Operating Instructions for Vibrating Level Switches. Model: NVI

Similar documents
Operating Instructions for Level Switch for Liquids. Model: RFS

Operating Instructions for Digital Thermometers. Model: DTM

Operating Instructions for Differential Pressure Sensor. Model: PMP

Operating Instructions for Low Volume Rotating Vane Flow Meter. Model: DTK

Operating Instructions for Low Volume Rotating Vane Flow Meter. Model: DPL-1P... DPL-1V... DPL-1E...

Operating Instructions for Low Volume Rotating Vane Flow Meter. Model: DPL-1P... DPL-1V... DPL-1E...

Operating Instructions for Rotating Vane Flow Meter. Model: DRH-...

Operating Instruction for rotating vane flow meter Model: DPM-...

Operating Instruction for Rotating Vane Flow Meter. Model: DRG-...

Operating Instruction for Turbine-wheel Flow Meter. Model: DRS

Operating Instructions. Isolation Relay for Switches Model: RL manual_rl-6100_1116

Operating Instructions. Power Supply & Isolation Relay for Switches Model: RL manual_rl-5900_0215

Operating Instruction for Turbine-wheel Flow Meter. Model: DRB-...

Operating Instructions for Turbine Wheel Flow Meter. Model: TUR

Operating Instructions. Power Supply & Latching Relay For Switches Model: RL manual_rl-6000_1016

Operating Instructions. Intrinsically Safe Isolation Relay for Switches Model: REL manual_rel-6_0505

Operating Instructions for Evaluation Electronics. Model: ZED-K and DF- KLxxx

Operating Instructions for Hand-held Conductivity Measuring Units. Model: HND-C110

MSR Level Control Relay Module Operating Instructions for Level Control Relay Module Model: MSR

Operating Instructions. For. Level Control Module. Model SSR 1000

Installation manual plugs and connectors with screw connection (16/32 A)

STR-3 STANDARD 3-PHASE 230 VAC TRANSFORMER CONTROLLER. Mounting and operating instructions

English. Operating Manual. Conductive point level switch MLR120. Retain for later reference. Companies / brands of GHM

NIVOSWITCH VIBRATING FORK LEVEL SWITCHES

PRODUCT SPECIFICATION. PC Board Relays. Series.

Masterswitch 25kW 230V-125A Automatic AC transfer switch

VISY-Output 8. Technical Documentation. 8-Channel relay output module. Version: 3 Edition: Art. no.:

Operating Instructions for Turbine Wheel Flow Meter Model: TUR

TECHNICAL INFORMATION Vibracon LVL-B1, LVL-B2

HITACHI. EH-150 series PLC EH-RTD8 Resistance Temperature Detective input module Instruction manual. Safety precautions

HST -M2 Switching element with locking mechanism (Translation of Original Manual)

3/4 U CPCI Serial Case System

FOR LIQUIDS AND SOLIDS

Product manual plug, sockets and coupler 16 A.- Z0251

RE17LAMW on-delay timing relay - 1 s..100 h V AC/DC - solid state output

Operating instructions. Standstill monitor A / / 2011

Operating Instructions VEGAMET 381

Installation, Operation & Maintenance Instructions / Technical Document

Ultra Slim Relays 24

Operating Instructions (Translation) 3. Safety Information. 1. Description. 2. Explosion Protection. Supply module Type 17-21BB-170x

Operating Instructions

Operating Manual. Guardian Series Safety Compliant Melt Pressure Transducer

Electronic Temperature Controller. Instruction Manual Version

Signal processor MS96 for flow sensors MS96-11EX0-R/230VAC

Redundancy unit CP-A RU

Operating Instruction

MSI-RM2 Safety Relays

PTB 01 ATEX 2064 U, IECEx PTB U. Example / Beispiel / Exemple: Type Operating Instructions

MC 11 EB-2 Power supply cabinet with external bus, AC version

CPCI System Subrack 1 U

Operating Instructions for Counter Electronic Model: ZED-Z. or DF- ZLxxx or Model- ExxR

HST -M1 Switching element with locking mechanism (Translation of Original Manual)

RE17LAMW on-delay timing relay - 1 s..100 h V AC/ DC - solid state output

Conductive Level Controller

TRIO-DIODE/12-24DC/2X10/1X20

USER MANUAL VIBRATION CONTROL RMA-POWER-BOX 107/230

Operating Manual / IEC. Explosion-Proofed Junction Boxes, Polyester. Wallücker Bahndamm 7 DE Kirchlengern

RE17LCBM off-delay timing relay - control - 1 s..100 h V - solid state output

Safety Switching Devices SNO 4003K. Basic device for Emergency-Stop and Safety Gate Applications PI E

CNVT-USB-RS485 MODBUS TO USB CONVERTER. Operating instructions

Solid State Relays with Failure Detection Function

FlowJam Plus. Superior with Solids. Material flow monitor with blockage detector. Operating instructions

3+1 U CPCI Serial System

RM22LA32MR Level control relay RM22-L V AC/DC - 2 C/O

REDUNDANCY MODULE TSP-REM360 AND TSP-REM600

G3PC. Model Number Structure. Solid State Relays with Failure Detection Function. Model Number Legend

RТTH DUAL ROOM SWITCH

RE48ATM12MW on-delay timing relay s..300 h V AC - 2 OC

MAXIMA+ Series Rotary Level Indicator

PKP Prozessmesstechnik GmbH. Borsigstrasse 24. D Wiesbaden-Nordenstadt. Tel: / Fax: / Operating manual PSA06

RTT2 ROOM TEMPERATURE SWITCH. Mounting and operating instructions

TERMOREG industrial automation CZ PRUSANKY 352, Czech republic tel.: , fax:

DSTHM-2 COMBINED T AND RH DUCT TRANSMITTER. Mounting and operating instructions

B63/ NS MS. EtherNet/IP LINK

LS 5000 series Vibration Level Switch for liquids

HST -S1 Switching element (Translation of Original Manual)

MAXIMA + Series ROTARY LEVEL CONTROL

Operation Manual. Capacitor Boxes adjustable 80 A / 125 A Track, 2,04 μf to 8 μf. Order Number

PHOENIX CONTACT - 08/2009. Features. DANGER OF EXPLOSION! Only remove equipment when it is disconnected and not in the potentially explosive area.

HST -TZ1 Guard-locking mechanism (Translation of Original Manual)

PHOENIX CONTACT - 01/2010. Features. DANGER OF EXPLOSION! Only remove equipment when it is disconnected and not in the potentially explosive area.

Installation instructions Inclination sensor EC2019 EC / / 2013

crio PN Installation Instructions V0.2/ COMSOFT

RAD-DOR4-IFS. I/O extension module, 4 digital relay outputs. INTERFACE Data sheet. 1 Description

User manual Technical parameters

PCT2000. User Manual. Precision current transducer 2000 A

Operating instructions Hinge safety switch TV.S 335 TV.S About this document. Content

Power supply CP-C 24/5.0

QUINT-BUFFER/24DC/24DC/40

USER MANUAL. WBV412U01 AC voltage transducer

Model Number Structure

english S-5EC Potentiometer 5-step Operating Instructions Keep for reference! L-BAL-E265-GB 1608 Index 002

SINUS PENTA 6. ACCESSORIES 6.1. BRAKING RESISTORS APPLICATION TABLES 111/209

Installation- and Operating instructions for CU Port USB 3.0 Hub. Version: 1.1 Date:

Capacitance level switches LS 210 LS 220

PSR-MS60. Safety relay for emergency stop, safety door and light grid monitoring. Data sheet. 1 Description

PTB 01 ATEX Example / Beispiel / Exemple. Type Operating Instructions

LS 6600 Technical Datasheet

dv/dt filter compact plus Voltage Peak Limiter SINAMICS SINAMICS G120P dv/dt filter compact plus Voltage Peak Limiter Safety information 1 General 2

Operating Manual -ENGLISH- Page 1 KWG-ISO

Transcription:

Operating Instructions for Vibrating Level Switches Model: NVI

1. Contents 1. Contents... 2 2. Note... 3 3. Instrument Inspection... 3 4. Regulation Use... 3 5. Operating Principle... 4 6. Mechanical Connection... 4 7. Electrical Connection... 7 7.1 General... 7 7.2 Operation Diagram... 8 8. Commissioning... 8 8.1 Density (Sensitivity) Adjustment (Switch A)... 8 8.2 High/Low Fail-Safe Mode (Switch C)... 9 8.3 Time Delay (Switch B)... 9 9. Technical Information... 9 10. Derating Diagram... 10 11. Order Codes... 10 12. Maintenance... 10 13. Storage... 10 14. Guarantee... 11 15. Dimensions... 11 16. Declaration of Conformance... 12 Manufactured and sold by: Kobold Messring GmbH Nordring 22-24 D-65719 Hofheim Tel.: +49(0)6192-2990 Fax: +49(0)6192-23398 E-Mail: info.de@kobold.com Internet: www.kobold.com page 2 NVI K02/0812

2. Note Please read these operating instructions before unpacking and putting the unit into operation. Follow the instructions precisely as described herein. The devices are only to be used, maintained and serviced by persons familiar with these operating instructions and in accordance with local regulations applying to Health & Safety and prevention of accidents. When used in machines, the measuring unit should be used only when the machines fulfil the EWG-machine guidelines. 3. Instrument Inspection Instruments are inspected before shipping and sent out in perfect condition. Should damage to a device be visible, we recommend a thorough inspection of the delivery packaging. In case of damage, please inform your parcel service / forwarding agent immediately, since they are responsible for damages during transit. Scope of delivery: The standard delivery includes: Vibrating Level Switch model NVI Operating Instructions 4. Regulation Use Any use of the Vibrating Level Switch, model: NVI, which exceeds the manufacturers specification may invalidate its warranty. Therefore any resulting damage is not the responsibility of the manufacturer. The user assumes all risk for such usage. NVI K02/0812 page 3

5. Operating Principle The KOBOLD NVI level switch is a mechanical system that is made to resonate by an electronic switching operation. When the probe is covered by a medium, the vibrations are damped. This change in the resonance frequency is converted to a switching signal by electronic means. The combined vibrating switch can be used in powdery media and granular materials. The medium to be measured should have a density of at least 0.05 kg/dm3. The single rod design prevents deposit formation. The rod is selfcleaning, as the vibrations shake off the medium. 6. Mechanical Connection Important! Handle the device with great care, especially the sensing probe. A larger impact on the sensing probe may ruin its resonance system. Probes exposed to falling material or mechanical loads should be protected. Prior to the installation, it is advised to test the switching function of the unit on a sample quantity of material and to set Density switch according to the density of medium. (see 8. Commissioning) Screw in the device by its hexagon neck. After screwing tight the process connection, the housing can be rotated (max. 300 ), to adjust the cable glands to the required position. In some cases such as material caving or arching you will need to mount the vibration rod at a clearance from the desired limit. The model NVI is not suggested to be used for low level detection in high density materials. page 4 NVI K02/0812

Max. switching Min. switching Powder Granulate Limits for bending or pulling force and torque should be considered: F RKH- = 445 N M RHH- = 85 Nm RKN- RHN- NVI K02/0812 page 5

Probes exposed to falling material or mechanical loads should be protected. L30x30x3 When working with powdery bulk materials you should install the device at an inclination greater than the existing angle of repose, or even vertically to detect maximum level. This is necessary in order to prevent too much powder clinging to the vibration rod and hindering vibration and self-cleaning of the rod when the silo/tank is being emptied. Avoid mounting the device as shown in the diagram. Use rubber shims for example to protect the device in bins/silos where large vibrations occur. page 6 NVI K02/0812

7. Electrical Connection 7.1 General Attention! Check that the electrical power supply to the instrument complies with the operating data for the instrument. AC = Switch rating acc. To EN60947-1 Status LED A B C 250VAC 8A/AC1 N L1 1 2 3 4 5 6 N L1 NO C NC PE PE Relay output version Attention! Incorrect wiring will lead to damage of the unit s electronics. NVI K02/0812 page 7

7.2 Operation Diagram 8. Commissioning Unscrew the housing cover to access the terminals and setting switches. Do not disconnect the wire from terminal connection point 1. Ground the device at terminal PE or use the grounding screw on the device. When you have properly connected the device, it is ready for operation. The LED lights up when the device is switched on. 8.1 Density (Sensitivity) Adjustment (Switch A) The DIP-Switch DENSITY (switch A) needs to be set to suit the material density. LOW position, recommended for loose and light materials with density around and below 0.1 kg/dm³ represents low energy and amplitude of vibration as well as great sensitivity of detection. HIGH position, recommended for (thick and heavy) materials with density over 0.1 kg/dm³ represents vibration with high energy and amplitude and small sensitivity of detection. page 8 NVI K02/0812

8.2 High/Low Fail-Safe Mode (Switch C) De-energised status of the relay is preferred to be used for fail-safe alarm, thus a power breakdown will be considered as alarm (see 7.2 Operation Diagram) 8.3 Time Delay (Switch B) Though the density of the medium is within the specific range, the device may not detect if the internal friction of the medium is too low. Choose a switch delay (switch B) to suit process requirements (standard response time, switch delay = 5 s; short response time, switch delay = 2 s). Note: The device can be damaged by electrostatic discharge (e.s.d.) from the DIP switch. To prevent such damage, the general precautions must be strictly observed. 9. Technical Information Probe length: 207 mm (standard) extended version on request Process connection: G 1 1/2 or 1 1/2 NPT Housing material: aluminium, powder coated Material for wetted parts: 1.4571 (AISI316Ti) Sensor surface: bright Medium temperature: - 30 C to + 110 C standard - 30 C to + 160 C high-temperature Ambient temperature: - 30 C to + 60 C Maximum pressure: 25 bar Minimum density of medium: 0.05 kg/dm³ Max. grain size: 10 mm Max load: Force: 500 N Torque: 100 Nm Response time: < 1.8 s or 5 ± 1.5 s (selectable) With covered electrode < 2 s or 5 ± 1.5 s With non covered electrode Output: changeover contact 250 V AC /8 A Power supply: 20...255 V AC/DC ; 2.5 VA/2 W Electrical connection: 2xM20x1.5 Protection: IP 67 Weight: approx. 1.9 kg NVI K02/0812 page 9

10. Derating Diagram TA [ C] 60 50 35 20 0-30 0 50 75 100 110 160 T M [ C] -30 Ambient temperature (T A ) versus medium temperature (T M ) 11. Order Codes Example: NVI-1 300 R Model Version Power supply Connection NVI- 1 = Standard R = G 1 ½ 305 = 20...250 V AC/DC 2 = High-temperature 2 = 1 ½ NPT 12. Maintenance Series NVI devices require no regular maintenance. You may need to remove product stuck to the probe and clean the probe every now and then. Handle the sensing probe with great care to avoid any damage. The manufacturer will carry out all repairs within and beyond the guarantee period. Clean or disinfect all parts before returning them for repair. 13. Storage Ambient temperature: -35 up to +60 C Relative humidity: max. 98 % page 10 NVI K02/0812

14. Guarantee All guarantee repair work will be carried out in the manufacturer's workshop. The costs of demounting, installation, and transportation shall be borne by the purchaser. All rights to claims under guarantee for faults caused by incorrect installation, rupture, improper handling or force majeure will not be honoured. 15. Dimensions NVI K02/0812 page 11

16. Declaration of Conformance We, Kobold Messring GmbH, Hofheim-Ts, Germany, declare under our sole responsibility that the product: Vibrating Level Switches Model: NVI to which this declaration relates is in conformity with the standards noted below: DIN EN 61010-1 1993/A2 1995 EN 50081-1 1992 EN 50081-2 1993 EN 50082-2 1997 EN 55022 1994 IEC 61000-4-2 1995/ A1 1998/ A2 2000 IEC 61000-4-3 1995/ A1 1998/ A2 2000 IEC 61000-4-4 1995/ A1 2000 IEC 61000-4-5 1995/ A1 2000 IEC 61326 1997/ A1 1998 Also the following EWG guidelines are fulfilled: 2004/108/EG 2006/95/EC Electro Magnetive Compatibility Low Voltage Directive Hofheim, 17. March. 2011 H. Peters M. Wenzel General Manager Proxy Holder page 12 NVI K02/0812