DC Outdoor Power Supply/Chargers

Similar documents
AL168 Series Multi-Output Power Supplies

Expandable Power Systems

3-Port Ethernet over Fiber PoE+ Hardened Switches Installation Guide

4-Port Ethernet over Fiber PoE+ Hardened Switches Installation Guide

8-Port Ethernet over Fiber PoE Hardened Switches Installation Manual

Rack Mount Power Supplies

Active UTP Transceiver Hub with Integral Isolated Camera Power

Passive UTP Transceiver Hub Installation Guide

Active UTP Transceiver Hub with Integral Camera Power Installation Guide

Transceiver Hub with Integral Camera Power

Passive UTP Transceiver Hub with Integral Camera Power Installation Guide

Active UTP Transceiver Hub with Integral Camera Power Installation Guide

Active UTP Transceiver Hub with Integral Isolated Camera Power Installation Guide

Passive UTP Transceiver Hub with Integral Isolated Camera Power Installation Guide

NetWay1DWP - Outdoor Single Port Hi-PoE Injector NetWay1DWPM - Outdoor Managed Single Hi-PoE Injector I.T.E. 43KC

Installation Guide Versatile Access Power and Integration Enclosures

Installation Guide. Versatile Access Power and Integration Enclosures. Trove2M2 - Trove2 enclosure with Altronix/Mercury backplane

PoE Managed Midspan Solution for Standard Network Infrastructure

Network Power Distribution Module

FC-29W 9 UN-UNIVERSAL Dome Housing. Installation Instructions

Access & Power Integration Solutions

1 Description. 2 Specifications. Product Installation Document. Honeywell 12 Clintonville Road Northford, CT

Model HM-535 Power Supply Installation and Service Instructions

ZC-OH5 TAMPER-RESISTANT INDOOR/OUTDOOR HOUSING INSTRUCTION MANUAL FOR USE WITH GANZ ZC-D5000 SERIES MINIDOME CAMERAS

SPECTRUM. Merging infrastructure with emerging technology.

Rhino Buffer Module PSM24-BFM600S. Operating Instructions

60W Power over Ethernet Waterproof Adapter PoE IEEE BT Single Port Injector for Outdoor Application

TSP-BCM48, TSP-BCM48A. Operating Instruction Manual. Page 1 of 13

5 B&W Rear View System Camera

C-POWER AC AUTOMATIC CONTROL

Ethernet/Network Communications Module. Installation and Programming Manual. LINQ2 - Two (2) Port Connectivity Module. More than just power.

Outdoor Housing PIH-5063/5064/5067 INSTRUCTION MANUAL

Power-Over-Ethernet (PoE) Weatherproof 14 x12 x7 Enclosure with Mounting Plate and Cooling Fan. Model: NB F. Applications and Features

MBE Mounts and Adapters

MAXIMA+ Series Rotary Level Indicator

Magnetically Actuated Safety Interlock Switches

REDUNDANCY MODULE TSP-REM360 AND TSP-REM600

Power-Over-Ethernet Weatherproof 18" x 16" x 8" Enclosure with Equipment Mounting Plate and Cooling Fans

MAXIMA + Series ROTARY LEVEL CONTROL

Installation/ Operation Manual

DIMENSION/WEIGHT kpa. 0 to 20 m / 0 to 60 ft 0 to 2 bar / 0 to 29 psi. 0 to 50 m / 0 to 160 ft 0 to 5 bar / 0 to 72.5 psi

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

HDMI 1x2 Splitter B-230-HDSPLTR-1x2 INSTALLATION MANUAL HDMI OUT 2 HDMI OUT 1 B-230-HDSPLTR-1X2 POWER HDMI IN

Features: S98-B v1.0 S98-B 9-port switch with buffer power supply for 8 IP cameras

LVN5200A-R2, rev. 1, Hardware Installation Guide

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

Chameleon Stand-alone

Model HU-224/225. Technical Information TI.224/ Humidity Transduce r FOR ADDITIONAL INFORMATION SEE HU-224/225 DATA SHEET

Digital I/O Module. Impro (DIO) Digital I/O Module INSTALLATION MANUAL

XDBKITS5 Bus / DB Terminal Kit (Size 5) Installation Manual DPD00116

Andover Continuum. Power Supplies with or without UPS

Power-Over-Ethernet (PoE) Weatherproof 14 x12 x7 Enclosure with Mounting Plate. Model: NB Applications and Features

7 LCD CCTV Test monitor. Quick guide

POE084824B. PoE 54V/8x0,3A/4x7Ah PoE buffer power supply for up to 8 IP camera. v.1.1 EN* Edition: 7 from

Panel Enclosures. Wall-Mount Enclosures Type 12 Premier Series Double-Door with Quarter-Turn Latches Data Sheet

Beacon Power Supply Operating and Installation Instruction Manual

MODEL SST3-MV INSTALLATION INSTRUCTIONS FOR FEDERAL MODEL SST3-MV SELECTABLE SIRENTONE-MULTI VOLT

H704-42(H)(E), H704-42/1(H)(E)

Altivar 61/71 Adjustable Speed Drives Heatsink Fan Kits VZ3V1212 and VZ3V1216

USP-070-B08 USP-104-B10, USP-104-M10 USP-156-B10

hp uninterruptible power system r12000 xr models installation instructions

INSTRUCTION MANUAL. Security Camera. Indoor/Outdoor Color Camera w/ Night Vision. Version 1.0. now you can see. Model# VU5

Daily use. indicating that the loud speakers

Mechanically Activated Device for Dry Run Protection in Applications with LORENTZ Solar Pump Systems

SP-1800 OWNERS MANUAL

Safety switches with separate actuator

Site Preparation CHAPTER

TVA2.1 2-Channel Digital Amplifier Installation Manual

33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application

Rhino Redundancy Module PSM24-REM360S. Operating Instructions

Instruction Manual. M Pump Motor Controller. For file reference, please record the following data:

VLT Line Filter MCC 107 EMC Filter Series VLT Midi Drive FC 280 (K1 K3)

Page Housing Plastic Metal Mounting DIN Rail or surface mount Panel or bracket mount Wattage Range 10W to 240W 7.5W to 240W 10W to 300W

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

Safety switches for hinged doors

Installation Job Aid for Ethernet Routing Switch 5900 Series

3630P Encl 34X28 Enclosure Panel. Features. Material, Color, and Finish. Dimensions and Weight. Descriptions

INSTALL INSTRUCTIONS RSXMR-9886-P-48

SITOP power supply. Selectivity modules. Overview. Safety notes. Description, device design, dimension drawing. Mounting/removal 3

*Approved by CSA for non-hazardous locations (Group Safety Publication IEC Third Edition).

OPLC Installation Guide

Illustrated Parts List MODEL. Reproduction Not for. 8,000 Watt Generator Systems

TRC-190 User s Manual

OWNER S MANUAL SINGLE CAT5E/6 3D EXTENDER B-320-1CAT-HDIR

System Components Surge Arrester HAW 261 and HAW 262

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

SITRANS F. Flowmeters SysCom Upgrade Kit IP65 (NEMA 4X) Multi-Channel. Introduction 1. Installing/Mounting 2. Hardware Installation Instructions

AGATA C200 UK A/200N TARGHA 200. Installation Manual AGATAKIT C 200 UK

Installation Guide. Rev

Industrial Camera GP-MF602. Before attempting to connect or operate this product, please read these instructions completely.

User Guide CPSMP VAC Power Supply Module: PointSystem CPSMC Accessory CPSMC Accessory. Contents.

CABINETS & ENCLOSURES FOR PREPAYMENT METERS

HydroGuard 4 to 20 ma Output Module. For use with HydroGuard Water Quality Monitor and Controller

Quick Start Guide. Preparation. Installation. Operation. Support. Vaisala NOMAD 3 Data Logger. Online manuals

long range ethernet Extend Ethernet range 5x the distance - without repeaters. Long Range Ethernet Adapters Features:

TYPE 4/12 PREMIER SERIES

IRB-RET O P E R A T I N G I N S T R U C T I O N S UNIVERSAL SAFETY RETROREFLECTIVE PHOTOEYE U L MONITORED DEVICE

Industrial Power Supplies

HP UPS R/T3000 ERM. Overview. Precautions. Installation Instructions

IRB-MON O P E R A T I N G I N S T R U C T I O N S UNIVERSAL SAFETY PHOTOEYE U L M O N I T O R E D DEVICE

Transcription:

DC Outdoor Power Supply/Chargers Installation Guide Models Include: WayPoint3 WayPoint7-2.5A @ 12VDC or 24VDC. - 6A @ 12VDC or 24VDC. - 115/230VAC input. - 115VAC input. WayPoint5 WayPoint7V - 4A @ 12VDC or 24VDC. - 6A @ 12VDC or 24VDC. - 115/230VAC input. - 230VAC input. WayPoint1012V WayPoint104-10A @ 12VDC. - 10A @ 24VDC. - 230VAC input. - 115VAC input. Rev. 080911DCPL More than just power.

Overview: These Altronix DC Outdoor Power Supply/Chargers provide 12VDC or 24VDC and are designed to be conveniently located where power is required. WayPoint DC Reference Chart: Altronix Model Number Total Output Current (Peak) Total Output Current (Continuous) Output Voltage SW1 115VAC/60Hz Input Current Draw 230VAC/50Hz Input Current Draw 12VDC 24VDC WayPoint3 2.5A 2A 12VDC or 24VDC ON OFF 0.95A 0.6A WayPoint5 4A 3.2A 12VDC or 24VDC ON OFF 0.95A 0.6A WayPoint7 6A 4.8A 12VDC or 24VDC ON OFF 1.9A N/A WayPoint7V 6A 4.8A 12VDC or 24VDC ON OFF N/A 0.95A WayPoint1012V 10A 8A 12VDC N/A N/A 3.0A WayPoint104 10A 8A 24VDC N/A 1.9A N/A Input: Input: 115VAC, 60Hz or 230VAC, 50Hz. Output: 12VDC or 24VDC selectable output (12VDC only for WayPoint1012V; 24VDC only for WayPoint104). Filtered and electronically regulated output. Thermal overload and short circuit protection. Battery Backup: Built-in charger for sealed lead acid or gel type batteries. Maximum charge current 500mA for WayPoint3/5/7/7V; 700mA for WayPoint1012V and WayPoint104. Automatic switch over to stand-by battery. Specifications: Features: AC and DC power LED indicators. Ease of installation saves time and eliminates costly labor. Includes battery leads. Accessories: Optional PMK1 Pole Mount Kit simplifies installation of outdoor units. Enclosure: NEMA 4/4X, IP66-11 Rated enclosure for outdoor use. Enclosure Dimensions (H x W x D approx.): 13.32 x 11.32 x 5.6 (338.28mm x 287.528mm x 142.24mm). Enclosure accommodates up to two (2) 12AH batteries. Installation Instructions: Wiring methods should be in accordance with the National Electrical Code/NFPA 70/NFPA 72/ANSI, and with all local codes and authorities having jurisdiction. 1. Remove back plane from the enclosure prior to mounting (do not discard hardware). 2. Mark and drill desired inlets on the enclosure to facilitate wiring (Fig. 1, pg. 3). 3. Mount unit in the desired location. For wall mounting refer to Fig. 5, pg. 7. For pole mounting installation refer to pg. 7 - (Using Optional Altronix Pole Mount Kit PMK1 - not included). 4. Install back plane inside the enclosure with hardware. 5. Set power switch to the OFF position (Fig. 2b, pg. 4, Fig. 4a, pg. 6). 6. Connect AC power (115VAC or 230 VAC) to the terminals marked [L & N], connect ground to the terminal marked [G] (Fig. 2-4, pgs. 4-6). Wire gauge range of connectors is 14 AWG to 11 AWG (1.6 mm to 2.5 mm diameter). 7. Select the desired DC output voltage by setting SW1 to the appropriate position for models WayPoint3, WayPoint5, WayPoint7, and WayPoint7V (Reference Chart above) (Fig. 2a, pg. 4). WayPoint1012V provides 12VDC only. WayPoint104 provides 24VDC only. 8. Set power switch to the ON position (Fig. 2b, pg. 4, Fig. 4a, pg. 6). 9. Measure output voltage at the terminals marked [ - DC +] before connecting devices (Fig. 2c, pg. 4, Fig. 3a, pg. 5, Fig. 4b, pg. 6). This helps avoiding potential damage. Note: Power supplies mounted in weatherproof enclosures should be derated by approximately 50% due to the harsh environmental conditions. 10. Set power switch to the OFF position (Fig. 2b, pg. 4, Fig. 4a, pg. 6). 11. Connect devices to be powered to the terminals marked [ - DC +] (Fig. 2c, pg. 4, Fig. 3a, pg. 5, Fig. 4b, pg. 6). 12. Connect optional stand-by battery to the terminals marked [--- BAT +]. Battery leads included. Enclosure accommodates up to two (2) 12AH batteries. If larger batteries are required, they need to be mounted in a separate NEMA rated enclosure adjacent to the power supply (Fig. 2c, pg. 4, Fig. 3b, pg. 5, Fig. 4b, pg. 6). Note: When batteries are not used, a loss of AC will result in a loss of output voltage. 13. Set power switch to the ON position (Fig. 2b, pg. 4, Fig. 3a, pg. 5). 14. Upon completion of the wiring secure enclosure door with latches and optional lock. - 2 - DC Outdoor

CAUTION: Equipment to be installed / serviced by authorized / trained personnel only. Shut branch circuit power before installing / servicing equipment. WARNING: When installing in a non-restricted service area, use lock or other fastened means on door latches. This installation should be made by qualified service personnel and should conform to the National Electrical Code and all local codes. LED Diagnostics: Red (DC) Green (AC) Power Supply Status ON ON Normal operating condition. ON OFF Loss of AC. Stand-by battery supplying power. OFF ON No DC output. Short circuit or thermal overload condition. OFF OFF No DC output. Loss of AC. Discharged or no battery present. The lightning flash with arrow head symbol within an equilateral triangle is intended to alert the user to the presence of an insulated DANGEROUS VOLTAGE within the product s enclosure that may be of sufficient magnitude to constitute an electric shock. The exclamation point within an equilateral triangle is intended to alert the user to the presence of important operating and maintenance (servicing) instructions in the literature accompanying the appliance. CAUTION: To reduce the risk of electric shock do not open enclosure. There are no user serviceable parts inside. Refer servicing to qualified service personnel. Terminal Identification: Terminal Legend Function/Description WayPoint3: 12VDC or 24VDC @ 2.5A peak supply current (2A continuous). WayPoint5: 12VDC or 24VDC @ 4A peak supply current (3.2A continuous). --- DC + WayPoint7: 12VDC or 24VDC @ 6A peak supply current (4.8A continuous). WayPoint1012V: 12VDC @ 10A peak supply current (8A continuous). WayPoint104: 24VDC @ 10A peak supply current (8A continuous). BAT + Stand-by battery connections. Maximum charge rate 500mA (700mA for WayPoint1012V/104). Fig. 1 Suggested Locations for Wiring Inlets Bottom of Enclosure DC Outdoor - 3 -

Fig. 2 - WayPoint3, WayPoint5, WayPoint7, and WayPoint7V. Fig. 2a OFF - 24V ON - 12V ON ON OFF - 24V ON - 12V Fig. 2b AC DC OFF ON OFF ON 5A 250V L G N --- BAT + --- DC + CAUTION HIGH VOLTAGE Fig. 2c --- BAT + --- DC + - 4 - DC Outdoor

Fig. 3 - WayPoint1012V VR1 15 --- DC + --- DC + + BAT --- Fig. 3a AC DELAY 5A 250V L G N BAT FAIL NC C NO NC C NO AC FAIL CAUTION HIGH VOLTAGE + BAT --- Fig. 3b DC Outdoor - 5 -

Fig. 4 - WayPoint104 Fig. 4a OFF ON OFF ON 5A 250V AC FAIL NC C NO NC C NO LOW BAT AC DC --- BAT + --- DC + 15 CAUTION HIGH VOLTAGE Fig. 4b --- BAT + --- DC + - 6 - DC Outdoor

Wall Mount Installation 1- Place unit at desired location and secure with mounting screws (not included) (Fig. 5, pg. 7). Fig. 5 Pole Mounting Using Optional Pole Mount Kit PMK1 (not included): This installation should be made by qualified service personnel. This product contains no serviceable parts. PMK1 is intended for use with Altronix outdoor rated power supplies or accessories housed in WP1, WP2, WP3 and WP4 enclosures. Brackets are designed for use with the Wormgear Quick Release Straps (two included). 1. Thread one (1) wormgear quick release strap through the slots on the back of a mounting bracket (Fig. 6, pg. 7). 2. Once the desired height of the top Pole Mount bracket is achieved, tighten the straps down by sliding open end of the strap through the locking mechanism on the strap, then tighten the screw with flat head screwdriver or 5/16 hex socket driver (Fig. 6, pg. 7 and Fig. 7, pg. 7). Fig. 8 Fig. 6 Fig. 7 3. Attach the bottom bracket to the enclosure by inserting bolts through the flange of the enclosure and into the bracket, tightening bolts with a 7/16 hex socket (Fig. 8, pg. 7). 4. Thread the second wormgear quick release strap through the slots on the back of the bottom mounting bracket (Fig. 6, pg. 7). 5. Mount enclosure onto the top bracket by inserting bolts through flange of the enclosure and into the bracket, tightening bolts with a 7/16 hex socket (Fig. 7, pg. 7). 6. Tighten the straps of the bottom bracket down by sliding the open end of the strap through the locking mechanism on the strap, then tighten screw with flat head screwdriver or 5/16 hex socket driver (Fig. 9/9a, pg. 7). 7. Clip excess straps. Fig. 7 Fig. 9-2 to 8 (50.8mm to 203.2mm) diameter round pole Fig. 9a - 5 (127mm) square pole DC Outdoor - 7 -

Enclosure Dimensions (H x W x D): 13.32 x 11.32 x 5.6 (338.28mm x 287.528mm x 142.24mm) 11.32 (287.528mm) STAINLESS STEEL PIANO HINGE 8.00 (203.2mm) 1.61 (40.894mm) 3.96 (100.584mm) 13.32 (338.328mm) 12.75 (323.85mm) 12.00 (304.8mm) 13.50 (342.9mm) 5.60 (142.24mm) PADLOCK LATCH ATTACHED WITH RIVETS (Ø 0.375 (9.52mm) PADLOCK EYE). Ø 0.32 (8.128mm) MOUNTING HOLE TYP. 4 PLACES 10.75 (273.05mm) 10.00 (254mm) 8.25 (209.55mm) 10-32 X 0.375 (9.525mm) BRASS INSERT (X4) 10.25 (260.35mm) 10-32 X 0.25 (6.35mm) BRASS INSERT (X2) Altronix is not responsible for any typographical errors. 140 58th Street, Brooklyn, New York 11220 USA, 718-567-8181, fax: 718-567-9056 web site: www.altronix.com, e-mail: info@altronix.com. Lifetime Warranty, Made in U.S.A. IIWayPointDC Series A15P MEMBER - 8 - DC Outdoor