Features Unregulated Converters Industry standard pinout 1kVDC or 2kVDC isolation UL94 V- package material Fully encapsulated Efficiency up to 85% DC/DC Converter Description The DC/DC converters are typically used in general purpose power isolation and voltage matching applications, and feature a full industrial operating temperature range of -4 C to +85 C without derating. 1 Watt SIP4 Single Output Selection Guide Part nom. Input Output Output Efficiency max. Capacitive Number Voltage Voltage Current typ. (1) Load (2) [VDC] [VDC] [ma] [%] [µf] -xx3.3s (3,4) 3.3, 5,12, 15, 24 3.3 33 75 22 -xx5s (3,4) 3.3, 5,12, 15, 24 5 2 78-8 1 -xx9s (3,4) 3.3, 5,12, 15, 24 9 111 78-8 1 -xx12s (3,4) 3.3, 5,12, 15, 24 12 83 8-84 47 -xx15s (3,4) 3.3, 5,12, 15, 24 15 66 8-84 47 -xx24s (3,4) 3.3, 5,12, 15, 24 24 42 78-85 22 Note1: Efficiency is tested at nominal input and full load at +25 C ambient Note2: Max Cap Load is tested at nominal input and full resistive load and is defined as the capacitive load that will allow start up in under 1s without damage to the converter E35885 Model Numbering Input Voltage Output Voltage - S/_ Protection (3) Isolation Option (4) Single IEC695-1 certified EN695-1 certified UL695-1 certified CB Report Note3: standard part is without Continuous Short Circuit Protection add suffix /P for Continuous Short Circuit Protection Note4: add suffix /H for 2kVDC Isolation or add suffix /HP for Continuous Short Circuit Protection and 2kVDC Isolation Ordering Examples: -123.3S/P: 12V Input Voltage, 3.3V Output Voltage, Single Output with continuous short circuit protection -59S/HP: 5V Input Voltage, 9V Output Voltage, Single Output with 2kVDC Isolation and continuous short circuit protection www.recom-power.com REV.: 1/218 ECO-1
BASIC CHARACTERISTICS Parameter Condition Min. Typ. Max. Internal Input Filter Input Voltage Range ±1% Minimum Load (5) % Start-up time Internal Operating Frequency 5kHz 1kHz 15kHz Output Ripple and Noise 2MHz BW 1mVp-p Note5: Operation below 1% load will not harm the converter, but specifications may not be met 25ms capacitor Efficiency vs. Load -xx5s -xx12s 1 1 9 9 8 8 Efficiency [%] 7 6 5 4 Efficiency [%] 7 6 5 4 3 3 2 1 3.35 55 125 2 1 3.312 512 1212 1 2 3 4 5 6 7 8 9 1 1 2 3 4 5 6 7 8 9 1 -xx15s 1 9 8 Efficiency [%] 7 6 5 4 3 2 1 1 2 3 4 5 6 7 8 9 1 3.315 515 1215 www.recom-power.com REV.: 1/218 ECO-2
REGULATIONS Parameter Condition Value Output Accuracy -2% typ. / ±5.% max. Line Regulation low line to high line ±1.2% of 1.% Vin typ. Load Regulation Tolerance Envelope -xx3.3s and -xx5s 1% to 1% load 3.3Vout 5Vout 12, 15, 24Vout -xx12s and -xx15s 2.% max. 15.% max. 1.% max. Output Voltage [%] +1% +7% Vnom Typical Load Line +5% -2% -5% Output Voltage [%] +1% +5% Vnom Typical Load Line +5% -2% -5% 5 1 5 1 Deviation vs. Load 25 -xx5s 25 -xx12s 2 15 3.35 55 125 2 15 3.312 512 1212 Deviation [%] 1 5 Deviation [%] 1 5-5 -5-1 1 2 3 4 5 6 7 8 9 1-1 1 2 3 4 5 6 7 8 9 1 25 -xx15s Deviation [%] 2 15 1 5-5 3.315 515 1215-1 1 2 3 4 5 6 7 8 9 1 www.recom-power.com REV.: 1/218 ECO-3
PTECTIONS Parameter Type Value Short Circuit Protection (SCP) Isolation Voltage (6) Isolation Resistance Isolation Capacitance Insulation Grade I/P to O/P without suffix with suffix /P without suffix with suffix /H tested for 1 second rated for 1 minute tested for 1 second rated for 1 minute Note6: For repeat Hi-Pot testing, reduce the time and/or the test voltage Note7: Refer to local wiring regulations if input over-current protection is also required. Recommended fuse: T1A slow blow type 1 second continuous 1kVDC 5VAC/6Hz 2kVDC 1kVAC/6Hz 1GΩ min. 15pF min. / 12pF max. functional ENVINMENTAL Parameter Condition Value Operating Temperature Range full load (see graph) -4 C to +85 C Maximum Case Temperature Temperature Coefficient Thermal Impedance Operating Altitude +11 C ±.3%/ C Operating Humidity non-condensing 95% RH max. Pollution Degree MTBF Derating Graph according to MIL-HDBK-217F, G.B. 1 9 8 7 6 5 4 3 2 1 +25 C +85 C -4-3 -2-1 1 2 3 4 5 6 7 8 9 1 11 Ambient Temperature [ C] 85 67 C/W 2m PD2 118 x 1 3 hours 48 x 1 3 hours www.recom-power.com REV.: 1/218 ECO-4
SAFETY AND CERTIFICATIONS Certificate Type (Safety) Report / File Number Standard Information Technology Equipment, General Requirements for Safety 16231 Information Technology Equipment, General Requirements for Safety E35885-A4-UL IEC695-1:25, 2nd Edition + A2:213 EN695-1:26 + A2:213 UL695-1, 2nd Edition:27 CAN/CSA C22.2 No. 695-1-3, 2nd Edition:27 Information Technology Equipment, General Requirements for Safety (CB) E32246-A4-CB-1 IEC695-1:25, 2nd Edition EAC RU-AT.49.9571 TP TC 4/211 RoHs 2+ RoHS-211/65/EU + AM-215/863 EMC Compliance Condition Standard / Criterion Information technology equipment - Radio disturbance characteristics - Limits and methods of measurement EMC Filtering Suggestions according to EN5532 L1 with external filter C3 EN5532, Class B EN5532, Class A +V IN +V OUT C1 C2 -V IN -V OUT C4 Component List Class A Model C1 C2 C4 (safety) 3.3, 5, 9Vin 1µF 1nF - 12, 15, 24Vin 1V, MLCC 5V, MLCC 2.2nF, 5KV, Johanson Component List Class B Model L1 C1 C3 (safety) C4(safety) all types 22µH choke RP4532Z-22K 1µF MLCC, 1V 1nF 5KV, Johanson 2.2nF 5KV, Johanson DIMENSION AND PHYSICAL CHARACTERISTICS Parameter Type Value Material Dimension (LxWxH) Weight case potting PCB non-conductive black plastic (UL94 V-) epoxy, (UL94 V-) FR4, (UL94 V-) 11.5 x 6. x 1.mm 1.4g typ. continued on next page www.recom-power.com REV.: 1/218 ECO-5
Dimension Drawing (mm) 11.5 embossed logo 6..51 1.9.51 +.1/-.5 1 2 3 4 Bottom View 1.25 1. 4.1 7.62 Marking 2.54.25 ±.5 Recommended Footprint Details 2.54 Top View 1 2 3 4 Pinning information Pin # Single 1 -Vin 2 +Vin 3 -Vout 4 +Vout Tolerance: xx.x= ±.5mm xx.xx= ±.25mm INSTALLATION AND APPLICATION Typical Application +5V V -512S -Vin +Vin -Vout +Vout Single Board Computer (Raspberry Pi, Arduino, Beaglebone, etc.) +12V Data 12V PIR Senor, IP Camera, etc. PACKAGING INFORMATION Parameter Type Value Packaging Dimension (LxWxH) tube 52. x 16. x 9.mm Packaging Quantity tube 42pcs Storage Temperature Range -55 C to + 125 C Storage Humidity 95% RH max. The product information and specifications may be subject to changes even without prior written notice.the product has been designed for various applications; its suitability lies in the responsibility of each customer. The products are not authorized for use in safety-critical applications without RECOM s explicit written consent. A safety-critical application is an application where a failure may reasonably be expected to endanger or cause loss of life, inflict bodily harm or damage property. The applicant shall indemnify and hold harmless RECOM, its affiliated companies and its representatives against any damage claims in connection with the unauthorized use of RECOM products in such safety-critical applications. www.recom-power.com REV.: 1/218 ECO-6