This document describes the procedure for doing a power trace on the SM5 and Gauntlet Stepmills.

E3 CNC Router Troubleshooting Guide

E3 CNC Router Troubleshooting Guide

Upgrading to a RBK Control Box

SERIES 5 TABLES/BENCH

Power Cable. Low-Voltage Cable

PoE/FPR Kit for Auto-Sync Time Clock. The Auto-Sync Time Clock is a validated time system with a Web interface and auto discovery.

Lightning Stitch Assembly

apple Service Source Apple Cinema Display 22" LCD (ADC) 11 April Apple Computer, Inc. All rights reserved.

3D SYSTEMS University Cube 3D Printer

Air Hockey v7.0 Controller PCB Air Hockey 10v Transformer

WBS HARDWIRED SERIES 4-60KVA MAINTENANCE BYPASS SWITCH

MCU-9201MT22 venetian blind controller

E1135C PDU and Pod Upgrade Procedure

ABM International, Inc. Lightning Stitch Checklist 9/13/2013

EMC 10T "CE" Mechanical Upgrade Procedure

Open Desktop WorkStation System Components Items Labeled in RED are ESD Sensitive

NEVER operate winch with less than 10 wraps of rope around the drum. The terminal end is to prevent the rope from unraveling, it is NOT a load

Modem Installation and Networking Instructions

Written By: Brett Hartt

Wiring Instructions v3

Samsung NP R580 JBB2 Cooling Fan

SERVICE INSTRUCTIONS CONVERT OLD SFC TO NEW SFC WARNING WARNING WARNING

ROBOT LINE TRACKING MOUSE KIT C-9801

OLPC XO-4 Touch Mouse Buttons Controller Replacement

Treadmill Embedded Touch Screen Won t Power Up

Field Service Procedure Level Cage Motor Kit, XX06, XX06R, XX06RZ, XX06RZA, XX97, XX97A, XX97B, XX00, XX00B & XX07

SERIES 7 TABLES PRE-DECEMBER Troubleshooting Guide. IMPORTANT NOTE: This guide applies to models shipped prior to December 2015 only.

D O O R S T A T I O N W I T H P R O X I M I T Y R E A D E R

Plasma Panel Replacement Guide DU-42PX12X

I/O PCB-R - Replacement

Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment

CHAPTER 3B: ELECTRONIC POWER STEERING

Power connections 3) Power from 2024 to Control box (The valve harness connected) Ground (0V) +24 V. The voltage between pins 1 & 2 in JPT# 123

Removal and Installation8

High Voltage Power Supply (MMPS) - Troubleshooting Guide

Dell Inspiron N4010 Hard Disk Drive

Vector Drive - Troubleshooting Guide

Vector Drive - Troubleshooting Guide

MH Series Troubleshooting Guide: Rough Draft

Troubleshooting Guide for Firecom Intercoms

Preparing for a Docking Drawer Slim Installation To prepare for a successful Docking Drawer Slim installation please ensure that the cable management

Digital Keypad Introduction

Samsung Galaxy Tab Speaker

OLPC XO-4 Touch Touchpad Controller Replacement

To connect the AC adapter:

Integrated electronic controller Type PICO-tronic T1 with bayonet connector

ADSL Loop Extender AER800-24P

REMOVE COVERS. 1. Remove three screws from the Side Panel (L). 2. Slide the Side Panel (L) backward, and raise it to remove from the printer.

Hawk Alarms and Sensor Error Codes

Star Trac Fitness E-ST 5090 Stepper. Install Guide

GILLIG ELECTRIC BUS Diagnostic Software User Guide & Troubleshooting Guide 8A Rev C Last Revised: 3/23/2017

How To Install: C4000 EMV Upgrade Kit

IMPORTANT AS YOU REMOVE THE CONNECTORS LABEL THE CONNECTOR WITH THE NAME OF PLUG WITH THE SHARPIE

G12/G12x USER S MANUAL

Lenovo IdeaTab A1000L Audio Jack

6 Removal and replacement

SPUTNIK MODULAR WEST COAST RANDOM SOURCE MANUAL V.1 WEST COAST RANDOM SOURCE SAMPLE & HOLD FLUCTUATING RANDOM VOLTAGES QUANTIZED RANDOM VOLTAGES

INSTALLATION INSTRUCTIONS

HOPPER HS-2012/2024 HPRO-2012/2024

3D SYSTEMS University CubeX 3D Printer

Pico Amiga ATX power adaptor install guide

2 in 1 LAN Tester and Multimeter Model:

2015 SIMMCONN LABS, LLC. All rights reserved. NewScope-T1 Operation Manual

Installing Keypad and Backplate

Whitebox TM Developer s Guide

CF3000 Dealer Diagnostic Tool Instruction Manual

XS/XY Error Messages. Message (Code) A01. No or Low Battery Voltage Error. Wrong Tape Code or BAUD Rate Error A05

Solid State Control Calibration Procedure MKG Solid State Griddles - All Options

BC-5000 Field Calibration Procedure 55 AMP

the Interactive Catalog

Installation Instructions. Ecast Mojo B75B Motherboard Upgrade Kit Kit #

6 Problem solving. Problem-solving process. Control-panel messages. Understand accessory lights for the 3-bin mailbox and stapler/stacker

Control Box Setup - PRSalpha

E2460GS Oscilloscope Upgrade Kit

Procedure to Install an IO Expansion Cage Assembly in a Maxum II Modular Oven Analyzer

ThinkCentre. Hardware Removal and Replacement Guide Types 8143, 8144, 8146 Types 8422, 8423, 8427

I/O PCB-AC - Replacement

TABLE OF CONTENTS SECTION 1 TABLETOP CONFIGURATION SECTION 2 TABLETOP CONFIGURATION ACCESSORIES SECTION 3 SLIDE CONFIGURATION

MODEL SST3-MV INSTALLATION INSTRUCTIONS FOR FEDERAL MODEL SST3-MV SELECTABLE SIRENTONE-MULTI VOLT

TD-700 FLUOROMETER SERVICE MANUAL

Scritto Da: Valentina Cerruty

TELIKOU Intercom System. FM Wire Matrix Control Station. Instruction Manual

Ø 11,4 21,5. M9 x 0,5 Ø 12 Ø 11,4. M9 x 0,5 Ø 12. M9 x 0,5

Wiring Instructions. Gatekeeper h4.0. Technical Support.

Models RST 5.6 RCT 7.6

Perform general SC916 electrical testing. With external power removed, step on one or both of the pedal arms

The GENIE Light Kit is ideal for introducing simple lighting projects, such as an electronic die, a wearable badge or a night-time warning system.

TDM To MiniMech conversion ProceDure

16Hi HARDWARE INSTALLATION GUIDE

HOW TO REPLACE A PARKER INVERTER DRIVE WITH A YASKAWA V1000 INVERTER DRIVE

Owner s s Manual. G5 SATA Double Drive Internal Mounting Kit. Apple Macintosh G5. Add 2 SATA drives to the G5

HP CP6015/CM6030/CM6040MFP Remove and Shake Black or Color Cartridges" or " , " Error Messages

Kit K Instructions. V8700 to Alpha Conversion Instructions

Hardware Replacement Guide Lenovo 3000 J Series. Types 8453, 8454, 8455, 8458, 8459, 8460

SERIES 7/9 TABLES & SERIES 8 BENCH. Troubleshooting Guide

Arecont Vision MegaView TM Installation Manual

PLCMTR Commercial Grade Camera System

NewScope-T0 Operation Manual

Hardware Replacement Guide

Transcription:

X/Y Issues on ASP-645-1 Issues seen with X or Y problems: A) Table will not move in X or Y when you are using the Frame Arrow buttons on the control panel. B) On power up the control panel gives Error 21. C) Loud Noise coming from the Pantograph movement. D) On tracing a design on the machine, pantograph only moves in X or only in Y and then gives Error: 1) X-Motor Drive Error 8 2) Y-Motor Drive Error 9 Understanding the possible cause of the problem: Components that may be causing the Issue are: 1) Loose connections on X or Y Driver Boards 2) Loose connection on MPU PCB board. 3) Bad MPU PCB Board. 4) Bad J2 or J3 Cable on MPU PCB Board J2 = X - Step Driver J3 = Y - Step Driver 5) Bad X or Y Board

Confirm X Board or Y Board Issue by looking at the LED light on both boards, with no issue they should be green, problem is seen with Red light on either board. Diagnosing the Possible causes: 1) Checking for loose connections on the X or Y Driver Boards and the MPU PCB board J2 and J3 Connections. Remove the table from the machine. A) Power Off Machine and Unplug from wall outlet B) Remove all Flat Phillip Screws from Table C) Remove the Back Plate screws. D) Slide table off the machine from the front.

Locate the X and Y Driver boards at the rear of the machine: Check & Reseat Loose Connections on the MPU PCB Board:

Check and Reseat Connections on Main Power Board: Turn power back on and test machine X and Y movement using the Frame Arrow buttons on the control Panel. If not working move on to next step. 2) Testing for possible malfunctioning MPU PCB board or Cable. *Power off Machine and Unplug from wall outlet* A) Locate the MPU PCB Board and Swap Connection J2 to J3.

Power on the machine and Move the table by hand left and right for testing X, and Front to back for testing Y. With power to the machine and the machine powered on, the motors receive voltage and lock and you should not be able to move table easily by hand. Diagnosing the issue with Y Axis after Swapping the J2 and J3 Connections 1) If table can still be moved easily by hand front to back but not left to right then the cause of the issue is Malfunctioning MPU PCB board 2) If you cannot move the Table front to back (Y direction) but can move the table left to right (X direction) then issue is bad J3 Cable. 3) If you can move the table easily in both X and Y direction with power on, then the issue is both Malfunctioning MPU PCB board and J3 Cable. Diagnosing the issue with Y Axis after Swapping the J2 and J3 Connections 1) If table can still be moved easily by Left to Right but Not Front to back, then the cause of the issue is Malfunctioning MPU PCB board 2) If you can move the Table front to back (Y direction) but cannot move the table left to right (X direction) then issue is bad J2 Cable. 3) If you can move the table easily in both X and Y direction with power on, then the issue is both Malfunctioning MPU PCB board and J3 Cable. 4) Testing the Motor with Multi Meter: If there is no Red light on either board but table still does not move when using frame arrow buttons on the control panel, or when power is on the machine, the table is easily moved in X only or Y only by hand, then the issue can be: 1) Broken or disconnected X or Y Belt 2) X or Y Motor malfunctioning. For inspection of the X and Y belt can be done visually with wooden cover table removed, if belt is broken or not connected to the motor call Service at 877-793-3278 for technical help reinstalling it or replacing it.

Checking the motor with Multi Meter to prove its condition: Set you Multi Meter to Checking resistance (Ohms) (Follow instructions that came with your meter) 1) Locate the X or Y motor connection and disconnect it. 2) Insert your Black Probe from multi meter into the front of the connector and meter across the colored wires as noted below. Red Wire to Blue Wire = 2.6-3.0 ohms Red Wire to Yellow Wire = 2.6 3.0 ohms Red Wire to Brown Wire = 2.6 3.0 ohms Blue Wire to Yellow Wire = open Blue Wire to Brown Wire = open Yellow Wire to Brown Wire = open If your readings are different than what is shown above then the Motor is malfunctioned and needs to be replaced.