Safety Switches CES-AR/CET-AR

Similar documents
Safety System CES-FD. Non-contact safety system CES-FD- Direct connection to decentralized peripheral systems (e.g. ET200pro) PLC

Active face 57,5. Series Comment Version Order no. / item. Installation material 8-groove Bosch Installation material for CES-A-BSP

Non-Contact Safety System CES-AZ

Non-Contact Safety System CES-AZ

Safety Switches CES-AR/CET-AR

More than safety. Operating instructions Non-contact safety system CES-A-ABA-01/CES-A-ABA-01B (Unicode)

More than safety. Operating instructions Non-contact safety system CES-A-AEA-02B/CES-A-AEA-04B (Unicode)

More than safety. Operating Instructions Non-Contact Safety Switch CES-AP-CR2-AH (Unicode) CES-AP-CL2-AH (Unicode)

More than safety. Operating Instructions Non-Contact Safety Switch CES-AR-CR2-AH (Unicode) CES-AR-CL2-AH (Unicode)

INDUSTRY. Ongoing dialog. Communication at Industry 4.0 level

More than safety. Operating Instructions Non-Contact Safety Switch CES-AR-C01-EH-SA (Fixcode)

Operating Instructions

Transponder-coded safety switches Interlocking devices and guard locking devices

Operating Instructions

Online data sheet. T40-E0101K T4000 Direct NON-CONTACT SAFETY SWITCHES

Operating Instructions

Interlock Switches. Selection Guide. HS7A-DMC Magnetic Safety Switches

Magnetically Coded Safety Switches CMS

Product Overview Safety Engineering electronic

More than safety. System Manual Safety System MGB-AR in combination with a locking module MGB-L1-AR-.../MGB-L2-AR-...

Datasheet - RSS 36-D-R-ST

Original operating instructions Fail-safe inductive sensor GF711S / / 2013

Non-Contact Safety System CES-AZ

Original operating instructions Fail-safe inductive sensor GI711S / / 2010

Datasheet - MZM 100 B ST2-1P2PW2RE-A

Datasheet - MZM 100 B ST-1P2PW2REM-A

Transponder-coded safety systems with external evaluation

Operating Instructions

System family AR. Transponder-coded safety switch CET.-AR- With guard locking

Datasheet - AZM300Z-ST-1P2P-A

Datasheet - CSS 11-30S-D-M-ST

SR B series coded magnetic safety sensors

Operating Instructions

Safe switching and monitoring Non-Contact Safety Sensors

Transponder-coded. with guard locking

Technical data. Dimensions: see page 116. ): 4 kv Rated insulation voltage (U i Over-voltage category: Power supply. Rated operating voltage (Un):

SR A series coded magnetic safety sensor

Original operating instructions Safety relay with relay outputs G1501S / / 2016

Original operating instructions Safety relay with relay outputs with and without delay G1502S / / 2016

Safety coded magnetic sensor SR A series

Technical Data. General specifications. Rated operating distance s n 3 mm

Safety coded magnetic sensor SR B series

Safety Switches with Separate Actuator, Metal Housing

Datasheet - AZM 200SK-T-1P2PW

Coded magnetic safety sensor SR B series

Safety. Detection. Control. MAGNUS RFID ENG - REV

Non-Contact Safety System CES-AZ

Non-Contact Safety System CMS. Magnetic Coding. More than safety.

Multifunctional Gate Box MGB

Non-Contact Safety Switch CMS. Magnetic Coding. More than safety.

Safety coded magnetic sensor SR B series

Safety coded magnetic sensor SR A series

Thread length (overall length) material

Inductive sensor For rotary actuators NI4-DSU35TC-2Y1X2

Connection of serial wired CES-AR to safety relay ESM-BA..1 Content

Datasheet - SRB 402EM-24V

Technical Data. General specifications Switching element function DC Dual NC Rated operating distance s n 3 mm. Short-circuit protection

The SMART Non-contact Safety Sensor SRF With an innovative diagnostic system

Online data sheet STR1-SASM03P5 STR1 NON-CONTACT SAFETY SWITCHES

Technical Data. Dimensions

Inductive sensor For rotary actuators NI4-DSU35TC-2Y1X2/S933

Datasheet - AZM 200 BZ ST-T-AS P

Online data sheet. TR4-SDM03P TR4 Direct NON-CONTACT SAFETY SWITCHES

Technical data. Housing Polyamide housing PA 66, self-extinguishing V0 acc. to UL 94. Supply Rated supply voltage (U n

ADVANCED ultrasonic sensors with 2 switching outputs. Dimensioned drawing

SensaGuard. Description. Features. Benefits. Specifications

Online data sheet. i10-e0454 Lock i10 Lock SAFETY LOCKING DEVICES

Online data sheet STR1-SAFM03P5 STR1 NON-CONTACT SAFETY SWITCHES

Identification System CIS3A-Mini

Original operating instructions Fail-safe inductive sensor GG711S

Versatile and safe. Transponder-coded safety systems CES

Safety module - PSR-SCP- 24DC/TS/S

Original operating instructions Fail-safe inductive sensor GI712S

Inductive sensor For rotary actuators NI4-DSU35-2Y1X2-H1140

Safety switches for hinged doors

Online data sheet. IN30-E0407K IN3000 Direct NON-CONTACT SAFETY SWITCHES

CM Series. Most Diverse and Flexible Line of Coded Magnetic Safety Interlock Switches and Controllers. Description. Safety Interlock Switches

Technical data. Safety parameters: see page 333. DC maximum residual ripple: 10% Supply voltage tolerance: DC consumption: Control circuit

Specifications. Functional Safety Data Note: For up-to-date information, visit Certifications.

ITEM ESM-BA301

Connection of CES-AR to safety relay ESM-BA..1 Content

Note: KLASCHKA КB WIDENT/P 1/9

Inductive proximity switches with long operating distance, series 500

SALES NUMBER NUMBER OF BEAMS PROTECTIVE HEIGHT

Magnetic Field Sensor Magnetic-inductive Proximity Sensor BIM-M12E-Y1X-H1141

SAFETY RELAY YRB-4EML-31S MAIN FEATURES

Datasheet - SRB 301LC/B-24V

Inductive sensor Dual sensors with extended temperature range NI4-DSU35TC-2Y1X2/S97

System family AP. Safety switch CET.-AP- With guard locking

Inductive sensor BI1.5-EG08-Y1-H1341

Datasheet AZM 161 Z ST1 AS RA

PSEN 4.2a/b/p/M12. PSEN sensor technology. Operating Manual EN-02

Temperature Switches

IB080QM65VA3 Part Number

Safety switches with separate actuator

Operating Instructions

E-STOP relays, safety gate monitors

Magnetic field sensor Magnetic-inductive Proximity Sensor BIM-M12E-Y1X

Safety hinge switches HX series

Inductive dual sensor For rotary actuators NI4-DSU35TC-2Y1X2/S933

Transcription:

CES-A-L XXXXXX Safety Switches Component overview for non-contact safety switches Connection cable Safety switch Actuator Bolt CES-A-BBA Page 1 CES-A-BCA Page 1 Page 10 CES-AR-C01-... Page 10 CES-A-BPA Page 1 Page 177/178 CES-A-BRN Page 1 CES-A-BLN-R2 Page CES--AR-CR2... CES-A-BLN-U2 Page 1 Page CES-A-BDN Page 10 Page 11 CES-A-BLN-L2 - Page 10 CES--AR-CL2... Page CES-A-BLN-U2 Page 1 Page CES-A-BDN Page 11 CET-AR-... CET-A-BWK-0X Page 1 Page 10 Page 12 Page 1 Page 18 17

Usage of the connection cables SPS PLC Connection cable 8-core, flying lead for the connection of a CES-AR-C01 see page 10 CES-AR-C01 # 1 SPS PLC Connection cable 18-pin + PE, flying lead for the connection of a CET-AR see page 1 STATE DIA SPS PLC CES-AR-C.2 # 1 CET-AR # 1 Connection cable 8-core, flying lead for the connection of a CES-AR-C02 see page 10 Connection cable -core, flying lead for the connection of the last device () in a switch chain see page 10 Connection cable -core, connectors at both ends for the connection of two CES-AR-C in a switch chain see page 10 Bridging connector see page 12 Y-distributor M12 see page 12 CES-AR-C01 # n-1 STATE DIA CET-AR # n CES-AR-C.2 # 1 18

Possible combinations for CES components To give you a quick overview of which CES components can be combined with each other, there is a combinations table for each evaluation unit and for each safety switch. The table will answer the following questions: Which actuator can be read by the selected safety switch? What is the operating distance of this combination? Which type of guard locking can be realized with the selected combination? Important: Only typical values are listed in the table. The minimum and maximum values are listed in the technical data for the related product. 1 Combination possible, typ. switch-on distance 1 mm Key to symbols Combination possible, guard locking for process protection Combination possible, guard locking for personal protection Combination not permissible Non-contact safety switches Actuator Safety switch CES-A-BBA 07180 CES-A-BCA 08878 CES-A-BPA 09877 CES-A-BRN 021 CES-A-BLN-R2-077 077 CES-A-BLN-L2- CES-A-BLN-U2-0 0 CES-A-BDN-0-7 7 CET-A-BWK-0X 0927 CES-AR-C01... 18 18 22 27 CES-AR-CR2... 1 1 19 CES-AR-CL2... 1 1 19 CET.-AR... External evaluation unit CES-AR-AES (Which safety switches can be connected?) Evaluation unit Safety switch CES-AR-AES-12 CES-AR-C01... CES-AR-CR2... CES-AR-CL2... CET1-AR-... CET2-AR-... From V 1.1.2 (see rating plate on the device) From V 1.1.2 (see rating plate on the device) 19

Non-contact safety switches CES-AR-C01... Read head with integrated evaluation electronics Up to 20 switches in series Short circuit monitoring 2 safety outputs (semiconductor outputs) Category / PL e acc. to EN ISO 189-1 Non-contact safety switches CES-AR-C01... M12 plug, 8-pin Dimension drawing 20, 0 0, Cat. PLe 1...20 1, For possible combinations see page 19 7 LED indicator Approach direction Can be adjusted in 90 steps M12x1 Short circuit monitoring The switch generates its own clock signal on the output cables OA/OB. Pay attention to this aspect when connecting to control systems and relays. Unicode evaluation Each actuator is unique. The safety switch detects only the actuator that has been taught-in. Additional actuators can be taught-in. Only the last actuator taught-in is detected. Multicode evaluation Every suitable actuator is detected by the safety switch. Fixcode evaluation An actuator CES-A-BPA is permanently allocated to the evaluation unit. The evaluation unit can be operated only with this actuator. The actuator is taught-in at EUCHNER prior to delivery. No additional actuators can be taught-in. Category according to EN ISO 189 1 Due to two redundant design semiconductor outputs (safety outputs) with internal monitoring suitable for: Category / PL e according to EN ISO 189 1 Important: To achieve the stated category in accordance with EN ISO 189 1, both safety outputs (OA and OB) must be evaluated. LED indicator STATE Status LED DIA Diagnostics LED Additional connections OUT Monitoring output (semiconductor) RST Reset input Ordering table Series CES-AR-C01-AH-SA Unicode CES-AR-C01-CH-SA Multicode CES-AR-C01-EH-SA Fixcode (Actuator CES-A-BPA included) Block diagram Connection examples see page 17 Terminal assignment 7 IB 1 Category and PL according to EN ISO 189 1 / PL e / PL e / PL e UB 2 CES-AR OA OB Ø, OUT M12 plug-connector (8-pin) Pin Designation Description Wire color acc. to DIN 70 1 IB Enable input for channel 2 white 2 UB Power supply, DC 2 V brown OA Safety output, channel 1 green OB Safety output, channel 2 yellow OUT Monitoring output gray IA Enable input for channel 1 pink 7 0V Ground, DC 0 V blue 8 RST Reset input red 1 8 2 View of connection side of the safety switch 7 IA 0V 7 RST 8 RST UB 0V IA IB OA OB OUT Order no. 09891 CES-AR-C01-AH-SA 09892 CES-AR-C01-CH-SA 09882 CES-AR-C01-EH-SA For connection cable see page 10 8 2 7 1 10

CES-A-L XXXXXX Safety Switches Typical operating distances Safety switch CES-AR-C01-... Y CES-A-BBA Page 1 CES-A-BCA - 1 20 2 20 1 1 20 2 2 Page 1 X Z - For a side approach direction for the actuator and safety switch, a minimum distance of s = mm must be maintained so that the operating distance of the side lobes is not entered. Y 0 2 20 1 CES-A-BPA Page 1-1 20 2 0 1 20 2 0 X Z - Actuator For a side approach direction for the actuator and safety switch, a minimum distance of s = mm must be maintained so that the operating distance of the side lobes is not entered. Y 0 0 0 0 2 CES-A-BRN Page 1 20 1 20 1 - - 2 X -1 0-20 0 1 20 2-2 Z - - -0 - -0 - -0 - For a side approach direction for the actuator and safety switch, a minimum distance of s = mm must be maintained so that the operating distance of the side lobes is not entered. 11

Technical data non-contact safety switches CES-AR-C01... Parameter Housing material Value min. typ. max. PBT V0 GF Dimensions According to EN 097--2 mm Weight 0.17 kg Ambient temperature at U B = DC 2 V -20 - + C Degree of protection Safety class Degree of contamination Installation position Connection Operating voltage U B (reverse polarity protected, regulated, residual ripple < %) For the approval according to UL the following applies IP7 III Any M12 plug connector, 8-pin Unit 2 ± 1% V DC Operation only with UL Class 2 power supply, or equivalent measures Current consumption 80 ma Switching load according to DC 2 V, class 2 External fuse (operating voltage U B ) 0.2-8 A Classification acc. to EN 097-- PDF-M EMC protection requirements In acc. with EN 097-- Safety outputs (OA/OB, 2 semiconductor outputs, p-switching, short circuit-proof) - Output voltage U(OA/U(OB) 1) HIGH U(OA) U B - 1. - U B HIGH U(OB) U B - 1. - U B V DC LOW U(OA)/U(OB) 0-1 Switching current per safety output 1-00 ma Utilization category according to EN 097--2 DC-1 2 V 00mA Caution: outputs must be protected with a free-wheeling diode in case of inductive loads Off-state current I r 0.2 ma Rated insulation voltage U i - - 0 2) V Rated impulse withstand voltage U imp - - 1. kv Resilience to vibration According to EN 097--2 Switching frequency - - 1 Hz Repeat accuracy R % Monitoring output (OUT) (Semiconductor output, p-switching, short circuit-proof) Output voltage 0.8 x U B - U B V DC Max. load - - 200 ma In combination with actuator CES-A-BBA/CES-A-BCA Operating distance for center offset m = 0 - Switch-on distance - 18 - - Assured switch-on distance s ao ) 1 - - - Switching hysteresis ) 1 - - Assured switch-off distance s ar - - In combination with actuator CES-A-BPA Operating distance for center offset m = 0 - Switch-on distance - 22 ) - - Assured switch-on distance s ao 18 - - - Switching hysteresis ) 1 2 - - Assured switch-off distance s ar - - 8 In combination with actuator CES-A-BRN Operating distance for center offset m = 0 - Switch-on distance - 27 ) - - Assured switch-on distance s ao 20 - - - Switching hysteresis ) - - - Assured switch-off distance s ar - - 7 Reliability values according to EN ISO 189-1 Category Performance Level (PL) PFH d 2.1 x -9 / h ) Mission time 20 years 1) Values at a switching current of 0 ma without taking into account the cable lengths. 2) Tested by employers' liability insurance association (DGUV) up to 7 V. ) Values apply for surface mounting of the actuator. ) On surface mounting on aluminum, in a non-metallic environment the typical switching distance increases to mm. ) In case of surface mounting on steel. ) Applying the limit value from EN ISO 189-1:2008, Section..2 (MTTF d = max. 0 years), the employers' liability insurance association (DGUV) certifies a PFH d of 2.7 x -8. e mm mm mm 12

Actuator CES-A-BBA/CES-A-BCA Rectangular design 2 x 2 mm Actuator CES-A-BBA Actuator CES-A-BCA Housing material PE-HD Dimension drawing 8 2 12 Active face 2 2 ± 0, 2 12 ø, ø8 For possible combinations see page 19 CES-A-B 07180 2 2 1, 8 2 ±0,1, Seal, 2 safety screws Mx1 included 2 safety screws Mx1 included Ordering table Series Comment Version Order no. CES-A-BBA CES-A-BCA 1) Suitable for use in aggressive media (e. g. acids, alkalis) 2 safety screws M x 1 are supplied 2 safety screws M x 1 are supplied Flat seal included - 07180 CES-A-BBA Housing material PE-HD 1) 08878 CES-A-BCA Technical data Parameter Value min. typ. max. Housing material - CES-A-BBA Fortron, reinforced thermoplastic, fully encapsulated - CES-A-BCA Plastic PE-HD without reinforcement, fully encapsulated Flat seal material (CES-A-BCA only) Fluororubber 7 FPM 0 Dimensions 2 x 2 x 12 mm Weight 0.02 kg Ambient temperature - CES-A-BBA -2 - +70 C - CES-A-BCA -2 - +0 Degree of protection Installation position Power supply IP7/IP9K opposite read head Inductive via read head Unit 1

Actuator CES-A-BPA Rectangular design 0 x 0 mm Actuator CES-A-BPA Dimension drawing 0 0-0,2 Ø,2 Active face For possible combinations see page 19 ±0,1 CES-A-BPA-09877 2 safety screws Mx included Ordering table Series Comment Version Order no. CES-A-BPA 2 safety screws M x are supplied - 09877 CES-A-BPA Technical data Value Parameter Unit min. typ. max. Housing material PBT Weight 0.02 kg Degree of protection acc. to IEC 029 IP7/IP9K Ambient temperature -2 - +70 C Installation position opposite read head Power supply Inductive via read head 1

Actuator CES-A-BRN Rectangular design 80 x 0 mm Actuator CES-A-BRN Dimension drawing 0,, 1 8, 17 11 11 80 17 For possible combinations see page 19 Ordering table Series Comment Version Order no. CES-A-BRN 2 safety screws M x 1 are supplied - 021 CES-A-BRN-021 Technical data Value Parameter Unit min. typ. max. Housing material PPS Dimensions 80 x 0 x 1 mm Weight 0.0 kg Ambient temperature -2 - +70 C Degree of protection acc. to EN IEC 029 IP7 Installation position opposite read head Power supply Inductive via read head 1

Non-contact safety switches CES-AR-C.2-... Read head with integrated evaluation electronics Up to 20 switches in series Short circuit monitoring 2 safety outputs (semiconductor outputs) Category / PL e according to EN ISO 189-1 Non-contact safety switches CES-AR-C.2-... Dimension drawing Cat. PLe 1...20 Safety switch CES-AR-CR2-... Fastening lug with reinforcement plate 2 12 9 For possible combinations see page 19 Connection cable with M12 plug connector Length of cable piece: 00 mm With Connection cable 19,,2 11 LEDs 8 +0, STATE DIA, Approach direction For approach directions see illustration "Approach directions and minimum distance" on page 1. Short circuit monitoring The switch generates its own clock signal on the output cables OA/OB. Pay attention to this aspect when connecting to control systems and relays. Safety switch CES-AR-CL2-... Fastening lug with reinforcement plate 2 9 M8x1 12, 7, Unicode evaluation Each actuator is unique. The safety switch detects only the actuator that has been taught-in. Additional actuators can be taught-in. Only the last actuator taught-in is detected., 8 +0, STATE DIA LEDs,2 11 19, With connection cable Connection cable with M12 plug connector Length of cable piece: 00 mm Multicode evaluation Every suitable actuator is detected by the safety switch. 7,, M8x1 For connection cable see page 10 Category according to EN ISO 189 1 Due to two redundant design semiconductor outputs (safety outputs) with internal monitoring suitable for: Category / PL e according to EN ISO 189 1 Important: To achieve the stated category in accordance with EN ISO 189 1, both safety outputs (OA and OB) must be evaluated. LED indicator STATE Status LED DIA Diagnostics LED Terminal assignment Pin Designation Description Wire color acc. to DIN 70 1 IB Enable input for channel 2 white 2 UB Power supply, DC 2 V brown OA Safety output, channel 1 green OB Safety output, channel 2 yellow OUT Monitoring output gray IA Enable input for channel 1 pink 7 0V Ground, DC 0 V blue 8 RST Reset input red Additional connections OUT Monitoring output (semiconductor) RST Reset input For ordering table see page 19. 7 1 8 2 View of connection side of the safety switch RST UB 0V IA IB OA OB OUT 8 2 7 1 1

Typical operating distances Safety switch CES-AR-C.2-... Mounting on plastic Y 0 2 CES-A-BLN... - -2 20 1-20 Actuator Page Page X 1 20-20 - - -1 - -1-1 20 2 Z -2 - - -0 For a side approach direction for the actuator and safety switch, a minimum distance of s = mm must be maintained so that the operating distance of the side lobes is not entered. CES-A-BDN-0 Page 11 Operating distance as for actuator CES-A-BLN... (see above) Attention: The operating distance may vary depending on the background material and installation situation. 17

Technical data non-contact safety switches CES-AR-C.2-... Parameter Housing material Value min. typ. max. PBT V0 GF Dimensions 9 x x 12 mm Weight 0.0 kg Ambient temperature at U B = DC 2 V -20 - + Storage temperature - 20 - + 70 Degree of protection Safety class IP9K (IP7 for version with M12 plug connector) Degree of contamination Installation position Connection Operating voltage U B (reverse polarity protected, regulated, residual ripple < %) For the approval according to UL the following applies III Any Plug connector or connection cable Unit 2 ± 1% V DC Operation only with UL Class 2 power supply, or equivalent measures Current consumption 0 ma Switching load according to DC 2 V, class 2 External fuse (operating voltage U B ) 0.2-1. A EMC protection requirements In acc. with EN 097-- Safety outputs (OA/OB, 2 semiconductor outputs, p-switching, short circuit-proof) - Output voltage U(OA/U(OB) 1) HIGH U(OA) U B - 1. - U B HIGH U(OB) U B - 1. - U B V DC LOW U(OA)/U(OB) 0-1 Switching current per safety output 1-00 ma Utilization category according to EN 097--2 DC-1 2 V 00mA Caution: outputs must be protected with a free-wheeling diode in case of inductive loads Off-state current I r 0.2 ma Classification acc. to EN 097-- Monitoring output (OUT) (Semiconductor output, p-switching, short circuit-proof) - Output voltage 0.8 x U B - U B V DC - Max. load - - 200 ma Rated insulation voltage U i - - 7 V Rated impulse withstand voltage U imp - - 1. kv PDF-M Resilience to vibration According to EN 097--2 Switching frequency - - 1 Hz Repeat accuracy R % In combination with actuator CES-A-BLN... 2) Operating distance for center offset m = 0 - Switch-on distance - 1 - - Assured switch-on distance s ao - - - Switching hysteresis 2) 1 2 - - Assured switch-off distance s ar in x/z direction - - 0 In combination with actuator CES-A-BDN 2) Operating distance for center offset m = 0 in y direction - - 0 - Switch-on distance - 19 - - Assured switch-on distance s ao 1 - - - Switching hysteresis 2) - 2 - - Assured switch-off distance s ar in x/z direction - - 0 Reliability values according to EN ISO 189-1 in y direction - - 0 Category Performance Level (PL) PFH d 1.9 x -9 / h ) Mission time 20 years 1) Values at a switching current of 0 ma without taking into account the cable lengths. 2) The operating distance may vary depending on the background material and installation situation. ) Applying the limit value from EN ISO 189-1:2008, Section..2 (MTTF d = max. 0 years), the employers' liability insurance association certifies a PFH d of 2.7 x -8. e C mm mm 18

Ordering table Series Comment Version Safety switch CES-AR-C.2-AH-... Unicode 2 safety screws M X 1 and reinforcement plates included plug connector M8, 8-pin plug connector M8, 8-pin connection cable PUR, length 1 m, with plug connector M12, 8-pin connection cable PUR, length 1 m, with plug connector M12, 8-pin connection cable PUR, 8 x 0,1 mm², length m connection cable PUR, 8 x 0,1 mm², length m connection cable PUR, 8 x 0,1 mm², length m connection cable PUR, 8 x 0,1 mm², length m connection cable PUR, 8 x 0,1 mm², length 20 m connection cable PUR, 8 x 0,1 mm², length 20 m plug connector M8, 8-pin Order no. / item 71 CES-AR-CR2-AH-SG-71 7 CES-AR-CL2-AH-SG-7 7 CES-AR-CR2-AH-SA-7 78 CES-AR-CL2-AH-SA-78 90 CES-AR-CR2-AH-L0-90 907 CES-AR-CL2-AH-L0-907 900 CES-AR-CR2-AH-L-900 901 CES-AR-CL2-AH-L-901 90 CES-AR-CR2-AH-L20-90 90 CES-AR-CL2-AH-L20-90 70 CES-AR-CR2-CH-SG-70 plug connector M8, 8-pin 72 CES-AR-CL2-CH-SG-72 connection cable PUR, length 1 m, with plug connector M12, 8-pin 7 CES-AR-CR2-CH-SA-7 Safety switch CES-AR-C.2-CH-... Multicode 2 safety screws M X 1 and reinforcement plates included connection cable PUR, length 1 m, with plug connector M12, 8-pin connection cable PUR, 8 x 0,1 mm², length m connection cable PUR, 8 x 0,1 mm², length m 77 CES-AR-CL2-CH-SA-77 90 CES-AR-CR2-CH-L0-90 90 CES-AR-CL2-CH-L0-90 connection cable PUR, 8 x 0,1 mm², length m 908 CES-AR-CR2-CH-L-908 connection cable PUR, 8 x 0,1 mm², length m 909 CES-AR-CL2-CH-L-909 connection cable PUR, 8 x 0,1 mm², length 20 m 902 CES-AR-CR2-CH-L20-902 connection cable PUR, 8 x 0,1 mm², length 20 m 90 CES-AR-CL2-CH-L20-90 19

Actuator CES-A-BLN... Rectangular design x mm and 9 x mm Actuator CES-A-BLN... Dimension drawing CES-A-BLN-R2 CES-A-BLN-U2 7,, For possible combinations see page 19 19, 11 19, 11,2 8 +0, 9 12,,2, 12 Fastening lug with reinforcement plate Fastening lug with reinforcement plate CES-A-BLN-L2 7, 11 19,, 8 +0, 9,2 12 Fastening lug with reinforcement plate Ordering table Series Comment Version Order no./ Article Actuator CES-A-BLN... 2 safety screws M X 1 and reinforcement plates included 9 mm x mm x 12 mm Door hinge right 9 mm x mm x 12 mm Door hinge left mm x mm x 12 mm Usage independent of position of door hinge 077 CES-A-BLN-R2-077 CES-A-BLN-L2-0 CES-A-BLN-U2-0 Technical data Parameter Housing material Dimensions - CES-A-BLN-R2/CES-A-BLN-L2 - CES-A-BLN-U2 Weight - CES-A-BLN-R2/CES-A-BLN-L2 - CES-A-BLN-U2 Value min. typ. max. Plastic PBT 9 x x 12 x x 12 Ambient temperature - 0 - + 70 C Degree of protection according to EN 029 IP7/IP9K Installation position opposite read head Power supply Inductive via read head 0.0 0.02 Unit mm kg

Actuator CES-A-BDN-0 Cylindrical design mm Actuator CES-A-BDN-0 Dimension drawing Installation options For possible combinations see page 19 Ø * min. +0,1,1 0 x * * metal-free zone +0, 2 0 * z y Ordering table Series Comment Version Order no. / item CES-A-BDN-0 7 CES-A-BDN-0-7 Technical data Value Parameter Unit min. typ. max. Housing material Macromelt PA-based plastic Dimensions 2 x mm Weight 0.00 kg Ambient temperature -0 - +70 C Degree of protection IP7 / IP9K 1) Installation position opposite read head Power supply Inductive via read head 1) With flush installation 11