5 cm and a depth of 15.0 cm, can accommodate probes within limitations from their widths (10.0 and 12.5 cm respectively). An easily modifiable, readily available worldwide, and low-cost alternative N-wire phantom is the fcal-l-1.0 (Walsh et al. in review), for which all parts required for fabrication, previously used in medical imaging (Guler et al. 2012), are available by order through the LEGO website. A companion paper by Walsh et al. also accepted for publication at this conference, describes the design process, embodiment and building of the fcal-l-1.0. The internal dimensions of the fcal- L-1.0 are 4.0 x 6.5 cm with a depth of 4.6 cm. The objective of this study was to determine if the fcal-l-1.0 is an adequate calibration tool when measured against the fcal-2.0/3.1 phantoms. This study was designed to compare the accuracy and variance of the fcal-l-1.0 and printed phantoms under various experimental conditions.

2. METHODS For the calibration testing under standard conditions, a SonixTouch (UltraSonix, Richmond, British Columbia, Canada) ultrasound machine with a SonixGPS (UltraSonix) electromagnetic tracking system was used with a L14-5/38 UltraSonix linear probe at a frequency of 10 MHz. The calibration took place in a room temperature water bath with an imaging depth of 45 mm, the typical depth of needle insertions. The phantom, stylus, and ultrasound probe were tracked using a fixed 8 mm electromagnetic position sensor. For equipment testing, where the phantoms were tested using various probes and tracking devices, a C5-2/60 UltraSonix convex probe with a frequency of 5MHz, a BPL9-5/55 UltraSonix side-firing linear wand probe with a frequency of 10MHz, and a Polaris Spectra optical tracker (Northern Digital Inc, Waterloo, Ontario, Canada) were used. The three phantoms used are shown in Figures 3, 4, and 5. All have an N-wire configuration of 30 mm across and 10 mm between each layer of wiring. These dimensions were used due to the results achieved in past studies (Carbajal et al. 2013). Figure 3. fcal-3.1 calibration phantom (Carbajal et al. 2013). Figure 4. fcal-2.0 calibration phantom (Carbajal et al. 2013).

Figure 5. Calibration phantom made of LEGO bricks (Walsh et al. 2013). A stylus calibration was first performed to determine the location of the tip of the stylus. This was achieved by selecting the best result of multiple pivot calibrations. The stylus was then used to locate registration points on the phantom. Then, a spatial calibration was performed by running the ultrasound probe across the wires from one side of the phantom to the other, collecting cross sectional images of the wires in multiple probe orientations at 50 frames per second from the tracker and 30 frames per second from the ultrasound video. To test the spatial calibration with the three phantoms under standard conditions, twenty trials were performed by a single operator on all phantoms. For evaluation of calibrations with various equipment, three trials were completed for each tracker while using the linear probe and three were completed for each probe while using the electromagnetic tracker. The 3-D image reprojection error is used to evaluate the accuracy of calibrations and standard deviation of image reprojections was used to evaluate the variance of calibrations. The error of reprojection was determined through the average distance of multiple transformed points from the image plane to the reference plane from the actual position of the point in the reference coordinate system. The standard deviation is determined by the spread of the locations of the transformed points. To make the error estimation less biased, the collected frames were split into two groups: one group was used for computing the calibration and the other was used for computing the error. 3. RESULTS AND DISCUSSION The average error and average standard deviation over twenty trials are shown for each N-wire phantom in Table 1. Table 1. 3-D reprojection error average and standard deviation values Phantom Average error (mm) Average standard deviation (mm) fcal-3.1 0.91 0.53 fcal-2.0 0.74 0.43 fcal-l-1.0 0.87 0.48 The fcal-2.0 phantom was found to produce the calibrations with the highest accuracy and lowest variance. The fcal-3.1 phantom was found to have the lowest accuracy and highest variance. Calibrations were achieved using both the optical tracker and the electromagnetic tracker, with the optical tracker delivering more accurate calibrations with lower variances.

Electromagnetic tracker Optical tracker The linear and wand probes were able to produce calibrations with all three phantoms. The difference between the accuracy and variance of the fcal-2.0/3.1 and fcal-l-1.0 calibrations was largest when calibrating with the wand probe. In all cases the fcal-2.0 and fcal-l-1.0s achieved calibrations with higher accuracy and lower variance than those with the fcal-3.1 phantom. Exceptions to this were the variance of the fcal-l-1.0 calibration when using the wand probe and how the convex probe was only able to calibrate with the fcal-3.1 phantom. The results of the experiments are shown in Figures 6 and 7. Tracking device comparison LEGO fcal 2.0 fcal 3.1 LEGO fcal 2.0 fcal 3.1 0 0.2 0.4 0.6 0.8 1 1.2 1.4 1.6 1.8 2 Average error Figure 6. Average error of varied tracking devices with average standard deviation shown. Ultrasound probe comparison 2 1.8 1.6 1.4 1.2 1 0.8 0.6 0.4 0.2 0 fcal 3.1 fcal 2.0 LEGO fcal 3.1 fcal 2.0 LEGO fcal 3.1 Linear Wand Convex Average eror Figure 7. Average error of varied ultrasound probes with average standard deviation shown. Under standard conditions the fcal-2.0 and fcal-l-1.0 delivered similar results. The fcal-3.1 produced calibrations with a consistently higher error and greater variance than the other two phantoms. This can be attributed to how the structure requires assembly as a means to minimize cost and printing time given the large region necessary for calibrations at an imaging depth greater than 8 cm and therefore introduces error between configuration and actual geometry. An F-test was performed on the standard deviation of the results collected from the calibrations with fcal-l-1.0 and those collected from the calibrations using the fcal-3.1 and fcal-2.0 phantoms. A summary of these results are shown in table 2. It was found

that all calculated values were less than the F value at p = 0.10. This indicates that no significant variance between the results obtained by the phantom. No result was achieved for the experiments with the convex probe as calibrations were only obtained with the fcal-3.1. The accuracy of the calibrations were analyzed using a two-tailed t-test. The difference between the accuracy of calibrations performed with the fcal phantoms was found to be insignificant, as the calculated values were less than the T value at p = 0.10. This indicates that there was no variance between the accuracy of the calibrations achieved with all three phantoms under standard conditions and all other conditions tested excluding calibrations performed with the convex probe. The accuracy achieved with the convex probe was found to be statistically different between the calibrations with the fcal-l-1.0 versus those with the fcal-3.1. This result corresponds with observed results as the fcal-l-1.0 could not achieve calibrations when using the convex probe. From the statistical analysis on the collected data, it can be concluded that no significant difference was found between the fcal-l-1.0 and 3-D printed phantoms under the tested apparatus, excluding when used with the convex probe. Table 2. A summary of the statistical analyises performed on the results obtained from the fcal-l-1.0 through experimentation and the 3-D printed phantoms. Equipment used Phantom under comparison with FCal-L-1.0 F-test F at P = 0.10 T-test T at P = 0.10 Standard conditions FCal-3.1 1.22 1.88 0.25 1.69 FCal-2.0 1.25 19 0.89 2.13 Linear probe FCal-3.1 2.22 19 0.71 2.13 FCal-2.0 1.41 19 0.18 2.13 Wand probe FCal-3.1 1.18 19 0.05 2.13 FCal-2.0 7.22 19 1.33 2.13 Convex probe FCal-3.1 0 19 2.47 2.13 Electromagnetic tracker FCal-2.0 -- 19 --- 2.13 FCal-3.1 2.22 19 0.71 2.13 FCal-2.0 1.41 19 0.18 2.13 Optical tracker FCal-3.1 2.42 19 0.83 2.13 FCal-2.0 1.03 19 0.18 2.13 Under various experimental conditions it was found that the wand probe achieved the most accurate calibrations. When using the wand probe, however, the fcal-l-1.0 calibrations had the greatest variance of the three phantoms and had more significantly different results from the fcal-2.0 phantom than when under other testing conditions. This discrepancy can be attributed to the structure, specifically the brick circled in Figure 8, of the fcal-l-1.0, which prevented the probe from being positioned parallel to the plane of the wires as is also shown in Figures 8.

Figure 8. LEFT: Probe positioning in the parallel plane. RIGHT: Positioning of the probe with a tilted angle to accommodate the structure of the fcal-l-1.0. Calibrations were achieved with both tracking devices and therefore the three phantoms can be used in protocols requiring either tracker. The linear probe produced the best average calibrations across the three phantoms. The limited accommodation of the convex probe with the fcal-l-1.0 and fcal-2.0 phantoms is a constraint of their designs. The fcal- L-1.0, however, can be easily modified to accommodate the different probes. A calibration error of less than a millimeter was achieved by all three phantoms over numerous trials. The discrepancy between the accuracy and variance of the phantoms is insignificant and can be probably mostly caused by the error of the electromagnetic tracker. It was found that all calibrations are most accurate with the lowest variance when using the linear probe with the optical tracker. This can be attributed to how the optical tracker has greater accuracy than the electromagnetic tracker. The improvement of the accuracy of the calibrations from phantom to phantom may be due to the gain in experience of the operator. This however was discounted when studying varied conditions of calibration as the order of the phantoms tested was changed. Another potential source of error is that different materials were used for the strings of the phantoms. An experiment was done to determine if this would have an effect on the calibration results. It was found that as long as the wires are identifiable and that the ultrasound software is able to segment the image, the calibration results are practically identical. Future experimentation may look to determine a modification to the design of the fcal-l-1.0 with aims of accommodating larger probes and alternative wiring. These designs would then be compared to existing calibration tools to determine if accuracy and variance are compromised with these changes. A compromise of size and accuracy could be an explanation for the fcal-3.1 consistently delivering more inaccurate results than the fcal-2.0 and fcal-l-1.0. The significance of these results is that the fcal-l-1.0 was able to produce calibrations statistically equivalent to calibrations produced by printed N-wire phantoms. There is a potential for error during assembly and for the phantom to come apart as its structure is not fixed, however, the low cost, availability, and modification potential of the LEGO parts, the fcal-l-1.0 may allow for a more accessible calibration option of tracked freehand ultrasound in laboratory experiments and perhaps even in clinical systems. 4. ACKNOWLEDGEMENTS This project has been cosponsored by the Natural Sciences and Engineering Research Council of Canada and Cancer Care Ontario. Marie Soehl was supported by Queen s University Summer Work Experience Program (SWEP). Ryan Walsh was supported by Natural Sciences and Engineering Research Council of Canada. Gabor Fichtinger was funded as a Cancer

Care Ontario Research Chair. LEGO is a trademark of the LEGO Group of companies which does not sponsor, authorize or endorse this research. REFERENCES [1] Mercier, L., Langø, T., Lindseth, F., Collins, L. D., A review of calibration techniques for freehand 3-D ultrasound systems, Ultrasound Medicine & Biology, 31, 143-165 (2005). [2] Chen, T. K., Thurston, A., Ellis, R., Abolmaesumi, P., "A Real-Time Freehand Ultrasound Calibration System with Automatic Accuracy Feedback and Control," Ultrasound in Medicine & Biology, 35(1):79-93, (2009). [3] Carbajal, G., Lasso, A., Gómez, Á., Fichtinger, G., Improving N-Wire Phantom-based Freehand Ultrasound Calibration, International Journal of Computer Assisted Radiology and Surgery, (2013). [4] Walsh, R., Soehl, M., Rankin, A., Lasso, A., Fichtinger, G., Design of tracked ultrasound calibration phantom made of LEGO bricks, SPIE Medical Imaging, MI104 - Image-Guided Procedures, Robotic Interventions, and Modeling, (2014). [5] Guler, O., Yaniv, Z., Image-guided navigation: A cost effective practical introduction using the image-guided surgery toolkit (IGSTK), Annual International Conference of IEEE Engineering in Medicine and Biology Society, 2012:6056-9, (2012).