PR602LCD v1.0 Installer Manual Rev. A

Similar documents
Installation guide for PR302 v2.0 Rev. E

PR402 v2.0 Installer Manual Rev.C

Installation Guide for PR311SE and PR311SE-BK v1.0 Access Controllers Rev. B

Installation guide for PR602LCD type access controller

Installation guide for PR612, PR622, PR312EM, PR312EM-BK, PR312MF and PR312MF-BK access controllers

MCX402DR-BRD I/O expander. Operating Manual

Installation guide for RUD-1 Communication Interface

SL2000E. Status Output. Electronic Code Lock. Features. Input. Exit Button Input. Introduction. Door Contact Input. Functional Description.

RFT1000 reader in RACS 5. User Manual

MCT82M-IO-CH Operating Manual

PRxx1 series controllers Functional Description and Programming Guide

PR402 v1.0 SINGLE DOOR ACCESS CONTROLLER

CRC220 and CRC221 INSTALLATION GUIDE. REF No.: DOC0014 ISSUE: 09

PRT12 v1.2 RFID/PIN Outdoor Access Terminal

DOLXFD1000B. Waterproof Access Control/Reader

PRT12MF-DES, PRT84MF and PRT82MF readers. Operating Manual

Rev B ROGER ACCESS CONTROL SYSTEM

REX F-0-9 Standalone or Access Controller

PRT42 and PRT42-BK Indoor Access Control Terminals Firmware v72.00

F6-Fingerprint. Access Control/Reader. User Manual. F6 - Simplified Instruction. (Master Code) # (Factory default:1234) Enter the Programming Mode

RD-SR2 ACCESS SECURITY PRODUCTS LTD. Proximity Card Reader with Remote Control. User Manual

Two Door Controller GEN-045

S125 Multi-Purpose 125 KHz RFID Reader USER MANUAL. 9V/24V DC Operating Voltage, AC (optional) KHz RFID EM4100/2 Cards & Tags

EL-ST100 KEYPAD CONTROLLER

CV-550SPK V2 Waterproof Keypad/Reader/Controller Installation Instructions

genesis TECHNICAL MANUAL Two-Door Controller GEN-045

DIGITAL DISPLAY. for Industry Applications. Series WAY-SSI. Key-Features:

Stand-alone Proximity Access Control

Buffered Power Supply PS-30DR v1.0

VIDI-AC-2CS Access Controller/ Reader

UNIVERSAL EXPANDER FOR CARD / CHIP READERS INT-R. 1. Features. 2. Installation and start-up

CV-110SPK Standalone Keypad/Prox Access Control Installation Instructions

180 Series Keypad. Handbook. Revision 2.1

Installation and Programming Guide

-DTZ001- Stand-Alone Proximity Access Control. User Manual

SINGLE READER EXPANSION MODULE

Connecting a Cisco Output Module

PRT62 v1.1 Outdoor Access Control Terminal Firmware v74.7

W3-M. Metal waterproof standalone access control/reader. User Manual

RBR-SB-KTZ001 LAR 2. User Manual

1. Product Specification

CM-110SK Standalone Keypad Installation Instructions

Electronic Code Lock. SL2000E v1.1

Standalone Keypad Access Control. User Manual. Please read the manual carefully before use this unit

Waterproof. Keypad/Reader/Controller

PRTxxMF series ISO/IEC 14443A and MIFARE readers. Firmware version: x Document version: Rev. H. This document refers to following products:

Standalone Keypad Access Control. User Manual. SS-TS2000 Size:120*80*25 mm

W3-H Waterproof Keypad/Reader/Controller

ACCESS CONTROL SYSTEM

DG-800 Stand-Alone Proximity Reader Instruction Manual

GV-Card Reader. User s Manual

ACTpro Single Door IP Controller. Operating & Installation Instructions

716 Converter. Programmable Data Converter

Single Door Standalone Access Control User Manual

Keypad CT2000. Art. No.: , (black) Art. No.: , (white) Installation Manual

Quick Start Installation Guide

XT-9100 Technical Bulletin

IB080QM65VA3 Part Number

Access control panel U-Prox IC E (Elevator control)

ImproX IXP20 Controller INSTALLATION MANUAL

GV-EL124S Electric Strike

Installation manual Card reader Sirius i80l(p) o Product o Installation o Connection o Technical data

Digital Keypad Introduction

CV-945 Stand-Alone Biometric Reader. Installation Instructions

Fingerprint Access Control F1. User Manual

Connecting a Cisco Reader Module

Installation manual Card reader Sirius i80(p) o Product o Installation o Connection o Technical data

+GF+ SIGNET ph/orp Transmitter Instructions

D115 The Fast Optimal Servo Amplifier For Brush, Brushless, Voice Coil Servo Motors

Suprex RS-485 SPX-7500 Wired Reader-Extender

OEM Proximity Reader with Keypad Manual REV1

SC500/SC500P. Installation Note

C5S120 Installation and Connection Guide

TCNM-ACBB1 Installation Manual

HSY-S209 EM Metal waterproof access control system User Manual

1 IF-810 or IF-811 Terminal (Slave) 2 Intended Use. 3 Assembly and Installation _V IF-810/IF-811

RXTH DUAL ROOM SENSOR / SWITCH

In-Sight 7010C/7200C/7400C

MPI-DN, MPI-D MULTICHANNEL ELECTRONIC RECORDER for HART or RS-485/ MODBUS RTU SENSORS

F11 Installation Guide. Version: 1.0 Date: Jul. 2010

Integriti 8-32 Zone LAN Expander Module Kit INSTALLATION MANUAL

Hardware Manual CNC760

Neets Control QueBec P/N#: P/N#: User Manual

Connecting a Cisco Input Module

MR52 READER INTERFACE

EasyIO FW 08VUser Reference

6222 Two Door Module Technical Operations Manual

Key Switch. Document version: 1.5 (Updated 02 May 2017)

DORMA. Installation Manual Extension kit I/O module in the B6L 4P

9.5 nominal torque 4.5 W 16 VA. Min. 30 nominal voltage Min. 30 Nm. Reversible with switch By mounting. MIN (minimum position)

HI SEC Integrated Systems

GV-AS Controller. Installation Guide

OFP401P0189. Color Sensor. Operating Instructions

TEC100 USER/INSTALLER MANUAL V2.0 REV. 03/2018

Amano (itrt) Intelligent Twin Reader Terminal INSTALLATION MANUAL

1 IF-812 or IF-815 Terminal (Slave) 2 Intended Use. 3 Assembly and Installation _V IF-812/IF-815

CardaxFT Reader I/O Interface

UC-2000 Installation Manual Unicorn Computers Technology Limited

Suprex Fiber Optic. Reader-Extender SPX-7400 SPX Product Manual. Reader-Extender. Manual. SPX-7400 Series EXP Suprex_FiberOptic_MAN_170502

TB21. NO - Relay. Relay. Common - Relay. NC - Relay. Input J23. Ground TB22 TB23. NO - Relay Common - Relay NC - Relay Input Ground.

Transcription:

PR602LCD v1.0 Installer Manual Rev. A

Introduction This document contents minimum information required for electrical connections and installation of the PR602LCD access controller in Roger Access Control System. The full functional description of this product can be found in General Manual for PRxx2 Access Controllers available on www.roger.pl Note: The PR602LCD requires PR Master v4.2.6.8 or higher. Installation The PR602LCD can be installed either In internal or external locations and doesn t require any additional protection measures. All electrical connections should be work out before power supply will be applied. Factory new unit has ID number set to 00 and has pre-programmed MASTER PIN=1234 and MASTER card delivered with the device. The MASTER card/pin can be use for initial testing of the controller s installation. If the unit has factory setting the single use of card/pin MASTER will activate REL1 output for approximately 4 second while double use of card/pin MASTER will change current arming mode of controller and will switch IO1 output to reverse state. All devices connected to RACS communication bus should have common supply minus (common GND). This can be achieved by connecting all supply minuses with separate wire or connecting every supply minus with earth however this solution might crate problems when electrical potentials of the earth is not the same in different parts of electrical installation. Note: It is forbidden to short positive (+) outputs from different power supply sources used in the access system. Setting address Before controller will be connected to communications bus it should have individual address (ID number=00..99). The controller s address can be set manually during Memory Reset procedure or connecting controller separately (without other controllers) to PC and then changing its address from PR Master program. Note: Connecting two controllers with the same address will cause communications conflict which will corrupt system s behaviour. Power supply Controller requires 10-15V DC power supply which should be connected to +12V (positive) and GND (negative) wires. Also, the GND line operates as reference potential for: inputs, RS485 and Clock/Data interface. Door Lock In most cases the door locks are some kind of solenoid thus they represent inductive impedance. Such type of loads will crate strong voltage pulse when current flown through this element is discontinued. This phenomenal may hung up electronic circuit or changes its behavior. In order to protect system from these effect every inductive load should be protected with silicon diode (e.g. 1N4007) connected in parallel to inductive load and very close to it. The door lock can be supplied from the same power source as electronic modules however it should be wired using separate pair of wires connected directly to power source but not to other electronic equipment connected to it. - 2 -

Inputs Controller offers three inputs (IN1, IN2 and IN3), all of them have the same electric structure and might be configured as NO or NC. Normally, each input is internally biased to supply plus (+12V) through 5.6kΩ resistor. The NO type input can be triggered by shorting it with supply minus (GND). The NC line should be normally tied to GND and will be triggered when connection with GND will be discontinued. Relay output Controller has one relay type output (REL1) which offers one NO/NC/COM contact 24V/1.5A rated. The relay s contact are internally protected with semiconductor components which are dedicated to protect relay s contact from sparks when switch high current. Those components will be damaged when voltage over 30V will be applied to relay s contacts therefore the 24V AC/DC is the maximum voltage level allowed to be applied to relay. When relay output is not triggered (normal state) the NC is shorted with COM, when triggered (active state) NO contact is shorted to COM. When controller is not supplied or supplied with voltage below its minimum level the relay output remains in normal (not triggered) state. Transistor outputs There are two transistor outputs IO1 and IO2, both outputs has identical electrical structure. When not triggered (normal state) transistor outputs represent high impedance, when triggered (active state) outputs short connected potential to supply minus (GDN). Each output can switch max. 1A DC while connected voltage must be 15V DC or less. The IO1/IO2 are internally protected and automatically switch off if current rise above 1A and automatically restore when current drops below 1A. Communication bus The communications bus consist of three lines: A, B and cable s shield (SHLD). Electrically it represents RS485 standard however either the daisy chain structure nor terminating resistors are not required. Free topology of communication bus is allowed, the A/B wires can be laid down using three, star or any combination of them. It is recommended to use UTP cable for A and B lines however other types of signal cables are accepted as well. The use of shielded cables should be limited to those installation were strong electromagnetic interferences are expected. The maximum length of cable between communication interface and individual controller or between CPR32-SE network controller (if installed in system) and individual controller, or between communication interface and CPR32-SE network controller must not exceed 1200m. When longer cable lengths required the UT-3 or UT-4 interfaces can be used. Using two UT-3 unit communication distance can be extended by next 1200m while using UT-4 distance is not limited while UT-4 is connected to any location when computer network is available. - 3 -

Connecting readers and extension modules Access terminals (readers) and extension modules (e.g. XM-2, XM-8) can be connected to controller through CLK and DTA lines. Controller can operate either with Roger access terminals (format RACS) or with any other type of readers which are equipped with Wiegand or Magstripe interfaces. Any type of signal cable can be used for CLK and DTA lines. Each device connected to controller through CLK/DTA lines must have its individual address (0..15) however this rule is not valid for devices which operate with non RACS format (e.g. Wiegand or Magstripe). Note: Normally the maximum guaranteed cable run between controller and any other device connected through CLK/DTA line is limited to 150m nevertheless in most cases communication will be satisfactory for up to 500m however it is not guaranteed. For best card reading results controller should be installed on non metal surface. When installed on metal structure the reading range might be reduced up to 50%. This effect can be reduced by placing non metal spacer (min. 10mm thick) between controller and metal surface. Controller should be installed on at least 0.5m distance from another reader, also both reader should not be aligned along the same geometrical axes. Connecting Wiegand and Magstripe readers Follow schematic drawing below when connecting Wiegand or Magstripe reader to controller. Note, that to prepare the controller for operation with those type of readers you must make relevant setting in PR Master program. - 4 -

Memory Reset The Memory Reset procedure clears all existing data in memory, restores default settings of configuration, enables for enrolment of the new MASTER card/pin and the new ID number (address) of the controller. There are two methods to enter Memory Reset: By means of CLK and DTA line By means of programming jumpers available in rear panel of the controller enclosure The method by use of CLK and DTA lines doesn t requires access to internal space of controller s enclosure. Memory Reset by means of programming jumpers: Put jumper on MEMORY RESET contacts and wait till LED OPEN (green) will start blinking Remove jumper from MEMORY RESET contacts Enter new MASTER PIN and press [#] or if you don t want to program it press [#] key only Read any proximity card - this will be a new MASTER card or press [#} to skip this step Enter two digits (range 00..00) which will program new ID number (address) for the unit After this step Memory Rest will be completed and controller returns to normal operations. Memory Reset by means of CLK and DTA wires: Remove all connections from CLK and DTA lines Short CLK and DTA lines Restart controller (Power off / Power on) Remove connection between CLK and DTA lines, LED OPEN will start blinking Enter new MASTER PIN and press [#] or if you don t want to program it press [#] key only Read any proximity card - this will be a new MASTER card or press [#} to skip this step Enter two digits (range 00..00) which will program new ID number (address) for the unit After this step Memory Reset will be completed and controller returns to normal operations. Once the Memory Rest is completed controller restores Default (Factory) settings, using MASTER PIN/card you can initially test installation while: Single use of MASTER PIN/card triggers REL1 for 4s - 5 -

Double use of MASTER PIN/card changes controller s arming mode and switches IO1 output to opposite state. Firmware upgrade During manufacturing process controller is programmed with latest version of firmware, nevertheless it can be later upgraded with newer versions. Roger design team continuously work on enhancements so the new firmware versions are released quite often (every new firmware version is published on www.roger.pl). Our customers are advised to register at web site so Roger will let inform when new versions are ready for download. The new firmware can be downloaded without removal of the controller from live installation. The detailed description of firmware upgrade procedure can be found in Firmware upgrade.pdf on www.roger.pl. The new firmware is programmed into the controller by means of communication bus and doesn t require de-installation of the unit from its original location. For firmware upgrade the RogerISP v3 program is required. Once the controller is upgraded it should be fully reconfigured, also it is necessary to update the RACS database which must know what is the current version of controller s firmware (command Networks/Controllers/Commands/Restart controller and verify version..). Note: Whenever new firmware is uploaded into the unit the PR Master program should be also upgraded to latest available version. Cable connection assignments Wire colour Name Function Red +12V Power supply plus Black GND Power supply minus, also reference ground for inputs, RS485 and Clock and Data interface Pink IN1 IN1 input, internally pulled to supply plus through 5.6kΩ resistor Blue IN2 IN2 input, internally pulled to supply plus through 5.6kΩ resistor IN3 IN3 input, internally pulled to supply plus through 5.6kΩ resistor Brown RS485 A RS485 communication bus, line A RS485 B RS485 communication bus, line B White CLK Interface RACS Clock & Data, line CLOCK Green DTA Interface RACS Clock & Data, line DATA Whiteyellow Whitegreen Yellowbrown Browngreen IO1 IO2 IO1 transistor output 15V DC/1.0A IO2 transistor output 15V DC/1.0A Violet REL1-NO REL1 output, normally open contact, 24V/1.5A rated Red-blue REL1-COM REL1 output, common contact, 24V/1.5A rated Gray-pink REL1-NC REL1 output, normally closed contact, 24V/1.5A rated Yellow TAMPER A Tamper switch, line A, 24V/50mA rated Gray TAMPER B Tamper switch, line B, 24V/50mA rated - 6 -

Technical specification Supply voltage Current consumption Anti-sabotage Reading distance Cards Distances Environmental class (according to EN 50131-1) 10-15 VDC average 100 ma Isolated contact, NC type, 50mA/24V rated, IP67 UP to 12 cm for ISO card (depends on card type) EM 125 KHz (EM4100/4102 compatible) Between controller and reader or extension module: max. 150 m Between controller and Communications interface or CPR32-SE network controller: 1200m Class IV, Outdoor-General, temperature: -25 C- +60 C, relative humidity: 0 to 95% (non-condensing) Ingress protection IP 65 Dimensions Weight Approvals 170 X 110 X 42 mm ~ 410g CE - 7 -

Ordering information PR602LCD RM-2 RM-2 PCB XM-2 XM-2 PCB UT-2 UT-2USB UT-4 PR602LCD access controller Relay module with plastic enclosure, the RM-2 offers two relays with one NO/NC contact 1.5A/24V rated, relay contacts are protected by over-voltage components, each relay can be triggered by applying supply plus or minus, the maximum amount of current required to trigger relay is less then 5mA, two LEDs to indicate triggering of relevant relay RM-2 PCB module without enclosure Input/output addressable extension module with plastic enclosure, digital communication according to RACS Clock and Data protocol, two NO/NC inputs and two relay outputs, each relay offers one NO/NC contact 1.5A/24V rated, relay contacts protected by over-voltage components, two LEDs to indicate triggering of relevant relay RM-2 PCB module without enclosure RS232-RS485 communication interface USB-RS485 communication interface Ethernet-RS485/RS232 communication interface Contact Roger sp. j. 82-416 Gosciszewo Gosciszewo 59 Tel.: +48 (55) 272 01 32 Fax: +48 (55) 272 01 33 e-mail: biuro@roger.pl - 8 -

- 9 -